Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Associated Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Coating developments towards enabling aluminum as a bipolar plate material for PEM fuel cells

Bipolar plates represent a significant portion of the cost and weight of a proton exchange membrane fuel cell stack. As a result, there has been significant interest in using low weight and cost materials, such as aluminum. Aluminum has good mechanical and physical properties; however, it performs poorly in the corrosive environment within the fuel cell stack. To overcome the corrosion performance issue, there have been efforts towards developing coating processes to enable aluminum to attain corrosion targets. In an effort to enable aluminum as a viable bipolar plate material, a solid phase processing (diffusion bonding) approach for bonding a titanium foil to aluminum is investigated in this study. The microstructure, corrosion performance, mechanical properties and electrical resistance are investigated. To avoid the known reduction in contact resistance performance of titanium after exposure to bipolar plate media, the effect of addition of highly conductive gold particles after diffusion bonding, on contact resistance and corrosion behavior, is also studied and compared with diffusion bonded Ti to Al. In conclusion, the results indicate that diffusion bonded Ti to Al provides a viable alternative material combination for bipolar plate that avoids the micro pores and crevasses that are associated with vapor deposition or electroplating.

25 ENERGY STORAGE↗

Characterization of shale using Helium and Argon at high pressures

In order to estimate the shale gas in place and the eventual recovery during shale gas operations, one of the key requirements is to accurately characterize the shale’s petrophysical and transport properties such as porosity, permeability, diffusivity, and storage capacity. Despite the many efforts reported in the technical literature aiming to provide an improved understanding of the complex pore structures and the associated fluid flow in gas shales, complete characterization of organic-rich shale samples still poses a big challenge. Here, we have characterized mass transfer and sorption in shale at different length scales using Helium (He) and Argon (Ar) as probe gases. Thermogravimetric analysis (TGA) with a shale cube of ~1 cm 3 in size and gas expansion experiments with a full-diameter core (3.5” in diameter) were used to measure sorption kinetics/isotherms and mass transfer, respectively. Both samples are from the same depth/location in the Marcellus shale formation. The TGA steady-state technique was initially used to generate excess sorption isotherms for Ar, while dynamic TGA experiments were used to study its sorption kinetics. The TGA experiments demonstrate that Ar, which has a similar sorption potential as Methane, but is generally assumed to be inert, adsorbs onto the surfaces of the mesoporous and microporous regions of the shale samples according to a Langmuir-type behavior. Helium expansion experiments, on the full-diameter core, were used to measure the overall porosity, on the basis that He is a non-sorbing and inert gas as compared to Ar. The He expansion experiments, furthermore, allow us to delineate the mass transfer of gas across the inherent hierarchy of pore sizes, including macropores (macro- and microcracks), mesopores and micropores. Similar expansion experiments were also performed with Ar to study the combined impact of mass transfer and sorption. A triple-porosity model (TPM) was utilized to interpret the He expansion experiments with the shale core and to extract (estimate) relevant transport parameters. We report and compare here the diffusivities and permeabilities of the whole core for both He and Ar, as calculated from the modeling and fitting of the experimental data. On the premise that the shale cube is representative of the matrix region of the core, the Ar sorption kinetics from the cube experiments were subsequently combined with the transport parameters extracted from the He experiments to predict the behavior of the Ar expansion test with the full-diameter core. An excellent agreement is observed between the model predictions and the experimental data. The experimental observations and their interpretation indicate that one must be cautious when using Ar to estimate the true porosity and permeability of shales. In addition, we demonstrate that He and Ar probe gases, when used in tandem, can be employed effectively as a tool to characterize shales in terms of mass transfer and sorption dynamics across scales.

04 OIL SHALES AND TAR SANDS↗

Financial Analysis of the High Flow Experiment conducted at the Glen Canyon Dam during Water Year 2023

The Glen Canyon Dam (GCD) is a Colorado River Storage Project (CRSP) power resource that is a component of the Salt Lake City Area Integrated Projects (SLCA/IP). The 2016 record of decision (ROD) for the GCD long-term experimental and management plan (LTEMP) final Environmental Impact Statement (EIS) specified criteria for GCD monthly water releases, daily and hourly operating limits, and experimental releases. This report examines the financial implications of the high flow experiment (HFE) conducted at GCD during the spring of Water Year (WY) 2023 as required by the LTEMP HFE Protocol. This report is part of a series of reports that describe the financial costs of LTEMP experimental releases since the 2016 ROD was adopted in January 2017. Previous reports analyzed the impact of several past HFEs and Bug Flow Experiments. This report focuses on the HFE conducted in April 2023. For this experimental release, financial costs of approximately $1.33 million were incurred because the HFE required sustained water releases exceeding the power plant’s maximum turbine flow rate. In addition, during the experiment, operators were not allowed to shape GCD power production, either to follow Firm Electric Service (FES) customer day-ahead energy deliveries or to respond to market prices. This study identifies the main factors contributing to the HFE costs and examines the interdependencies among these factors. It applies an integrated set of tools to estimate Western Area Power Administration (WAPA) financial impacts by simulating GCD under two types of cases; namely, (1) a “With Experiment” case that mimics the operations that actually occurred and (2) a “Without Experiment” case that simulates operations under the assumption that the HFE did not occur. The “With Experiment” case mimics operations during the HFE and the entire month the HFE occurred. It complies with LTEMP hourly and daily operating criteria. The “Without Experiment” case assumes that the HFE did not occur. The monthly water release volume is assumed to be identical under both cases. The Colorado River Storage Project Python-based model (CRiSPPy) model was the main modeling tool used to simulate the dispatch of the GCD hydropower plant and associated water releases from Lake Powell. In the modeling process, the research team used extensive data sets and historical information on SLCA/IP power plant characteristics, hydrologic conditions, and WAPA’s power purchases and sales prices. In addition to estimating the financial impact of the HFE, the team used the CRiSPPy model to gain insights into the interplay among ROD operating criteria, exceptions made to criteria to accommodate the HFE, and WAPA operating practices.

13 HYDRO ENERGY↗

Financial Analysis of the Smallmouth Bass Flows implemented at the Glen Canyon Dam during Water Year 2024

The Glen Canyon Dam (GCD) is a Colorado River Storage Project (CRSP) power resource that is a component of the Salt Lake City Area Integrated Projects (SLCA/IP). The 2016 record of decision (ROD) for the GCD long-term experimental and management plan (LTEMP) final Environmental Impact Statement (EIS) specifies criteria for GCD monthly water releases, daily and hourly operating limits, and experimental releases. This report presents a financial analysis of the Smallmouth bass (Micropterus dolomieu) (SMB) flows implemented at GCD during Water Year (WY) 2024. These bypass flows were introduced by the U.S. Bureau of Reclamation (USBR) as an emergency response to the growing threat posed by invasive SMB in the Colorado River ecosystem downstream of the dam. SMB are a non-native predatory species that pose a significant threat to native fish populations, including the endangered humpback chub (Gila cypha). The thermal regime below GCD, typically cold due to hypolimnetic releases from Lake Powell, has historically served as a thermal barrier limiting SMB establishment. However, persistently low reservoir levels in recent years have reduced stratification in Lake Powell, allowing warmer water to be released downstream. This has enabled SMB to spawn successfully below the dam, prompting urgent ecological concerns. To mitigate the risk of SMB proliferation, the USBR implemented a series of bypass flows in WY 2024. Drawn from a lower elevation than the penstocks, the bypass structures released cooler water downstream. These short-duration bypass flows aimed to keep temperatures cool enough to prevent SMB from spawning, thereby reducing the ecological threat posed by this invasive species. Although motivated by ecological objectives, these bypass flows came with financial tradeoffs. Releasing water through the bypass structures instead of the turbines at GCD reduced hydropower generation, resulting in a significantly lower financial position for Western Area Power Administration (WAPA), which is responsible for marketing the electricity produced by the GCD Powerplant. This report analyzes the financial impact of the SMB flows implemented from July to November 2024. These experimental releases led to an estimated financial cost of approximately $18.9 million, primarily driven by the substantial volume of water diverted through the bypass structures. This study applies an integrated set of tools to estimate WAPA financial impacts by simulating GCD under two types of cases; namely, (1) a “With Experiment” case that mimics the water operations that actually occurred, including the SMB bypass flows, and (2) a “Without Experiment” case that simulates operations under the assumption that the SMB flows did not occur. Both cases comply with LTEMP hourly and daily operating criteria, and the monthly water release volumes are assumed to be identical under both cases. The Colorado River Storage Project Python-based model (CRiSPPy) model was the main modeling tool used to simulate the dispatch of the GCD hydropower plant and associated water releases from Lake Powell. In the modeling process, the research team used extensive data sets and historical information on SLCA/IP power plant characteristics, hydrologic conditions, and WAPA’s power purchases and sales prices.

13 HYDRO ENERGY↗

Final Report for ARPA-E LOCOMOTIVES Advanced Locomotive Technology and Rail Infrastructure Optimization System (ALTRIOS) Project

The Advanced Locomotive Technology and Rail Infrastructure Optimization System (ALTRIOS) is a unique, fully integrated, open-source software tool used to evaluate strategies for cost-effectively deploying advanced locomotive technologies and associated infrastructure. ALTRIOS simulates freight-demand-driven train scheduling, mainline meet-pass planning, locomotive dynamics, train dynamics, energy conversion efficiencies, and energy storage dynamics of line-haul train operations. Because new locomotives represent a significant long-term capital investment and new technologies must be thoroughly demonstrated before deployment, this tool provides guidance on the risk/reward trade-offs and operation integration of different technology rollout strategies. An open, integrated simulation tool is valuable for identifying future research needs and making decisions on technology development, routes, and train selection. This final report details the ALTRIOS software architecture, major modules and components, and data validation process. It demonstrates the software's utility through a 30-year rollout case study targeting high penetration of advanced powertrain technologies by 2050 for two BNSF Railway routes: loaded taconite ore trains from Hibbing, Minnesota, to Superior, Wisconsin, and mixed-freight trains from Superior to Minneapolis, Minnesota.

33 ADVANCED PROPULSION SYSTEMS↗

Coupled Hydromechanical Modeling and Assessment of Induced Seismicity at FWU: Utilizing Time-Lapse VSP and Microseismic Data

The objective of this work is to utilize integrated geomechanics, field vertical seismic profile (VSP) and microseismic data to characterize the complex subsurface stress conditions at the Farnsworth Unit (FWU). The model is based on a five-spot sector model extracted from a primary geomechanical model. The five-spot well injection pattern is characterized by extensive reservoir characterization data, such well logs, extracted cores and borehole geophone data, to facilitate the detailed examination of stress changes and microseismic event occurrences. The study utilizes field vertical seismic volumes acquired from the injection well 13-10A. The seismic volumes successfully provided snapshots of the behavior of the reservoir at distinct times. The use of VSP and microseismic data provided direct and indirect estimates of the dynamic stress changes occurring in the overburden, reservoir and underburden rock formations. In order to illuminate the stress regions and identify rocks that have undergone inelastic failure, microseismic event occurrences were utilized. Microseismic activity has been detected at the FWU; further study of its locations, timing, and magnitude was needed to deduce the nature of the changing stress state. The results of the study revealed that microseismic events were successfully modeled within the Morrow B formation. Moment magnitudes of seismic events were within the same magnitudes for events in the reservoir, suggesting the suitability of the model. The results of the study showed that the computed moment magnitudes for seismic events were insignificant to warrant safety concerns. The study findings showed the usefulness of coupled hydromechanical models in predicting the subsurface stress changes associated with CO 2 injection. The knowledge gained from this study will serve as a guideline for industries planning to undertake underground CO 2 storage, and characterize the subsurface stress changes.

02 PETROLEUM↗

Field expedient stool collection methods for gut microbiome analysis in deployed military environments

ABSTRACT Field expedient devices and protocols for the collection, storage, and shipment of stool samples in deployed settings are needed for the advancement of microbiome research in military health. Relevant assessments include the evaluation of microbiome signatures associated with susceptibility to travelers’ diarrhea and recovery of gut function following infection. However, inherent biases in microbial measurements due to preservatives and sampling methods are unclear and should be assessed for an accurate evaluation of the microbiome. We performed shotgun metagenomic sequencing and compared the microbiome composition in paired fecal samples collected using Flinters Technology Associates (FTA) cards and OMNIgene (OG) Gut tubes, prior to and during international travel, from 49 adult participants, 39 of whom remained asymptomatic and 10 experienced travelers’ diarrhea. Higher concentrations of nucleic acid and sequencing libraries were observed in OG samples. A majority of genera (82.9%) were detected with both methods, and detections of genera limited to one collection method were not highly prevalent across samples and were present in extremely low relative abundances (<0.01%). Differences in beta diversity were largely explained by inter-individuality of microbiome composition, followed by the effect of collection method and timepoint-disease states. Differential abundance analysis indicated that Corynebacterium and Blautia were consistently higher in abundance across all groups with FTA and OG collection, respectively. The observed differences in microbiome composition between methods suggest the need for consistent and standardized protocols within a study. Overall, the data presented here could help guide the future design of fecal microbiome study protocols in field and military deployment settings. IMPORTANCE The assessment of field-deployable methods for fecal sample collection and storage is required to reliably capture samples collected in remote and austere locations. This study describes a comparative metagenomics analysis between samples collected by two different commercially available methods in a military-deployed setting. The results presented here are foundational for the future design of fecal microbiome study protocols in an operational context.

field study↗

Development of the 3 m{sup 3} Low Level Radioactive Waste Container in Taiwan - 20037

Chinshan Nuclear Power Plant stopped its business operation in July, 2019, and Kuosheng Nuclear Power Plant will also be permanently shut down in 2023. Nuclear Reactor Facilities Regulation Act requires a nuclear facility must be dismantled in 25 years after being permanently ceased operation. According to the approved decommissioning plan of Chinshan Nuclear Power Plant and the proposed one of Kuosheng Nuclear Power Plant, the 3 m{sup 3} low level radioactive waste container is planned to store the low level radioactive wastes with higher radiation produced during the decommissioning. However, 3 m{sup 3} low level radioactive waste containers are not used or developed in Taiwan before. To meet such need, Institute of Nuclear Energy Research develops a new type of 3 m{sup 3} low level radioactive waste container and performs the corresponding analyses and tests based on Guidelines of Applying the Usage License of Low Level Radioactive Waste Containers and Regulations for the Safe Transport of Radioactive Material. In this article, it provides the information of the low level radioactive waste containers that have been approved or is under reviewing in Taiwan, and so do the design specifications of the developed 3 m{sup 3} waste container. Besides, the numerical evaluation and test results of the developed 3 m{sup 3} waste container are also included in this article. Based on the evaluation and test results, the developed 3 m{sup 3} waste container satisfies the requirements of the storage container and industrial package type 2. Institute of Nuclear Energy Research will submit the usage license applications to the authority this year, and the usage licenses would be granted in 2021, expectedly. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anion Association Strength as a Unifying Descriptor for the Reversibility of Divalent Metal Deposition in Nonaqueous Electrolytes

Developing next-generation battery chemistries that move beyond traditional Li-ion systems is critical to enabling transformative advances in electrified transportation and grid-level energy storage. Here, we provide the first evidence for common descriptors for improved reversibility of metal plating/stripping in nonaqueous electrolytes for multivalent ion batteries. Focusing first on the specific role of chloride (Cl – ) in promoting electrochemical reversibility in multivalent systems, rotating disk (RDE) and ring-disk electrode (RRDE) investigations were performed utilizing a variety of divalent cations (Mg 2+ , Zn 2+ , and Cu 2+ ) and the bis-(trifluoromethane sulfonyl) imide (TFSI – ) anion. By introducing varying concentrations of Cl – , a cooperative effect is observed between TFSI – and Cl – that yields the more reversible behavior of mixed electrolytes relative to electrolytes containing only TFSI – . This effect is shown to be general for Mg, Zn, and Cu electrodeposition, and mechanistic understanding of the role of Cl – in improving reversibility of TFSI-based electrolytes is obtained through the combination of R(R)DE experimental results and density functional theory (DFT) evaluation of the redox activity and thermodynamic stability of various TFSI- and Cl-based solution complexes of metal ions. The cooperative anion effect is further generalized to other mixed-anion systems, where systematic variations in anion association strength predicted from DFT (i.e., Cl – > OTf – ≈ TFSI – > BF 4 – > PF 6 – ) yield corresponding trends in redox potentials and improvements of ≥200 mV in the reversibility of metal deposition/dissolution. These results identify anion association strength as a common descriptor for the reversibility of divalent metal anodes and suggest a set of general design principles for developing new electrolytes with improved activity and stability.

25 ENERGY STORAGE↗

On the role of Battery Energy Storage Systems in the day-ahead Contingency-Constrained Unit Commitment problem under renewable penetration

The integration of variable Renewable Energy Sources (vRES) to alleviate greenhouse gas emissions has introduced significant challenges for power systems operations. These challenges include high levels of uncertainty due to the intermittence associated with vRES and therefore impose the need to devise a reliable and cost-effective day-ahead unit commitment and power and reserves scheduling for real-time operations. Also, this increasing penetration of vRES requires higher ramping capabilities from units originally designed for other purposes (e.g., base-load generation), which might be exacerbated during contingency states. Hence, in this work, we propose a methodology to address the day-ahead Contingency-Constrained Unit Commitment (CCUC) problem that leverages the participation of Battery Energy Storage Systems (BESSs) to address load-following and post-contingency management, therefore alleviating the ramping burden on conventional thermal generators. To do so, we formulate a three-level optimization problem that represents the decision-making process of obtaining the least-cost commitment, generation and reserves scheduling, while restricting the Conditional Value-at-Risk (CVaR) of the system imbalance at real-time operations to user-defined tolerance levels. In addition, we devise a computationally efficient solution approach for the proposed problem based on the Column-and Constraint Generation (CCG) algorithmic framework. Two numerical experiments are conducted to empirically illustrate the benefits of the proposed methodology. Key results indicate a reduction in real-time ramping needs and a better usage of the system resources, with a reduction in the overall system commitment levels and reserve scheduling costs when compared to a benchmark case in which storage is not available.

Moreira, Alexandre↗

Solar and Storage Integration in the U.S. Southeast: Implications for Resource Adequacy

Resource adequacy concerns may be very different in electricity systems that have higher levels of solar and storage, requiring changes to existing planning models. This study explores a novel approach to evaluating resource adequacy under future scenarios with higher solar and storage in the Southeast U.S. It uses NREL’s Probabilistic Resource Adequacy Suite (PRAS), a collection of probabilistic resource adequacy modeling tools, and compares results when interacting PRAS and a portfolio planning tool with a more traditional modeling approach. The results suggest that traditional models perform reasonably well with lower levels of solar PV, but at higher levels of solar probabilistic tools better capture the changes in resource adequacy concerns—such as winter energy availability—associated with higher solar systems. This is the final study in the Preparing Southeast Markets for Reliable and Affordable Integration of Solar into Operations and Planning project. Two prior reports can be found at: Solar and Storage Integration in the Southeastern United States: Economics, Reliability, and Operations. https://emp.lbl.gov/publications/solar-and-storage-integration Solar and Wind Forecast Error Reserve Sharing in a Multi-Utility Region. https://eta-publications.lbl.gov/sites/default/files/2024-11/multiutility_fe_reserve_sharing_final.pdf

14 SOLAR ENERGY↗

Renewable-Storage Hybrids in a Decarbonized Electricity Supply

We explore the potential impacts of growing industry interest in hybrid systems comprising PV and battery technologies on the results and findings of the Solar Futures Study (2021). Through comparison of Solar Futures Study scenarios with and without PV-battery hybrid configurations enabled (in the same grid planning model), we find that the highest net-value hybrid configuration depends strongly on power sector carbon policy, which increases the value of more forward-looking designs. While the availability of PV-battery hybrid configurations primarily displaces standalone PV and battery capacity, we find that it (a) increases solar's share of total capacity and generation and (b) reduces required transmission expansion and associated costs under scenarios that combine aggressive cost reductions and power sector decarbonization policy. Results will also be presented for the complementarity and economic value of wind-PV hybrids with varying amounts of energy storage.

complementarity↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, construction, and validation of an in-situ groundwater trace element analyzer with applications in carbon storage

Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.

54 ENVIRONMENTAL SCIENCES↗

Verification of numerical models for seismic fluid-structure interaction analysis of internal components in liquid-filled advanced reactors

Earthquake shaking of a liquid-filled advanced reactor induces fluid-structure interaction (FSI) between the reactor vessel (tank), its internal components, and the contained liquid. Seismic design, qualification, and risk assessment of such reactors must consider fluid-structure responses, their geometries and support conditions, and three-directional seismic inputs, all of which require numerical simulations. Numerical models used for analysis of safety-related nuclear equipment must be verified and validated. Here, this paper verifies numerical models of submerged components using analytical solutions. Seismic FSI analysis of the numerical models is performed using the Arbitrary Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD) solvers in LS-DYNA. Prior analytical solutions are reworked in this paper, and calculation errors are identified and corrected. The solutions address frequencies of two concentric cylindrical pipes filled with liquid: the inner pipe is a submerged component, and the outer pipe contains the liquid. A unitless frequency coefficient is defined and presented for pipes of different materials, filled with different liquids, and with a range of dimensions for application to advanced reactors. The numerical models are verified here by comparing the lateral frequencies of submerged components with those calculated using the corrected analytical solutions. Recommendations for verification of numerical models of internal components in advanced reactors for seismic FSI analysis are provided. Although the unitless frequency coefficients and verification procedures are developed for application to advanced nuclear reactors, they are broadly applicable to FSI analysis of submerged components in liquid-filled vessels such as storage tanks, boilers, and steam generators.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electric vehicle post-crash Recovery—Stranded energy issues and mitigation strategy

In post-crash situations, passengers, bystanders, and first responders are exposed to the immediate safety risks of stranded energy in electric vehicle (EV) batteries. Stranded energy is the energy remaining inside any undamaged or damaged battery following an accident. A potentially damaged battery with an unknown state of safety might go into thermal runaway in the absence of proper monitoring, diagnostics, controls, and handling—thereby leading to potential loss of life and property damage. Therefore, it is imperative to develop standard guidelines, diagnostic methods, and tools to handle stranded energy appropriately and minimize safety risks from immediately after an EV accident to final disposal or re-entry to the road. This perspective paper identifies the challenges associated with handling stranded energy and proposes some potential solution pathways. Further, we hope to draw attention of the research and development community, original equipment manufacturers, and policymakers for motivating new insights and research needs in mitigating safety implications associated with stranded energy.

25 ENERGY STORAGE↗

Assessing Suitable Geologic Carbon Storage Sites Across Utah

Utah has a wealth of potential geological reservoirs for carbon dioxide storage (CS) and a long history of geologic research resulting in an abundance of available subsurface data to evaluate CS potential. Reservoirs may include sandstone, carbonate, and basalt; these rock types are plentiful in Utah’s subsurface and the complex Phanerozoic history throughout the state requires evaluating each geologic region individually for promising reservoir-seal pairs for CO2 storage. Classifying Utah by geologic provinces (or “geo-regions”) allows for customized thinking about suitable CS reservoir and seal distribution, CO2 point sources, land use, and existing infrastructure. Preliminary results from this study highlight the geologic CS potential across 15 geo-regions. Four regions stand out as having high CS potential: the Uinta Basin, San Rafael Swell, Paradox Basin, and the southern Basin and Range Province. The Uinta Basin and San Rafael Swell geo-regions are well suited for CS and have several projects ongoing to evaluate Cretaceous Frontier and Naturita Formations, Jurassic Navajo Sandstone and Entrada Sandstone, and Permian Weber Sandstone reservoir units that lie beneath robust sealing units like the ~5000-ft-thick Mancos Shale and Carmel Formation. Reservoirs such as the Navajo and Weber Sandstones have been demonstrated to be suitable reservoirs through a long history of oil and gas exploration in Utah. New areas of interest include the southern Basin and Range in southwest Utah, where the Jurassic Navajo Sandstone is overlain by the sealing Carmel Formation at suitable depths (>3000 ft), and has good porosities based on outcrop analogue data. Just to the north (e.g., central Basin and Range), legacy wells and 2D seismic data show possible salt and subsurface basalt flows that may provide additional possible CS reservoirs and seals. This geo-region also has the advantage of being coupled with geothermal energy resources that may be used to power burgeoning direct air capture technologies. In the Paradox Basin of southeastern Utah, the Leadville Limestone is a potential storage reservoir beneath the thick (4000–5000 ft), salt-bearing Pennsylvanian Paradox Formation. Although the northern and western parts of Utah offer CS potential, these areas typically contain less infrastructure and subsurface penetrations, creating geologic uncertainty associated with subsurface seals and reservoirs due to a lack of data. Overall, this statewide assessment and ranking is the first step to aid in evaluating CS potential across Utah and provides a foundation for future research in the most favorable locations.

58 GEOSCIENCES↗

Smart Composite Pressure Vessels (SCPV) with Integrated Health Monitoring

The U.S. Department of Energy (DOE) is promoting and developing more energy efficient and environmentally friendly technologies that will enable America to use less petroleum. Hydrogen fuel cells – which directly convert the chemical energy in hydrogen to electricity with only water and heat as byproducts – are a very attractive solution that can enable this to happen. To date, DOE's efforts have culminated in commercial demonstration of on-board vehicular hydrogen storage systems that can allow for a driving range of greater than 300 miles. This requires storing 5 Kgs of hydrogen onboard a light vehicle. In order to store this quantity of hydrogen, the hydrogen gas needs to be stored in a composite overwrapped pressure vessel (COPV) at a very high internal pressure. The objective of the program was to demonstrate continuous and predictable health-monitoring of composite pressure vessels. A higher confidence in the operational safety of the vessels will lead to reduced burst factor of safety imposed by regulatory standards and hence will help reduce the structural wall thickness that drives the cost of the vessel. Highly optimized Type III (metal lined) and Type IV (polymer lined) COPVs that are manufactured using filament winding process have been designed and qualified for the above mentioned application. However, the main structural component of the COPVs is carbon fiber and the high cost of carbon fiber composite in a pressure vessel is a primary challenge in reducing the cost of gaseous hydrogen storage. Continuous and remote monitoring of structural health of the COPVs as well as optimization of the strength translation of carbon fibers have the potential to allow for reduced factor of safety, thereby reduced amount of carbon and associated cost of the vessel. In the current program, the project team including Steelhead Composites (SHC), University of Tennessee, Knoxville (UTK), Teijin Carbon America, Oak Ridge National Laboratory (ORNL) and LUNA designed, fabricated, and tested smart composite pressure vessels with integrated sensors. Iterative loops of design and testing using coupons, subscale STEB vessels and full size vessels proved that a new generation of high performance carbon fiber can be used for efficient design of Type 3 vessels for H2 storage. Novel analysis techniques were developed to predict the initiation and propagation of interlaminar damage inside the composite shell due to impact damage, a real threat in practical operation. Such an analysis scheme is typically not used in tank design but is an essential tool for health monitoring of composite vessels. Remote sensing of the key signatures of the tank’s operating parameters such as pressure, acceleration and humidity was demonstrated using a unique device that can wirelessly transmit and stream the data to a remote server. Fiber optic sensors were successfully integrated during fabrication of the tanks. These sensors provide a wealth of information regarding the structural health of the vessel when it is subsequently pressurized or subjected to impact damage. Excellent correlation was demonstrated between the fiber optic sensor and mechanical strain gage data, and between the measurements and analytical predictions.

08 HYDROGEN↗