Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Agree”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Time evolution of the luminosity of colliding heavy-ion beams in BNL Relativistic Heavy Ion Collider and CERN Large Hadron Collider

We have studied the time evolution of the heavy ion luminosity and bunch intensities in the Relativistic Heavy Ion Collider (RHIC), at BNL, and in the Large Hadron Collider (LHC), at CERN. First, we present measurements from a large number of RHIC stores (from Run 7), colliding 100 GeV/nucleon {sup 197}Au{sup 79}+ beams without stochastic cooling. These are compared with two different calculation methods. The first is a simulation based on multi-particle tracking taking into account collisions, intrabeam scattering, radiation damping, and synchrotron and betatron motion. In the second, faster, method, a system of ordinary differential equations with terms describing the corresponding effects on emittances and bunch populations is solved numerically. Results of the tracking method agree very well with the RHIC data. With the faster method, significant discrepancies are found since the losses of particles diffusing out of the RF bucket due to intrabeam scattering are not modeled accurately enough. Finally, we use both methods to make predictions of the time evolution of the future {sup 208}Pb+{sup 82+} beams in the LHC at injection and collision energy. For this machine, the two methods agree well.

43 PARTICLE ACCELERATORS↗

Structural implications of the C-terminal tail in the catalytic and stability properties of manganese peroxidases from ligninolytic fungi

The variable C-terminal tail of manganese peroxidases, a group of enzymes involved in lignin degradation, is implicated in their catalytic and stability properties, as shown by new crystal structures, molecular-simulation and directed-mutagenesis data. Based on this structural–functional evaluation, short and long/extralong manganese peroxidase subfamilies have been accepted; the latter are characterized by exceptional stability, while it is shown for the first time that the former are able to oxidize other substrates at the same site where manganese(II) is oxidized. The genome of Ceriporiopsis subvermispora includes 13 manganese peroxidase (MnP) genes representative of the three subfamilies described in ligninolytic fungi, which share an Mn{sup 2+}-oxidation site and have varying lengths of the C-terminal tail. Short, long and extralong MnPs were heterologously expressed and biochemically characterized, and the first structure of an extralong MnP was solved. Its C-terminal tail surrounds the haem-propionate access channel, contributing to Mn{sup 2+} oxidation by the internal propionate, but prevents the oxidation of 2, 2′-azino-bis(3-ethylbenzothiazoline-6-sulfonate) (ABTS), which is only oxidized by short MnPs and by shortened-tail variants from site-directed mutagenesis. The tail, which is anchored by numerous contacts, not only affects the catalytic properties of long/extralong MnPs but is also associated with their high acidic stability. Cd{sup 2+} binds at the Mn{sup 2+}-oxidation site and competitively inhibits oxidation of both Mn{sup 2+} and ABTS. Moreover, mutations blocking the haem-propionate channel prevent substrate oxidation. This agrees with molecular simulations that position ABTS at an electron-transfer distance from the haem propionates of an in silico shortened-tail form, while it cannot reach this position in the extralong MnP crystal structure. Only small differences exist between the long and the extralong MnPs, which do not justify their classification as two different subfamilies, but they significantly differ from the short MnPs, with the presence/absence of the C-terminal tail extension being implicated in these differences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The seventh blind test of crystal structure prediction: structure ranking methods

A seventh blind test of crystal structure prediction has been organized by the Cambridge Crystallographic Data Centre. The results are presented in two parts, with this second part focusing on methods for ranking crystal structures in order of stability. The exercise involved standardized sets of structures seeded from a range of structure generation methods. Participants from 22 groups applied several periodic DFT-D methods, machine learned potentials, force fields derived from empirical data or quantum chemical calculations, and various combinations of the above. In addition, one non-energy-based scoring function was used. Results showed that periodic DFT-D methods overall agreed with experimental data within expected error margins, while one machine learned model, applying system-specific AIMnet potentials, agreed with experiment in many cases demonstrating promise as an efficient alternative to DFT-based methods. For target XXXII, a consensus was reached across periodic DFT methods, with consistently high predicted energies of experimental forms relative to the global minimum (above 4 kJ mol −1 at both low and ambient temperatures) suggesting a more stable polymorph is likely not yet observed. The calculation of free energies at ambient temperatures offered improvement of predictions only in some cases (for targets XXVII and XXXI). Several avenues for future research have been suggested, highlighting the need for greater efficiency considering the vast amounts of resources utilized in many cases.

Chemistry↗

Cyber Norms for Civilian Nuclear Power Plants

The international community agrees that the safe operation of civilian nuclear infrastructure is in every population’s best interest. One challenge each government must address is defining and agreeing to a set of acceptable norms of behavior in cyberspace as they relate to these facilities. The introduction of digital systems and networking technologies into these environments has led to the possibility that control and supporting computer systems are now accessible and exploitable, especially where interconnections to global information and communications technology (ICT) networks exist. The need for norms of behavior in cyberspace includes what is expected of system architects and cyber defenders as well as adversaries who should abide by rules of engagement even while conducting acts that violate national and international laws. The goal of this paper is to offer three behavioral cyber norms to improve the overall security of the ICT and Operational Technology (OT) networks and systems that underlie the operations of nuclear facilities. These norms of behavior will be specifically defined with the goals of reducing the threats associated to the theft of nuclear materials, accidental release of radiation and sabotage of nuclear processes. These norms would also include instances where an unwitting attacker or intelligence collection entity inadvertently makes their way into a nuclear facility network or system and can recognize they are in a protected zone and an approach to ensuring that these zones are not exploitable by bad actors to place their sensitive cyber effect delivery systems.

99 GENERAL AND MISCELLANEOUS↗

Cloud-based Testbed for Adaptive Under-Frequency Load Shedding with High DER Penetration

Increasing penetration of distributed energy resources and behind-the-meter renewables may soon disrupt the efficacy of critical protection schemes, such as under-frequency load shedding (UFLS). Improved data exchange and coordination across the transmission-distribution boundary will be required to maintain reliability of bulk electric system. Standards-based data integration platforms using agreed-upon semantic vocabularies, such as the Common Information Model, will be key to enabling adaptive protection schemes requiring synthesized data from both the bulk power system and behind-the-meter resources. This paper introduces a cloud-based open-source data integration environment and UFLS clustering algorithm being developed to enable adaptive relay coordination between transmission and distribution utilities in the state of Vermont.

Anderson, Alexander A.↗

Evaluation and Field Assessment of Bifacial Photovoltaic Module Power Rating Methodologies

1-sun power ratings for bifacial modules are currently undefined. This is partly because there is no standard definition of rear irradiance given 1000 Wm-2 on the front. Using field measurements and simulations, we evaluate multiple deployment scenarios for bifacial modules and provide details on the amount of irradiance that could be expected. A simplified case that represents a single module deployed under conditions consistent with existing 1-sun irradiance standards leads to a bifacial reference condition of 1000 Wm-2 Gfront and 130-140 Wm-2 Grear. For fielded systems of bifacial modules, Grear magnitude and spatial uniformity will be affected by self-shade from adjacent modules, varied ground cover, and ground-clearance height. A standard measurement procedure for bifacial modules is also currently undefined. A proposed international standard is under development, which provides the motivation for this work. Here, we compare outdoor field measurements of bifacial modules with irradiance on both sides with proposed indoor test methods where irradiance is only applied to one side at a time. The indoor method has multiple advantages, including controlled and repeatable irradiance and thermal environment, along with allowing the use of conventional single-sided flash test equipment. The comparison results are promising, showing that the indoor and outdoor methods agree within 1%-2% for multiple rear-irradiance conditions and bifacial module types.

14 SOLAR ENERGY↗

Investigation of Theoretical Solutions to a Bottom-Raised Oscillating Surge Wave Energy Converter (OSWEC) Through Experimental and Parametric Studies

Experiments were conducted on a wave tank model of a bottom raised oscillating surge wave energy converter (OSWEC) model in regular waves. The OSWEC model shape was a thin rectangular flap, which was allowed to pitch in response to incident waves about a hinge located at the intersection of the flap and the top of the supporting foundation. Torsion springs were added to the hinge in order to position the pitch natural frequency at the center of the wave frequency range of the wave maker. The flap motion as well as the loads at the base of the foundation were measured. The OSWEC was modeled analytically using elliptic functions in order to obtain closed form expressions for added mass and radiation damping coefficients, along with the excitation force and torque. These formulations were derived and reported in a previous publication by the authors. While analytical predictions of the foundation loads agree very well with experiments, large discrepancies are seen in the pitch response close to resonance. These differences are analyzed by conducting a sensitivity study, in which system parameters, including damping and added mass values, are varied. The likely contributors to the differences between predictions and experiments are attributed to tank reflections, standing waves that can occur in long, narrow wave tanks, as well as the thin plate assumption employed in the analytical approach.

analytical↗

Analytic expressions for atomic layer deposition: Coverage, throughput, and materials utilization in cross-flow, particle coating, and spatial atomic layer deposition

In this work, the authors present analytic models for atomic layer deposition (ALD) in three common experimental configurations: cross-flow, particle coating, and spatial ALD. These models, based on the plug-flow and well-mixed approximations, allow us to determine the minimum dose times and materials utilization for all three configurations. A comparison between the three models shows that throughput and precursor utilization can each be expressed by universal equations, in which the particularity of the experimental system is contained in a single parameter related to the residence time of the precursor in the reactor. For the case of cross-flow reactors, the authors show how simple analytic expressions for the reactor saturation profiles agree well with experimental results. Consequently, the analytic model can be used to extract information about the ALD surface chemistry (e.g., the reaction probability) by comparing the analytic and experimental saturation profiles, providing a useful tool for characterizing new and existing ALD processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conduction and rectification in NbO{sub x}- and NiO-based metal-insulator-metal diodes

Conduction and rectification in nanoantenna-coupled NbO{sub x}- and NiO-based metal-insulator-metal (MIM) diodes (“nanorectennas”) are studied by comparing new theoretical predictions with the measured response of nanorectenna arrays. A new quantum mechanical model is reported and agrees with measurements of current–voltage (I–V) curves, over 10 orders of magnitude in current density, from [NbO{sub x}(native)-Nb{sub 2}O{sub 5}]- and NiO-based samples with oxide thicknesses in the range of 5–36 nm. The model, which introduces new physics and features, including temperature, electron effective mass, and image potential effects using the pseudobarrier technique, improves upon widely used earlier models, calculates the MIM diode's I–V curve, and predicts quantitatively the rectification responsivity of high frequency voltages generated in a coupled nanoantenna array by visible/near-infrared light. The model applies both at the higher frequencies, when high-energy photons are incident, and at lower frequencies, when the formula for classical rectification, involving derivatives of the I–V curve, may be used. The rectified low-frequency direct current is well-predicted in this work's model, but not by fitting the experimentally measured I–V curve with a polynomial or by using the older Simmons model (as shown herein). By fitting the measured I–V curves with our model, the barrier heights in Nb-(NbO{sub x}(native)-Nb{sub 2}O{sub 5})-Pt and Ni-NiO-Ti/Ag diodes are found to be 0.41/0.77 and 0.38/0.39 eV, respectively, similar to literature reports, but with effective mass much lower than the free space value. The NbO{sub x} (native)-Nb{sub 2}O{sub 5} dielectric properties improve, and the effective Pt-Nb{sub 2}O{sub 5} barrier height increases as the oxide thickness increases. An observation of direct current of ∼4 nA for normally incident, focused 514 nm continuous wave laser beams are reported, similar in magnitude to recent reports. This measured direct current is compared to the prediction for rectified direct current, given by the rectification responsivity, calculated from the I–V curve times input power.

42 ENGINEERING↗

Simulations of emission from microcavity tandem organic light-emitting diodes

Microcavity tandem organic light-emitting diodes (OLEDs) are simulated and compared to experimental results. The simulations are based on two complementary techniques: rigorous finite element solutions of Maxwell's equations and Fourier space scattering matrix solutions. A narrowing and blue shift of the emission spectrum relative to the noncavity single unit OLED is obtained both theoretically and experimentally. In the simulations, a distribution of emitting sources is placed near the interface of the electron transport layer tris(8-hydroxyquinoline) Al (Alq{sub 3}) and the hole transport layer (N,N'-bis(naphthalen-1-yl)-N,N'-bis(phenyl)benzidine) ({alpha}-NPB). Far-field electric field intensities are simulated. The simulated widths of the emission peaks also agree with the experimental results. The simulations of the 2-unit tandem OLEDs shifted the emission to shorter wavelength, in agreement with experimental measurements. The emission spectra's dependence on individual layer thicknesses also agreed well with measurements. Approaches to simulate and improve the light emission intensity from these OLEDs, in particular for white OLEDs, are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system

The purpose of this work is to evaluate the modeling of carbon fiber couch attenuation properties with a commercial treatment planning system (TPS, Pinnacle{sup 3}, v8.0d). A carbon fiber couch (BrainLab) was incorporated into the TPS by automatic contouring of all transverse CT slices. The couch shape and dimensions were set according to the vendor specifications. The couch composition was realized by assigning appropriate densities to the delineated contours. The couch modeling by the TPS was validated by absolute dosimetric measurements. A phantom consisting of several solid water slabs was CT scanned, the CT data set was imported into the TPS, and the carbon fiber couch was auto-contoured. Open (unblocked) field plans for different gantry angles and field sizes were generated. The doses to a point at 3 cm depth, placed at the linac isocenter, were computed. The phantom was irradiated according to the dose calculation setup and doses were measured with an ion chamber. In addition, percent depth dose (PDD) curves were computed as well as measured with radiographic film. The calculated and measured doses, transmissions, and PDDs were cross-compared. Doses for several posterior fields (0 deg., 30 deg., 50 deg., 75 deg., 83 deg.) were calculated for 6 and 18 MV photon beams. For model validation a nominal field size of 10x10 cm{sup 2} was chosen and 100 MU were delivered for each portal. The largest difference between computed and measured doses for those posterior fields was within 1.7%. A comparison between computed and measured transmissions for the aforementioned fields was performed and the results were found to agree within 1.1%. The differences between computed and measured doses for different field sizes, ranging from 5x5 cm{sup 2} to 25x25 cm{sup 2} in 5 cm increments, were within 2%. Measured and computed PDD curves with and without the couch agree from the surface up to 30 cm depth. The PDDs indicate a surface dose increase resulting from the carbon fiber couch field modification. The carbon fiber couch attenuation for individual posterior oblique fields (75 deg.) can be in excess of 8% depending on the beam energy and field size. When the couch is contoured in Pinnacle{sup 3} its attenuation properties are modeled to within 1.7% with respect to measurements. These results demonstrate that appropriate contouring together with relevant density information for the contours is sufficient for adequate modeling of carbon fiber supporting devices by modern commercial treatment planning systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator

The characteristics of an Elekta amorphous silicon (a-Si) electronic portal imaging device (EPID) in response to a 6 MV photon beam generated without a flattening filter, an unflattened beam, have been determined. The characteristics were then compared to those for a conventional photon beam generated with a flattening filter in the beam, a flattened beam, in order to determine the suitability of an a-Si EPID for transit dosimetry. The response of the EPID to the unflattened beam increased by 7.3% compared to the flattened beam, and copper buildup of 3 mm reduces the variation in the EPID response over air gaps ranging from 60 to 40 cm to within 2.5%. The scattering properties of the EPID with changing field size for the unflattened beam agree with those measured for a flattened beam to within 2%. Due to the minimal variation in the energy spectrum of the unflattened beam with the distance from the central axis, it was expected and experimentally found that the profile shape of the unflattened beam changes minimally with increasing phantom thickness. For an unflattened beam, EPID measured profiles with and without a phantom in the beam agree to within 2% using confidence limits. The difference between EPID and ionization chamber profiles measured at a depth of 5 cm in water is reduced compared to a flattened beam and remains unchanged with increasing phantom thickness. A difference of 4% was found between EPID profiles and the corresponding profiles measured with an ionization chamber measured in water over a range of phantom thickness. A calibration procedure was developed to convert EPID images to the equivalent absolute dose in water, at the EPID plane. A gamma evaluation was performed comparing the calibrated EPID images to dose measured with an ionization chamber array for rectangular fields and an IMRT segment. The fields were situated on axis and at 5 cm off axis with and without a 25 cm thick phantom in the beam. The gamma evaluation criteria of 3% and 3 mm were met within the field, for all fields examined. This study concludes that a-Si EPIDs are suitable dosimeters for IMRT treatments using unflattened photon beams with the advantage that the characteristics of the unflattened beam result in a reduction in the number of measurements necessary to calibrate an a-Si EPID as a transit dosimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry

The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k{sub pl} for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials in the range of 4-18 MV photon beams. For electron beams, a depth-scaling factor c{sub pl} and a chamber-dependent fluence correction factor h{sub pl} for both phantoms were also calculated in combination with NACP-02 and Roos plane-parallel ionization chambers in the range of 4-18 MeV. The h{sub pl} values for the plane-parallel chambers were evaluated from the electron fluence correction factor {phi}{sub pl}{sup w} and wall correction factors P{sub wall,w} and P{sub wall,pl} for a combination of water or plastic materials. The calculated k{sub pl} and h{sub pl} values were verified by comparison with the measured values. A set of k{sub pl} values computed for the Farmer-type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The k{sub pl} values also agreed within their combined uncertainty with the measured data. For electron beams, the c{sub pl} values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4-18 MeV. The {phi}{sub pl}{sup w} values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4-18 MeV. The difference in P{sub wall} between water and plastic materials for the plane-parallel chambers was 0.8% at a maximum. Finally, h{sub pl} values evaluated for plastic materials were equal to unity within 0.6% for NACP-02 and Roos chambers. The h{sub pl} values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo model for a prototype CT-compatible, anatomically adaptive, shielded intracavitary brachytherapy applicator for the treatment of cervical cancer

Purpose: Current, clinically applicable intracavitary brachytherapy applicators that utilize shielded ovoids contain a pair of tungsten-alloy shields which serve to reduce dose delivered to the rectum and bladder during source afterloading. After applicator insertion, these fixed shields are not necessarily positioned to provide optimal shielding of these critical structures due to variations in patient anatomies. The authors present a dosimetric evaluation of a novel prototype intracavitary brachytherapy ovoid [anatomically adaptive applicator (A{sup 3})], featuring a single shield whose position can be adjusted with two degrees of freedom: Rotation about and translation along the long axis of the ovoid. Methods: The dosimetry of the device for a HDR {sup 192}Ir was characterized using radiochromic film measurements for various shield orientations. A MCNPX Monte Carlo model was developed of the prototype ovoid and integrated with a previously validated model of a v2 mHDR {sup 192}Ir source (Nucletron Co.). The model was validated for three distinct shield orientations using film measurements. Results: For the most complex case, 91% of the absolute simulated and measured dose points agreed within 2% or 2 mm and 96% agreed within 10% or 2 mm. Conclusions: Validation of the Monte Carlo model facilitates future investigations into any dosimetric advantages the use of the A{sup 3} may have over the current state of art with respect to optimization and customization of dose delivery as a function of patient anatomical geometries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of out-of-field absorbed dose and equivalent dose in proton fields

Purpose: In proton therapy, as in other forms of radiation therapy, scattered and secondary particles produce undesired dose outside the target volume that may increase the risk of radiation-induced secondary cancer and interact with electronic devices in the treatment room. The authors implement a Monte Carlo model of this dose deposited outside passively scattered fields and compare it to measurements, determine the out-of-field equivalent dose, and estimate the change in the dose if the same target volumes were treated with an active beam scanning technique. Methods: Measurements are done with a thimble ionization chamber and the Wellhofer MatriXX detector inside a Lucite phantom with field configurations based on the treatment of prostate cancer and medulloblastoma. The authors use a GEANT4 Monte Carlo simulation, demonstrated to agree well with measurements inside the primary field, to simulate fields delivered in the measurements. The partial contributions to the dose are separated in the simulation by particle type and origin. Results: The agreement between experiment and simulation in the out-of-field absorbed dose is within 30% at 10-20 cm from the field edge and 90% of the data agrees within 2 standard deviations. In passive scattering, the neutron contribution to the total dose dominates in the region downstream of the Bragg peak (65%-80% due to internally produced neutrons) and inside the phantom at distances more than 10-15 cm from the field edge. The equivalent doses using 10 for the neutron weighting factor at the entrance to the phantom and at 20 cm from the field edge are 2.2 and 2.6 mSv/Gy for the prostate cancer and cranial medulloblastoma fields, respectively. The equivalent dose at 15-20 cm from the field edge decreases with depth in passive scattering and increases with depth in active scanning. Therefore, active scanning has smaller out-of-field equivalent dose by factors of 30-45 in the entrance region and this factor decreases with depth. Conclusions: The dose deposited immediately downstream of the primary field, in these cases, is dominated by internally produced neutrons; therefore, scattered and scanned fields may have similar risk of second cancer in this region. The authors confirm that there is a reduction in the out-of-field dose in active scanning but the effect decreases with depth. GEANT4 is suitable for simulating the dose deposited outside the primary field. The agreement with measurements is comparable to or better than the agreement reported for other implementations of Monte Carlo models. Depending on the position, the absorbed dose outside the primary field is dominated by contributions from primary protons that may or may not have scattered in the brass collimating devices. This is noteworthy as the quality factor of the low LET protons is well known and the relative dose risk in this region can thus be assessed accurately.

61 RADIATION PROTECTION AND DOSIMETRY↗

The water equivalence of solid phantoms for low energy photon beams

Purpose: To compare and evaluate the dosimetric water equivalence of several commonly used solid phantoms for low energy photon beams. Methods: A total of ten different solid phantom materials was used in the study. The PENELOPE Monte Carlo code was used to calculate depth doses and beam profiles in all the phantom materials as well as the dose to a small water voxel at the surface of the solid phantom. These doses were compared to the corresponding doses calculated in a water phantom. The primary photon beams used ranged in energy from 50 to 280 kVp. Results: A number of phantom materials had excellent agreement in dose compared to water for all the x-ray beam energies studied. RMI457 Solid Water, Virtual Water, PAGAT, A150, and Plastic Water DT all had depth doses that agreed with those in water to within 2%. For these same phantom materials, the dose changes in the water voxel at the surface of the solid phantom were within 2%, except for A150, which agreed to within 2.7%. By comparison, the largest differences in depth doses occurred for Plastic Water (-21.7%) and polystyrene (17.6%) for the 50 kVp energy photon beam and 8 cm diameter field size. Plastic Water gave the largest difference in the normalized beam profiles with differences of up to 3.5% as compared to water. Surface dose changes, due to the presence of the solid phantom acting as the backscatter material, were found to be up to 9.1% for polystyrene with significant differences also found for Plastic Water, PMMA, and RW3 phantoms. Conclusions: The following solid phantoms can be considered water equivalent and are recommended for relative dosimetry of low energy photon beams: A150, PAGAT, Plastic Water DT, RMI457 Solid Water, and Virtual Water. However, the following solid phantoms give significant differences, compared to water, in depth doses, profiles, and/or in surface doses due to backscatter changes: Plastic Water, PMMA, polystyrene, PRESAGE, and RW3.

60 APPLIED LIFE SCIENCES↗

4D dose-position verification in radiation therapy using the RADPOS system in a deformable lung phantom

Purpose: A novel 4D in vivo dosimetry system (RADPOS), in conjunction with a deformable lung phantom, has been evaluated as a potential quality assurance tool for 4D radiotherapy. Methods: RADPOS detectors, which consist of a MOSFET dosimeter combined with an electromagnetic positioning probe, were placed inside the deformable lung phantom. One detector was positioned directly inside a tumor embedded in the lung phantom and another was positioned inside the lung portion of the phantom, outside the tumor. CT scans were taken with the phantom at three breathing phases, and for each phase, the detector position inside the phantom was read with the RADPOS software and compared to the position as determined from the CT data. These values were also compared to RADPOS measurements taken with the phantom on the couch of a Varian Clinac 6EX linac. The deformable phantom and the RADPOS system were also used in two radiation delivery scenarios: (1) A simulation of a free-breathing delivery and (2) a simulation of an adaptive treatment. Results: Compared to CT imaging, the RADPOS positional accuracy was found to be better than 2.5 mm. The radial displacement measurements taken in the CT and linac rooms agreed to within an average of (0.7{+-}0.3) mm. Hence, the system can provide relative displacement measurements in the treatment room, consistent with measurements made in the CT room. For the free-breathing delivery, the total dose reported by RADPOS agreed to within 4% and 5% of the treatment planning doses in the tumor and the lung portion of the phantom, respectively. The RADPOS-measured dose values for the adaptive delivery were within 1.5% of the treatment plan values, which was well within the estimated experimental uncertainties. Conclusions: This work has shown that the deformable lung phantom-RADPOS system can be an efficient quality assurance tool for 4D radiation therapy.

60 APPLIED LIFE SCIENCES↗