Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ALTITUDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

SMPS data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow, 1.0 LPM, is directed through TSI's 0.071 cm impactor attached to the classifier of the SMPS setup. The SMPS’s DMA and CPC are connected through a 20.3 cm length of 0.48 cm diameter tubing. Measured SMPS size distributions were used to calculate size-dependent particle losses for each SMPS scan. Particle losses from diffusion (based on Kesten, 1991 and Gormley, 1949) and inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977) were included in the loss calculation. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Mini-Micropulse Lidar data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (mini-MPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. The mini-MPL deployed with ROAM-V is a 532 nm elastic and polarization lidar. The mini-MPL outputs normalized relative backscatter (NRB) derived from raw signal after after-pulse, overlap, and dead-time correction calibration. The depolarization ratio is calculated from the co-polarized and cross-polarized NRB (Flynna et al., 2007). The NRB and depolarization ratio data are resampled from the original data at 1-minute intervals. The vertical resolution of the mini-MPL data is 15 meters. The mini-MPL data can be used to determine the boundary layer, cloud top, and cloud bottom height and can be used to retrieve aerosol type and concentration profile. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu . Flynna, C. J., Mendozaa, A., Zhengb, Y., & Mathurb, S. (2007). Novel polarization-sensitive micropulse lidar measurement technique. Optics express, 15(6), 2785-2790.

54 ENVIRONMENTAL SCIENCES↗

TRACER-Tethersonde VOC data

One objective of TRACER-Tethersonde campaign was to deploy a volatile organic compound (VOC) sampler on the Tethered Balloon System (TBS) to create vertical profiles and characterize VOC composition. Volatile organic compounds (VOCs) are highly reactive precursor species that undergo atmospheric processing to form secondary products, including aerosol. VOC emissions are influenced by many factors that include but are not limited to temperature, time of day, local anthropogenic activities, and local vegetation, which result in large spatiotemporal variability. The vertical distribution of volatile species is crucial for understanding gas-phase processing for particle production but challenging to accomplish using currently available sampling devices. The standalone sampler built during the campaign enabled the execution of robust experimental designs, including sample collection using resin tubes at multiple altitudes on subsequent flights. Following field sampling, resin tubes were transported back to Baylor University for chemical analysis using a Markes International thermal desorption unit coupled with a gas chromatograph-tandem mass spectrometer (Thermo Scientific). The target analyte list includes biogenic and anthropogenic VOCs.

54 ENVIRONMENTAL SCIENCES↗

TRACER-Tethersonde Ozone data

TRACER-Tethersonde, a sub-campaign of TRACER, took place during the TRACER June-September 2022 intensive operating period (IOP) at the S3 Ancillary site (29.33°N, 95.74°W) near Guy, TX. The Tethered Balloon System (TBS) operated during the first two weeks of each month during the TRACER IOP, making multiple (~4) up and down vertical profiles each day that could reach as high as ~1 km. TRACER-Tethersonde included an En-Sci electrochemical cell (ECC) ozonesonde on the TBS. The ozonesonde was connected to an iMet-4RSB radiosonde, and the overall data collected included ozone, relative humidity, temperature, and altitude.

54 ENVIRONMENTAL SCIENCES↗

Leipzig University W-Band Cloud Radar, Gothic (Colorado), SAIL Campaign Second Winter (15.11.2022 - 05.06.2023)

The instrument is a polarimetric W-Band simultaneous transmission simultaneous reception (STSR) Doppler Cloud Radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP). It was deployed about 500m away from the ARM M1 facility in Gothic (CO) near the Ore House between Nov 15, 2022 and Jun 5, 2023 at an altitude of 2913 m. The Doppler cloud radar was mounted on a prototype of a cold temperature scanner manufactured by RPG. The dataset contains common radar variables like equivalent radar reflectivity factor, mean Doppler velocity, Doppler spectrum width as well as common polarimetric radar variables like differential phase shift (PhiDP), specific differential phase shift (KDP), correlation coefficient (RHV) and differential reflectivity (ZDR). Between Nov 15, 2022, and Feb 7, 2023 the radar was operated at 40° constant elevation and 151° azimuth (towards the KAZR at the AMF1). Between Feb 7 and Mar 15, 2023 the following scan cycle was repeated in 15min intervals: zenith pointing measurements, RHI scans from 0° to 90° and 90° to 0° elevation at 151° azimuth, constant elevation measurements at 40° elevation and 151° azimuth and PPI scans at 85° elevation for wind retrievals (one PPI per hour). Between Mar 15 18:18 UTC and Apr 8, 2023 11:04 UTC, the scanner was stuck at 72° elevation, which resulted in corrupted files for this period. For that period, the files containing data are uploaded but should be treated with care. Between Apr 8 and Apr 14, 2023 the scanning pattern described above was performed again. Afterwards, except for May 17 and May 18, 2023 where scanning patterns as described above were performed, measurements continued at 40° elevation and 151° azimuth until May 22, 2023 09:00 UTC. The scanning pattern was then started again, but without hourly PPI measurements until May 31, 2023. Between May 31 and Jun 5, 2023 solely zenith-pointing observations were performed. The data provided here are the RPG Level 1 (L1) files, Doppler spectra Level 0 (L0) files are available upon request.

54 ENVIRONMENTAL SCIENCES↗

minimpl (b1)

The micropulse lidar (MPL) is a ground-based, optical, remote-sensing system designed primarily to determine the altitude of clouds; however, it is also used for detection of atmospheric aerosols. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal, thereby detecting clouds and aerosols in real time. From the time delay between each outgoing pulse and the backscattered signal, the distance to the scatterer is inferred. Post-processing of the lidar return characterizes the extent and properties of aerosols or other particles in a region.

54 ENVIRONMENTAL SCIENCES↗

NPFTURBULENCE: Best Estimate Aerosol Size Distribution by airborne measurements

The original data were collected during the field campaign of “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IT temperature and imagery, aerosol number concentration and size distribution. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 2 sensors: miniaturized Scanning Electrical Mobility Sizer (mSEMS) and Portable Optical Particle Spectrometer (POPS). The mSEMS data were interpolated to 1 second from “native” time resolution of about 15 second to match the other probe. The POPS data were converted from equivalent optical size into geometric size using value of aerosol refractive index of 1.477 from the HISCALE field campaign (same geographical area, altitudes, and time of year; http://www.arm.gov/campaigns/aaf2016hiscale ).

54 ENVIRONMENTAL SCIENCES↗

COURAGE S7 TBS AIRBORNE SONIC WIND AND TURBULENCE DATA

These data were collected with airborne wind instrumentation booms onboard the TBS at CoURAGE S7 during February 2025. The data include 60 Hz wind speed, component wind speed, wind direction, TKE, TI, and altitude measurements.

54 ENVIRONMENTAL SCIENCES↗

BNF M1 TBS AIRBORNE SONIC WIND AND TURBULENCE DATA

These data were collected with airborne wind instrumentation booms onboard the TBS at BNF M1. The data include 60 Hz wind speed, component wind speed, wind direction, TKE, TI, and altitude measurements.

54 ENVIRONMENTAL SCIENCES↗

202508 HAIIC IR Images with Attitude Data at BNF

This campaign aims to collect infrared imagery using a custom data acquisition system to improve and validate a previously developed attitude estimation algorithm, with a focus on ensuring reliable performance at higher altitudes. The system integrates a Boson+320 infrared camera, a VN-200 IMU for recording attitude data synchronized with image acquisition, and a Raspberry Pi 4B+ for onboard processing and storage. Image orientation was controlled using a Gremsy T7 gimbal. The primary dataset spans roll angles from −40° to 40° and pitch angles from −20° to 40°, sampled at 1° increments. Additional, smaller datasets were also collected at 2.5° angular intervals.

Boson+320↗

Wind and Temperature Consensus at Horn Point, HU-Beltsville, Piney Run (Maryland) in support of CoURAGE

The Maryland Department of the Environment (MDE) operates a ground-based atmospheric profiling network consisting of collocated radar wind profilers (RWP) and radio acoustic sounding systems (RASS) as part of its Ambient Air Monitoring Program. This network provides continuous observations of wind and temperature structure in the lower troposphere to support air quality forecasting, regulatory analysis, and atmospheric research. The network currently includes three fixed sites across Maryland: Horn Point (HP, lower eastern shore) [38.587525°,-76.141006°], Howard University-Beltsville (HUB, central Maryland) [39.055277°, -76.878632°], and Piney Run (PR, western Maryland) [39.705950°, -79.012000°] The network is designed to capture regional variability in atmospheric transport and boundary-layer processes. These systems measure vertical profiles of horizontal wind speed and direction using Doppler radar techniques, with observations typically spanning from ~100 m above ground level up to approximately 2.5–4 km. Measurements are derived from the Doppler shift of backscattered electromagnetic signals, enabling retrieval of wind vectors at multiple altitudes with high temporal resolution (e.g., 30-minute averages reported every 6 minutes). Each radar wind profiler is paired with a Radio Acoustic Sounding System (RASS) to provide profiles of virtual temperature in the lower atmosphere (~100–200 m AGL) by measuring the propagation speed of acoustic waves. Together, the RWP/RASS system yields a coupled data set of thermodynamic and kinematic atmospheric structure, including additional parameters such as vertical velocity, radial velocity, signal-to-noise ratio, and spectral width for advanced analysis. There are two types of files for each station: wind data (files with a "w" prefix) and virtual temperature RASS data (files with a "t" prefix). The wind data files are in the format wYYDDD.cns, where YY is the 2-digit year and DDD is the day of the year. The RASS virtual temperature data files are in the format tYYDDD.cns. Each record has the following header structure: Line 1 : Station Name RASS files Line 2 : RASS rev DeTect_2.0, WINDS files Line 2 : WINDS rev ATI 5.1 Line 3 : N latitude, W longitude, and site elevation (m) Line 4 : Date and begin time of consensus: yy mm dd hh mn ss plus # minutes to add to get UTC Line 5 : Consensus averaging time (minutes); number of beams; number of range gates Line 6 : Number of records required to make consensus (num) total number of records (tot) and the consensus window size (m/s) in the format: num:tot (window) RASS files Line 7 : no. of coded cells, no. of spec, pulse width (ns), and inter-pulse period (µs), WINDS files Line 7 : No. of coded cells, no. of spectra, pulse width (ns), and inter-pulse period (µs), each with a pair of values: first value is for oblique beams, second for vertical RASS files Line 8 : Full scale Doppler value (m/s) Delay to first gate (ns) Number of gates Spacing of gates (ns), WINDS files Line 8 : Full scale Doppler velocity (m/s), oblique and vertical Vertical correction applied to oblique beams? (0 = no, 1 = yes) Delay to first gate (ns), oblique and vertical Number of gates, oblique and vertical Spacing of gates (ns), oblique and vertical Line 9 : Azimuth and elevation (9s indicate vertical beam not used) RASS files Line 10, values : HT = Height above ground (km), T = Uncorrected virtual temperature consensus (deg C), Tc = Corrected virtual temperature consensus (deg C), W = Vertical wind consensus (9s indicate vertical beam not used, w-component, positive upward, m/s), CNT = Number of records that made consensus (for the 3 values in same order), SNR = Average signal to noise ratio (dB) of records in consensus (same order) WINDS files Line 10, values : HT = Height above ground (km), SPD = Wind speed (m/s), DIR = Wind direction (deg E of N from N), RAD = Radial velocities for each beam (m/s) in order given in azimuth and elevation line (positive toward radar; 9s indicate vertical beam not used, CNT = Number of records that made consensus, SNR = Average signal to noise ratio (dB) of records in consensus

{"wind speed and direction",temperature}↗

Windsonde Atmospheric Profile during CoURAGE 2024-2025 at Kent Island.

This is the atmospheric sounding data using Sparv Windsond S1 lower-atmosphere profiling instruments ( https://sparv.io/products/windsond-s1) . These data are taken weekly (twice weekly and twice daily during the two CoURAGE IOPs in February and July 2025). Lower-atmosphere conditions, generally between the surface and 5km altitude, are recorded. The variables include pressure, height, temperature, dew-point temperature, wind speed, and wind direction.

air_temperature↗

Windsonde Atmospheric Profile during CoURAGE 2024-2025 at Baltimore.

This is the atmospheric sounding data using Sparv Windsond S1 lower-atmosphere profiling instruments ( https://sparv.io/products/windsond-s1) . These data are taken weekly (twice weekly and twice daily during the two CoURAGE IOPs in February and July 2025). Lower-atmosphere conditions, generally between the surface and 5km altitude, are recorded. The variables include pressure, height, temperature, dew-point temperature, wind speed, and wind direction.

air_temperature↗

CRGTBSO3 TBS Ozone Data

The Tethered Balloon System (TBS) operated for two weeks during a summer IOP of the CoURAGE campaign. This dataset includes data collected from an En-Sci electrochemical cell (ECC) ozonesonde on the TBS. The ozonesonde was connected to an iMet-4RSB radiosonde, and the overall data collected included ozone, relative humidity, temperature, and altitude. The data from the iMet is the same as that found in the TBSMERGED data product. The TBS also had another instrument (iMet XQ2) that collected meteorological data, which may have more accurate relative humidity (RH) data. This ozonesonde data set is intended to complement the TBSMERGED data product, the CRGTBSO3 surface ozone measurements, and the CoURAGE SWARM ozone lidar (TOLNet) measurements from other locations.

Atmospheric relative humidity↗