Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Background”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Liquid Scintillation Counting of Environmental Radioisotopes: A Review of the Impact of Background Reduction

Liquid scintillation counting (LSC) is a versatile and commonplace method for radiometric measurement of charged particle emitting radionuclides. The LSC method provides utility in a range of environmental science applications including hydrological studies of water transport, anthropogenic releases of radionuclides into the environment, and vertical mixing rates within oceans. Instrumental measurement background is one limiting factor of radiometric measurement sensitivity. As part of the development of a custom low background LSC system located in a shallow underground laboratory at Pacific Northwest National Laboratory, a number of measurement applications of LSC have been considered and are summarized here. The focus is on determining which aspects of such measurements would gain the greatest benefit from the reduction of LSC backgrounds by a factor of 10-100 relative to values reported in the literature. Examples of benefits include lowering the minimum detectable activity, reducing the sample size required, and shortening the elapsed timeline of the processing and analysis sequence. In particular tritium, strontium, and actinium isotopes are examined as these isotopes cover a range of requirements related to the LSC measurement method (e.g., 3H: low energy; Sr: spectral deconvolution; Ac: alpha/beta discrimination).

actinium↗

Recent Bremsstrahlung-based Assays of 210Pb in Lead and Comments on Current Availability of Low-Background Lead in North America

Abstract Low-background lead for radiation measurement shielding is often assayed for 210Pb to ensure acceptable backgrounds. Samples of lead assayed with a germanium spectrometer calibrated for bremsstrahlung-based assay of 210Pb provide a view into the 210Pb content of commercial lead in the U.S. (other than stockpiled Doe Run lead). Results suggest that the loss of lead smelting in the U.S. has eliminated the traditional supply of “low background” lead (~30 Bq·kg-1), and indicate current commercial supplies contain roughly an order of magnitude higher 210Pb levels.

Low background, gamma spectroscopy, lead, bremsstr↗

Measurement of the gamma ray background in the Davis cavern at the Sanford Underground Research Facility

Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from γ -rays emitted by 40 K and the 238 U and 232 Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4850-foot level. In order to characterise the cavern background, in-situ γ -ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0–3300 keV) varied from 596 Hz to 1355 Hz for unshielded measurements, corresponding to a total flux from the cavern walls of 1.9 ± 0.4 γ cm −2 s −1 . The resulting activity in the walls of the cavern can be characterised as 220 ± 60 Bq/kg of 40 K, 29 ± 15 Bq/kg of 238 U, and 13 ± 3 Bq/kg of 232 Th.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sources of machine-induced background in the ATLAS and CMS detectors at the CERN Large Hadron Collider

One source of experimental background in the CERN Large Hadron Collider (LHC) is particles entering the detectors from the machine. These particles are created in cascades, caused by upstream interactions of beam protons with residual gas molecules or collimators. We estimate the losses on the collimators with SixTrack and simulate the showers with FLUKA and MARS to obtain the flux and distribution of particles entering the ATLAS and CMS detectors. We consider some machine configurations used in the first LHC run, with focus on 3.5 TeV operation as in 2011. Results from FLUKA and MARS are compared and a very good agreement is found. An analysis of logged LHC data provides, for different processes, absolute beam loss rates, which are used together with further simulations of vacuum conditions to normalize the results to rates of particles entering the detectors. We assess the relative importance of background from elastic and inelastic beam-gas interactions, and the leakage out of the LHC collimation system, and show that beam-gas interactions are the dominating source of machine-induced background for the studied machine scenarios. Our results serve as a starting point for the experiments to perform further simulations in order to estimate the resulting signals in the detectors.

Circular colliders↗

Background evaluation for the neutron sources in the Daya Bay experiment

Here, we present an evaluation of the background induced by 241Am–13C neutron calibration sources in the Daya Bay reactor neutrino experiment. Furthermore, as a significant background for electron-antineutrino detection at 0.26 ± 0.12 detector per day on average, it has been estimated by a Monte Carlo simulation that was benchmarked by a special calibration data set. This dedicated data set also provides the energy spectrum of the background.

241AM-13C neutron source↗

Attribution of gamma-ray background collected by a mobile detector system to its surroundings using panoramic video

Mobile radiation detector systems are important tools for detecting radiological and nuclear sources outside of regulatory control, but due to their mobility, they are subject to complex and varying backgrounds in most realistic operational scenarios. Recent work has found correlations between non-radiological contextual information and gamma-ray spectral features that can be used to decrease false alarm rates, however a more complete understanding of background source terms has been elusive. A measurement campaign developed a full radiological characterization of a controlled facility that roughly corresponded to two city blocks. As part of the campaign, the Radiological Multi-sensor Analysis Platform (RadMAP) collected extensive multi-sensor data. In this work, RadMAP’s panoramic video data were used to visually identify several different materials and quantify the detector response to each material. A linear model was fit between the material responses and radiological features, and the results demonstrate reasonable agreement with ground truth flux measurements for each material. This paper will describe the data collection, processing, and analysis of the gamma-ray and video data from RadMAP. The paper will conclude with perspectives on the applicability of such a method to less controlled environments both with respect to achieving better understanding the sources of variability of background radiation in urban environments and whether such methods could be leveraged in operational scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neural network for beam background decomposition in Belle II at SuperKEKB

Here, we describe a neural network for predicting the background hit rate in the Belle II detector produced by the SuperKEKB electron-positron collider. The neural network, BGNet, learns to predict the individual contributions of different physical background sources, such as beam-gas scattering or continuous top-up injections into the collider, to Belle II sub-detector rates. The samples for learning are archived 1 Hz time series of diagnostic variables from the SuperKEKB collider subsystems and measured hit rates of Belle II used as regression targets. We test the learned model by predicting detector hit rates on archived data from different run periods not used during training. We show that a feature attribution method can help interpret the source of changes in the background level over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RPC background studies at CMS experiment

During Run2 the high instantaneous luminosity, up to 2.2 · 10 34 cm -2 s -1 , lead to a substantial hit rate in the Compact Muon Solenoid experiment’s muon chambers due to multiple background sources to physics processes sought for at LHC. In this article we will describe the analysis method devised to measure and identify the contributions to such background in the Resistive Plate Chambers. Thorough understanding of the background rates provides the base for the upgrade of the muon detectors for the High-Luminosity LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel invariant mass method to isolate resonance backgrounds from the chiral magnetic effect

The Chiral Magnetic Effect (CME) refers to charge separation along a strong magnetic field, due to topological charge fluctuations in QCD. Charge correlation (Δγ) signals consistent with CME have been first observed almost a decade ago. It has also been known since then that the Δγ is contaminated by a major background from resonance decays coupled with elliptic flow. In this contribution, we propose differential Δγ measurements as function of the pair invariant mass (m inv ). The Δγ in the high minv region is essentially free of resonance backgrounds. In the low m inv region, the Δγ backgrounds show resonance peaks. The CME signal, presumably smooth in m inv , may thus be extracted from a two-component model fit. We demonstrate the feasibility and effectiveness of this novel method by using the AMPT and toy-model Monte-Carlo simulations. We also discuss an application of the method in data analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Background Due To Particle Induced Gas Desorption In RHIC

Beam-gas collision created experimental background, i.e., singles, has affected heavy ion and polarized proton operations in Relativistic Heavy Ion Collider at Brookhaven National Laboratory. The gas molecules in interaction region are mainly caused by the electron induced gas desorption, and the electrons are produced from the beam induced electron multipacting, or called electron cloud. The background has a dependence on the usual electron cloud related parameters, such as the bunch intensity, bunch spacing, and the solenoid field. With the RHIC upgrade plan, the experimental background may become a luminosity limiting factor. Mitigations are discussed.

43 PARTICLE ACCELERATORS↗

Experimental study of neutron induced background noise on gated x-ray framing cameras

A temporally gated x-ray framing camera based on a proximity focus microchannel plate is one of the most important diagnostic tools of inertial confinement fusion experiments. However, fusion neutrons produced in imploded capsules interact with structures surrounding the camera and produce background to x-ray signals. To understand the mechanisms of this neutron induced background, we tested several gated x-ray cameras in the presence of 14 MeV neutrons produced at the Omega laser facility. Differences between background levels observed with photographic film readout and charge-coupled-device readout have been studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background simulations and shielding calculations

Key improvements in the sensitivity of the underground particle astrophysics experiments can only be achieved if the radiation causing background events in detectors is well understood and proper measures are taken to suppress it. The background radiation arising from radioactivity and cosmic-ray muons is discussed here together with the methods of its suppression. Different shielding designs are considered to attenuate gamma-rays and neutrons coming from radioactivity in rock and lab walls. Purity of materials used in detector construction is analysed and the background event rates due to the presence of radioactive isotopes in detector components are discussed. Event rates in detectors caused by muon-induced neutrons with and without active veto systems are presented leading to the requirements for the depth of an underground laboratory and the efficiency of the veto system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of low radioactivity background in a high voltage cable by high resolution inductively coupled plasma mass spectrometry

The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Level Assay) of the LNGS underground lab using HPGe detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte-Carlo simulation of noise in hard X-ray Transmission Crystal Spectrometers: Identification of contributors to the background noise and shielding optimization

Transmission crystal spectrometers (TCS) are used on many laser facilities to record hard X-ray spectra. During experiments, signal recorded on imaging plates is often degraded by a background noise. Monte-Carlo simulations made with the code GEANT4 show that this background noise is mainly generated by diffusion of MeV electrons and very hard X-rays. An experiment, carried out at LULI2000, confirmed that the use of magnets in front of the diagnostic, that bent the electron trajectories, reduces significantly this background. The new spectrometer SPECTIX (Spectromètre PETAL à Cristal en TransmIssion X), built for the LMJ/PETAL facility, will include this optimized shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Article: Characterization of background sources in space-based time-of-flight mass spectrometers

For instruments that use time-of-flight techniques to measure space plasma, there are common sources of background signals that evidence themselves in the data. The background from these sources may increase the complexity of data analysis and reduce the signal-to-noise response of the instrument, thereby diminishing the science value or usefulness of the data. This paper reviews several sources of background commonly found in time-of-flight mass spectrometers and illustrates their effect in actual data using examples from ACE-SWICS and MESSENGER-FIPS. Sources include penetrating particles and radiation, UV photons, energy straggling and angular scattering, electron stimulated desorption of ions, ion-induced electron emission, accidental coincidence events, and noise signatures from instrument electronics. Data signatures of these sources are shown, as well as mitigation strategies and design considerations for future instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryocooled terahertz photoconductive detector system with background-limited performance in 1.5–4 THz frequency range

We describe a 4-K-cryocooled dual-band terahertz (THz) photoconductive detector system with background-limited performance. The detector system comprises two THz photoconductive detectors covering a response in a wide frequency range from 1.5 to 4 THz, low noise amplifiers, optical low-pass filters to eliminate input radiation of higher frequencies, and a mechanical 4 K Gifford-McMahon refrigerator that provides practical and convenient operation without a liquid He container. The electrical and optical performances of the THz detector system were evaluated at a detector temperature of 4 K under 300 K background radiation. We proved that the detector system can achieve background-limited noise-equivalent-power on the order of 10{sup −14} W/Hz{sup 1/2} in the frequency range from 1.5 to 4 THz even if the vibration noise of the mechanical refrigerator is present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MEASUREMENT OF COSMIC MICROWAVE BACKGROUND POLARIZATION POWER SPECTRA FROM TWO YEARS OF BICEP DATA

Background Imaging of Cosmic Extragalactic Polarization (BICEP) is a bolometric polarimeter designed to measure the inflationary B-mode polarization of the cosmic microwave background (CMB) at degree angular scales. During three seasons of observing at the South Pole (2006 through 2008), BICEP mapped {approx}2% of the sky chosen to be uniquely clean of polarized foreground emission. Here, we present initial results derived from a subset of the data acquired during the first two years. We present maps of temperature, Stokes Q and U, E and B modes, and associated angular power spectra. We demonstrate that the polarization data are self-consistent by performing a series of jackknife tests. We study potential systematic errors in detail and show that they are sub-dominant to the statistical errors. We measure the E-mode angular power spectrum with high precision at 21 <= l <= 335, detecting for the first time the peak expected at l {approx} 140. The measured E-mode spectrum is consistent with expectations from a LAMBDACDM model, and the B-mode spectrum is consistent with zero. The tensor-to-scalar ratio derived from the B-mode spectrum is r = 0.02{sup +0.31}{sub -0.26}, or r < 0.72 at 95% confidence, the first meaningful constraint on the inflationary gravitational wave background to come directly from CMB B-mode polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

ANGULAR POWER SPECTRA OF THE MILLIMETER-WAVELENGTH BACKGROUND LIGHT FROM DUSTY STAR-FORMING GALAXIES WITH THE SOUTH POLE TELESCOPE

We use data from the first 100 deg{sup 2} field observed by the South Pole Telescope (SPT) in 2008 to measure the angular power spectrum of temperature anisotropies contributed by the background of dusty star-forming galaxies (DSFGs) at millimeter wavelengths. From the auto- and cross-correlation of 150 and 220 GHz SPT maps, we significantly detect both Poisson distributed and, for the first time at millimeter wavelengths, clustered components of power from a background of DSFGs. The spectral indices of the Poisson and clustered components are found to be {alpha}-bar{sup P}{sub 150-220}=3.86{+-}0.23 and {alpha} {sup C}{sub 150-220} = 3.8 {+-} 1.3, implying a steep scaling of the dust emissivity index {beta} {approx} 2. The Poisson and clustered power detected in SPT, BLAST (at 600, 860, and 1200 GHz), and Spitzer (1900 GHz) data can be understood in the context of a simple model in which all galaxies have the same graybody spectrum with dust emissivity index of {beta} = 2 and dust temperature T{sub d} = 34 K. In this model, half of the 150 GHz background light comes from redshifts greater than 3.2. We also use the SPT data to place an upper limit on the amplitude of the kinetic Sunyaev-Zel'dovich power spectrum at l = 3000 of 13 {mu}K{sup 2} at 95% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗