Studies of Beam Formation and Rest Gas Attenuation in Atomic Beam Sources

At the SpinLab test stand (University of Ferrara), the elastic scattering cross section for molecular hydrogen has been determined for relative velocities in the range 1500-3000 m/s from the measured attenuation of a beam traversing a chamber of rest gas. This cross section is a fundamental input for simulations of gas flows in an atomic beam source with the Direct Simulation Monte Carlo method. Both the predicted beam intensity and width of the beam's velocity distribution are sensitive to the cross section value, and agreement with the measured values is demonstrated for the first time. The simulations also predict properties of the expansion that are difficult to access experimentally, namely a peaking factor of 1.45{+-}0.05 that is essentially independent of input flow in the range 25-250 sccm, and an increase in the beam divergence at the skimmer exit for higher input flows.

43 PARTICLE ACCELERATORS↗

Spin-Filtering studies at COSY and AD

An overview on the present understanding of the methods to polarize an antiproton beam is given and the planned measurements on spin filtering at COSY and AD rings with protons and antiprotons are described. The experimental setup which is being prepared for these measurements is described and focus is given on the polarized internal target.

43 PARTICLE ACCELERATORS↗

Storage Ring Section for a Polarized Gas Target with High Angular Acceptance

In the framework of the FAIR project, the PAX collaboration has suggested new experiments using polarized protons and antiprotons. In order to provide polarized antiprotons, the polarization buildup by spin-dependent attenuation due to nuclear interaction (spin-filtering) must be studied. The goal of these investigations is to understand the physics of the spin-filtering process with stored protons at COSY, and to shed light on the role of polarized electrons for the polarization buildup. Later on, the spin-dependence of the proton-antiproton interaction will be investigated at the Antiproton Decelerator ring (AD) of CERN. In order to carry out these investigations, a storage ring section has to be developed which minimizes the spin-independent losses due to single Coulomb scattering.

43 PARTICLE ACCELERATORS↗

EIC Electron Beam Polarimetry Workshop Summary

A summary of the Precision Electron Beam Polarimetry Workshop for a future Electron Ion Collider (EIC) is presented. The workshop was hosted by the University of Michigan Physics Department in Ann Arbor on August 23-24, 2007 with the goal to explore and study the electron beam polarimetry issues associated with the EIC to achieve sub-1% precision in polarization determination. Ideas are being presented that were exchanged among experts in electron polarimetry and source and accelerator design to examine existing and novel electron beam polarization measurement schemes.

43 PARTICLE ACCELERATORS↗

Plasma Lens for a US Based Super Neutrino Beam

The plasma lens concept is examined as an alternative to focusing horns and solenoids for a neutrino beam facility. The concept is based on a combined high-current lens/target configuration. Current is fed at an electrode located downstream from the beginning of the target where pion capturing is needed. The current is carried by plasma outside the target. A second plasma lens section, with an additional current feed, follows the target. The plasma is immersed in a solenoidal magnetic field to facilitate its current profile shaping to optimize pion capture. Simulations of the not yet fully optimized configuration yielded a 25% higher neutrino flux at a detector situated at 3 km from the target than the horn system for the entire enegry spectrum and a factor of 2.47 higher flux for neutrinos with energy larger than 3 GeV. A major advantage of plasma lenses is in background reduction. In anti-neutrino operation, neutrino background is reduced by a factor of close to 3 for the whole spectrum, and for and for energy larger than 3 GeV; neutrino background is reduced by a factor of 3.6. Plasma lens advantages are due to: larger axial currents, high signal purity: minimal neutrino background in anti-neutrino runs. Additionally the lens medium consists of plasma, consequently, particle absorption and scattering is negligible. Withstanding high mechanical and thermal stresses in a plasma is not an issue.

43 PARTICLE ACCELERATORS↗

T2K Horn

Magnetic horns for T2K experiment have been developed for these several years. Performances of the horns were tested with prototype version of 1st and 3rd horns. 320 kA operation was succeeded with the prototypes. Endurance tests for the horns revealed some problems, most of which were already resolved. Support modules for horn support were also produced. Schemes to allow remote connection and disconnection of horns were developed.

43 PARTICLE ACCELERATORS↗

Laser Propulsion - Is it another myth or a real potential?

This paper discusses different principles of inducing propulsive power using lasers and examines the performance limits along with pros and cons with respect to different space propulsion applications: satellite launching, orbital transfer, space debris clearing, satellite propulsion, and space travels. It concludes that a use of electrical propulsion, in conjunction with laser power beaming, is the most feasible application with technological and economic advantages for commercial use within the next decades.

43 PARTICLE ACCELERATORS↗

Effects of filament geometry on the arc efficiency of a high-intensity He{sup +} ion source

A strongly focusing high-intensity He{sup +} ion source equipped with three concave electrodes has been designed and constructed as the beam source for a high-energy He{sup 0} neutral beam probe system to diagnose fusion-produced alpha particles in thermonuclear fusion plasmas. The reduction of heat load onto the concave extraction electrodes is particularly important for a long pulse operation, as the heat load deforms the electrodes and thus the beam focal length. The effects on the arc efficiency (beam current/arc power) of the ion source due to the discharge filament structure (straight-type and L-shape-type filaments), size (filament diameters of 2 and 1.5 mm), number, and the locations have been studied. Choice of the appropriate filament structure improved the arc efficiency by 17%.

43 PARTICLE ACCELERATORS↗

Improved operation of the nonambipolar electron source

Significant improvements have been made to the nonambipolar electron source (NES), a radio frequency (rf) plasma-based electron source that does not rely on electron emission at a cathode surface [B. Longmier, S. Baalrud, and N. Hershkowitz, Rev. Sci. Instrum. 77, 113504 (2006)]. A prototype NES has produced 30 A of continuous electron current, using 2 SCCM (SCCM denotes cubic centimeter per minute at STP) Xe, 1300 W rf power at 13.56 MHz, yielding a 180 times gas utilization factor. A helicon mode transition has also been identified during NES operation with an argon propellant, using 15 SCCM Ar, 1000 W rf, and 100 G magnetic field. This NES technology has the ability to replace hollow cathode electron sources and to enable high power electric propulsion missions, eliminating one of the lifetime restrictions that many ion thrusters have previously been faced with.

43 PARTICLE ACCELERATORS↗

The use and characterization of a backilluminated charge-coupled device in investigations of pulsed x-ray and radiation sources

Examinations of bremsstrahlung and energetic electron beams from a novel laser plasma source motivate and assist characterization of a backthinned, backilluminated direct detection x-ray charge-coupled device (CCD), a topology that is uncommon in hard x-ray work. Behavior toward pseudomonochromatic ({sup 55}Fe) and multichromatic ({sup 241}Am) sources is briefly reviewed under optimized noise conditions. Results collectively establish the previously unknown functional depth structure. Several modes of usage are illustrated in {approx}4-20 keV x-ray laser plasma source investigations, where the significance of the characterization is briefly discussed. The spectral redistribution associated with this CCD topology is unfavorable, yet appropriate analysis ensures that sufficient spectral information remains for quantitative determination of broadband x-ray flux and spectra in essentially single laser shot measurements. The energy dependence of nascent electron cloud radii in silicon is determined using broadband x-rays from the laser plasma source, turning the narrow depletion depth to advantage. Finally, the characterization is used to quantify recent x-ray spectral explorations of the water jet laser plasma source operating under aspirator vacuum. These results will have key value for establishment of laboratory based ultrafast extended x-ray absorption fine structure experiments using microbolometric detectors.

43 PARTICLE ACCELERATORS↗

Conceptual design of International Linear Collider damping ring wiggler based on a hybrid technology

A magnetic design of a failure-free damping ring wiggler with 100% duty factor, 55.6 mm gap, and field exceeding 1.6 T is proposed. The insertion device is based on permanent magnets and specially shimmed poles that capable to meet the requirements of the International Linear Collider (ILC) damping rings (including positron one), with field quality and gap comparable to that projected for ILC using superconducting wiggler. Performance improvement of the modified hybrid design is attained due to yoke reduction down to six separated strips and maximized packaging of the midgrade (or high-grade) parallelepiped magnet blocks surrounding the Permendur poles. Economical efficiency is demonstrated on the base of calculated amount of magnetic material. A cryogenic variant of the hybrid design may certainly provide good sustainability to harsh radiation environment and further enhancement of the design efficiency within the state of the art.

43 PARTICLE ACCELERATORS↗

Development of compact size penning ion source for compact neutron generator

For long-life operation, easy to mount and compact in size penning type ion sources are widely used in different fields of research such as neutron generators, material research, and surface etching. One penning type ion source has been developed in our laboratory. Applying high voltage of 2 kV between two oppositely biased electrodes and using permanent magnet of 500 gauss magnetic field along the axis, we had produced the glow discharge in the plasma region. The performance of this source was investigated using nitrogen gas. Deuterium ions were produced and extracted on the basis of chosen electrodes and the angle of extraction. Using a single aperture plasma electrode, the beam was extracted along the axial direction. The geometry of plasma electrode is an important factor for the efficient extraction of the ions from the plasma ion source. The extracted ion current depends upon the shape of the plasma meniscus. A concave shaped plasma meniscus produces converged ion beam. The convergence of extracted ions is related to the extraction electrode angle. The greater the angle, the more the beam converges. We had studied experimentally this effect with a compact size penning ion source. The detailed comparison among the different extraction geometry and different electrode angle are discussed in this paper.

43 PARTICLE ACCELERATORS↗

2E1 Ar{sup 17+} decay and conventional radioactive sources to determine efficiency of semiconductor detectors

Although reliable models may predict the detection efficiency of semiconductor detectors, measurements are needed to check the parameters supplied by the manufacturers, namely, the thicknesses of dead layer, beryllium window, and crystal active area. The efficiency of three silicon detectors has been precisely investigated in their entire photon energy range of detection. In the zero to a few keV range, we developed a new method based on the detection of the 2E1 decay of the metastable Ar{sup 17+} 2s{yields}1s transition. Very good theoretical knowledge of the energetic distribution of the 2E1 decay mode enables precise characterization of the absorbing layers in front of the detectors. In the high-energy range (>10 keV), the detector crystal thickness plays a major role in the detection efficiency and has been determined using a {sup 241}Am source.

43 PARTICLE ACCELERATORS↗

Measurement of the energy distribution of an intense electron beam in an external magnetic field

An energy analyzer device has been developed which utilizes a series of stacked foils and Rogowski current monitors to the measure time resolved current of an intense electron beam. The energy distribution of the electron beam is unfolded from measured current ratios using computer simulations. This device is particularly useful where electron beams are guided by external magnetic fields which may make other electron energy measurement techniques difficult. This technique was used to determine the energy distribution of a 550 keV, 95 kA electron beam as it propagates in the gas mixture of a high power KrF laser. The resulting energy distributions at various depths in the gas are in agreement with three-dimensional particle-in-cell simulations providing confidence in the measurement technique.

43 PARTICLE ACCELERATORS↗

Characteristics of rf H{sup -} Ion Source by Using FET Power Source

Characteristics of radio frequency(rf) plasma production are investigated using a FET inverter power supply as an rf generator. The matching circuit in the inverter system is simple compared to a conventional 50 Ohm matching system and only an imaginary part of the impedance of rf transmission should be matched by adjusting operating frequency or capacitance of the circuit. An electron density over 10{sup 18} m{sup -3} is produced in argon plasma with 1 kW rf power. Lower densities are obtained in helium and hydrogen plasmas compared to the argon plasma. Effect of axial magnetic field in driver region is examined. Electron density more than 10{sup 18} m{sup -3} is obtained at the hydrogen gas pressure around 1 Pa with the help of the axial magnetic field.

43 PARTICLE ACCELERATORS↗

Advanced photoelectric effect experiment beamline at Elettra: A surface science laboratory coupled with Synchrotron Radiation

We report the main characteristics of the advanced photoelectric effect experiments beamline, operational at Elettra storage ring, featuring a fully independent double branch scheme obtained by the use of chicane undulators and able to keep polarization control in both linear and circular mode. The paper describes the novel technical solutions adopted, namely, (a) the design of a quasiperiodic undulator resulting in optimized suppression of higher harmonics over a large photon energy range (10-100 eV), (b) the thermal stability of optics under high heat load via cryocoolers, and (c) the end station interconnected setup allowing full access to off-beam and on-beam facilities and, at the same time, the integration of users' specialized sample growth chambers or modules.

43 PARTICLE ACCELERATORS↗

A compact electron beam ion source with integrated Wien filter providing mass and charge state separated beams of highly charged ions

A Wien filter was designed for and tested with a room temperature electron beam ion source (EBIS). Xenon charge state spectra up to the charge state Xe{sup 46+} were resolved as well as the isotopes of krypton using apertures of different sizes. The complete setup consisting of an EBIS and a Wien filter has a length of less than 1 m substituting a complete classical beamline setup. The Wien filter is equipped with removable permanent magnets. Hence total beam current measurements are possible via simple removal of the permanent magnets. In dependence on the needs of resolution a weak (0.2 T) or a strong (0.5 T) magnets setup can be used. In this paper the principle of operation and the design of the Wien filter meeting the requirements of an EBIS are briefly discussed. The first ion beam extraction and separation experiments with a Dresden EBIS are presented.

43 PARTICLE ACCELERATORS↗

Cold-target recoil-ion momentum spectroscopy for diagnostics of high harmonics of the extreme-ultraviolet free-electron laser light source at SPring-8

We have developed a cold-target recoil-ion momentum spectroscopy apparatus dedicated to the experiments using the extreme-ultraviolet light pulses at the free-electron laser facility, SPring-8 Compact SASE Source test accelerator, in Japan and used it to measure spatial distributions of fundamental, second, and third harmonics at the end station.

43 PARTICLE ACCELERATORS↗