Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SU-E-T-110: Development of An Independent, Monte Carlo, Dose Calculation, Quality Assurance Tool for Clinical Trials

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Purpose: To commission a multiple-source Monte Carlo model of Elekta linear accelerator beams of nominal energies 6MV and 10MV. Methods: A three source, Monte Carlo model of Elekta 6 and 10MV therapeutic x-ray beams was developed. Energy spectra of two photon sources corresponding to primary photons created in the target and scattered photons originating in the linear accelerator head were determined by an optimization process that fit the relative fluence of 0.25 MeV energy bins to the product of Fatigue-Life and Fermi functions to match calculated percent depth dose (PDD) data with that measured in a water tank for a 10x10cm2 field. Off-axis effects were modeled by a 3rd degree polynomial used to describe the off-axis half-value layer as a function of off-axis angle and fitting the off-axis fluence to a piecewise linear function to match calculated dose profiles with measured dose profiles for a 40×40cm2 field. The model was validated by comparing calculated PDDs and dose profiles for field sizes ranging from 3×3cm2 to 30×30cm2 to those obtained from measurements. A benchmarking study compared calculated data to measurements for IMRT plans delivered to anthropomorphic phantoms. Results: Along the central axis of the beam 99.6% and 99.7% of all data passed the 2%/2mm gamma criterion for 6 and 10MV models, respectively. Dose profiles at depths of dmax, through 25cm agreed with measured data for 99.4% and 99.6% of data tested for 6 and 10MV models, respectively. A comparison of calculated dose to film measurement in a head and neck phantom showed an average of 85.3% and 90.5% of pixels passing a 3%/2mm gamma criterion for 6 and 10MV models respectively. Conclusion: A Monte Carlo multiple-source model for Elekta 6 and 10MV therapeutic x-ray beams has been developed as a quality assurance tool for clinical trials.

60 APPLIED LIFE SCIENCES↗

OPERATION OF THE CEBAF 100 MV CRYOMODULES

The Continuous Electron Beam Accelerator Facility (CEBAF) 12 GeV upgrade reached its design energy in December of 2015. Since then CEBAF has been deliver-ing 12 GeV beam to experimental Hall D and 11 GeV to experimental halls A and B in support of Nuclear physics. To meet this energy goal, ten new 100 MV cryomodules (80 cavities) and RF systems were installed in 2013. The superconducting RF cavities are designed to operate CW at a maximum accelerating gradient of 19.3 MV/m. To support the higher gradients and higher QL (~ 3×107) op-erations, the RF system uses 13 kW klystrons and digital LLRF to power and control each cavity. This paper re-ports on the C100 operation and optimization improve-ments of the RF system and cryomodules.

Hovater, James↗

Application of electron beam technology to decompose persistent emerging drinking water contaminants: poly- and perfluoroalkyl substances (PFAS) and 1,4 dioxane.

Fermi Research Alliance, LLC (FRA) operates Fermilab under contract with the U.S. Department of Energy and has patents on technologies and applications of a novel mobile electron beam accelerator. A high-power version of this mobile accelerator based on FRA-developed SRF technology is under development at Illinois Accelerator Research Center (IARC) and can enable several new applications that have significant commercial potential. One such application is the e-beam treatment of persistent emerging contaminants in drinking water. The contaminants of concern are poly- and perfluoroalklyl substances (PFAS) and 1,4-dioxine. Both PFAS and 1,4-D are highly resistant to degradation and are not effectively removed by conventional drinking water treatment systems. Existing technologies, such as granular activated carbon (GAC) filters and reverse osmosis (RO) systems do not decompose. The Center for Clean Water Technology (CCWT) at Stony Brook University (SBU) is in the process of identifying and testing effective technologies to remove PFAS and/or 1,4-D from drinking waters. se PFAS, but rather concentrate them either by adsorption (GAC) or membrane rejection (RO). The Center for Clean Water Technology (CCWT) at Stony Brook University (SBU) is in the process of identifying and testing effective technologies to remove PFAS and/or 1,4-D from drinking waters to demonstrate the full-scale application of novel water treatment technologies and is experienced in conducting research to understand treatment performance with a particular focus on 1,4-D and PFAS contamination.

43 PARTICLE ACCELERATORS↗

Particle acceleration at planetary bow shock waves

One property of the collisionless shocks that may be studied through a comparison of their behavior in a variety of plasma conditions at several different planets is the occurrence of MHD waves, associated with particle beams accelerated at these shocks and flowing backward to the sun. Mercury, Venus, earth and Jupiter observations of one of these wave classes show that (1) the empirical relationship between interplanetary field strength and wave frequency in the observer's rest frame is approximately true at all the planets considered, and (2) the observed frequencies are consistent with resonance with beams of ions of the same energy at each of the planets. This is, in turn, in keeping with the Sonnerup (1969) geometrical model of ion reflection at collisionless shocks. It is suggested that this ion acceleration mechanism may occur in astrophysical systems similar to the solar system, providing a source of acceleration for cosmic rays.

Hoppe, M. M.↗

New methods for high current fast ion beam production by laser-driven acceleration

An overview of the last experimental campaigns on laser-driven ion acceleration performed at the PALS facility in Prague is given. Both the 2 TW, sub-nanosecond iodine laser system and the 20 TW, femtosecond Ti:sapphire laser, recently installed at PALS, are used along our experiments performed in the intensity range 10{sup 16}-10{sup 19} W/cm{sup 2}. The main goal of our studies was to generate high energy, high current ion streams at relatively low laser intensities. The discussed experimental investigations show promising results in terms of maximum ion energy and current density, which make the laser-accelerated ion beams a candidate for new-generation ion sources to be employed in medicine, nuclear physics, matter physics, and industry.

43 PARTICLE ACCELERATORS↗

The PEPPo method for polarized positrons and PEPPo II

The Polarized Electrons for Polarized Positrons (PEPPo) experiment at the injector of the Continuous Electron Beam Accelerator Facility demonstrated for the first time the efficient transfer of polarization from electrons to positrons via a two-step process: polarized bremsstrahlung radiation is induced by a polarized electron beam in a high-Z target; then the polarized bremsstrahlung produces polarized positrons via the pair-production process in the same target. Positron polarization up to 82% was measured for an initial electron beam momentum of 8.19 MeV/c, limited only by the electron beam polarization of 85%. This technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community. We present the results of the PEPPo experiment and outline tentative plans for a follow-up experiment that would investigate key aspects of an approach based on PEPPo as a polarized positron source for the 12 GeV Upgrade of CEBAF.

43 PARTICLE ACCELERATORS↗

Self-generated surface magnetic fields inhibit laser-driven sheath acceleration of high-energy protons

High-intensity lasers interacting with solid foils produce copious numbers of relativistic electrons, which in turn create strong sheath electric fields around the target. The proton beams accelerated in such fields have remarkable properties, enabling ultrafast radiography of plasma phenomena or isochoric heating of dense materials. In view of longer-term multidisciplinary purposes (e.g., spallation neutron sources or cancer therapy), the current challenge is to achieve proton energies well in excess of 100 MeV, which is commonly thought to be possible by raising the on-target laser intensity. Here we present experimental and numerical results demonstrating that magnetostatic fields self-generated on the target surface may pose a fundamental limit to sheath-driven ion acceleration for high enough laser intensities. Those fields can be strong enough (~10 5 T at laser intensities ~10 21 W cm –2 ) to magnetize the sheath electrons and deflect protons off the accelerating region, hence degrading the maximum energy the latter can acquire.

43 PARTICLE ACCELERATORS↗

Operation of Lanzhou all permanent electron cyclotron resonance ion source No. 2 on 320 kV platform with highly charged ions

The 320 kV platform for multi-discipline research with highly charged ions is a heavy ion beam acceleration instrument developed by Institute of Modern Physics, which is dedicated to basic scientific researches such as plasma, atom, material physics, and astrophysics, etc. The platform has delivered ion beams of 400 species for 36 000 h. The average operation time is around 5000 h/year. With the beams provided by the platform, lots of outstanding progresses were made in various research fields. The ion source of the platform is an all-permanent magnet electron cyclotron resonance ion source, LAPECR2 (Lanzhou All Permanent ECR ion source No. 2). The maximum axial magnetic fields are 1.28 T at injection and 1.07 T at extraction, and the radial magnetic field is up to 1.21 T at the inner wall of the plasma chamber. The ion source is capable to produce low, medium, and high charge state gaseous and metallic ion beams, such as H{sup +}, {sup 40}Ar{sup 8+}, {sup 129}Xe{sup 30+}, {sup 209}Bi{sup 33+}, etc. This paper will present the latest result of LAPECR2 and the routine operation status for the high voltage platform.

43 PARTICLE ACCELERATORS↗

First Results of the IOTA Ring Research at Fermilab

The IOTA ring at Fermilab is a unique machine exclusively dedicated to accelerator beam physics R&D. The research conducted at IOTA includes topics such as nonlinear integrable optics, suppression of coherent beam instabilities, optical stochastic cooling and quantum science experiments. In this talk we report on the first results of experiments with implementations of nonlinear integrable beam optics. The first of its kind practical realization of a two-dimensional integrable system in a strongly-focusing storage ring was demonstrated allowing among other things for stable beam circulation near or at the integer resonance. Also presented will be the highlights of the world’s first demonstration of optical stochastic beam cooling and other selected results of IOTA’s broad experimental program.

43 PARTICLE ACCELERATORS↗

First Test Results of the New LANSCE Wire Scanner

The Beam Diagnostics and Instrumentation Team (BDIT) at Los Alamos National Laboratory's LANSCE facility is presently developing a new and improved wire scanner diagnostics system controlled by National Instrument's cRIO platform. This paper describes the current state of development of the control system along with the results gathered from the latest actuator motion performance and accelerator-beam data acquisition tests.

Accelerator Design, Technology, and Operations↗

Proof of Principle (POP) for Using Electron Beam to Destroy Contaminants in Samples from a Test Superfund Site (PAHs, PCBs, Dioxins and Furans)

Fermi Research Alliance, LLC (FRA) operates Fermilab under contract with the U.S. Department of Energy and has patents on technologies and applications of a novel mobile electron beam accelerator. A high-power version of this mobile accelerator based on FRA-developed SRF technology is under development at IARC and can enable several new applications that have significant commercial potential. One such application is the e-beam treatment of contaminated sediment sites. The contaminants of concern are a variety of organic chemicals, including dioxins, furans, polyaromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Anchor QEA is interested in determining if electron beam (e-beam) technology can be used to cost effectively destroy contaminants for three specific remediation projects. The goal of this study is to do proof-of-principle (POP) work to evaluate the cost-effectiveness of e-beam treatment in removal of contaminants of concern. The study will be conducted using the Acce

43 PARTICLE ACCELERATORS↗

Polarization and Centre-of-mass Energy Calibration at FCC-ee

The first stage of the FCC (Future Circular Collider) is a high-luminosity electron-positron collider (FCC-ee) with centre-of-mass energy ranging from 88 to 365 GeV, to study with high precision the Z, W, Higgs and top particles, with samples of $5 \times 10^{12}$ Z bosons, $10^8$ W pairs, $10^6$ Higgs bosons and $10^6$ top quark pairs. A cornerstone of the physics program lays in the precise (ppm) measurements of the W and Z masses and widths, as well as forward-backward asymmetries. To this effect the centre-of-mass energy distribution should be determined with the high precision. This document describes the capacity offered by FCC-ee, starting with transverse polarization of the beams around the Z pole and the W pair threshold. A running scheme based on regular measurements of the beam energy by resonant depolarization of pilot bunches, during physics data taking, is proposed. The design for polarization wigglers, polarimeter and depolarizer is outlined. The $e^\pm$ beam energies will be monitored with a relative precision of $10^{-6}$. The centre-of-mass energy is derived subject to further corrections, related to the beam acceleration, synchrotron radiation and beamstrahlung; these effects are identified and evaluated. Dimuon events $e^+e^- \to \mu^+ \mu^-$, recorded in the detectors, provide with great precision the beam crossing angle, the centre-of-mass energy spread, and the $e^+$ and $e^-$ energy difference. Monitoring methods to minimize absolute error and relative uncertainties are discussed. The impact on the physics measurements is given. A programme of further simulations, design, monitoring and R&D is outlined.

43 PARTICLE ACCELERATORS↗

Explainable and Differentiable Reinforcement Learning for Multi-objective Optimization in Particle Accelerators

Operating particle accelerators involves optimizing multiple goals simultaneously, which can be challenging due to trade-offs among objectives. While evolutionary algorithms like the genetic algorithm (GA) have been used for various Multi-Objective Optimization (MOO) tasks, they are not inherently suited for complex control problems. This talk highlights two variations of Reinforcement Learning (RL) for concurrently optimizing heat load and trip rates at the Continuous Electron Beam Accelerator Facility (CEBAF). The problem involves strict constraints on individual states, actions, and overall energy requirements of the beam. First, this talk highlights how differentiability can be harnessed through a Deep Differentiable Reinforcement Learning (DDRL) approach to address MOO issues within particle accelerators. We examine the DDRL method alongside Model Free Reinforcement Learning (MFRL), GA, and Bayesian Optimization (BO). The performance of these methods is assessed by generating a Pareto-front for two objectives. Our findings indicate that DDRL excels in handling high-dimensional problems more effectively than MFRL, BO, and GA. Next, we will show integration of explainable physics-based constraints into RL algorithms to enhance trans- parency and trust in decision-making processes by enabling users to verify that agents adhere to established physical principles. This surrogate function can be modeled using neural networks or sparse dictionary mod- els. By examining the mathematical form of the learned constraint function, we are able to confirm the agent has learned to use the established physics of each environment provided but the surrogate model. In addi- tion, we find that the introduction of a mathematical functional dictionary based surrogate model enables our reinforcement learning algorithms to reliably converge for difficult high-dimensional accelerator controls environments.

Rajput, Kishansingh [Thomas Jefferson National Acc↗

Jefferson Lab Science: Present and Future

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab comprise a unique facility for experimental nuclear physics. Furthermore, this facility is presently being upgraded, which will enable a new experimental program with substantial discovery potential to address important topics in nuclear, hadronic, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility.

43 PARTICLE ACCELERATORS↗

CEBAF SRF Performance during Initial 12 GeV Commissioning

The Continuous Electron Beam Accelerator Facility (CEBAF) energy upgrade from 6 GeV to 12 GeV includes the installation of eleven new 100 MV cryomodules (88 cavities). The superconducting RF cavities are designed to operate CW at an accelerating gradient of 19.3 MV/m with a Q L of 3×10 7 . Not all the cavities were operated at the minimum gradient of 19.3 MV/m with the beam. Though the initial 12 GeV milestones were achieved during the initial commissioning of CEBAF, there are still some issues to be addressed for long term reliable operation of these modules. This paper reports the operational experiences during the initial commissioning and the path forward to improve the performance of C100 (100 MV) modules.

43 PARTICLE ACCELERATORS↗

Simulations of Positron Capture at Ce+BAF

We present a capture concept for the continuous wave (CW) polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (Ce+BAF). This two-step concept is based on (1) the generation of bremsstrahlung radiation by a longitudinally polarized electron beam 1 mA, 120 MeV, 90% polarization), passing through a tungsten target, and (2) the production of e+e--pairs by these bremsstrahlung photons in the same target. To provide highly-polarized positron beams (>60% polarization) or high-current positron beams (>1 µA) with low polarization for nuclear physics experiments, the positron source requires a flexible capture system with an adjustable energy selection band. The results of beam dynamics simulations and calculations of the power deposited in the positron capture section are presented.

Ushakov, Andriy↗

Simulations of Positron Capture at Ce+BAF

We present a capture concept for the continuous wave (CW) polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (Ce+BAF). This two-step concept is based on (1) the generation of bremsstrahlung radiation by a longitudinally polarized electron beam 1 mA, 120 MeV, 90% polarization), passing through a tungsten target, and (2) the production of e+e--pairs by these bremsstrahlung photons in the same target. To provide highly-polarized positron beams (>60% polarization) or high-current positron beams (>1 µA) with low polarization for nuclear physics experiments, the positron source requires a flexible capture system with an adjustable energy selection band. The results of beam dynamics simulations and calculations of the power deposited in the positron capture section are presented.

Ushakov, Andriy↗