Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APERTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Comparison Between Hybrid Direct Aperture Optimized Intensity-Modulated Radiotherapy and Forward Planning Intensity-Modulated Radiotherapy for Whole Breast Irradiation

Purpose: To investigate the planning efficiency and dosimetric characteristics of hybrid direct aperture optimized (hDAO) intensity-modulated radiotherapy (IMRT) compared with forward planning (FP)-IMRT for whole breast irradiation with two tangential beams. Methods and Materials: A total of 15 patients with left-sided breast cancer, categorized with three different breast volumes, were selected for this study. All patients were treated with FP plans to 50 Gy in 25 fractions. The hDAO plans were created by combining two open fields with eight segments in two tangential beam directions and were inversely optimized. Results: The FP and hDAO plans achieved similar breast coverage and sparing of critical organs. The volume of breast receiving 105% of the prescription dose was significantly smaller in the hDAO than in the FP plans: 25% vs. 63% (p = .008) for small, 22% vs. 57% (p = .005) for medium, and 28% vs. 53% (p = .005) for large breasts. Furthermore, the tumor cavity coverage was slightly better in the hDAO plans (92.4% vs. 90.9%). Conclusion: Compared with FP-IMRT, hDAO-IMRT provided dosimetric advantages, significantly reducing the size of the hot spot and slightly improving the coverage of the tumor cavity. In addition, hDAO-IMRT required less planning time and was less dependent on the planner's ability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast dynamic aperture optimization with forward-reversal integration

A fast dynamic aperture (DA) optimization method for storage rings has been developed through the use of reversal integration. Even if dynamical systems have an exact reversal symmetry, a numerical forward integration differs from its reversal. For a chaotic trajectory, cumulative round-off errors are scaled, which results in an exponential growth on the difference. The exponential effect is a generic chaos indicator which represents the sensitivity of the chaotic motion to its initial condition. The chaos indicator of the charged particle motion can be obtained by comparing the forward integrations of particle trajectories with corresponding reversals, a.k.a. “backward integrations.” The indicator is observable even through short-term particle tracking simulations. Therefore, adopting it as an objective function could speed up optimization. Finally, the DA of the National Synchrotron Light Source II storage ring, and another test diffraction-limited light source ring, were optimized using this method for the purpose of demonstration.

43 PARTICLE ACCELERATORS↗

the Large Aperture GRB Observatory

The Large Aperture GRB Observatory (LAGO) aims at the detection of high energy photons from Gamma Ray Bursts (GRB) using the single particle technique (SPT) in ground based water Cherenkov detectors (WCD). To reach a reasonable sensitivity, high altitude mountain sites have been selected in Mexico (Sierra Negra, 4550 m a.s.l.), Bolivia (Chacaltaya, 5300 m a.s.l.) and Venezuela (Merida, 4765 m a.s.l.). We report on the project progresses and the first operation at high altitude, search for bursts in 6 months of preliminary data, as well as search for signal at ground level when satellites report a burst.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of high-current electron beam in a wide-aperture open discharge

In the present study, it was examined generation of nanosecond-duration electron-beam (EB) pulses by a wide-aperture open discharge burning in helium or in a mixture of helium with nitrogen and water vapor. In the experiments, a discharge cell with coaxial electrode geometry, permitting radial injection of the electron beam into operating lasing medium, was used, with the cathode having radius 2.5 cm and length 12 cm. It was shown possible to achieve an efficient generation of a high-intensity electron beam (EB pulse power {approx}250 MW and EB pulse energy up to 4 J) in the kiloampere range of discharge currents (up to 26 kA at {approx}12 kV discharge voltage). The current-voltage characteristics of the discharge proved to be independent of the working-gas pressure. The existence of an unstable dynamic state of EB, conditioned by the presence of an uncompensated space charge accumulated in the discharge cell due to the exponential growth of the current in time during discharge initiation and the hyperbolic growth of current density in the direction towards the tube axis, was revealed. The obtained pulsed electron beam was used to excite the self-terminated laser on He 2{sup 1}P{sub 1}{sup 0}-2{sup 1}S{sub 0} transition. The oscillations developing in the discharge cell at high discharge currents put limit to the pumping energy and emissive power of the laser excited with the radially converging electron beam.

43 PARTICLE ACCELERATORS↗

Radiation thermometer size-of-source effect testing using aperture

Size-of-source effect is an important attribute of any radiation thermometer. The effects of this attribute may be quantified in a number of different ways to include field-of-view, distance ratio, or size-of-source effect. These parameters provide needed information for the user of a radiation thermometer, as they aid in determining whether the measured object is large enough for adequate radiation thermometry measurement. Just as important, these parameters provide needed information for calibration. This information helps to determine calibration geometry, and it is needed for calibration uncertainty determination. For determination of size-of-source effect, there are a limited number of test methods furnished by the standards available today. The test methods available may be cumbersome to perform due to the cost of the required equipment and the time needed to set-up and perform the test. Other methods have been proposed. This paper discusses one such method. This method uses a circular aperture such as that used in radiation thermometer calibration. It describes the method both theoretically and mechanically. It then discusses testing done to verify this method comparing the results to those obtained while performing steps in current standards. Finally, based on this testing, the basis for a new standard test method is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of aperture and beam lifetime using movable beam scrapers in Indus-2 electron storage ring

In this paper, the measurements of vertical and horizontal aperture which are available for stable beam motion in Indus-2 at beam energy 2.5 GeV using movable beam scrapers are presented. These beam scrapers are installed in one of the long straight sections in the ring. With the movement of beam scrapers towards the beam centre, the beam lifetime is measured. The beam lifetime data obtained from the movement of vertical and horizontal beam scrapers are analyzed. The contribution of beam loss due to beam-gas scattering (vacuum lifetime) and electron-electron scattering within a beam bunch (Touschek lifetime) is separated from the measured beam lifetime at different positions of the beam scrapers. Vertical and horizontal beam sizes at scrapers location are estimated from the scraper movement towards the beam centre in quantum lifetime limit and their values closely agree with measured value obtained using X-ray diagnostic beamline.

43 PARTICLE ACCELERATORS↗

Acoustic characterization of high intensity focused ultrasound fields generated from a transmitter with a large aperture

Prediction and measurement of the acoustic field emitted from a high intensity focused ultrasound (HIFU) is essential for the accurate ultrasonic treatment. In this study, the acoustic field generated from a strongly focused HIFU transmitter was characterized by a combined experiment and simulation method. The spheroidal beam equation (SBE) was utilized to describe the nonlinear sound propagation. The curve of the source pressure amplitude versus voltage excitation was determined by fitting the measured ratio of the second harmonic to the fundamental component of the focal waveform to the simulation result; finally, the acoustic pressure field generated by the strongly focused HIFU transmitter was predicted by using the SBE model. A commercial fiber optic probe hydrophone was utilized to measure the acoustic pressure field generated from a 1.1 MHz HIFU transmitter with a large half aperture angle of 30°. The maximum measured peak-to-peak pressure was up to 72 MPa. The validity of this combined approach was confirmed by the comparison between the measured results and the calculated ones. The results indicate that the current approach might be useful to describe the HIFU field. The results also suggest that this method is not valid for low excitations owing to low sensitivity of the second harmonic.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Barrier reduction via implementation of InGaN interlayer in wafer-bonded current aperture vertical electron transistors consisting of InGaAs channel and N-polar GaN drain

This letter reports the influence of the added InGaN interlayer on reducing the inherent interfacial barrier and hence improving the electrical characteristics of wafer-bonded current aperture vertical electron transistors consisting of an InGaAs channel and N-polar GaN drain. The current-voltage characteristics of the transistors show that the implementation of N-polar InGaN interlayer effectively reduces the barrier to electron transport across the wafer-bonded interface most likely due to its polarization induced downward band bending, which increases the electron tunneling probability. Fully functional wafer-bonded transistors with nearly 600 mA/mm of drain current at V{sub GS} = 0 V and L{sub go} = 2 μm have been achieved, and thus demonstrate the feasibility of using wafer-bonded heterostructures for applications that require active carrier transport through both materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The benefits of using time-frequency analysis with synthetic aperture focusing technique

Improvements in detection and resolution are always desired and needed. There are various instruments available for the inspection of concrete structures that can be used with confidence for detecting different defects. However, more often than not that confidence is heavily dependent on the experience of the operator rather than the clear, objective discernibility of the output of the instrument. The challenge of objective discernment is amplified when the concrete structures contain multiple layers of reinforcement, are of significant thickness, or both, such as concrete structures in nuclear power plants. We seek to improve and extend the usefulness of results produced using the synthetic aperture focusing technique (SAFT) on data collected from thick, complex concrete structures. A secondary goal is to improve existing SAFT results, with regards to repeatedly and objectively identifying defects and/or internal structure of concrete structures. Towards these goals, we are applying the time-frequency technique of wavelet packet decomposition and reconstruction using a mother wavelet that possesses the exact reconstruction property. However, instead of analyzing the coefficients of each decomposition node, we select and reconstruct specific nodes based on the frequency band it contains to produce a frequency band specific time-series representation. SAFT is then applied to these frequency specific reconstructions allowing SAFT to be used to visualize the reflectivity of a frequency band and that band's interaction with the contents of the concrete structure. We apply our technique to data sets collected using a commercial, ultrasonic linear array (MIRA) from two 1.5m × 2m × 25cm concrete test specimens. One specimen contains multiple layers of rebar. The other contains honeycomb, crack, and rebar bonding defect analogs. This approach opens up a multitude of possibilities for improved detection, readability, and overall improved objectivity. We will focus on improved defect/reinforcement isolation in thick and multilayered reinforcement environments. Additionally, the ability to empirically explore the possibility of a frequency-band-defect-type relationship or sensitivity becomes available.

36 MATERIALS SCIENCE↗

Remote optical sensing on the nanometer scale with a bowtie aperture nano-antenna on a fiber tip of scanning near-field optical microscopy

Plasmonic nano-antennas have proven the outstanding ability of sensing chemical and physical processes down to the nanometer scale. Sensing is usually achieved within the highly confined optical fields generated resonantly by the nano-antennas, i.e., in contact to the nanostructures. In this paper, we demonstrate the sensing capability of nano-antennas to their larger scale environment, well beyond their plasmonic confinement volume, leading to the concept of “remote” (non contact) sensing on the nanometer scale. On the basis of a bowtie-aperture nano-antenna (BNA) integrated at the apex of a SNOM (Scanning Near-field Optical Microscopy) fiber tip, we introduce an ultra-compact, moveable, and background-free optical nanosensor for the remote sensing of a silicon surface (up to distance of 300 nm). Sensitivity of the BNA to its large scale environment is high enough to expect the monitoring and control of the spacing between the nano-antenna and a silicon surface with sub-nanometer accuracy. This work paves the way towards an alternative class of nanopositioning techniques, based on the monitoring of diffraction-free plasmon resonance, that are alternative to nanomechanical and diffraction-limited optical interference-based devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Large aperture Fizeau interferometer commissioning and preliminary measurements of a long x-ray mirror at European X-ray Free Electron Laser

The European XFEL (X-ray Free Electron Laser) is a large facility under construction in Hamburg, Germany. It will provide a transversally fully coherent x-ray radiation with outstanding characteristics: high repetition rate (up to 2700 pulses with a 0.6 ms long pulse train at 10 Hz), short wavelength (down to 0.05 nm), short pulse (in the femtoseconds scale), and high average brilliance (1.6 ⋅ 10{sup 25} (photons s{sup −1} mm{sup −2} mrad{sup −2})/0.1% bandwidth). The beam has very high pulse energy; therefore, it has to be spread out on a relatively long mirror (about 1 m). Due to the very short wavelength, the mirrors need to have a high quality surface on their entire length, and this is considered very challenging even with the most advanced polishing methods. In order to measure the mirrors and to characterize their interaction with the mechanical mount, we equipped a metrology laboratory with a large aperture Fizeau interferometer. The system is a classical 100 mm diameter commercial Fizeau, with an additional expander providing a 300 mm diameter beam. Despite the commercial nature of the system, special care has been taken in the polishing of the reference flats and in the expander quality. We report the first commissioning of the instrument, its calibration, and performance characterization, together with some preliminary results with the measurement of a 950 mm silicon substrate. The intended application is to characterize the final XFEL mirrors with nanometer accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Repetitively pulsed regime of Nd : glass large-aperture laser amplifiers

A repetitively pulsed operation regime of neodymium glass rod laser amplifiers with apertures of 4.5, 6, 8.5, and 10 cm is analysed using experimental data. The limits of an increase in the pulse repetition rates are determined. Universal dependences are obtained, which help finding a compromise between increasing the repetition rate and enhancing the gain for each particular case. In particular, it is shown that an amplifier 4.5-cm in diameter exhibits a five-fold safety factor with respect to a thermo-mechanical breakdown at a repetition rate of 1 pulse min{sup -1} and stored energy of above 100 J. A strong thermally induced birefringence in two such amplifiers is experimentally reduced to a 'cold' level by employing a 90 Degree-Sign optical rotator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wide-aperture laser diode array in the external V-shaped cavity

The operation of a wide-aperture laser diode array with the radiation wavelength 980 nm in external V-shaped symmetric and asymmetric cavities is experimentally studied. The regimes of stable oscillation are studied as functions of the feedback beam direction. The spectra and the intensity distribution of radiation in the far zone are presented for the laser diode in symmetric and asymmetric cavities. Tuning of the radiation wavelength is demonstrated using the Littman geometry in the asymmetric cavity. (lasers)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Divergence and polarisation of radiation of a wide-aperture chemical DF laser with an unstable resonator

Influence of a plane-parallel plate, placed inside an unstable resonator and entirely overlapping the beam cross section, on the polarisation and divergence of wide-aperture DF-laser radiation is studied at various angles of plate inclination to the resonator axis. It is shown that the plate inside a resonator has no effect on the radiation divergence and only requires a corresponding shift of a convex mirror in order to keep the resonator confocal. A noticeable change in the radiation polarisation has been observed only at angles of plate inclination greater than 20°; at angles of above 45° the radiation becomes actually linearly polarised. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of pumping level on the uniformity of the power and spectrum distributions over the emitting aperture of cw laser diode bars

Thermal parameters of cw laser diode bars (LDBs) have been studied experimentally and using 3D simulation in order to identify factors limiting their output power and operational life. Using a thermal camera, we have obtained thermal field images of 47-cluster LDBs with an aperture fill factor of 50 %, packaged in a heat spreader of the C – S mount type. Distributions of the output power and emission spectrum of the emitting clusters have been measured by a probing method. The simulation results and experimental data have been analysed, compared and discussed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

APERTURE SYNTHESIS OBSERVATIONS OF THE NEARBY SPIRAL NGC 6503: MODELING THE THIN AND THICK H I DISKS

We present sensitive aperture synthesis observations of the nearby, late-type spiral galaxy NGC 6503, and produce H I maps of considerably higher quality than previous observations by van Moorsel and Wells. We find that the velocity field, while remarkably regular, contains clear evidence for irregularities. The H I is distributed over an area much larger than the optical image of the galaxy, with spiral features in the outer parts and localized holes within the H I distribution. The absence of absorption toward the nearby quasar 1748+700 yields an upper limit of 5 x 10{sup 17} cm{sup -2} for the column density of cold H I gas along a line of sight which should intersect the disk at a radius of 29 kpc. This suggests that the radial extent of the H I disk is not much larger than that which we trace in H I emission (23 kpc). The observed H I distribution is inconsistent with models of a single thin or thick disk. Instead, the data require a model containing a thin disk plus a thicker low column-density H I layer that rotates more slowly than the thin disk and that extends only to approximately the optical radius. This suggests that the presence of extraplanar gas in this galaxy is largely the result of star formation in the disk rather than cold gas accretion. Improved techniques for interferometric imaging including multi-scale Clean that were used in this work are also described.

79 ASTRONOMY AND ASTROPHYSICS↗

IMAGING FAINT BROWN DWARF COMPANIONS CLOSE TO BRIGHT STARS WITH A SMALL, WELL-CORRECTED TELESCOPE APERTURE

We have used our 1.6 m diameter off-axis well-corrected subaperture (WCS) on the Palomar Hale telescope in concert with a small inner-working-angle phase-mask coronagraph to image the immediate environs of a small number of nearby stars. Test cases included three stars (HD 130948, HD 49197, and HR7672) with known brown dwarf companions at small separations, all of which were detected. We also present the initial detection of a new object close to the nearby young G0V star HD171488. Follow-up observations are needed to determine if this object is a bona fide companion, but its flux is consistent with the flux of a young brown dwarf or low-mass M star at the same distance as the primary. Interestingly, at small angles our WCS coronagraph demonstrates a limiting detectable contrast comparable to that of extant Lyot coronagraphs on much larger telescopes corrected with current-generation adaptive optics (AO) systems. This suggests that small apertures corrected to extreme AO (ExAO) levels can be used to carry out initial surveys for close brown dwarf and stellar companions, leaving follow-up observations for larger telescopes.

99 GENERAL AND MISCELLANEOUS↗