Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Development Of Ion Chromatography Methods To Support Testing Of The Glycolic Acid Reductant Flowsheet In The Defense Waste Processing Facility

Ion Chromatography (IC) is the principal analytical method used to support studies of Sludge Reciept and Adjustment Tank (SRAT) chemistry at DWPF. A series of prior analytical ''Round Robin'' (RR) studies included both supernate and sludge samples from SRAT simulant, previously reported as memos, are tabulated in this report.2,3 From these studies it was determined to standardize IC column size to 4 mm diameter, eliminating the capillary column from use. As a follow on test, the DWPF laboratory, the PSAL laboratory, and the AD laboratory participated in the current analytical RR to determine a suite of anions in SRAT simulant by IC, results also are tabulated in this report. The particular goal was to confirm the laboratories ability to measure and quantitate glycolate ion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Asymptotic solution for heat convection-radiation equation

In this paper, we employ a new approximate analytical method called the optimal homotopy asymptotic method (OHAM) to solve steady state heat transfer problem in slabs. The heat transfer problem is modeled using nonlinear two-point boundary value problem. Using OHAM, we obtained the approximate analytical solution for dimensionless temperature with different values of a parameter ε. Further, the OHAM results for dimensionless temperature have been presented graphically and in tabular form. Comparison has been provided with existing results from the use of homotopy perturbation method, perturbation method and numerical method. For numerical results, we used Runge-Kutta Fehlberg fourth-fifth order method. It was found that OHAM produces better approximate analytical solutions than those which are obtained by homotopy perturbation and perturbation methods, in the sense of closer agreement with results obtained from the use of Runge-Kutta Fehlberg fourth-fifth order method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative investigations of multi-fidelity modeling on performance of electrostatically-actuated cracked micro-beams

Silicon is a commonly used material for the fabrication of beams for use in micro-electrical-mechanical systems (MEMS). Although silicon is a brittle material, it has been shown to accumulate fatigue damage at the micro-scale. Understanding the effect this has on the overall device performance is critical to the design of reliable devices. Analytical methods for modeling damage provide expedient results but are limited by broad modeling assumptions. Numerical models account for more detailed physical phenomena but can be computationally intensive. In this work, two different crack scenarios are modeled using both analytical techniques and 3D computational simulations. First, the effects of a single surface crack on the static deflection and natural frequency of an electrostatically actuated micro-beam are formulated and compared. Then, a new method for approximating damage associated with realistic distributed crack networks is formulated for use in an analytical model and numerical simulations. A method for utilizing experimentally derived crack statistics to inform the analytical and numerical distributed crack models is developed. Good agreement between the analytical and numerical models is obtained for both crack scenarios. Altogether, these models can be used to effectively simulate a variety of damage and fatigue behaviors in silicon-based MEMS devices.

42 ENGINEERING↗

Evaluation of available analytical techniques for monitoring the quality of space station potable water

To assure the quality of potable water (PW) on the Space Station (SS) a number of chemical and physical tests must be conducted routinely. After reviewing the requirements for potable water, both direct and indirect analytical methods are evaluated that could make the required tests and improvements compatible with the Space Station operation. A variety of suggestions are made to improve the analytical techniques for SS operation. The most important recommendations are: (1) the silver/silver chloride electrode (SB) method of removing I sub 2/I (-) biocide from the water, since it may interfere with analytical procedures for PW and also its end uses; (2) the orbital reactor (OR) method of carrying out chemistry and electrochemistry in microgravity by using a disk shaped reactor on an orbital table to impart artificial G force to the contents, allowing solution mixing and separation of gases and liquids; and (3) a simple ultra low volume highly sensitive electrochemical/conductivity detector for use with a capillary zone electrophoresis apparatus. It is also recommended, since several different conductivity and resistance measurements are made during the analysis of PW, that the bipolar pulse measuring circuit be used in all these applications for maximum compatibility and redundancy of equipment.

Geer, Richard D.↗

WE-G-BRE-06: New Potential for Enhancing External Beam Radiotherapy for Lung Cancer Using FDA-Approved Concentrations of Cisplatin Or Carboplatin Nanoparticles Administered Via Inhalation

Purpose: This study investigates, for the first time, the dose enhancement to lung tumors due to cisplatin nanoparticles (CNPs) and carboplatin nanoparticles (CBNPs) administered via inhalation route (IR) during external beam radiotherapy. Methods: Using Monte Carlo generated 6 MV energy fluence spectra, a previously employed analytic method was used to estimate dose enhancement to lung tumor due to radiation-induced photoelectrons from CNPs administered via IR in comparison to intravenous (IV) administration. Previous studies have indicated about 5% of FDA-approved cisplatin concentrations reach the lung tumor via IV. Meanwhile recent experimental studies indicate that 3.5–14.6 times higher concentrations of CNPs can reach the lung tumors by IR compared to IV. Taking these into account, the dose enhancement factor (DEF) defined as the ratio of the dose with and without CNPs was calculated for field size of 10 cm × 10 cm (sweeping gap), for a range of tumor depths and tumor sizes. Similar calculations were done for CBNPs. Results: For IR with 3.5 times higher concentrations than IV, and 2 cm diameter tumor, clinically significant DEF values of 1.19–1.30 were obtained for CNPs at 3–10 cm depth, respectively, in comparison to 1.06–1.09 for IV. For CBNPs, DEF values of 1.26–1.41 were obtained in comparison to 1.07–1.12 for IV. For IR with 14.6 times higher concentrations, higher DEF values were obtained e.g. 1.81–2.27 for CNPs. DEF increased with increasing field size or decreasing tumor size. Conclusions: Our preliminary results indicate that major dose enhancement to lung tumors can be achieved using CNPs/CBNPs administered via IR, in contrast to IV administration during external beam radiotherapy. These findings highlight a potential new approach for radiation boosting to lung tumors using CNPs/CBNPs administered via IR. This would, especially, be applicable during concomitant chemoradiotherapy, potentially allowing for dose enhancement while minimizing normal tissue toxicities.

60 APPLIED LIFE SCIENCES↗

Simulated 'On-Line' Wear Metal Analysis of Lubricating Oils by X-Ray Fluorescence Spectroscopy

The objective of this project was to assess the sensitivity of X-ray Fluorescence Spectroscopy (XFS) for quantitative evaluation of metal particle content in engine oil suspensions and the feasibility of real-time, dynamic wear metal analysis. The study was focused on iron as the majority wear metal component. Variable parameters were: particle size, particle concentration and oil velocity. A commercial XFS spectrometer equipped with interchangeable static/dynamic (flow cell) sample chambers was used. XFS spectra were recorded for solutions of Fe-organometallic standard and for a series of DTE oil suspensions of high purity spherical iron particles of 2g, 4g, and 8g diameter, at concentrations from 5 ppm to 5,000 ppm. Real contaminated oil samples from Langley Air Force Base aircraft engines and NASA Langley Research Center wind tunnels were also analyzed. The experimental data conform the reliability of XFS as the analytical method of choice for this project. Intrinsic inadequacies of the instrument for precise analytic work at low metal concentrations were identified as being related to the particular x-ray beam definition, system geometry, and flow-cell materials selection. This work supports a proposal for the design, construction and testing of a conceptually new, miniature XFS spectrometer with superior performance, dedicated to on-line, real-time monitoring of lubricating oils in operating engines. Innovative design solutions include focalization of the incident x-ray beam, non-metal sample chamber, and miniaturization of the overall assembly. The instrument would contribute to prevention of catastrophic engine failures. A proposal for two-year funding has been presented to NASA Langley Research Center Internal Operation Group (IOG) Management, to continue the effort begun by this summer's project.

Kelliher, Warren C.↗

Supplement: The Rate of Binary Black Hole Mergers Inferred from Advanced LIGO Observations Surrounding GW150914

This article provides supplemental information for a Letter reporting the rate of (BBH) coalescences inferred from 16 days of coincident Advanced LIGO observations surrounding the transient (GW) signal GW150914. In that work wereported various rate estimates whose 90% confidence intervals fell in the range 2600 Gpc(exp -3) yr(exp -1). Here we givedetails on our method and computations, including information about our search pipelines, a derivation of ourlikelihood function for the analysis, a description of the astrophysical search trigger distribution expected frommerging BBHs, details on our computational methods, a description of the effects and our model for calibrationuncertainty, and an analytic method for estimating our detector sensitivity, which is calibrated to our measurements.

gravitational waves – stars: black holes↗

Analysis of the nuclear measurement program for an optimized BR2 core configuration

This paper presents the analysis of the results of the Nuclear Measurement Program (NMP) executed during the shut-down of cycle 05/2012 of the BR2 reactor. The aim of the NMP was to determine the properties of a reactor core load with a new configuration of the control rods and to evaluate/verify the predicted numerical results by MCNPX. The methods used for the interpretation of the measurement results include combinations of an analytical method for determination of the axial relative control rod efficiency and least square techniques. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Progressive damage, fracture predictions and post mortem correlations for fiber composites

Lewis Research Center is involved in the development of computational mechanics methods for predicting the structural behavior and response of composite structures. In conjunction with the analytical methods development, experimental programs including post failure examination are conducted to study various factors affecting composite fracture such as laminate thickness effects, ply configuration, and notch sensitivity. Results indicate that the analytical capabilities incorporated in the CODSTRAN computer code are effective in predicting the progressive damage and fracture of composite structures. In addition, the results being generated are establishing a data base which will aid in the characterization of composite fracture.

Source record↗

In Vitro Assessment of the In Vivo Stability of Cu-64 Radiopharmaceuticals

Research Plans: The successful development of Cu-64 radiopharmaceuticals depends upon retention of the Cu-64 atom in the radiopharmaceutical. To date, the focus has been on the development of chelators that better retain Cu-64, but there has been no effort to develop an effective method by which improved retention may be measured. In the absence of a suitable analytical method, the stability of Cu-64 radiopharmaceuticals is estimated indirectly, with decreased liver uptake suggesting higher in vivo complex stability. But this approach is inadequate for radiopharmaceuticals, such as radiolabeled antibodies, that are expected to accumulate in the liver even when there is no free Cu-64 present. The absence of such a method has also hampered efforts to systematically evaluate the chemical factors that may give rise to improved retention. The objective of this project is to develop and validate such a method. Accomplishments: The two primary accomplishments of this project will be 1) the development and validation of a method to measure the stability of Cu-64 radiopharmaceuticals and 2) the determination of the chemical factors that define the in vivo stability of Cu 64 radiopharmaceuticals. Because Cu(II) is extremely labile, the in vivo stability of Cu-64 radiopharmaceuticals is not primarily determined by the amount of free Cu that is present at any given time or by the thermodynamic stability constants, but rather by the rate at which Cu is lost from the complex, the dissociation rate constant, kd. The dissociation rate constants of the Cu-64 complexes from a series of bifunctional chelators (BFCs) will be measured using Free Ion Selective Radiotracer Extraction (FISRE), a technique originally developed to measure bioavailable Cu in environmental samples. FISRE will also be applied to the determination of the kd's of a series of reference Cu-64 complexes to determine the chemical factors that define the in vivo stability of Cu-64 radiopharmaceuticals. Potential Benefits: The FISRE method that will be used in this project, once validated, will provide researchers with a core technology by which the stability of Cu 64 radiopharmaceuticals can be accurately measured. In the short-term, we expect to produce extensive data regarding the stability of Cu-64 complexes of ligands of radiopharmaceutical interest, primarily those that are most commonly used as BFCs (e.g., DOTA, TETA). These data will provide a quantitative basis for deciding which ligands may be best suited for use as BFCs, data that is not currently available. In the intermediate term, we expect that these results will facilitate the development of new Cu-64 radiopharmaceuticals by providing a quantitative approach to assessing the stability of Cu-64 chelates. This innovative methodology will enable investigators to quantitatively compare the ability of different BFCs to retain Cu-64 in vivo. The benefits of this approach will be best seen in the development of Cu-64-labeled monoclonal antibodies where the accumulation of antibodies in the liver obviates liver uptake as an effective surrogate measure of Cu-64 lability. In the longer-term, we anticipate an improvement in the way in which various diseases (especially cancer) are detected, diagnosed, staged, and treated. This method will also enable researchers to distinguish differences in biodistribution that may arise from differences in charge, lipophilicity, etc. from those that may arise from loss of Cu-64 from the chelator. Last, this novel quantitative tool will allow investigators to evaluate the chemical factors that determine the in vivo stability of Cu-64 radiopharmaceuticals laying the groundwork for the future development of more effective Cu-64 radiopharmaceuticals. Once the feasibility of this method is established, it can also be used to evaluate the stability of other metalloradiopharmaceuticals including those based on Ga-68, a radionuclide that is showing great promise in tumor imaging.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

SUPPLEMENT: “THE RATE OF BINARY BLACK HOLE MERGERS INFERRED FROM ADVANCED LIGO OBSERVATIONS SURROUNDING GW150914” (2016, ApJL, 833, L1)

This article provides supplemental information for a Letter reporting the rate of (BBH) coalescences inferred from 16 days of coincident Advanced LIGO observations surrounding the transient (GW) signal GW150914. In that work we reported various rate estimates whose 90% confidence intervals fell in the range 2–600 Gpc{sup −3} yr{sup −1}. Here we give details on our method and computations, including information about our search pipelines, a derivation of our likelihood function for the analysis, a description of the astrophysical search trigger distribution expected from merging BBHs, details on our computational methods, a description of the effects and our model for calibration uncertainty, and an analytic method for estimating our detector sensitivity, which is calibrated to our measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

A method for calculating strut and splitter plate noise in exit ducts: Theory and verification

Portions of a four-year analytical and experimental investigation relative to noise radiation from engine internal components in turbulent flow are summarized. Spectra measured for such airfoils over a range of chord, thickness ratio, flow velocity, and turbulence level were compared with predictions made by an available rigorous thin-airfoil analytical method. This analysis included the effects of flow compressibility and source noncompactness. Generally good agreement was obtained. This noise calculation method for isolated airfoils in turbulent flow was combined with a method for calculating transmission of sound through a subsonic exit duct and with an empirical far-field directivity shape. These three elements were checked separately and were individually shown to give close agreement with data. This combination provides a method for predicting engine internally generated aft-radiated noise from radial struts and stators, and annular splitter rings. Calculated sound power spectra, directivity, and acoustic pressure spectra were compared with the best available data. These data were for noise caused by a fan exit duct annular splitter ring, larger-chord stator blades, and turbine exit struts.

Fink, M. R.↗

Comparison of elastic and elastic-plastic structural analyses for cooled turbine blade airfoils

Elastic plastic stress strain states in cooled turbine blade airfoils were calculated by three methods for the initial takeoff transient of an advanced technology aircraft engine. The three analytical methods compared were a three dimensional elastic plastic, finite element analysis, a three dimensional, elastic, finite element analysis, and a one dimensional, elastic plastic, beam theory analysis. Structural analyses were performed for eight cases involving different combinations of mechanical and thermal loading on impingement cooled airfoils with and without leading edge film cooling holes. The von Mises effective total strains at maximum takeoff computed from the elastic and elastic plastic finite element analyses agreed with 9 percent for rotating airfoils and 28 percent for stationary airfoils with the elastic results on the conservative side.

Kaufman, A.↗

Integrated pilot - Optimal augmentation synthesis for complex flight vehicles: Experimental validation

The purpose of this work is to present an experimental validation via fixed-base simulation of analytical methods for predicting handling qualities of flight vehicles. Different augmented dynamics are considered and analytical predictions of performance and pilot rating obtained. A flight simulation is then performed and comparison between experiment and theoretical data is shown.

Innocenti, M.↗