Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Antiretroviral therapy for HIV and intrahepatic hepatitis C virus replication

HIV alters host responses to hepatitis C virus (HCV). However, the impact of antiretroviral therapy (ART) on HCV is rarely understood in relevant tissues and never before within individual hepatocytes. HIV and HCV kinetics were studied before and after ART initiation among 19 HIV/HCV co-infected persons. From five persons with the largest decline in plasma HCV RNA, liver tissues collected before and during ART, when plasma HIV RNA was undetectable, were studied. Here we used single-cell laser capture microdissection and quantitative PCR to assess intrahepatic HCV. Immunohistochemistry was performed to characterize intrahepatic immune cell populations. Plasma HCV RNA declined by 0.81 (0.52–1.60) log 10 IU/ml from a median (range) 7.26 (6.05–7.29) log 10 IU/ml and correlated with proportions of HCV-infected hepatocytes (r = 0.89, P = 2 × 10 -5 ), which declined from median (range) of 37% (6–49%) to 23% (0.5–52%) after plasma HIV clearance. Median (range) HCV RNA abundance within cells was unchanged in four of five participants. Liver T-cell abundance unexpectedly decreased, whereas natural killer (NK) and NK T-cell infiltration increased, correlating with changes in proportions of HCV-infected hepatocytes (r = -0.82 and r = -0.73, respectively). Hepatocyte expression of HLA-E, an NK cell restriction marker, correlated with proportions of HCV-infected hepatocytes (r = 0.79). These are the first data to show that ART control of HIV reduces the intrahepatic burden of HCV. Furthermore, our data suggest that HIV affects the pathogenesis of HCV infection by an NK/NK T-cell-mediated mechanism that may involve HLA-E and can be rescued, at least in part, by ART.

60 APPLIED LIFE SCIENCES↗

Design and Testing of the Address in Real-Time Data Driver Card for the Micromegas Detector of the ATLAS New Small Wheel Upgrade

The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data in the Micro-Mesh Gaseous Structure (Micromegas) detector of the ATLAS New Small Wheel (NSW) upgrade. The Address in Real Time (ART) signals are generated by the front-end ASIC, named VMM chip, to indicate the address of the first above-threshold event. A custom ASIC (ART ASIC) is designed to receive the ART signals from the VMM chip and implement the hit-selection. The processed data from the ART ASIC will be transmitted out of the NSW through the GBTx serializer, the unidirectional Versatile Twin Transmitter (VTTx) and fiber optical links. The ART signal is critical for the ATLAS experiment trigger selection thus the performance and stability of the ADDC is very important. To ensure extensive testing of the ADDC, an FPGA Mezzanine Card (FMC) based testing platform and a special designed firmware/software are developed. We find that this test platform works with the commercial Xilinx VC707 FPGA development kit, independent of the other electronics of the NSW it can test all the functions of the ADDC and its long-term stability. This paper will introduce the design, testing procedure and results of the ADDC and the FMC testing platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Human Factors in Streaming Data Analysis: Challenges and Opportunities for Information Visualization: Human Factors in Streaming Data Analysis

State-of-the-art visual analytics models and frameworks mostly assume a static snapshot of the data, while in many cases it is a stream with constant updates and changes. Exploration of streaming data poses unique challenges as machine-level computations and abstractions need to be synchronized with the visual representation of the data and the temporally evolving human insights. In the visual analytics literature, we lack a thorough characterization of streaming data and analysis of the challenges associated with task abstraction, visualization design, and adaptation of the role of human-in-the-loop for exploration of data streams. We aim to fill this gap by conducting a survey of the state-of-the-art in visual analytics of streaming data for systematically describing the contributions and shortcomings of current techniques and analyzing the research gaps that need to be addressed in the future. Our contributions are: i) problem characterization for identifying challenges that are unique to streaming data analysis tasks, ii) a survey and analysis of the state-of-the-art in streaming data visualization research with a focus on the visualization design space for dynamic data and the role of the human-in-the-loop, and iii) reflections on the design-trade-offs for streaming visual analytics techniques and their practical applicability in real-world application scenarios.

streaming data↗

SU-E-J-245: Is Off-Line Adaptive Radiotherapy Sufficient for Head and Neck Cancer with IGRT?

Purpose: Radiation doses delivered to patients with head and neck cancer (HN) may deviate from the planned doses because of variations in patient setup and anatomy. This study was to evaluate whether off-line Adaptive Radiotherapy (ART) is sufficient. Methods: Ten HN patients, who received IMRT under daily imaging guidance using CT-on-rail/KV-CBCT, were randomly selected for this study. For each patient, the daily treatment setup was corrected with translational only directions. Sixty weekly verification CTs were retrospectively analyzed. On these weekly verification CTs, the tumor volumes and OAR contours were manually delineated by a physician. With the treatment iso-center placed on the verification CTs, according to the recorded clinical shifts, the treatment beams from the original IMRT plans were then applied to these CTs to calculate the delivered doses. The electron density of the planning CTs and weekly CTs were overridden to 1 g/cm3. Results: Among 60 fractions, D99 of the CTVs in 4 fractions decreased more than 5% of the planned doses. The maximum dose of the spinal cord exceeded 10% of the planned values in 2 fractions. A close examination indicated that the dose discrepancy in these 6 fractions was due to patient rotations, especially shoulder rotations. After registering these 6 CTs with the planning CT allowing six degree of freedoms, the maximum rotations around 3 axes were > 1.5° for these fractions. With rotation setup errors removed, 4 out of 10 patients still required off-line ART to accommodate anatomical changes. Conclusion: A significant shoulder rotations were observed in 10% fractions, requiring patient re-setup. Off-line ART alone is not sufficient to correct for random variations of patient position, although ART is effective to adapt to patients' gradual anatomic changes. Re-setup or on-line ART may be considered for patients with large deviations detected early by daily IGRT images. The study is supported in part by Siemens Medical Solutions.

60 APPLIED LIFE SCIENCES↗

SU-E-J-74: Dosimetric Advantages of Adaptive Radiotherapy for Head and Neck Cancer Are Confirmed with Weekly CBCT Images

Purpose: Our previous study showed that weekly dose monitoring using cone-beam CT (CBCT) images can guide the timing and need for adaptive re-planning during the treatment of head and neck (HN) cancer. Here we aim to confirm the dosimetric improvement of adaptive radiotherapy (ART) using weekly CBCTs. Methods: We randomly selected seven HN patients treated with ART due to noticeable anatomic changes. Twenty weekly images acquired during the second treatment course were included. These CBCTs were aligned with both the initial and re-planning simulation CTs according to the clinical shifts. Daily doses were re-calculated for both the initial and adaptive plans. Contours of the tumor and organs-at-risk (OARs) were manually delineated by a physician on the re-planning CT and then were transferred to the CBCTs for plan evaluation. Contour modifications were made based on the daily anatomic changes observed on CBCTs. All patients were treated with 70Gy to the primary tumor and 56Gy to the elective lymph nodes. Results: Volumetric changes of the tumor (range — 43.9%∼+15.9%) were observed. The average D99 to the primary tumor was (70.1±2.0)Gy (range 62.2∼72.5Gy) for the adaptive plan and (66.0±5.5)Gy (range 50.9∼70.7Gy) for the initial plan(p<<0.01). The average D99 to the elective neck was (56.3±1.3)Gy (range 52.8∼59.2Gy) for the adaptive plan and (52.4±7.0)Gy (range 37.7∼58.6Gy) for the initial plan(p=0.01). The parotid decreased in volume during the treatment course (range 7.3%∼42.2%). The average D-mean to the spared parotid decreased by 15.3% (p=0.002) for the adaptive plan when compared to the original. With ART, 4 out of 7 patients experienced better sparing of the spinal cord (D-max reduced by 2.5%∼10.2%) and the oral cavity (D-mean reduced by 3.5%∼20.1%). Conclusion: Weekly CBCT dosimetry confirms that ART is an effective method to accommodate on-treatment anatomic changes. In select patients, tumor coverage and OAR sparing may be improved with ART. Research is funded by Siemens.

60 APPLIED LIFE SCIENCES↗

waveSZ: A Hardware-Algorithm Co-Design of Efficient Lossy Compression for Scientific Data

Error-bounded lossy compression is critical to the success of extreme-scale scientific research because of ever-increasing volumes of data produced by today's high-performance computing (HPC) applications. Not only can error-controlled lossy compressors significantly reduce the I/O and storage burden but they can retain high data fidelity for post analysis. Existing state-of-the-art lossy compressors, however, generally suffer from relatively low compression and decompression throughput (up to hundreds of megabytes per second on a single CPU core), which considerably restrict the adoption of lossy compression by many HPC applications especially those with a fairly high data production rate. In this paper, we propose a highly efficient lossy compression approach based on field programmable gate arrays (FPGAs) under the state-of-the-art lossy compression model SZ. Our contributions are fourfold. (1) We adopt a wavefront memory layout to alleviate the data dependency during the prediction for higher-dimensional predictors, such as the Lorenzo predictor. (2) We propose a co-design framework named WAVESZ based on the wavefront memory layout and the characteristics of SZ algorithm and carefully implement it by using high-level synthesis. (3) We propose a hardware-algorithm co-optimization method to improve the performance. (4) We evaluate our proposed WAVESZ on three real-world HPC simulation datasets from the Scientific Data Reduction Benchmarks and compare it with other state-of-the-art methods on both CPUs and FPGAs. Experiments show that our WAVESZ can improve SZ's compression throughput by 6.9x similar to 8.7x over the production version running on a state-of-the-art CPU and improve the compression ratio and throughput by 2.1x and 5.8x on average, respectively, respectively, compared with the state-of-the-art FPGA design.

Compression Ratio↗

End-User Evaluation of SHARP for Analysis of Sodium-Cooled Fast Reactors

The DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program is developing the SHARP toolkit to support growing reactor analysis needs in other programs. Although SHARP includes physics modules—especially the computational fluid dynamics code Nek5000 and the structural mechanics tools in Diablo—that have an existing user-base in other fields, most of the analysis and validation efforts for nuclear reactor applications have been performed by members of SHARP’s own development team. The SHARP development team includes engineers and computational scientists from a diverse set of backgrounds, including nuclear engineering. However, before the SHARP tools can be adopted by the Advanced Reactor Technology (ART) program to support the analysis of sodium-cooled fast reactors (SFRs), it would be beneficial for an outside set of analysts and engineers to begin using SHARP and providing feedback to both programs. The authors of this report were charged with learning to use SHARP, applying SHARP to SFR analyses of interest to ART, evaluating the tools, and providing a set of recommendations and requirements to guide future development efforts by the NEAMS program. The authors are engineers (nuclear, mechanical, and civil) by training; all have experience in modeling and simulation for nuclear energy applications; all have either supported ART directly or report to a supervisor who does. This report is a formal summary of the findings of this team of engineers—the potential end-users of SHARP for ART activities. In an informal way, this effort also opened up communication lines between the SHARP developers and ART engineers, which will continue beyond the scope of this effort.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Interim Report

The Graphite Technology Development Program is running a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. The fourth experiment, Advanced Graphite Creep 4 (AGC 4), began with Advanced Test Reactor (ATR) cycle 157D on May 30, 2015, and has been irradiated for two cycles. The capsule was removed from the reactor after ATR cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation will resume when the interfering experiment is removed from the reactor. This report documents qualification of AGC 4 experiment irradiation monitoring data for use by the Advanced Reactor Technologies (ART) Technology Development Office (TDO) Program for research and development activities required to design and license the first HTR nuclear plant. Qualified data meet the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements, but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. All temperature data are Qualified for use by the ART TDO Program. Argon, helium, and total gas flow data were within expected ranges and are Qualified for use by the ART TDO Program. Discharge gas line moisture values were consistently low during cycle 157D. At the start of cycle 158A, gas moisture briefly spiked to over 600 ppmv and then declined throughout the cycle. Moisture values are within the measurement range of the instrument and are Qualified for use by the ART TDO Program. Graphite creep specimens were subjected to one of three loads, 393, 491, or 589 lbf. For a brief period during cycle 157D between 12:19 on June 2, 2015 and 08:23 on June 11, 2015 the load cells were wired incorrectly resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use, but must be taken into account when analyzing the effect of load on creep. Stack displacement increased consistently throughout the first two cycles with total displacement ranging from 0.4 to 0.8 in. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed twice. All stacks were raised successfully each time. The load and displacement data are Qualified for use by the ART TDO Program.

36 MATERIALS SCIENCE↗

HIV-1 transmitted drug resistance surveillance: shifting trends in study design and prevalence estimates

HIV-1 transmitted drug resistance (TDR) prevalence increased during the initial years of the antiretroviral therapy (ART) global scale-up. Few studies have examined recent trends in TDR prevalence using published genetic sequences and described the characteristics of ART-naïve persons from whom these published sequences have been obtained. We identified 125 studies published between 2014 and 2019 for which HIV-1 reverse transcriptase (RT) with or without protease from ≥50 ART-naïve adult persons were submitted to the GenBank sequence database. The population characteristics and TDR prevalence were compared to those in 122 studies published in the preceding five years between 2009 and 2013. TDR prevalence was analysed using median study-level and person-level data. The 2009 to 2013 and 2014 to 2019 studies reported sequence data from 32,866 and 41,724 ART-naïve persons respectively. Studies from the low- and middle-income country (LMIC) regions in sub-Saharan Africa, South/Southeast Asia and Latin America/Caribbean accounted for approximately two-thirds of the studies during each period. Between the two periods, the proportion of studies from sub-Saharan Africa and from South/Southeast Asia countries other than China decreased from 43% to 32% and the proportion of studies performed at sentinel sites for recent HIV-1 infection decreased from 33% to 22%. Between 2014 and 2019, median study-level TDR prevalence was 4.1% in South/Southeast Asia, 6.0% in sub-Saharan Africa, 9.1% in Latin America/Caribbean, 8.5% in Europe and 14.2% in North America. In the person-level analysis, there was an increase in overall, NNRTI and two-class NRTI/NNRTI resistance in sub-Saharan Africa; an increase in NNRTI resistance in Latin America/Caribbean, and an increase in overall, NNRTI and PI resistance in North America. Overall, NNRTI and dual NRTI/NNRTI-associated TDR prevalence was significantly higher in sub-Saharan Africa studies published between 2014 and 2019 compared with those published between 2009 and 2013. The decreasing proportion of studies from the hardest hit LMIC regions and the shift away from sentinel sites for recent infection suggests that global TDR surveillance efforts and publication of findings require renewed emphasis.

60 APPLIED LIFE SCIENCES↗

Provable Repair of Vision Transformers

Vision Transformers have emerged as state-of-the-art image recognition tools, but may still exhibit incorrect behavior. Incorrect image recognition can have disastrous consequences in safety-critical real-world applications such as self-driving automobiles. In this paper, we present Provable Repair of Vision Transformers (PRoViT), a provable repair approach that guarantees the correct classification of images in a repair set for a given Vision Transformer without modifying its architecture. PRoViT avoids negatively affecting correctly classified images (drawdown) by minimizing the changes made to the Vision Transformer’s parameters and original output. Here, we observe that for Vision Transformers, unlike for other architectures such as ResNet or VGG, editing just the parameters in the last layer achieves correctness guarantees and very low drawdown. We introduce a novel method for editing these last-layer parameters that enables PRoViT to efficiently repair state-of-the-art Vision Transformers for thousands of images, far exceeding the capabilities of prior provable repair approaches.

97 MATHEMATICS AND COMPUTING↗

Dose Escalation for Prostate Cancer Using the Three-Dimensional Conformal Dynamic Arc Technique: Analysis of 542 Consecutive Patients

Purpose: To present the results of dose escalation using three-dimensional conformal dynamic arc radiotherapy (3D-ART) for prostate cancer. Methods and Materials: Five hundred and forty two T1-T3N0M0 prostate cancer patients were treated with 3D-ART. Dose escalation (from 76 Gy/38 fractions to 80 Gy/40 fractions) was introduced in September 2003; 32% of patients received 80 Gy. In 366 patients, androgen deprivation was added to 3D-ART. Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria and Houston definition (nadir + 2) were used for toxicity and biochemical failure evaluation, respectively. Median follow-up was 25 months. Results: Acute toxicity included rectal (G1-2 28.9%; G3 0.5%) and urinary events (G1-2 57.9%; G3-4 2.4%). Late toxicity included rectal (G1-2 15.8%; G3-4 3.1%) and urinary events (G1-2 26.9%; G3-4 1.6%). Two-year failure-free survival and overall survival rates were 94.1% and 97.9%, respectively. Poor prognostic group (GS, iPSA, T), transurethral prostate resection, and dose >76 Gy showed significant association to high risk of progression in multivariate analysis (p = 0.014, p = 0.045, and p 0.04, respectively). The negative effect of dose >76 Gy was not observed (p 0.10), when the analysis was limited to 353 patients treated after September 2003 (when dose escalation was introduced). Higher dose was not associated with higher late toxicity. Conclusions: Three-dimensional-ART is a feasible modality allowing for dose escalation (no increase in toxicity has been observed with higher doses). However, the dose increase from 76 to 80 Gy was not associated with better tumor outcome. Further investigation is warranted for better understanding of the dose effect for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sooner or Later? Outcome Analysis of 431 Prostate Cancer Patients Treated With Postoperative or Salvage Radiotherapy

Purpose: To evaluate the outcome of postoperative radiotherapy (PORT) and salvage RT (SART) using a three-dimensional conformal two-dynamic arc (3D-ART) or 3D six-field technique in 431 prostate cancer patients. Methods and Materials: Of the 431 patients, 258 underwent PORT (started <6 months after radical prostatectomy) and 173 underwent SART because of biochemical failure after radical prostatectomy. The median patient age, preoperative prostate-specific antigen level, and Gleason score was 66 years, 9.4 ng/mL, and 7, respectively. The median radiation dose was 70 Gy in 35 fractions for both PORT and SART. The 3D six-field and 3D-ART techniques were used in 25.1% and 74.9% of patients, respectively. Biochemical failure was defined as a post-RT prostate-specific antigen nadir plus 0.1 ng/mL. Results: Acute toxicity included rectal events (PORT, 44.2% and 0.8% Grade 1-2 and Grade 3, respectively; SART, 42.2% and 1.2% Grade 1-2 and Grade 3, respectively) and urinary events (PORT, 51.2% and 2.3% Grade 1-2 and Grade 3-4, respectively; SART, 37.6% and 0% Grade 1-2 and Grade 3, respectively). Late toxicity also included rectal events (PORT, 14.7% and 0.8% Grade 1-2 and Grade 3-4, respectively; SART, 15.0% and 0.6% Grade 1-2 and Grade 3, respectively) and urinary events (PORT, 28.3% and 3.7% Grade 1-2 and Grade 3-4, respectively; SART, 19.3% and 0.6% Grade 1-2 and Grade 3, respectively). After a median follow-up of 48 months, failure-free survival, including biochemical and clinical failure, was significantly longer in the PORT patients (79.8% vs. 60.5%, p < 0.0001). Multivariate analysis showed that a prostate-specific antigen level postoperatively but before RT of {>=}0.2 ng/mL (p < 0.001), Gleason score >6 (p = 0.025) and use of preoperative androgen deprivation (p = 0.002) correlated significantly with shorter failure-free survival. Multivariate analysis showed that PORT and the 3D-ART technique correlated with greater late urinary toxicity. Conclusion: PORT and early referral for SART offer better disease control after radical prostatectomy. The greater urinary toxicity occurring after PORT and 3D-ART requires further investigation to improve the therapeutic index.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Prostate Bed Motion Using Daily Cone-Beam Computed Tomography During Postprostatectomy Radiotherapy

Purpose: To report on the interfraction total positioning error of the postoperative prostate bed and to quantify its components (bony misalignment [BM]and prostate bed motion [PBM]) using daily kilovoltage cone-beam computed tomography (CBCT). The role of an adaptive radiotherapy schedule (ART) was investigated. Methods and Materials: A total of 547 daily CBCT images from 15 consecutive patients who had been treated with prostate bed radiotherapy were retrospectively analyzed. The positioning error was measured by rigid co-registration of the daily CBCT with pretreatment CT planning scan. The total positioning error was quantified by co-registration of the CBCT with the CT planning scan to match the anterior rectal wall. Automatic bony pelvis co-registration was performed to separate BM and PBM. The ART was determined by the average total positioning error from the first 5 CBCT images. Results: The systematic error for the total positioning error in the left-right, superoinferior, and anteroposterior direction was 2.69, 2.00, and 2.65 mm with a random error of 1.99, 1.49, and 2.25 mm, resulting in a planning target volume margin of 8, 6, and 8 mm, respectively. ART reduced the margin by 54%, 44%, and 40%, respectively. Systematic errors in the left-right, superoinferior, and anteroposterior direction for BM was 2.66, 1.83, and 2.60 mm and for PBM was 0.44, 0.92, and 2.50 mm with a random error of 1.88, 1.24, and 1.77 mm for BM and 0.99, 1.38, and 2.32 mm for PBM, respectively. Conclusion: Without treatment verifications, 6-8-mm planning target volume margins are required because of PBM and BM. The anteroposterior PBM was significant. An ART protocol can reduce these planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Evaluation of Incorporating Patient Geometric Variations Into Adaptive Plan Optimization Through Probabilistic Treatment Planning in Head and Neck Cancers

Four-dimensional (4D) adaptive radiation therapy (ART) treatment planning is an alternative to the conventional margin-based treatment planning approach. In 4D ART, interfraction patient geometric variations, gathered from computed tomography (CT) or cone beam CT (CBCT) images acquired during the patient treatment course, are directly incorporated into the adaptive plan optimization using a probabilistic treatment planning method. The goal of the present planning study was to evaluate the dosimetric differences between 4D ART and conventional margin-based adaptive planning strategies for head and neck cancers. In addition, we examined whether the dose differences achieved with 4D ART would translate into clinically relevant toxicity reductions using the existing normal tissue complication probability (NTCP) models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual blockade of IL-10 and PD-1 leads to control of SIV viral rebound following analytical treatment interruption

Human immunodeficiency virus (HIV) persistence during antiretroviral therapy (ART) is associated with heightened plasma interleukin-10 (IL-10) levels and PD-1 expression. We hypothesized that IL-10 and PD-1 blockade would lead to control of viral rebound following analytical treatment interruption (ATI). Twenty-eight ART-treated, simian immunodeficiency virus (SIV)mac 239 -infected rhesus macaques (RMs) were treated with anti-IL-10, anti-IL-10 plus anti-PD-1 (combo) or vehicle. ART was interrupted 12 weeks after introduction of immunotherapy. Durable control of viral rebound was observed in nine out of ten combo-treated RMs for >24 weeks post-ATI. Induction of inflammatory cytokines, proliferation of effector CD8 + T cells in lymph nodes and reduced expression of BCL-2 in CD4 + T cells pre-ATI predicted control of viral rebound. Twenty-four weeks post-ATI, lower viral load was associated with higher frequencies of memory T cells expressing TCF-1 and of SIV-specific CD4 + and CD8 + T cells in blood and lymph nodes of combo-treated RMs. These results map a path to achieve long-lasting control of HIV and/or SIV following discontinuation of ART.

60 APPLIED LIFE SCIENCES↗

Reduced defect density at the CZTSSe/CdS interface by atomic layer deposition of Al{sub 2}O{sub 3}

The greatest challenge for improving the power conversion efficiency of Cu{sub 2}ZnSn(S,Se){sub 4} (CZTSSe)/CdS/ZnO thin film solar cells is increasing the open circuit voltage (V{sub OC}). Probable leading causes of the V{sub OC} deficit in state-of-the-art CZTSSe devices have been identified as bulk recombination, band tails, and the intertwined effects of CZTSSe/CdS band offset, interface defects, and interface recombination. In this work, we demonstrate the modification of the CZTSSe absorber/CdS buffer interface following the deposition of 1 nm-thick Al{sub 2}O{sub 3} layers by atomic layer deposition (ALD) near room temperature. Capacitance-voltage profiling and quantum efficiency measurements reveal that ALD-Al{sub 2}O{sub 3} interface modification reduces the density of acceptor-like states at the heterojunction resulting in reduced interface recombination and wider depletion width. Indications of increased V{sub OC} resulting from the modification of the heterojunction interface as a result of ALD-Al{sub 2}O{sub 3} treatment are presented. These results, while not conclusive for application to state-of-the-art high efficiency CZTSSe devices, suggest the need for further studies as it is probable that interface recombination contributes to reduced V{sub OC} even in such devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

artdaq : DAQ software development made simple

For a few years now, the artdaq data acquisition software toolkit has provided numerous experiments with ready-to-use components which allow for rapid development and deployment of DAQ systems. Developed within the Fermilab Scientific Computing Division, artdaq provides data transfer, event building, run control, and event analysis functionality. This latter feature includes built-in support for the art event analysis framework, allowing experiments to run art modules for real-time filtering, compression, disk writing and online monitoring; as art, also developed at Fermilab, is also used for online analysis, a major advantage of artdaq is that it allows developers to easily switch between developing online and online software. artdaq continues to be improved. Support for an alternate mode of running whereby data from some subdetector components are only streamed if requested has been added; this option will reduce unnecessary DAQ throughput. Real-time reporting of DAQ metrics has been implemented, along with the flexibility to choose the format through which experiments receive the reports; these formats include the Ganglia, Graphite and syslog software packages, along with at ASCII files. Additionally, work has been performed investigating more flexible modes of online monitoring, including the capability of being able to run multiple online monitoring processes on different hosts, each running its own set of art modules. Finally, a web-based GUI interface through which users can configure details of their DAQ system has been implemented, increasing the ease of use of the system. Already successfully deployed on the LArIAT, DarkSide-50, DUNE 35ton and Mu2e experiments, artdaq will be employed for SBND and is a strong candidate for use on ICARUS and protoDUNE. With each experiment comes new ideas for how artdaq can be made more flexible and powerful; the above improvements will be described, along with potential ideas for the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Survey of Tools for Risk Assessment of Cascading Outages

Cascading failure can cause large blackouts, and a variety of methods are emerging to study this challenging topic. In parts 1 and 2 of this paper, the IEEE task force on cascading failure seeks to consolidate and review the progress of the field towards methods and tools of assessing the risk of cascading failure. Part 2 summarizes and discusses the state of the art in the available cascading failure modeling tools. The discussion integrates industry and research perspectives from a variety of institutions. Strengths, weaknesses, and gaps in current approaches are indicated.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗