Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABERRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Advanced Imaging Optics Utilizing Wavefront Coding

Image processing offers a potential to simplify an optical system by shifting some of the imaging burden from lenses to the more cost effective electronics. Wavefront coding using a cubic phase plate combined with image processing can extend the system's depth of focus, reducing many of the focus-related aberrations as well as material related chromatic aberrations. However, the optimal design process and physical limitations of wavefront coding systems with respect to first-order optical parameters and noise are not well documented. We examined image quality of simulated and experimental wavefront coded images before and after reconstruction in the presence of noise. Challenges in the implementation of cubic phase in an optical system are discussed. In particular, we found that limitations must be placed on system noise, aperture, field of view and bandwidth to develop a robust wavefront coded system.

97 MATHEMATICS AND COMPUTING↗

Foil focusing of relativistic electron beams

When an intense relativistic electron beams (IREB) passes through a grounded metal foil, the transverse electric field due to the beam space charge is locally shorted out, and the beam is focused by the magnetic field of its current. The effect can be treated as focusing by a thin lens with first order aberration. Expressions for the focal length and aberration coefficient of the equivalent thin lens are developed in this note. These are then applied to practical examples representative of IREB research at Los Alamos National Laboratory.

43 PARTICLE ACCELERATORS↗

New Collins Quad Design

The Collins quadrupoles are used on the DARHT 2nd axis to transform the elliptical beam from the septum quadrupole back to a round beam. They are also used to minimize kicker smear by producing a point-to-point focus from the kicker to the target. The present Collins quads introduce significant aberrations due to the design of the iron pole tip. The effect of these aberrations becomes particularly large as the beam size in the Collins quads increases. This note describes an improved 2D pole tip design for the Collins quads developed using POISSON.

43 PARTICLE ACCELERATORS↗

RELATIVISTIC MEASUREMENTS FROM TIMING THE BINARY PULSAR PSR B1913+16

We present relativistic analyses of 9257 measurements of times-of-arrival from the first binary pulsar, PSR B1913+16, acquired over the last 35 years. The determination of the “Keplerian” orbital elements plus two relativistic terms completely characterizes the binary system, aside from an unknown rotation about the line of sight, leading to a determination of the masses of the pulsar and its companion: 1.438 ± 0.001 M {sub ☉} and 1.390 ± 0.001 M {sub ☉}, respectively. In addition, the complete system characterization allows for the creation of relativistic gravitation test by comparing measured and predicted sizes of various relativistic phenomena. We find that the ratio of the observed orbital period decrease caused by gravitational wave damping (corrected by a kinematic term) to the general relativistic prediction is 0.9983 ± 0.0016, thereby confirms the existence and strength of gravitational radiation as predicted by general relativity. For the first time in this system, we have also successfully measured the two parameters characterizing the Shapiro gravitational propagation delay, and found that their values are consistent with general relativistic predictions. For the first time in any system, we have also measured the relativistic shape correction to the elliptical orbit, δ {sub θ} , although its intrinsic value is obscured by currently unquantified pulsar emission beam aberration. We have also marginally measured the time derivative of the projected semimajor axis, which, when improved in combination with beam aberration modeling from geodetic precession observations, should ultimately constrain the pulsar’s moment of inertia.

79 ASTRONOMY AND ASTROPHYSICS↗

Retinal microvascular and neuronal pathologies probed in vivo by adaptive optical two-photon fluorescence microscopy

The retina, behind the transparent optics of the eye, is the only neural tissue whose physiology and pathology can be non-invasively probed by optical microscopy. The aberrations intrinsic to the mouse eye, however, prevent high-resolution investigation of retinal structure and function in vivo. Optimizing the design of a two-photon fluorescence microscope (2PFM) and sample preparation procedure, we found that adaptive optics (AO), by measuring and correcting ocular aberrations, is essential for resolving putative synaptic structures and achieving three-dimensional cellular resolution in the mouse retina in vivo. Applying AO-2PFM to longitudinal retinal imaging in transgenic models of retinal pathology, we characterized microvascular lesions with sub-capillary details in a proliferative vascular retinopathy model, and found Lidocaine to effectively suppress retinal ganglion cell hyperactivity in a retinal degeneration model. Tracking structural and functional changes at high-resolution longitudinally, AO-2PFM enables microscopic investigations of retinal pathology and pharmacology for disease diagnosis and treatment in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Aneuploidy induces premature aging in yeast due to defects in Ribosome Quality Control [RNASeqData]

Premature aging is a hallmark of Down syndrome, caused by trisomy of human chromosome 21; but the reason is unclear and difficult to study in humans. We used an aneuploid model in wild yeast to show that chromosome amplification disrupts nutrient-induced cell-cycle arrest, quiescence entry, and healthy aging, across genetic backgrounds and amplified chromosomes. We discovered that these defects are due in part to aneuploidy-induced dysfunction in Ribosome Quality Control (RQC). Aneuploids entering quiescence display aberrant ribosome profiles, accumulate RQC intermediates, and harbor an increased load of protein aggregates. Although they have normal proteasome capacity, aneuploids show signs of ubiquitin dysregulation, which impacts cyclin abundance to disrupt arrest. Remarkably, inducing ribosome stalling in euploids produces similar aberrations, while up-regulating limiting RQC subunits or proteins in ubiquitin metabolism alleviates many of the aneuploid defects. Our results raise major implications for other aneuploidy disorders including Down syndrome.

aneuploidy↗

Aneuploidy induces premature aging in yeast due to defects in Ribosome Quality Control [MoBYSeqData]

Premature aging is a hallmark of Down syndrome, caused by trisomy of human chromosome 21; but the reason is unclear and difficult to study in humans. We used an aneuploid model in wild yeast to show that chromosome amplification disrupts nutrient-induced cell-cycle arrest, quiescence entry, and healthy aging, across genetic backgrounds and amplified chromosomes. We discovered that these defects are due in part to aneuploidy-induced dysfunction in Ribosome Quality Control (RQC). Aneuploids entering quiescence display aberrant ribosome profiles, accumulate RQC intermediates, and harbor an increased load of protein aggregates. Although they have normal proteasome capacity, aneuploids show signs of ubiquitin dysregulation, which impacts cyclin abundance to disrupt arrest. Remarkably, inducing ribosome stalling in euploids produces similar aberrations, while up-regulating limiting RQC subunits or proteins in ubiquitin metabolism alleviates many of the aneuploid defects. Our results raise major implications for other aneuploidy disorders including Down syndrome.

aneuploidy↗

Premature aging in aneuploid yeast is influenced by aneuploidy-induced defects in Ribosome Quality Control [RiboSeq]

Premature aging is a hallmark of Down syndrome, caused by trisomy of human chromosome 21; but the reason is unclear and difficult to study in humans. We used an aneuploid model in wild yeast to show that chromosome amplification disrupts nutrient-induced cell-cycle arrest, quiescence entry, and healthy aging, across genetic backgrounds and amplified chromosomes. We discovered that these defects are due in part to aneuploidy-induced dysfunction in Ribosome Quality Control (RQC). Aneuploids entering quiescence display aberrant ribosome profiles, accumulate RQC intermediates, and harbor an increased load of protein aggregates. Although they have normal proteasome capacity, aneuploids show signs of ubiquitin dysregulation, which impacts cyclin abundance to disrupt arrest. Remarkably, inducing ribosome stalling in euploids produces similar aberrations, while up-regulating limiting RQC subunits or proteins in ubiquitin metabolism alleviates many of the aneuploid defects. Our results raise major implications for other aneuploidy disorders including Down syndrome.

aneuploidy↗

Application of Monte Carlo techniques to optimization of high-energy beam transport in a stochastic environment

An algorithm employing a modified sequential random perturbation, or creeping random search, was applied to the problem of optimizing the parameters of a high-energy beam transport system. The stochastic solution of the mathematical model for first-order magnetic-field expansion allows the inclusion of state-variable constraints, and the inclusion of parameter constraints allowed by the method of algorithm application eliminates the possibility of infeasible solutions. The mathematical model and the algorithm were programmed for a real-time simulation facility; thus, two important features are provided to the beam designer: (1) a strong degree of man-machine communication (even to the extent of bypassing the algorithm and applying analog-matching techniques), and (2) extensive graphics for displaying information concerning both algorithm operation and transport-system behavior. Chromatic aberration was also included in the mathematical model and in the optimization process. Results presented show this method as yielding better solutions (in terms of resolutions) to the particular problem than those of a standard analog program as well as demonstrating flexibility, in terms of elements, constraints, and chromatic aberration, allowed by user interaction with both the algorithm and the stochastic model. Example of slit usage and a limited comparison of predicted results and actual results obtained with a 600 MeV cyclotron are given.

Parrish, R. V.↗

A general purpose wideband optical spatial frequency spectrum analyzer

The light scattered at various angles by a transparent media is studied. An example of these applications is the optical Fourier spectrum measurement resulting from various spatial frequencies which were recorded on a photographic emulsion. A method for obtaining these measurements consists of illuminating the test object with parallel monochromatic light. A stationary lens, placed in the resulting wavefield at a distance of one focal length from the object, will focus parallel waves emanating from the test object at a point lying in the focal plane of the lens. A light detector with a small filtering aperture is then used to measure the intensity variation of the light in the focal or transform plane of the lens. Such measurements require the use of a lens which is highly corrected for all of the common aberrations except chromatic aberration.

Ballard, G. S.↗

In-situ measurement of objective lens data of a high-resolution electron microscope.

Bragg-reflex images of small individual crystallites in the size range of 20-100 A diameter with known crystallographic orientation were used in a transmission electron microscope to determine in-situ: (a) the relationship between objective lens current (or accelerating voltage) changes in discrete steps and corresponding defocus, (b) the spherical aberration coefficient, and (c) the axial chromatic aberration coefficient of the objective lens. The accuracy of the described method is better than 5%. The same specimen can advantageously be used to properly aline the illuminating beam with respect to the optical axis.

Heinemann, K.↗

Anastigmatic three-mirror telescope

A three-mirror telescope arrangement that can be corrected for four aberrations (coma, spherical aberration, field curvature, and astigmatism) is described. Geometric spot size is less than 0.1 sec of arc, in an easily accessible flat field of 1.5 deg. The primary-secondary configuration is Cassegrain-like, with the real image formed closely behind the primary. This secondary image is re-imaged by a tertiary mirror at roughly unit magnification. A small, flat mirror at the exit pupil, located between primary and tertiary, folds the light rectangularly away from the telescope axis. The shape of the large image area is helpful in space applications where several instruments may share the focal plane.

Korsch, D.↗

Performance analysis of grazing incidence imaging systems

An exact expression relating the coordinates of a point on the incident ray, a point of reflection from an arbitrary surface, and a point on the reflected ray is derived. The exact relation is then specialized for the case of grazing incidence, and first order and third order systematic analyses are carried out for a single reflective surface and then for a combination of two surfaces. The third order treatment yields a complete set of primary aberrations for single element and two element systems. The importance of a judicious choice for a coordinate system in showing field curvature to clearly be the predominant aberration for a two element system is discussed. The validity of the theory is verified through comparisons with the exact ray trace results for the case of the telescope.

Winkler, C. E.↗

Effect of ultrasonic irradiation on mammalian cells and chromosomes in vitro

Human peripheral blood and HeLa cells were irradiated in vitro at the ultrasonic frequency of 65 kHz. The whole blood and HeLa cell suspensions were exposed to continuous and pulsed ultrasonic power levels of 0.12, 0.16, 0.72, 1.12 and 2.24 W for a period of one minute. The method of ultrasonic irradiation was carried out with the whole blood or HeLa cell suspensions coupled directly to a cylindrical transducer while heating of the cell suspensions in excess of 41 C was avoided. Irradiated and unirradiated peripheral blood lymphocyte chromosome cultures were prepared and scored for selected numerical and morphological aberrations. There was no significant difference in the frequency of chromosomal aberrations between irradiated and unirradiated cells.

Roseboro, J. A.↗

A high resolution holographic particle sizing system

This paper will review briefly the requirements of holography with respect to particle sizing techniques. A holographic construction system and the appropriate reconstruction system will be discussed regarding their characteristics and performance (i.e. system resolution, magnification, system aberration and correction of aberrations, and maximum total test volume). The capabilities of a commercial particle sizing system used to obtain particle sizes and distribution information from reconstructed holograms will be described and characterized. It will be shown that by using the methods described, high resolution throughout large test volumes can be achieved.

Witherow, W. K.↗

A note on the location of the stagnation point in the magnetosheath flow

While observational and theoretical investigations have clearly indicated that the shape of the magnetosphere is very nearly symmetric about the plane determined by the aberrated solar wind flow direction and the earth's magnetic dipole, many processes such as magnetic pulsations and geomagnetic activity which should be shape dependent do not exhibit symmetry about this plane. The present paper proposes a solution to this apparent paradox in terms of the shifting of the stagnation point in the magnetosheath flow. It is shown that the interplanetary magnetic field can act to shift the stagnation point on the order of 15 deg from the nose towards dawn during periods of low Alfven Mach number without an appreciable aberration of the magnetopause, accounting for the observations of pulsation demarcation and magnetic reconnection.

Russell, C. T.↗

Development of a tantalum pentoxide Luneberg lens

A process has been developed for the fabrication of a tantalum pentoxide waveguide Luneburg lens as the input collimator for an optical signal processing circuit on a silicon substrate, such as an integrated wavelength demultiplexer. The development of such a lens involved improvement of the deposition mask profile, reduction of surface scattering by underlaying the lens, reduction of edge scattering by using shims under the mask, and prediction and measurement of the TE-TM polarization aberration. It is shown that polarization aberration significantly affects the design of a demultiplexer system.

Bryan, D. A.↗

Variable line-space gratings - New designs for use in grazing incidence spectrometers

An account is given of a fundamentally different approach to the use of variable line-space gratings for grazing incidence spectrometers. In the new approach, the gratings are flat and they are placed to intercept the converging beam from a collecting mirror rather than the diverging beam from a slit. This results in (1) small aberrations over a wide instantaneous range in wavelength, (2) a modest required variation in line spacing across the ruled width, (3) a simultaneous minimization of both the spectral and image height aberrations, and (4) a completely stigmatic zero order image. The slitless arrangement common to these designs is very compact, having no additional length behind the focal plane of the collecting mirror. In-plane and conical fan designs are considered. One combination design, in the form of an echelle spectrometer, is discussed. The designs are considered to represent ideal candidates for moderate to high resolution spectrometers on such missions as the Far Ultraviolet Spectroscopic Explorer (FUSE, now Columbus) and the Advanced X-ray Astrophysics Facility (AXAF).

Hettrick, M. C.↗