Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Base”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Identification of proteins capable of metal reduction from the proteome of the Gram‐positive bacterium D esulfotomaculum reducens MI ‐1 using an NADH ‐based activity assay

Summary Understanding of microbial metal reduction is based almost solely on studies of G ram‐negative organisms. In this study, we focus on D esulfotomaculum reducens MI ‐1, a G ram‐positive metal reducer whose genome lacks genes with similarity to any characterized metal reductase. Using non‐denaturing separations and mass spectrometry identification, in combination with a colorimetric screen for chelated F e( III )‐ NTA reduction with NADH as electron donor, we have identified proteins from the D . reducens proteome not previously characterized as iron reductases. Their function was confirmed by heterologous expression in E scherichia coli . Furthermore, we show that these proteins have the capability to reduce soluble C r( VI ) and U ( VI ) with NADH as electron donor. The proteins identified are NADH : flavin oxidoreductase ( D red_2421) and a protein complex composed of oxidoreductase flavin adenine dinucleotide/ NAD ( P )‐binding subunit ( D red_1685) and dihydroorotate dehydrogenase 1B ( D red_1686). D red_2421 was identified in the soluble proteome and is predicted to be a cytoplasmic protein. D red_1685 and D red_1686 were identified in both the soluble as well as the insoluble protein fraction, suggesting a type of membrane association, although PSORTb predicts both proteins are cytoplasmic. This study is the first functional proteomic analysis of D . reducens and one of the first analyses of metal and radionuclide reduction in an environmentally relevant G ram‐positive bacterium.

Otwell, Anne Elyse↗

Variance-Based Sensitivity Analysis to Support Simulation-Based Design Under Uncertainty

Sensitivity analysis plays a critical role in quantifying uncertainty in the design of engineering systems. A variance-based global sensitivity analysis is often used to rank the importance of input factors, based on their contribution to the variance of the output quantity of interest. However, this analysis assumes that all input variability can be reduced to zero, which is typically not the case in a design setting. Distributional sensitivity analysis (DSA) instead treats the uncertainty reduction in the inputs as a random variable, and defines a variance-based sensitivity index function that characterizes the relative contribution to the output variance as a function of the amount of uncertainty reduction. This paper develops a computationally efficient implementation for the DSA formulation and extends it to include distributions commonly used in engineering design under uncertainty. Application of the DSA method to the conceptual design of a commercial jetliner demonstrates how the sensitivity analysis provides valuable information to designers and decision-makers on where and how to target uncertainty reduction efforts.

42 ENGINEERING↗

SU-D-BRD-02: A Web-Based Image Processing and Plan Evaluation Platform (WIPPEP) for Future Cloud-Based Radiotherapy

Purpose: Visualization and processing of medical images and radiation treatment plan evaluation have traditionally been constrained to local workstations with limited computation power and ability of data sharing and software update. We present a web-based image processing and planning evaluation platform (WIPPEP) for radiotherapy applications with high efficiency, ubiquitous web access, and real-time data sharing. Methods: This software platform consists of three parts: web server, image server and computation server. Each independent server communicates with each other through HTTP requests. The web server is the key component that provides visualizations and user interface through front-end web browsers and relay information to the backend to process user requests. The image server serves as a PACS system. The computation server performs the actual image processing and dose calculation. The web server backend is developed using Java Servlets and the frontend is developed using HTML5, Javascript, and jQuery. The image server is based on open source DCME4CHEE PACS system. The computation server can be written in any programming language as long as it can send/receive HTTP requests. Our computation server was implemented in Delphi, Python and PHP, which can process data directly or via a C++ program DLL. Results: This software platform is running on a 32-core CPU server virtually hosting the web server, image server, and computation servers separately. Users can visit our internal website with Chrome browser, select a specific patient, visualize image and RT structures belonging to this patient and perform image segmentation running Delphi computation server and Monte Carlo dose calculation on Python or PHP computation server. Conclusion: We have developed a webbased image processing and plan evaluation platform prototype for radiotherapy. This system has clearly demonstrated the feasibility of performing image processing and plan evaluation platform through a web browser and exhibited potential for future cloud based radiotherapy.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-07: Evaluation of a Grid-Based Boltzmann Solver for Nuclear Medicine Voxel-Based Dose Calculations

Purpose: Grid-based Boltzmann solvers (GBBS) have been successfully implemented in radiation oncology clinics as dose calculations for e×ternal photon beams and 192Ir sealed-source brachytherapy. We report on the evaluation of a GBBS for nuclear medicine vo×el-based absorbed doses. Methods: Vo×el-S-values were calculated for monoenergetic betas and photons (1, 0.1, 0.01 MeV), 90Y, and 131I for 3 mm vo×el sizes using Monte Carlo (DOS×YZnrc) and GBBS (Attila 8.1-beta5, Transpire). The source distribution was uniform throughout a single vo×el. The material was an infinite 1.04 g/cc soft tissue slab. To e×plore convergence properties of the GBBS 3 tetrahedral meshes, 3 energy group structures, 3 different square Chebyschev-Legendre quadrature set orders (Sn), and 4×2013;7 spherical harmonic e×pansion terms (Pn) were investigated for a total of 168 discretizations per source. The mesh, energy group, and quadrature sets are 8×, 3×, and 16×, respectively, finer than the corresponding coarse discretization. GBBS cross sections were generated with full electronphoton-coupling using the vendors e×tended CEP×S code. For accuracy, percent differences (%Δ) in source vo×el absorbed doses between MC and GBBS are reported for the coarsest and finest discretization. For convergence, ratios of the two finest discretization solutions are reported along each variable. Results: For 1 MeV, 0.1 MeV, 0.01 MeV, Y90, and I-131 beta sources the %Δ in the source vo×el for (coarsest,finest) discretization were (+2.0,−6.4), (−8.0, −7.5), (−13.8, −13.4), (+0.9,−5.5), and (− 10.1,−9.0) respectively. The corresponding %Δ for photons were (+33.7,−7.1), (−9.4, −9.8), (−17.4, −15.2), and (−1.7,−7.7), respectively. For betas, the convergence ratio of mesh, energy, Sn, and Pn ranged from 0.991–1.000. For gammas, the convergence ratio of mesh, Sn, and Pn ranged from 0.998–1.003 while the ratio for energy ranged from 0.964–1.001. Conclusions: GBBS is promising for nuclear medicine vo×el-based dose calculations. Ongoing work includes evaluating GBBS in bone, lung, and realistic clinical PET/SPECT-based activity distributions. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRA-13: Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Based On Principle Component Analysis

Purpose: To create a knowledge-based algorithm for prostate LDR brachytherapy treatment planning that standardizes plan quality using seed arrangements tailored to individual physician preferences while being fast enough for real-time planning. Methods: A dataset of 130 prior cases was compiled for a physician with an active prostate seed implant practice. Ten cases were randomly selected to test the algorithm. Contours from the 120 library cases were registered to a common reference frame. Contour variations were characterized on a point by point basis using principle component analysis (PCA). A test case was converted to PCA vectors using the same process and then compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Computational time was recorded. Any subsequent modifications were recorded that required input from a treatment planner to achieve an acceptable plan. Results: The computational time required to register contours from a test case and evaluate PCA similarity across the library was approximately 10s. Five of the ten test cases did not require any seed additions, deletions, or moves to obtain an acceptable plan. The remaining five test cases required on average 4.2 seed modifications. The time to complete manual plan modifications was less than 30s in all cases. Conclusion: A knowledge-based treatment planning algorithm was developed for prostate LDR brachytherapy based on principle component analysis. Initial results suggest that this approach can be used to quickly create treatment plans that require few if any modifications by the treatment planner. In general, test case plans have seed arrangements which are very similar to prior cases, and thus are inherently tailored to physician preferences.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-02: From Teaching to Learning: Systems-Based-Practice and Practice-Based-Learning Innovations in Medical Physics Education Programs

Purpose: The increasing complexity in the field of radiation medicine and concomitant rise in patient safety concerns call for enhanced systems-level training for future medical physicists and thus commensurate innovations in existing educational program curricula. In this work we report on the introduction of three learning opportunities to augment medical physics educational programs towards building systems-based practice and practice-based learning competencies. Methods: All initiatives were introduced for senior -level graduate students and physics residents in an institution with a newly established medical-physics graduate program and therapeutic-physics residency program. The first, centered on incident learning, was based on a spreadsheet tool that incorporated the reporting structure of the Radiation Oncology-incident Learning System (ROILS), included 120 narratives of published incidents and enabled inter-rater variability calculations. The second, centered on best-practices, was a zero-credit seminar course, where students summarized select presentations from the AAPM virtual library on a weekly basis and moderated class discussions using a point/counterpoint approach. Presentation styles were critiqued. The third; centered on learning-by-teaching, required physics residents to regularly explain fundamental concepts in radiological physics from standard textbooks to board certified physics faculty members. Results: Use of the incident-learning system spreadsheet provided a platform to recast known accidents into the framework of ROILS, thereby increasing awareness of factors contributing to unsafe practice and appreciation for inter-rater variability. The seminar course enhanced awareness of best practices, the effectiveness of presentation styles and encouraged critical thinking. The learn-by-teaching rotation allowed residents to stay abreast of and deepen their knowledge of relevant subjects. Conclusion: The incorporation of systems-driven initiatives broadens comprehension of the wider systems context of medical physics, enhances awareness of resources for innovation, communication and sustained learning while maintaining a metric-driven focus on patient safety within the formative phase of student careers. The initiatives were well-received, feasible, and utilized available or shared-resources translatable across educational programs.

60 APPLIED LIFE SCIENCES↗

Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments

Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

A clinically observed discrepancy between image-based and log-based MLC positions

Purpose: To present a clinical case in which real-time intratreatment imaging identified an multileaf collimator (MLC) leaf to be consistently deviating from its programmed and logged position by >1 mm. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used to capture cine during treatment images. The author serendipitously visually identified a suspected MLC leaf displacement that was not otherwise detected. The leaf position as recorded on the EPID images was measured and log-files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log-file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3 ± 0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusions: It has been clinically observed that log-file derived leaf positions can differ from their actual position by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trust log-file records. Intratreatment EPID imaging provides a method to capture departures from MLC planned positions.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-03: PCA Based Imaging Angle Optimization for 2D Cine MRI Based Radiotherapy Guidance

Purpose: To develop an imaging angle optimization methodology for orthogonal 2D cine MRI based radiotherapy guidance using Principal Component Analysis (PCA) of target motion retrieved from 4DCT. Methods: We retrospectively analyzed 4DCT of 6 patients with lung tumor. A radiation oncologist manually contoured the target volume at the maximal inhalation phase of the respiratory cycle. An object constrained deformable image registration (DIR) method has been developed to track the target motion along the respiration at ten phases. The motion of the center of the target mass has been analyzed using the PCA to find out the principal motion components that were uncorrelated with each other. Two orthogonal image planes for cineMRI have been determined using this method to minimize the through plane motion during MRI based radiotherapy guidance. Results: 3D target respiratory motion for all 6 patients has been efficiently retrieved from 4DCT. In this process, the object constrained DIR demonstrated satisfactory accuracy and efficiency to enable the automatic motion tracking for clinical application. The average motion amplitude in the AP, lateral, and longitudinal directions were 3.6mm (min: 1.6mm, max: 5.6mm), 1.7mm (min: 0.6mm, max: 2.7mm), and 5.6mm (min: 1.8mm, max: 16.1mm), respectively. Based on PCA, the optimal orthogonal imaging planes were determined for cineMRI. The average angular difference between the PCA determined imaging planes and the traditional AP and lateral imaging planes were 47 and 31 degrees, respectively. After optimization, the average amplitude of through plane motion reduced from 3.6mm in AP images to 2.5mm (min:1.3mm, max:3.9mm); and from 1.7mm in lateral images to 0.6mm (min: 0.2mm, max:1.5mm), while the principal in plane motion amplitude increased from 5.6mm to 6.5mm (min: 2.8mm, max: 17mm). Conclusion: DIR and PCA can be used to optimize the orthogonal image planes of cineMRI to minimize the through plane motion during radiotherapy guidance.

60 APPLIED LIFE SCIENCES↗

AlGaInN-based light emitting diodes with a transparent p-contact based on thin ITO films

A method for obtaining transparent conductive ITO (indium-tin oxide) films aimed for use in light emitting diodes of the blue spectral range is developed. The peak external quantum efficiency of light-emitting diodes with a p-contact based on the obtained films reaches 25%, while for similar light-emitting diodes with a standard semitransparent metal contact, it is <10%. An observed increase in the direct voltage drop from 3.15 to 3.37 V does not significantly affect the possibility of applying these films in light-emitting diodes since the optical power of light-emitting diodes with a transparent p-contact based on ITO films exceeds that of chips with metal semitransparent p-contacts with a working current of 20 mA by a factor of almost 2.5. Light-emitting diodes with p-contacts based on ITO films successfully withstand a pumping current that exceeds their calculated working current by a factor of 5 without the appearance of any signs of degradation.

36 MATERIALS SCIENCE↗

The Effect of Base Thickness on Photoconversion Efficiency in Textured Silicon-Based Solar Cells

A theory is developed, which describes the experimental external quantum efficiency, EQE(λ) as a function of photon wavelength for structured Si-based solar cells. Short-circuit current density as a function of base thickness, d, is calculated for the high-efficiency solar cells with the photoconversion efficiency η ≥ 25% The procedure allows one to carry out a complete optimization of such solar cells, in particular, to find the optimal base thickness, d{sub opt}.

14 SOLAR ENERGY↗

Mr. Scan: extreme scale density-based clustering using a tree-based network of GPGPU nodes, In: SC '13 Proceedings of the International Conference on High Performance Computing, Networking, Storage and Analysis

Density-based clustering algorithms are a widely-used class of data mining techniques that can find irregularly shaped clusters and cluster data without prior knowledge of the number of clusters it contains. DBSCAN is the most well-known density-based clustering algorithm. We introduce our version of DBSCAN, called Mr. Scan, which uses a hybrid parallel implementation that combines the MRNet tree-based distribution network with GPGPU-equipped nodes. Mr. Scan avoids the problems of existing implementations by effectively partitioning the point space and by optimizing DBSCAN's computation over dense data regions. We tested Mr. Scan on both a geolocated Twitter dataset and image data obtained from the Sloan Digital Sky Survey. At its largest scale, Mr. Scan clustered 6.5 billion points from the Twitter dataset on 8,192 GPU nodes on Cray Titan in 17.3 minutes. All other parallel DBSCAN implementations have only demonstrated the ability to cluster up to 100 million points.

Computer Science↗

Simulation of Impedance Changes with Aging in Lithium Titanate-based Cells Using Physics-Based Dimensionless Modeling

Quantifying aging effects in lithium-ion cells with chemistries that have a flat open circuit potential is challenging. We implement a physics-based electrochemical model to track changes in the electrochemical impedance response of lithium titanate-based cells. Frequency domain equations of a pseudo two-dimensional model are made dimensionless, and the corresponding non-dimensional parameters are estimated using a Levenberg-Marquardt routine. The model weighs the relative contributions of changes in diffusion, ionic conduction within the electrolyte phase against solid phase electronic conduction towards cell aging. Solid-phase diffusion, charge transfer resistance and double layer capacitance at the solid-liquid interface are accounted for in the particle impedance. The estimation routine tracks dimensionless parameters using accelerated cycling data from full cells over 1000 cycles. The model can be deployed within a short time for state estimation using physics-based models without requiring prior knowledge of the battery chemistry, format, or capacity.

25 ENERGY STORAGE↗

Reconciling Ground-Based and Space-Based Estimates of the Frequency of Occurrence and Radiative Effect of Clouds around Darwin, Australia

The objective of this paper is to investigate whether estimates of the cloud frequency of occurrence and associated cloud radiative forcing as derived from ground-based and satellite active remote sensing and radiative transfer calculations can be reconciled over a well instrumented active remote sensing site located in Darwin, Australia, despite the very different viewing geometry and instrument characteristics. It is found that the ground-based radar-lidar combination at Darwin does not detect most of the cirrus clouds above 10 km (due to limited lidar detection capability and signal obscuration by low-level clouds) and that the CloudSat radar - Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) combination underreports the hydrometeor frequency of occurrence below 2 km height, due to instrument limitations at these heights. The radiative impact associated with these differences in cloud frequency of occurrence is large on the surface downwelling shortwave fluxes (ground and satellite) and the top-of atmosphere upwelling shortwave and longwave fluxes (ground). Good agreement is found for other radiative fluxes. Large differences in radiative heating rate as derived from ground and satellite radar-lidar instruments and RT calculations are also found above 10 km (up to 0.35 Kday-1 for the shortwave and 0.8 Kday-1 for the longwave). Given that the ground-based and satellite estimates of cloud frequency of occurrence and radiative impact cannot be fully reconciled over Darwin, caution should be exercised when evaluating the representation of clouds and cloud-radiation interactions in large-scale models and limitations of each set of instrumentation should be considered when interpreting model-observations differences.

clouds↗

Virtual machine-based simulation platform for mobile ad-hoc network-based cyber infrastructure

In modeling and simulating complex systems such as mobile ad-hoc networks (MANETs) in de-fense communications, it is a major challenge to reconcile multiple important considerations: the rapidity of unavoidable changes to the software (network layers and applications), the difficulty of modeling the critical, implementation-dependent behavioral effects, the need to sustain larger scale scenarios, and the desire for faster simulations. Here we present our approach in success-fully reconciling them using a virtual time-synchronized virtual machine(VM)-based parallel ex-ecution framework that accurately lifts both the devices as well as the network communications to a virtual time plane while retaining full fidelity. At the core of our framework is a scheduling engine that operates at the level of a hypervisor scheduler, offering a unique ability to execute multi-core guest nodes over multi-core host nodes in an accurate, virtual time-synchronized manner. In contrast to other related approaches that suffer from either speed or accuracy issues, our framework provides MANET node-wise scalability, high fidelity of software behaviors, and time-ordering accuracy. The design and development of this framework is presented, and an ac-tual implementation based on the widely used Xen hypervisor system is described. Benchmarks with synthetic and actual applications are used to identify the benefits of our approach. The time inaccuracy of traditional emulation methods is demonstrated, in comparison with the accurate execution of our framework verified by theoretically correct results expected from analytical models of the same scenarios. In the largest high fidelity tests, we are able to perform virtual time-synchronized simulation of 64-node VM-based full-stack, actual software behaviors of MANETs containing a mix of static and mobile (unmanned airborne vehicle) nodes, hosted on a 32-core host, with full fidelity of unmodified ad-hoc routing protocols, unmodified application executables, and user-controllable physical layer effects including inter-device wireless signal strength, reachability, and connectivity.

97 MATHEMATICS AND COMPUTING↗

Exploring soybean metabolic pathways based on probabilistic graphical model and knowledge-based methods

Soybean (Glycine max) is a major source of vegetable oil and protein for both animal and human consumption. The completion of soybean genome sequence led to a number of transcriptomic studies (RNA-seq), which provide a resource for gene discovery and functional analysis. Several data-driven (e.g., based on gene expression data) and knowledge-based (e.g., predictions of molecular interactions) methods have been proposed and implemented. In order to better understand gene relationships and protein interactions, we applied probabilistic graphical methods, based on Bayesian network and knowledgebase constraints using gene expression data to reconstruct soybean metabolic pathways. The results show that this method can predict new relationships between genes, improving on traditional reference pathway maps.

54 ENVIRONMENTAL SCIENCES↗

A fast particle-based approach for calibrating a 3-D model of the Antarctic ice sheet

We consider the scientifically challenging and policy-relevant task of understanding the past and projecting the future dynamics of the Antarctic ice sheet. The Antarctic ice sheet has shown a highly nonlinear threshold response to past climate forcings. Triggering such a threshold response through anthropogenic greenhouse gas emissions would drive drastic and potentially fast sea level rise with important implications for coastal flood risks. Previous studies have combined information from ice sheet models and observations to calibrate model parameters. These studies have broken important new ground but have either adopted simple ice sheet models or have limited the number of parameters to allow for the use of more complex models. These limitations are largely due to the computational challenges posed by calibration as models become more computationally intensive or when the number of parameters increases. Here, we propose a method to alleviate this problem: a fast sequential Monte Carlo method that takes advantage of the massive parallelization afforded by modern high-performance computing systems. We use simulated examples to demonstrate how our sample-based approach provides accurate approximations to the posterior distributions of the calibrated parameters. The drastic reduction in computational times enables us to provide new insights into important scientific questions, for example, the impact of Pliocene era data and prior parameter information on sea level projections. These studies would be computationally prohibitive with other computational approaches for calibration such as Markov chain Monte Carlo or emulation-based methods. We also find considerable differences in the distributions of sea level projections when we account for a larger number of uncertain parameters. For example, based on the same ice sheet model and data set, the 99th percentile of the Antarctic ice sheet contribution to sea level rise in 2300 increases from 6.5 m to 13.1 m when we increase the number of calibrated parameters from three to 11. With previous calibration methods, it would be challenging to go beyond five parameters. Here, this work provides an important next step toward improving the uncertainty quantification of complex, computationally intensive and decision-relevant models.

54 ENVIRONMENTAL SCIENCES↗