Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Interfraction and Intrafraction Changes in Amplitude of Breathing Motion in Stereotactic Liver Radiotherapy

Purpose: Interfraction and intrafraction changes in amplitude of liver motion were assessed in patients with liver cancer treated with kV cone beam computed tomography (CBCT)-guided stereotactic body radiation therapy (SBRT). Methods and Materials: A total of 314 CBCTs obtained with the patient in the treatment position immediately before and after each fraction, and 29 planning 4DCTs were evaluated in 29 patients undergoing six-fraction SBRT for unresectable liver cancer, with (n = 15) and without (n = 14) abdominal compression. Offline, the CBCTs were sorted into 10 bins, based on phase of respiration. Liver motion amplitude was measured using liver-to-liver alignment from the end-exhale and end-inhale CBCT and four-dimensional CT reconstructions. Inter- and intrafraction amplitude changes were measured from the difference between the pre-SBRT CBCTs relative to the planning four-dimensional CT, and from the pre-SBRT and post-SBRT CBCTs, respectively. Results: Mean liver motion amplitude for all patients (range) was 1.8 (0.1-7.0), 8.0 (0.1-18.8), and 4.3 (0.1-12.1) mm in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. Mean absolute inter- and intrafraction liver motion amplitude changes were 1.0 (ML), 1.7 (CC), and 1.6 (AP) mm and 1.3 (ML), 1.6 (CC), and 1.9 (AP) mm, respectively. No significant correlations were found between intrafraction amplitude change and intrafraction time (range, 4:56-25:37min:sec), and between inter- and intrafraction amplitude changes and liver motion amplitude. Intraobserver reproducibility ({sigma}, n = 29 fractions) was 1.3 (ML), 1.4 (CC), and 1.4 (AP) mm. Conclusions: For the majority of liver SBRT patients, the change in liver motion amplitude was minimal over the treatment course and showed no apparent relationships with the magnitude of liver motion and intrafraction time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Planning Target Volume Margins for Intensity-Modulated Radiotherapy of the Prostate Gland: Role of Daily Inter- and Intrafraction Motion

Purpose: To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. Methods and Materials: Fourteen patients who underwent definitive intensity-modulated radiotherapy for prostate cancer formed the basis of this study. Each patient was implanted with three electromagnetic transponders and underwent a course of 39 treatment fractions. Daily localization was based on three-point skin mark alignment followed by transponder detection and patient repositioning. Transponder positioning was verified by volumetric imaging with cone-beam computed tomography of the pelvis. Relative motion between the prostate gland and bony anatomy was quantified by offline analyses of daily cone-beam computed tomography. Intratreatment organ motion was monitored continuously by the Calypso (registered) System for quantification of intrafraction setup error. Results: As expected, setup error (that is, inter- plus intrafraction motion, unless otherwise stated) was largest with skin mark alignment, requiring margins of 7.5 mm, 11.4 mm, and 16.3 mm, in the lateral (LR), longitudinal (SI), and vertical (AP) directions, respectively. Margin requirements accounting for intrafraction motion were smallest for transponder detection localization techniques, requiring margins of 1.4 mm (LR), 2.6 mm (SI), and 2.3 mm (AP). Bony anatomy alignment required 2.1 mm (LR), 9.4 mm (SI), and 10.5 mm (AP), whereas image-guided marker alignment required 2.8 mm (LR), 3.7 mm (SI), and 3.2 mm (AP). No marker migration was observed in the cohort. Conclusion: Clinically feasible, rapid, and reliable tools such as the electromagnetic transponder detection system for pretreatment target localization and, subsequently, intratreatment target location monitoring allow clinicians to reduce irradiated volumes and facilitate safe dose escalation, where appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Measurement of the Displacement of Internal Fiducial Markers During 320-Multislice Computed Tomography Scanning of Thoracic Esophageal Cancer

Purpose: To investigate the three-dimensional movement of internal fiducial markers placed near esophageal cancers using 320-multislice CT. Methods and Materials: This study examined 22 metal markers in the esophageal wall near the primary tumors of 12 patients treated with external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. Results: Motion in the cranial-caudal (CC) direction showed a strong correlation (R{sup 2} > 0.4) with the respiratory curve in most markers (73%). The average absolute amplitude of the marker movement was 1.5 {+-} 1.6 mm, 1.6 {+-} 1.7 mm, and 3.3 {+-} 3.3 mm in the left-right (LR), anterior-posterior (AP), and CC directions, respectively. The average marker displacements in the CC direction between peak exhalation and inhalation for the 22 clips were 1.1 mm (maximum, 5.5 mm), 3.0 mm (14.5 mm), and 5.1 mm (16.3 mm) for the upper, middle, and lower thoracic esophagus, respectively. Conclusions: Motion in primary esophagus tumor was evaluated with 320-multislice CT. According to this study, 4.3 mm CC, 1.5 mm AP, and 2.0 mm LR in the upper, 7.4 mm CC, 3.0 mm AP, and 2.4 mm LR in the middle, and 13.8 mm CC, 6.6 mm AP, and 6.8 mm LR in the lower thoracic esophagus provided coverage of tumor motion in 95% of the cases in our study population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Liver Tumor Motion With and Without Abdominal Compression Using Cine-Magnetic Resonance Imaging

Purpose: Abdominal compression (AC) can be used to reduce respiratory liver motion in patients undergoing liver stereotactic body radiotherapy. The purpose of the present study was to measure the changes in three-dimensional liver tumor motion with and without compression using cine-magnetic resonance imaging. Patients and Methods: A total of 60 patients treated as a part of an institutional research ethics board-approved liver stereotactic body radiotherapy protocol underwent cine T2-weighted magnetic resonance imaging through the tumor centroid in the coronal and sagittal planes. A total of 240 cine-magnetic resonance imaging sequences acquired at one to three images each second for 30-60 s were evaluated using an in-house-developed template matching tool (based on the coefficient correlation) to measure the magnitude of the tumor motion. The average tumor edge displacements were used to determine the magnitude of changes in the caudal-cranial (CC) and anteroposterior (AP) directions, with and without AC. Results: The mean tumor motion without AC of 11.7 mm (range, 4.8-23.3) in the CC direction was reduced to 9.4 mm (range, 1.6-23.4) with AC. The tumor motion was reduced in both directions (CC and AP) in 52% of the patients and in a single direction (CC or AP) in 90% of the patients. The mean decrease in tumor motion with AC was 2.3 and 0.6 mm in the CC and AP direction, respectively. Increased motion occurred in one or more directions in 28% of patients. Clinically significant (>3 mm) decreases were observed in 40% and increases in <2% of patients in the CC direction. Conclusion: AC can significantly reduce three-dimensional liver tumor motion in most patients, although the magnitude of the reduction was smaller than previously reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiotherapy (IGRT) for Prostate Cancer Comparing kV Imaging of Fiducial Markers With Cone Beam Computed Tomography (CBCT)

Purpose: To present our single-institution experience with image-guided radiotherapy comparing fiducial markers and cone-beam computed tomography (CBCT) for daily localization of prostate cancer. Methods and Materials: From April 2007 to October 2008, 36 patients with prostate cancer received intensity-modulated radiotherapy with daily localization by use of implanted fiducials. Orthogonal kilovoltage (kV) portal imaging preceded all 1244 treatments. Cone-beam computed tomography images were also obtained before 286 treatments (23%). Shifts in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) dimensions were made from kV fiducial imaging. Cone-beam computed tomography shifts based on soft tissues were recorded. Shifts were compared by use of Bland-Altman limits of agreement. Mean and standard deviation of absolute differences were also compared. A difference of 5 mm or less was acceptable. Subsets including start date, body mass index, and prostate size were analyzed. Results: Of 286 treatments, 81 (28%) resulted in a greater than 5.0-mm difference in one or more dimensions. Mean differences in the AP, SI, and LR dimensions were 3.4 {+-} 2.6 mm, 3.1 {+-} 2.7 mm, and 1.3 {+-} 1.6 mm, respectively. Most deviations occurred in the posterior (fiducials, 78%; CBCT, 59%), superior (79%, 61%), and left (57%, 63%) directions. Bland-Altman 95% confidence intervals were -4.0 to 9.3 mm for AP, -9.0 to 5.3 mm for SI, and -4.1 to 3.9 mm for LR. The percentages of shift agreements within {+-}5 mm were 72.4% for AP, 72.7% for SI, and 97.2% for LR. Correlation between imaging techniques was not altered by time, body mass index, or prostate size. Conclusions: Cone-beam computed tomography and kV fiducial imaging are similar; however, more than one-fourth of CBCT and kV shifts differed enough to affect target coverage. This was even more pronounced with smaller margins (3 mm). Fiducial imaging requires less daily physician input, is less time-consuming, and is our preferred method for prostate image-guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robustness Against Interfraction Prostate Movement in Scanned Ion Beam Radiation Therapy

Purpose: To assess the robustness of scanned ion beam treatment plans against the interfraction internal target motion and evaluate the limits of validity of target-based isocenter realignment for prostate cancer radiation therapy. Methods and Materials: For 12 prostate patients, scanned beam carbon ion treatment plans were prepared using 2 lateral opposed beams and the raster scanning technique with different clinical target volume (CTV) to planning target volume (PTV) margins (2-10 mm). Internal target motion of 2-15 mm in anteroposterior (AP), superoinferior (SI), and left-to-right (LR) directions was simulated by displacing the CTV contours with respect to the computed tomography data. The plans were recalculated with and without target-based isocenter realignment and the CTV coverage was assessed. Results: For CTV shifts within the applied planning margin, the CI-98% is greater than 98.0%, both with and without isocenter realignment. Without realignment, because of the sharp lateral gradients, the CI-98% shows rapid fall as soon as the target shift exceeds the applied planning margin for all displacement directions. With isocenter realignment, the coverage improves notably for shifts in AP and SI directions and the CI-98% is restored to >95.0% for plans optimized with a 2-mm margin, >97% with a 3-mm margin, and >98% with larger margins. For large corrections, predominately in AP direction, cold spots in the CTV may occur. Their magnitude is dependent on the patients' individual anatomies. Conclusions: Within the physiological limits of internal prostate movement, target-based isocenter realignment results in improved CTV coverage for shifts in AP and SI directions exceeding the applied planning margin. Assuming optimal patient setup reproducibility (eg, immobilization, setup error correction, patient preparation protocols), hence negligible interfraction bone and soft-tissue variations, changes in traversed densities resulting from target-based realignment applied with a reduced planning margin do not induce significant dose deterioration in most of the cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Non-Gaussian Nature of Prostate Motion Based on Real-Time Intrafraction Tracking

Purpose: The objective of this work is to test the validity of the Gaussian approximation for prostate motion through characterization of its spatial distribution. Methods and Materials: Real-time intrafraction prostate motion was observed using Calypso 4-dimensional (4D) nonradioactive electromagnetic tracking system. We report the results from a total of 1024 fractions from 31 prostate cancer patients. First, the correlation of prostate motion in right/left (RL), anteroposterior (AP), and superoinferior (SI) direction were determined using Pearson's correlation of coefficient. Then the spatial distribution of prostate motion was analyzed for individual fraction, individual patient including all fractions, and all patients including all fractions. The displacement in RL, AP, SI, oblique, or total direction is fitted into a Gaussian distribution, and a Lilliefors test was used to evaluate the validity of the hypothesis that the displacement is normally distributed. Results: There is high correlation in AP/SI direction (61% of fractions with medium or strong correlation). This is consistent with the longitudinal oblique motion of the prostate, and likely the effect from respiration on an organ confined within the genitourinary diaphragm with the rectum sitting posteriorly and bladder sitting superiorly. In all directions, the non-Gaussian distribution is more common for individual fraction, individual patient including all fractions, and all patients including all fractions. The spatial distribution of prostate motion shows an elongated shape in oblique direction, indicating a higher range of motion in the AP and SI directions. Conclusions: Our results showed that the prostate motion is highly correlated in AP and SI direction, indicating an oblique motion preference. In addition, the spatial distribution of prostate motion is elongated in an oblique direction, indicating that the organ motion dosimetric modeling using Gaussian kernel may need to be modified to account for the particular organ motion character of prostate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging

Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions and its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation of carbon and oxygen rich surface layer on high purity magnesium by atmospheric carbon dioxide plasma

Carbon and oxygen-rich corrosion barrier layer formed on Mg by a simple and scalable CO 2 atmospheric plasma (CO 2 -AP) process. The reactive CO 2 -AP interacts with the Mg surface and forms a unique layered structure with the top MgCO 3 /MgO-intermixed particulates pillars and the bottom dense layer. The surface features were simultaneously formed on the nano-/micro-structured MgO layer by carbonate molecules, plasma-active CO 2 molecules, and/or other volatile organic compounds on the nano-/micro-structured MgO particle layer. The resulting surfaces after CO 2 -AP were either hydrophobic or hydrophilic and exhibited lower anodic current or high resistance for Mg corrosion. For the hydrophobic surfaces of CO 2 -AP treated Mg, molecular dynamic simulations were performed to understand the origin of hydrophobicity and identified that the amorphous carbon layers formed on the Mg surface are the source. The environmentally benign abundant-gas-based process enables the cost reduction associated with waste treatment, generation of by-product, and supply of raw material.

36 MATERIALS SCIENCE↗

Improve the catalytic activity of {alpha}-Fe{sub 2}O{sub 3} particles in decomposition of ammonium perchlorate by coating amorphous carbon on their surface

Sphere- and pod-like {alpha}-Fe{sub 2}O{sub 3} particles have been selectively synthesized using NH{sub 3}.H{sub 2}O and NaOH solution to adjust the pH value of the designed synthetic system, respectively. The sphere-like {alpha}-Fe{sub 2}O{sub 3} particles with diameter about 25 nm on average were encapsulated into carbon shells to fabricate a novel core-shell composite ({alpha}-Fe{sub 2}O{sub 3}-C) through the coating experiments. The catalytic performance of the products on the thermal decomposition of ammonium perchlorate (AP) was investigated by thermal gravimetric analyzer (TG) and differential thermal analysis (DTA). The thermal decomposition temperatures of AP in the presence of pod-like {alpha}-Fe{sub 2}O{sub 3}, sphere-like {alpha}-Fe{sub 2}O{sub 3} and {alpha}-Fe{sub 2}O{sub 3}-C are reduced by 72, 81 and 109 {sup o}C, respectively, which show that {alpha}-Fe{sub 2}O{sub 3}-C core-shell composites have higher catalytic activity than that of {alpha}-Fe{sub 2}O{sub 3}. -- Graphical abstract: The catalytic performance of pod-like {alpha}-Fe{sub 2}O{sub 3}, sphere-like {alpha}-Fe{sub 2}O{sub 3} and {alpha}-Fe{sub 2}O{sub 3}-C on the thermal decomposition of ammonium perchlorate (AP). Display Omitted Research highlights: {yields} Sphere- and pod-like {alpha}-Fe{sub 2}O{sub 3} particles have been selectively synthesized using NH{sub 3}.H{sub 2}O and NaOH solution to adjust the pH value. {yields} A novel core-shell composite ({alpha}-Fe{sub 2}O{sub 3}-C core-shell structured composite) has been successfully synthesized using sphere-like {alpha}-Fe{sub 2}O{sub 3} particles as the cores and glucose as the source of carbon. {yields} The thermal decomposition temperatures of AP in the presence of pod-like {alpha}-Fe{sub 2}O{sub 3}, sphere-like {alpha}-Fe{sub 2}O{sub 3} and {alpha}-Fe{sub 2}O{sub 3}-C are reduced by 72, 81 and 109 {sup o}C, respectively, which shows that these materials have high catalytic activity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Co-Al mixed metal oxides/carbon nanotubes nanocomposite prepared via a precursor route and enhanced catalytic property

The present work reported the synthesis of Co-Al mixed metal oxides/carbon nanotubes (CoAl-MMO/CNT) nanocomposite from Co-Al layered double hydroxide/CNTs composite precursor (CoAl-LDH/CNT). The materials were characterized by powder X-ray diffraction (XRD), transmission electron microscopy (TEM), low temperature nitrogen adsorption-desorption experiments, thermogravimetric and differential thermal analyses (TG-DTA), Raman spectra and X-ray photoelectron spectroscopy (XPS). The results revealed that in CoAl-MMO/CNT nanocomposite, the nanoparticles of cobalt oxide (CoO) and Co-containing spinel-type complex metal oxides could be well-dispersed on the surface of CNTs, thus forming the heterostructure of CoAl-MMO and CNTs. Furthermore, as-synthesized CoAl-MMO/CNT nanocomposite was utilized as additives for catalytic thermal decomposition of ammonium perchlorate (AP). Compared to those for pure AP and CoAl-MMO, the peak temperature of AP decomposition for CoAl-MMO/CNT was significantly decreased, which is attributed to the novel heterostructure and synergistic effect of multi-component metal oxides of nanocomposite. - Graphical abstract: Hybrid Co-Al mixed metal oxides/carbon nanotubes nanocomposite showed the enhanced catalytic activity in the thermal decomposition of ammonium perchlorate, as compared to carbon nanotubes and pure Co-Al mixed metal oxides. Highlights: Black-Right-Pointing-Pointer Co-Al mixed metal oxides/carbon nanotubes nanocomposite was synthesized. Black-Right-Pointing-Pointer Co-Al mixed metal oxides consisted of cobalt oxide and Co-containing spinels. Black-Right-Pointing-Pointer Nanocomposite exhibited excellent catalytic activity for the decomposition of AP. Black-Right-Pointing-Pointer The superior catalytic property is related to novel heterostructure and composition.

36 MATERIALS SCIENCE↗

In-situ and self-distributed: A new understanding on catalyzed thermal decomposition process of ammonium perchlorate over Nd{sub 2}O{sub 3}

Catalyzed thermal decomposition process of ammonium perchlorate (AP) over neodymium oxide (Nd{sub 2}O{sub 3}) was investigated. Catalytic performances of nanometer-sized Nd{sub 2}O{sub 3} and micrometer-sized Nd{sub 2}O{sub 3} were evaluated by differential scanning calorimetry (DSC). In contrast to universal concepts, catalysts in different sizes have nearly similar catalytic activities. Based on structural and morphological variation of the catalysts during the reaction, combined with mass spectrum analyses and studies of unmixed style, a new understanding of this catalytic process was proposed. We believed that the newly formed chloride neodymium oxide (NdOCl) was the real catalytic species in the overall thermal decomposition of AP over Nd{sub 2}O{sub 3}. Meanwhile, it was the “self-distributed” procedure which occurred within the reaction that also worked for the improvement of overall catalytic activities. This work is of great value in understanding the roles of micrometer-sized catalysts used in heterogeneous reactions, especially the solid–solid reactions which could generate a large quantity of gaseous species. - Graphical abstract: In-situ and self-distributed reaction process in thermal decomposition of AP catalyzed by Nd{sub 2}O{sub 3}. - Highlights: • Micro- and nano-Nd{sub 2}O{sub 3} for catalytic thermal decomposition of AP. • No essential differences on their catalytic performances. • Structural and morphological variation of catalysts digs out catalytic mechanism. • This catalytic process is “in-situ and self-distributed” one.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using kV-kV and CBCT imaging to evaluate rectal cancer patient position when treated prone on a newly available belly board

The goal of this work was to use daily kV-kV imaging and weekly cone-beam CT (CBCT) to evaluate rectal cancer patient position when treated on a new couch top belly board (BB). Quality assurance (QA) of the imaging system was conducted weekly to ensure proper performance. The positional uncertainty of the combined kV-kV image match and subsequent couch move was found to be no more than {+-} 1.0 mm. The average (1 SD) CBCT QA phantom match was anterior-posterior (AP) = -0.8 {+-} 0.2 mm, superior-inferior (SI) = 0.9 {+-} 0.2 mm, and left-right (LR) = -0.1 {+-} 0.1 mm. For treatment, a set of orthogonal kV-kV images were taken and a bony anatomy match performed online. Moves were made along each axis (AP, SI, and LR) and recorded for analysis. CBCT data were acquired once every 5 fractions for a total of 5 images per patient. The images were all taken after the couch move but before treatment. A 3-dimensional (3D-3D) bony anatomy auto-match was performed offline and the residual difference in position recorded for analysis. The average ({+-} 1 SD) move required from skin marks, calculated over all 375 fractions (15 patients Multiplication-Sign 25 fractions/patient), were AP = -2.6 {+-} 3.7 mm, SI = -0.3 {+-} 4.9 mm, and LR = 1.8 {+-} 4.5 mm. The average residual difference in patient position calculated from the weekly CBCT data (75 total) were AP = -1.7 {+-} 0.4 mm, SI = 1.1 {+-} 0.6 mm, and LR = -0.5 {+-} 0.2 mm. These results show that the BB does provide simple patient positioning that is accurate to within {+-} 2.0 mm when using online orthogonal kV-kV image matching of the pelvic bony anatomy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nicotine stimulates urokinase-type plasminogen activator receptor expression and cell invasiveness through mitogen-activated protein kinase and reactive oxygen species signaling in ECV304 endothelial cells

Urokinase-type plasminogen activator receptor (uPAR) expression is elevated during inflammation, tissue remodeling and in many human cancers. This study investigated the effect of nicotine, a major alkaloid in tobacco, on uPAR expression and cell invasiveness in ECV304 endothelial cells. Nicotine stimulated uPAR expression in a dose-dependent manner and activated extracellular signal-regulated kinases-1/2 (Erk-1/2), c-Jun amino-terminal kinase (JNK) and p38 mitogen activated protein kinase (MAPK). Specific inhibitors of MEK-1 (PD98059) and JNK (SP600125) inhibited the nicotine-induced uPAR expression, while the p38 MAPK inhibitor SB203580 did not. Expression vectors encoding dominant negative MEK-1 (pMCL-K97M) and JNK (TAM67) also prevented nicotine-induced uPAR promoter activity. The intracellular hydrogen peroxide (H{sub 2}O{sub 2}) content was increased by nicotine treatment. The antioxidant N-acetylcysteine prevented nicotine-activated production of reactive oxygen species (ROS) and uPAR expression. Furthermore, exogenous H{sub 2}O{sub 2} increased uPAR mRNA expression. Deleted and site-directed mutagenesis demonstrated the involvement of the binding sites of transcription factor nuclear factor-kappaB (NF-κB) and activator protein (AP)-1 in the nicotine-induced uPAR expression. Studies with expression vectors encoding mutated NF-κB signaling molecules and AP-1 decoy confirmed that NF-κB and AP-1 were essential for the nicotine-stimulated uPAR expression. MAPK (Erk-1/2 and JNK) and ROS functioned as upstream signaling molecules in the activation of AP-1 and NF-κB, respectively. In addition, ECV304 endothelial cells treated with nicotine displayed markedly enhanced invasiveness, which was partially abrogated by uPAR neutralizing antibodies. The data indicate that nicotine induces uPAR expression via the MAPK/AP-1 and ROS/NF-κB signaling pathways and, in turn, stimulates invasiveness in human ECV304 endothelial cells. -- Highlights: ► Endothelial cells treated with nicotine displayed enhanced invasiveness. ► Nicotine induces uPAR expression and, in turn, stimulates invasiveness. ► MAPK/AP-1 and ROS/NF-κB signals are involved in nicotine-induced uPAR.

60 APPLIED LIFE SCIENCES↗

Bisphenol A at a low concentration boosts mouse spermatogonial cell proliferation by inducing the G protein-coupled receptor 30 expression

Bisphenol A (BPA) is one of the most prevalent chemicals in daily-use materials, therefore, human exposure to BPA is ubiquitous. We found that low concentrations of BPA stimulate the spermatogonial GC-1 cells proliferation by G protein-coupled receptor 30 (GPR30)-mediated epidermal growth factor receptor (EGFR)-extracellular regulated kinase (ERK)-c-Fos pathway. However, through the same pathway GPR30 expression has been shown to be induced by EGF, an EGFR ligand. Thus, we want to know if low concentrations of BPA are able to induce the GPR30 expression and the possible mechanism(s) in GC-1 cells. By transient transfection with expression plasmids, 10{sup −9} M BPA significantly transactivates the Gpr30-5′-flanking region through activating the GPR30, cGMP-dependent protein kinase (PKG), estrogen receptor-α (ER-α), and EFGR-ERK pathways. Furthermore, an activator protein-1 (AP-1) site located within this region is found to be responsible for the transactivation of BPA. Expectedly, through the same pathways, BPA significantly induces the gene and protein expression of GPR30. c-Fos is further observed to be strongly recruited to the AP-1 site in a chromatin immunoprecipitation assay and its dysfunction on the AP-1 site markedly suppresses the expression of GPR30, p-ERK1/2, p-Ser118-ER-α and cell proliferation by BPA. Our results demonstrate that a low-concentration BPA induces GPR30 expression through the GPR30-EFGR-ERK-c-Fos, ER-α, and PKG pathways, presumably boosting the cells proliferation via a regulatory loop. The present study provides a novel insight into the potential role of GPR30 in the initiation and progression of male germ cell cancer induced by environmentally relevant BPA. - Highlights: ► Low concentrations of BPA activate the PKG and GPR30-EFGR-ERK-ER-α pathways. ► Low concentrations of BPA activate the AP-1 site of Gpr30-5′-flanking region. ► Low concentrations of BPA induce the expression of GPR30 gene and protein. ► Low concentrations of BPA boost GC-1 cells proliferation via a regulatory loop.

60 APPLIED LIFE SCIENCES↗

Interaction of inflammatory and anti-inflammatory responses in microglia by Staphylococcus aureus-derived lipoteichoic acid

We investigated the interaction between proinflammatory and inflammatory responses caused by Staphylococcus aureus-derived lipoteichoic acid (LTA) in primary cultured microglial cells and BV-2 microglia. LTA induced inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2) protein levels increase in a concentration- and time-dependent manner. Meanwhile, LTA also increased nitric oxide (NO) and PGE{sub 2} production in microglia. Administration of TLR2 antagonist effectively inhibited LTA-induced NO, iNOS, and COX-2 expression. Moreover, treatment of cells with LTA caused a time-dependent activation of ERK, p38, JNK, as well as AKT. We also found that LTA-induced iNOS and COX-2 up-regulation were attenuated by p38, JNK, and PI3-kinase inhibitors. On the other hand, LTA-enhanced HO-1 expression was attenuated by p38 and PI3-kinase inhibitors. Treatment of cells with NF-κB and AP-1 inhibitors antagonized LTA-induced iNOS and COX-2 expression. However, only NF-κB inhibitors reduced LTA-induced HO-1 expression in microglia. Furthermore, stimulation of cells with LTA also activated IκBα phosphorylation, p65 phosphorylation at Ser{sup 536}, and c-Jun phosphorylation. Moreover, LTA-induced increases of κB-DNA and AP-1-DNA binding activity were inhibited by p38, JNK, and PI3-kinase inhibitors. HO-1 activator CoPP IX dramatically reversed LTA-induced iNOS expression. Our results provided mechanisms linking LTA and inflammation/anti-inflammation, and indicated that LTA plays a regulatory role in microglia activation. - Highlights: • LTA causes an increase in iNOS, COX-2, and HO-1 expression in microglia. • LTA induces iNOS and COX-2 expression through TLR-2/NF-κB and AP-1 pathways. • HO-1 expression is regulated through p38, JNK, PI3K/AKT and AP-1 pathways. • Induced HO-1 reduces LTA-induced iNOS expression. • LTA plays a regulatory role on inflammatory/anti-inflammatory responses.

60 APPLIED LIFE SCIENCES↗

Anti-addiction drug ibogaine inhibits voltage-gated ionic currents: A study to assess the drug's cardiac ion channel profile

The plant alkaloid ibogaine has promising anti-addictive properties. Albeit not licenced as a therapeutic drug, and despite hints that ibogaine may perturb the heart rhythm, this alkaloid is used to treat drug addicts. We have recently reported that ibogaine inhibits human ERG (hERG) potassium channels at concentrations similar to the drugs affinity for several of its known brain targets. Thereby the drug may disturb the heart's electrophysiology. Here, to assess the drug's cardiac ion channel profile in more detail, we studied the effects of ibogaine and its congener 18-Methoxycoronaridine (18-MC) on various cardiac voltage-gated ion channels. We confirmed that heterologously expressed hERG currents are reduced by ibogaine in low micromolar concentrations. Moreover, at higher concentrations, the drug also reduced human Na{sub v}1.5 sodium and Ca{sub v}1.2 calcium currents. Ion currents were as well reduced by 18-MC, yet with diminished potency. Unexpectedly, although blocking hERG channels, ibogaine did not prolong the action potential (AP) in guinea pig cardiomyocytes at low micromolar concentrations. Higher concentrations (≥ 10 μM) even shortened the AP. These findings can be explained by the drug's calcium channel inhibition, which counteracts the AP-prolonging effect generated by hERG blockade. Implementation of ibogaine's inhibitory effects on human ion channels in a computer model of a ventricular cardiomyocyte, on the other hand, suggested that ibogaine does prolong the AP in the human heart. We conclude that therapeutic concentrations of ibogaine have the propensity to prolong the QT interval of the electrocardiogram in humans. In some cases this may lead to cardiac arrhythmias. - Highlights: • We study effects of anti-addiction drug ibogaine on ionic currents in cardiomyocytes. • We assess the cardiac ion channel profile of ibogaine. • Ibogaine inhibits hERG potassium, sodium and calcium channels. • Ibogaine’s effects on ion channels are a potential source of cardiac arrhythmias. • 18-Methoxycoronaridine has a lower affinity for cardiac ion channels than ibogaine.

60 APPLIED LIFE SCIENCES↗

Wave propagation speeds and source term influences in single and integral porosity shallow water equations

In urban flood modeling, so-called porosity shallow water equations (PSWEs), which conceptually account for unresolved structures, e.g., buildings, are a promising approach to addressing high CPU times associated with state-of-the-art explicit numerical methods. The PSWE can be formulated with a single porosity term, referred to as the single porosity shallow water model (SP model), which accounts for both the reduced storage in the cell and the reduced conveyance, or with two porosity terms: one accounting for the reduced storage in the cell and another accounting for the reduced conveyance. The latter form is referred to as an integral or anisotropic porosity shallow water model (AP model). The aim of this study was to analyze the differences in wave propagation speeds of the SP model and the AP model and the implications of numerical model results. First, augmented Roe-type solutions were used to assess the influence of the source terms appearing in both models. It is shown that different source terms have different influences on the stability of the models. Second, four computational test cases were presented and the numerical models were compared. It is observed in the eigenvalue-based analysis as well as in the computational test cases that the models converge if the conveyance porosity in the AP model is close to the storage porosity. If the porosity values differ significantly, the AP model yields different wave propagation speeds and numerical fluxes from those of the BP model. In this study, the ratio between the conveyance and storage porosities was determined to be the most significant parameter.

58 GEOSCIENCES↗