Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Magnetic anisotropy in permalloy antidot square lattice

Here, magnetic anisotropy of Permalloy (Py) antidot square lattice was investigated by torquemetry method using Rotation Magneto-Optic Kerr Effect (ROTMOKE). We find that there exists a field-dependent 4-fold magnetic anisotropy with the easy magnetization axis along the axis of the antidot square lattice. In addition, there also exists an artifact of a uniaxial magnetic anisotropy in ROTMOKE result. We show that both results are due to the period wiggling of the magnetization in space which was confirmed by magnetic imaging using magnetic transmission soft x-ray microscopy (MTXM). Micromagnetic simulation from MuMax3 supports the wiggling structure of the magnetization, as well as reproduces ROTMOKE result. A simplified model was developed based on the periodic wiggling of the magnetization and successfully explored the physical origin of the field-dependent 4-fold anisotropy and the artifact of the uniaxial anisotropy.

36 MATERIALS SCIENCE↗

Systematic and statistical uncertainties of the hilbert-transform based high-precision FID frequency extraction method

Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the $\chi^2$ used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum $\chi^2$-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulation of Borosilicate Glass Dissolution using Molecular Dynamics-Generated Glass Structures

Atomic-scale insights into the dissolution mechanisms of borosilicate glasses are critical to the development of the waste form corrosion models that inform performance assessments of nuclear waste disposal facilities. Monte Carlo (MC) simulations have been instrumental in advancing the state of knowledge of borosilicate glass dissolution; however, all such simulations to date have relied on lattices to represent the amorphous glass structure, thereby potentially introducing artifacts. Therefore, a new approach, referred to as the amorphous MC approach, has been developed whereby glass structures generated from molecular dynamics simulations are used as starting points for MC simulations of glass dissolution. MC simulations of sodium borosilicate glasses that covered a wide compositional range were performed and revealed correlations between dissolution rate and structural features of the glasses. Notably, the lattice MC approach predicted the fraction of tetrahedral boron to have a lesser influence on the dissolution rate than computed with the amorphous MC approach. The lattice MC simulations also overestimated the dissolution rate for a given glass composition. These findings highlight the importance of using truly amorphous structures in MC simulations of glass corrosion.

Kerisit, Sebastien N.↗

Modeling the impact of radiation-enhanced diffusion on implanted ion profiles

We report that ion irradiations are a valuable research tool for exploring radiation effects in materials. However, it is well recognized that the implanted ions can artificially modify the radiation damage evolution, e.g., enhancing amorphization processes at low irradiation temperatures and suppressing void swelling at elevated temperatures. Therefore, the implanted ion region should be avoided for most studies of ion irradiated materials. Due to increased interest in high damage, high temperature ion irradiations studying radiation effects in materials for proposed high dose Generation IV fission and fusion energy applications, it is crucial to quantify the extent of diffusional broadening of the implanted ion profile for a variety of temperatures, irradiation fluxes, and sink strengths. The present study summarizes computational analyses of thermal and depth-dependent radiation enhanced difusion (RED) on diffusion broadening of the implanted ion profiles in Fe and Ni for a variety of irradiation conditions. For a low assumed RED coefficient (10 -20 -10 -19 m 2 /s and 10 -4 and 10 -3 peak dpa/s, respectively) or high flux, broadening of the as-implanted ion profile is very small and a suitable artifact-free midrange region for analysis exists for ion energies above 5-6 MeV at 100 peak dpa. At high RED coefficients (10 -19 -10 -18 m 2 /s and 10 -4 and 10 -3 peak dpa/s, respectively) broadening is much more significant, and no valid region for investigation exists below 6-8 MeV ion energies at any damage level >50 dpa. While increasing flux decreases irradiation time, it also increases the RED coefficient; these effects mostly offset except under recombination-dominant conditions. For typical high dose irradiation studies of void swelling that exceed ~100 displacement per atom (dpa), ion energies > 6-8 MeV must be employed in order to achieve suitable artifact-free midrange irradiation analysis regions, depending on the material system. Lastly, analysis of amorphization/precipitation require even higher energies (>10 MeV).

07 ISOTOPE AND RADIATION SOURCES↗

Mesoscale Modeling of the Effects of Accelerated Burnup on UO2 Microstructural Evolution

Accelerating the nuclear fuel qualification process will rely on some combination of advanced modeling and simulation techniques with accelerated irradiation testing and separate effects experiments to enable the development of new fuel concepts in a shorter time frame. One of the key challenges to successfully leveraging accelerated irradiation tests will be understanding the artifacts that may be introduced with accelerated accumulation of dose and/or burnup. This work presents phase field (MARMOT) simulations of the evolution of representative 2D UO2 microstructures up to 40 MWd/kgU. Simulations were performed under both commercial light water reactor fuel conditions as well as those that would be expected for highly accelerated (~10x) burnup conditions similar to those used in the MiniFuel irradiations in Oak Ridge National Laboratory’s High Flux Isotope Reactor. The phase field model was coupled with a discrete nucleation algorithm to model re- structuring at high burnup. The effect of the different fission rates in both microstructures was investigated at two temperatures: 650?C and 800?C. The lower temperature simulations both showed an onset of restructuring at nearly 60 MWd/kgU. More extensive restructuring was obtained in the MiniFuel microstructure compared with that of the PWR fuel. At 800?C, no restructuring was obtained as a result of the thermally activated diffusion of Xe atoms and U vacancies to fission gas bubbles, which reduces the nucleation driving force. These results highlight the importance of using modeling and simulation tools to inform the environmental conditions during targeted accelerated irradiation tests to extract the most useful fuel performance data.

accelerated fuel qualification, Phase Field, Restr↗

Deposition of metallic gallium on re-crystallized ceramic material during focused ion beam milling

We report a new kind of artifact observed in the preparation of a TEM sample of zirconia by FIB, which consists in the deposition of metallic gallium nano-dots on the TEM sample surface. High resolution TEM images showed a microstructure of fine equiaxed grains of ∼ 5 nm, with some of them possessing two particular characteristics: high contrast and well-defined fast Fourier transform. These grains could not be identified as any phase of zirconia but it was possible to identify them as gallium crystals in the zone axis [110]. Based on HRTEM simulations, the possible orientations between zirconia substrate and deposited gallium are discussed in terms of lattice mismatch and oxygen affinity. - Highlights: • We show a new type of artifact induced during preparation of TEM samples by FIB. • Deposition of Ga occurs due to its high affinity for oxygen. • Materials with small grain size (∼ 5 nm) could promote Ga deposition. • Small grain size permits the elastic accommodation of deposited Ga.

36 MATERIALS SCIENCE↗

Triple ion beam cutting of diamond/Al composites for interface characterization

A novel triple ion beam cutting technique was employed to prepare high-quality surfaces of diamond/Al composites for interfacial characterization, which has been unachievable so far. Near-perfect and artifact-free surfaces were obtained without mechanical pre-polishing. Hence, the as-prepared surfaces are readily available for further study and also, ready to be employed in a focus ion beam system for preferential selection of transmission electron microscopy samples. Dramatically different diamond/Al interface configurations — sub-micrometer Al{sub 2}O{sub 3} particles and clean interfaces were unambiguously revealed. - Highlights: • A new triple ion beam technique was employed to prepare diamond/Al composites. • Near-perfect and artifact-free surfaces were obtained for interface characterization. • Sub-micrometer Al{sub 2}O{sub 3} particles and clean interfaces were unambiguously revealed.

36 MATERIALS SCIENCE↗

Comparison of Computed Tomography Scout Based Reference Point Localization to Conventional Film and Axial Computed Tomography

Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment and does not carry risk of misreads caused by artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

An analysis of the nucleon spectrum from lattice partially-quenched QCD.

The chiral extrapolation of the nucleon mass, M{sub n}, is investigated using data coming from 2-flavour partially-quenched lattice simulations. A large sample of lattice results from the CP-PACS Collaboration is analysed using the leading one-loop corrections, with explicit corrections for finite lattice spacing artifacts. The extrapolation is studied using finite-range regularised chiral perturbation theory. The analysis also provides a quantitative estimate of the leading finite volume corrections. It is found that the discretisation, finite volume and partial quenching effects can all be very well described in this framework, producing an extrapolated value of Mn in agreement with experiment. Furthermore, determinations of the low energy constants of the nucleon mass's chiral expansion are in agreement with previous methods, but with significantly reduced errors. This procedure is also compared with extrapolations based on polynomial forms, where the results are less encouraging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correcting nonlinear drift distortion of scanning probe and scanning transmission electron microscopies from image pairs with orthogonal scan directions

Unwanted motion of the probe with respect to the sample is a ubiquitous problem in scanning probe and scanning transmission electron microscopies, causing both linear and nonlinear artifacts in experimental images. We have designed a procedure to correct these artifacts by using orthogonal scan pairs to align each measurement line-by-line along the slow scan direction, by fitting contrast variation along the lines. We demonstrate the accuracy of our algorithm on both synthetic and experimental data and provide an implementation of our method.

36 MATERIALS SCIENCE↗

Image registration of low signal-to-noise cryo-STEM data

Combining multiple fast image acquisitions to mitigate scan noise and drift artifacts has proven essential for picometer precision, quantitative analysis of atomic resolution scanning transmission electron microscopy (STEM) data. For very low signal-to-noise ratio (SNR) image stacks – frequently required for undistorted imaging at liq- uid nitrogen temperatures – image registration is particularly delicate, and standard approaches may either fail, or produce subtly specious reconstructed lattice images. We present an approach which effectively registers and averages image stacks which are challenging due to their low-SNR and propensity for unit cell misalignments. Registering all possible image pairs in a multi-image stack leads to significant information surplus. In combination with a simple physical picture of stage drift, this enables identi cation of incorrect image registrations, and determination of the optimal image shifts from the complete set of relative shifts. Here, we demonstrate the effectiveness of our approach on experimental, cryogenic STEM datasets, highlighting subtle artifacts endemic to low-SNR lattice images and how they can be avoided. High-SNR average images with information transfer out to 0.72 Å are achieved at 300 kV and with the sample cooled to near liquid nitrogen temperature.

47 OTHER INSTRUMENTATION↗

The effect of scanning jitter on geometric phase analysis in STEM images

Geometric phase analysis (GPA) is a useful method to map strain distribution in atomically resolved scanning/transmission electron microscopy (S/TEM) images. Nevertheless, the inevitable periodic jitter of electron probe in STEM along the scanning direction due to the interference of electric power supply, including grounding, can give rise to major artifacts, as evidenced by the appearance of satellite spots surrounding all main peaks in the power spectrum of the images. Here we reveal the origin of the image artifacts related to the probe jitter by mapping the image distortion component εxx using the GPA algorithm. The effect is verified by introducing a periodic displacement field to a STEM image simulated from a perfect crystal structure, and the calculated εxx maps show very good agreement with the experimental observations. Based on the quantitative analysis of the images distortion, we propose and test a feasible strategy to eliminate the effect of probe jitter from STEM images. Successful examples illustrate that the approach can help improve the accuracy in quantification of STEM images.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Level Set Evaporation Model for Heterogeneous Atom Probe Tip

With the development of local electrode atom probe tomography (LEAP), the materials systems feasible for atomic structure determination has expanded from predominantly metals to include heterogeneous materials with complex structure and compositions. This makes the 3D atomic structure determination possible for most energy materials in battery, fuel cell, semiconductor, and nuclear applications. Atom probe tomography (APT) has been utilized to study multiphase materials with segregation and interface problems. The unique and quantitative information retrieved from APT can provide a foundation for the study of kinetic pathways, nanoscale composition mapping, multilayer interfacial segregation, dislocations and grain boundaries. However, a new challenge surfaces when the materials systems expand into heterogeneous materials: the traditional structure reconstruction introduces false magnification and large artifacts due to the underlying assumption of uniform and isotropic evaporation.

Atom probe, heterogeneous structure, evporation mo↗

High-Resolution Field Emission Scanning Electron Microscopy (FESEM) Imaging of Cellulose Microfibril Organization in Plant Primary Cell Walls

Abstract We have used field emission scanning electron microscopy (FESEM) to study the high-resolution organization of cellulose microfibrils in onion epidermal cell walls. We frequently found that conventional “rule of thumb” conditions for imaging of biological samples did not yield high-resolution images of cellulose organization and often resulted in artifacts or distortions of cell wall structure. Here we detail our method of one-step fixation and dehydration with 100% ethanol, followed by critical point drying, ultrathin iridium (Ir) sputter coating (3 s), and FESEM imaging at a moderate accelerating voltage (10 kV) with an In-lens detector. We compare results obtained with our improved protocol with images obtained with samples processed by conventional aldehyde fixation, graded dehydration, sputter coating with Au, Au/Pd, or carbon, and low-voltage FESEM imaging. The results demonstrated that our protocol is simpler, causes little artifact, and is more suitable for high-resolution imaging of cell wall cellulose microfibrils whereas such imaging is very challenging by conventional methods.

biofuels (including algae and biomass), bio-inspir↗

A Simple Preparation Method for Full-Range Electron Tomography of Nanoparticles and Fine Powders

Abstract Electron tomography has become a valuable and widely used tool for studying the three-dimensional nanostructure of materials and biological specimens. However, the incomplete tilt range provided by conventional sample holders limits the fidelity and quantitative interpretability of tomographic images by leaving a “missing wedge” of unknown information in Fourier space. Imaging over a complete range of angles eliminates missing wedge artifacts and dramatically improves tomogram quality. Full-range tomography is usually accomplished using needle-shaped samples milled from bulk material with focused ion beams, but versatile specimen preparation methods for nanoparticles and other fine powders are lacking. In this work, we present a new preparation technique in which powder specimens are supported on carbon nanofibers that extend beyond the end of a tungsten needle. Using this approach, we produced tomograms of platinum fuel cell catalysts and gold-decorated strontium titanate photocatalyst specimens. Without the missing wedge, these tomograms are free from elongation artifacts, supporting straightforward automatic segmentation and quantitative analysis of key materials properties such as void size and connectivity, and surface area and curvature. This approach may be generalized to other samples that can be dispersed in liquids, such as biological structures, creating new opportunities for high-quality electron tomography across disciplines.

Materials Science↗

Focused Ion Beam Preparation of Low Melting Point Metals: Lessons Learned From Indium

Indium (In) and other low melting point metals are used as interconnects in a variety of hybridized circuits and a full understanding of the metallurgy of these interconnects is important to the reliability and performance of the devices. Here, this paper shows that room temperature focused ion beam (FIB) preparation of cross-sections, using Ga + or Xe + can result in artifacts that obscure the true In microbump structure. The use of modified milling strategies to minimize the increased local sample temperature are shown to produce cross-sections that are representative of the In bump microstructure in some sample configurations. Furthermore, cooling of the sample to cryogenic temperatures is shown to reliably eliminate artifacts in FIB prepared cross-sections of In bumps allowing the true bump microstructure to be observed.

36 MATERIALS SCIENCE↗