Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “39”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Consequences of Spatial Antisymmetry on Light

Light propagation in two and three dimensional lattices for which the index of refraction exhibits spatial antisymmetry is investigated in the ray and photonic crystal regimes. In these regimes, all the two dimensional antisymmetry groups for which light fails to propagate are identified. In the ray-regime, it is observed that in tilings described by 7 of the 46 two dimensional antisymmetric groups, light is localized within a fundamental domain and does not propagate through the tiling, in contrast to the behavior in the other 39 groups. To understand the above phenomenon, a rule based on the number of anti-mirror planes passing through a single Bravais lattice point is derived. In the wave regime for photonic crystals, it is observed that there are no propagating eigensolutions for the same 7 tilings as above, whereas propagating solutions and energy pass band dispersion curves can be obtained for the other 39 groups. The reasons underlying this peculiar behavior are analyzed using the topological approach for modeling flow in dynamical billiards to shed light on the applicability of Bloch's theorem for these periodic antisymmetric lattices.

36 MATERIALS SCIENCE↗

An investigation on the capabilities of the PENELOPE MC code in nanodosimetry

The Monte Carlo (MC) method has been widely implemented in studies of radiation effects on human genetic material. Most of these works have used specific-purpose MC codes to simulate radiation transport in condensed media. PENELOPE is one of the general-purpose MC codes that has been used in many applications related to radiation dosimetry. Based on the fact that PENELOPE can carry out event-by-event coupled electron-photon transport simulations following these particles down to energies of the order of few tens of eV, we have decided to investigate the capacities of this code in the field of nanodosimetry. Single and double strand break probabilities due to the direct impact of {gamma} rays originated from Co{sup 60} and Cs{sup 137} isotopes and characteristic x-rays, from Al and C K-shells, have been determined by use of PENELOPE. Indirect damage has not been accounted for in this study. A human genetic material geometrical model has been developed, taking into account five organizational levels. In an article by Friedland et al. [Radiat. Environ. Biophys. 38, 39-47 (1999)], a specific-purpose MC code and a very sophisticated DNA geometrical model were used. We have chosen that work as a reference to compare our results. Single and double strand-break probabilities obtained here underestimate those reported by Friedland and co-workers by 20%-76% and 50%-60%, respectively. However, we obtain RBE values for Cs{sup 137}, Al{sub K} and C{sub K} radiations in agreement with those reported in previous works [Radiat. Environ. Biophys. 38, 39-47 (1999)] and [Phys. Med. Biol. 53, 233-244 (2008)]. Some enhancements can be incorporated into the PENELOPE code to improve its results in the nanodosimetry field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27{+-}52.97 to 14.98 mm{+-}11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A further investigation of the centroid-to-centroid method for stereotactic lung radiotherapy: A phantom study

Purpose: Our previous study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] proposed a deformable-registration-based patient setup strategy called the centroid-to-centroid (CTC) method, which can perform an accurate alignment of internal-target-volume (ITV) centroids between averaged four-dimensional computed tomography and cone-beam computed tomography (CBCT) images. Scenarios with variations between CBCT and simulation CT caused by irregular breathing and/or tumor change were not specifically considered in the patient study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] due to the lack of both a sufficiently large patient data sample and a method of tumor tracking. The aim of this study is to thoroughly investigate and compare the impacts of breathing pattern and tumor change on both the CTC and the translation-only (T-only) gray-value mode strategies by employing a four-dimensional (4D) lung phantom.Methods: A sophisticated anthropomorphic 4D phantom (CIRS Dynamic Thorax Phantom model 008) was employed to simulate all desired respiratory variations. The variation scenarios were classified into four groups: inspiration to expiration ratio (IE ratio) change, tumor trajectory change, tumor position change, tumor size change, and the combination of these changes. For each category the authors designed several scenarios to demonstrate the effects of different levels of breathing variation on both of the T-only and the CTC methods. Each scenario utilized 4DCT and CBCT scans. The ITV centroid alignment discrepancies for CTC and T-only were evaluated. The dose-volume-histograms (DVHs) of ITVs for two extreme cases were analyzed.Results: Except for some extreme cases in the combined group, the accuracy of the CTC registration was about 2 mm for all cases for both the single and the combined scenarios. The performance of the CTC method was insensitive to region-of-registration (ROR) size selections, as suggested by the comparable accuracy between 1 and 2 cm expansions of the ROR selections for the method. The T-only method was suitable for some single scenarios, such as trajectory variation, position variation, and size variation. However, for combined scenarios and/or a large variation in the IE ratio, the T-only method failed to produce reasonable registration results (within 3 mm). The discrepancy was close to, or even greater than, 1 cm. In addition, unlike the CTC method, the T-only method was sensitive to the ROR size selection. The DVH analysis suggested that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.Conclusions: The phantom study demonstrated that the CTC method was reliable for scenarios in which breathing pattern variation was involved. The T-only gray value method worked for some scenarios, but not for scenarios that involved an IE ratio variation. For scenarios involving position variation, the T-only method worked only with a careful selection of the ROR, whereas the CTC method was independent of ROR size as long as the ITVs were included in the ROR. One indication of the dose consequence analysis was that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of burst and recombination models for Monte Carlo transport of interacting carriers in a-Se x-ray detectors on Swank noise

Purpose: The authors describe the modification to a previously developed Monte Carlo model of semiconductor direct x-ray detector required for studying the effect of burst and recombination algorithms on detector performance. This work provides insight into the effect of different charge generation models for a-Se detectors on Swank noise and recombination fraction. Methods: The proposed burst and recombination models are implemented in the Monte Carlo simulation package, ARTEMIS, developed byFang et al. [“Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se,” Med. Phys. 39(1), 308–319 (2012)]. The burst model generates a cloud of electron-hole pairs based on electron velocity, energy deposition, and material parameters distributed within a spherical uniform volume (SUV) or on a spherical surface area (SSA). A simple first-hit (FH) and a more detailed but computationally expensive nearest-neighbor (NN) recombination algorithms are also described and compared. Results: Simulated recombination fractions for a single electron-hole pair show good agreement with Onsager model for a wide range of electric field, thermalization distance, and temperature. The recombination fraction and Swank noise exhibit a dependence on the burst model for generation of many electron-hole pairs from a single x ray. The Swank noise decreased for the SSA compared to the SUV model at 4 V/μm, while the recombination fraction decreased for SSA compared to the SUV model at 30 V/μm. The NN and FH recombination results were comparable. Conclusions: Results obtained with the ARTEMIS Monte Carlo transport model incorporating drift and diffusion are validated with the Onsager model for a single electron-hole pair as a function of electric field, thermalization distance, and temperature. For x-ray interactions, the authors demonstrate that the choice of burst model can affect the simulation results for the generation of many electron-hole pairs. The SSA model is more sensitive to the effect of electric field compared to the SUV model and that the NN and FH recombination algorithms did not significantly affect simulation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On multichannel film dosimetry with channel-independent perturbations

Purpose: Different multichannel methods for film dosimetry have been proposed in the literature. Two of them are the weighted mean method and the method put forth byMicke et al. [“Multichannel film dosimetry with nonuniformity correction,” Med. Phys. 38, 2523–2534 (2011)] and Mayer et al. [“Enhanced dosimetry procedures and assessment for EBT2 radiochromic film,” Med. Phys. 39, 2147–2155 (2012)]. The purpose of this work was to compare their results and to develop a generalized channel-independent perturbations framework in which both methods enter as special cases. Methods: Four models of channel-independent perturbations were compared: weighted mean, Micke–Mayer method, uniform distribution, and truncated normal distribution. A closed-form formula to calculate film doses and the associated type B uncertainty for all four models was deduced. To evaluate the models, film dose distributions were compared with planned and measured dose distributions. At the same time, several elements of the dosimetry process were compared: film type EBT2 versus EBT3, different waiting-time windows, reflection mode versus transmission mode scanning, and planned versus measured dose distribution for film calibration and for γ-index analysis. The methods and the models described in this study are publicly accessible through IRISEU. Alpha 1.1 ( http://www.iriseu.com ). IRISEU. is a cloud computing web application for calibration and dosimetry of radiochromic films. Results: The truncated normal distribution model provided the best agreement between film and reference doses, both for calibration and γ-index verification, and proved itself superior to both the weighted mean model, which neglects correlations between the channels, and the Micke–Mayer model, whose accuracy depends on the properties of the sensitometric curves. With respect to the selection of dosimetry protocol, no significant differences were found between transmission and reflection mode scanning, between 75 ± 5 min and 20 ± 1 h waiting-time windows or between employing EBT2 or EBT3 films. Significantly better results were obtained when a measured dose distribution was used instead of a planned one as reference for the calibration, and when a planned dose distribution was used instead of a measured one as evaluation for the γ-analysis. Conclusions: The truncated normal distribution model of channel-independent perturbations was found superior to the other three models under comparison and the authors propose its use for multichannel dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving the energy response of external beam therapy (EBT) GafChromic{sup TM} dosimetry films at low energies (≤100 keV)

Purpose: Purpose of this work is to investigate the effects of varying the active layer composition of external beam therapy (EBT) GafChromic{sup TM} films on the energy dependence of the film, as well as try to develop a new prototype with more uniform energy response at low photon energies (⩽100 keV). Methods: First, the overall energy response (S{sub AD,} {sub W}(Q)) of different commercial EBT type film models that represent the three different generations produced to date, i.e., EBT, EBT2, and EBT3, was investigated. Pieces of each film model were irradiated to a fixed dose of 2 Gy to water for a wide range of beam qualities and the corresponding S{sub AD,} {sub W}(Q) was measured using a flatbed document scanner. Furthermore, the DOSRZnrc Monte Carlo code was used to determine the absorbed dose to water energy dependence of the film, f(Q). Moreover, the intrinsic energy dependence, k{sub bq}(Q), for each film model was evaluated using the corresponding S{sub AD,} {sub W}(Q) and f(Q). In the second part of this study, the authors investigated the effects of changing the chemical composition of the active layer on S{sub AD,} {sub W}(Q). Finally, based on these results, the film manufacturer fabricated several film prototypes and the authors evaluated their S{sub AD,} {sub W}(Q). Results: The commercial EBT film model shows an under response at all energies below 100 keV reaching 39% ± 4% at about 20 keV. The commercial EBT2 and EBT3 film models show an under response of about 27% ± 4% at 20 keV and an over response of about 16% ± 4% at 40 keV.S{sub AD,} {sub W}(Q) of the three commercial film models at low energies show strong correlation with the corresponding f{sup −1}(Q) curves. The commercial EBT3 model with 4% Cl in the active layer shows under response of 22% ± 4% at 20 keV and 6% ± 4% at about 40 keV. However, increasing the mass percent of chlorine makes the film more hygroscopic which may affect the stability of the film's readout. The EBT3 film prototype with 7.5% Si shows a significant improvement in the energy response at very low energies compared to the commercial EBT3 films with 4% Cl. It shows under response of 15% ± 5% at about 20 keV to 2% ± 5% at about 40 keV. However, according to the manufacturer, the addition of 7.5% Si as SiO{sub 2} adversely affected the viscosity of the active fluid and therefore affected the potential use in commercial machine coating. The latest commercial EBT3 film model with 7% Al as Al{sub 2}O{sub 3} shows an overall improvement in S{sub AD,} {sub W}(Q) compared to previous commercial EBT3 films. It shows under response at all energies <100 keV, varying from 20% ± 4% at 20 keV to 6% ± 4% at 40 keV. Conclusions: The energy response of films in the energy range <100 keV can be improved by adjusting the active layer chemical composition. Removing bromine eliminated the over response at about 40 keV. The under response at energies ≤30 keV is improved by adding 7% Al to the active layer in the latest commercial EBT3 film models.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-85: Comparison of Treatment Plans Calculated Using Ray Tracing and Monte Carlo Algorithms for Lung Cancer Patients Having Undergone Radiotherapy with Cyberknife

Purpose: The latest publications indicate that the Ray Tracing algorithm significantly overestimates the dose delivered as compared to the Monte Carlo (MC) algorithm. The purpose of this study is to quantify this overestimation and to identify significant correlations between the RT and MC calculated dose distributions. Methods: Preliminary results are based on 50 preexisting RT algorithm dose optimization and calculation treatment plans prepared on the Multiplan treatment planning system (Accuray Inc., Sunnyvale, CA). The analysis will be expanded to include 100 plans. These plans are recalculated using the MC algorithm, with high resolution and 1% uncertainty. The geometry and number of beams for a given plan, as well as the number of monitor units, is constant for the calculations for both algorithms and normalized differences are compared. Results: MC calculated doses were significantly smaller than RT doses. The D95 of the PTV was 27% lower for the MC calculation. The GTV and PTV mean coverage were 13 and 39% less for MC calculation. The first parameter of conformality, as defined as the ratio of the Prescription Isodose Volume to the PTV Volume was on average 1.18 for RT and 0.62 for MC. Maximum doses delivered to OARs was reduced in the MC plans. The doses for 1000 and 1500 cc of total lung minus PTV, respectively were reduced by 39% and 53% for the MC plans. The correlation of the ratio of air in PTV to the PTV with the difference in PTV coverage had a coefficient of −0.54. Conclusion: The preliminary results confirm that the RT algorithm significantly overestimates the dosages delivered confirming previous analyses. Finally, subdividing the data into different size regimes increased the correlation for the smaller size PTVs indicating the MC algorithm improvement verses the RT algorithm is dependent upon the size of the PTV.

60 APPLIED LIFE SCIENCES↗

Tailoring automatic exposure control toward constant detectability in digital mammography

Purpose: The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. Methods: The default “OPDOSE” AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d′), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (T{sub t}) in the European guidelines for the 0.1 mm diameter disc (i.e., T{sub t} ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (T{sub t}), calculated detectability (d′), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. Results: The default OPDOSE AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d′ 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d′), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default AEC mode in the homogeneous background increased by 62% in going from 20 to 70 mm PMMA thickness; in the structured background, the increase was 39%. Implementation of the modified mode entailed an increase in mAs at PMMA thicknesses >40 mm; the modified AEC held threshold gold thickness constant above 40 mm PMMA with a maximum deviation of 5% in the homogeneous background and 3% in structured background. SDNR was also held constant with a maximum deviation of 4% and 2% for the homogeneous and the structured background, respectively. These results were obtained with an increase of MGD between 15% and 73% going from 40 to 70 mm PMMA thickness. Conclusions: This work has proposed and implemented a modified AEC mode, tailored toward constant detectability at larger breast thickness, i.e., above 40 mm PMMA equivalent. The desired improvement in object detectability could be obtained while maintaining MGD within the European guidelines achievable dose limit. (A study designed to verify the performance of the modified mode using more clinically realistic data is currently underway.)

60 APPLIED LIFE SCIENCES↗

Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study

Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications of different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm{sup 2}, and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm{sup 2} (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety of this method in the whole orbit especially regarding potential adverse optic nerve heating at the location of the bone.

60 APPLIED LIFE SCIENCES↗

Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy.

60 APPLIED LIFE SCIENCES↗

Synthesis and crystal structure of a new organic compound: Bis(4,4 Prime -diaminodiphenylmethane) (4,4 Prime -diammoniodiphenylmethane) dichloride monohydrate

A new organic compound with the formula C{sub 39}H{sub 46}Cl{sub 2}N{sub 6}O was synthesized from aqueous solution of 4,4 Prime -diaminodiphenylmethane and hydrochloric acid at room temperature. This compound crystallizes in the monoclinic space group C2: a = 25.6525(16), b = 5.7107(3), c = 13.7777(8) A, {beta} = 118.862(2) Degree-Sign , V = 1767.64(22) A{sup 3} and Z = 2, giving D{sub x} = 1.288 g cm{sup -3}. The refinement converged to R{sub 1} = 0.027 and wR{sub 2} = 0.0649. The structural arrangement can be described as infinite layers parallel to bc plane. In these layers cations and non protonated molecules are linked with N-H...N hydrogen bonds building [C{sub 39}H{sub 44}N{sub 6}]{sup 2+} organic clusters. These clusters, in turn, are linked by N-H...Cl and O-H...Cl hydrogen bonds.

36 MATERIALS SCIENCE↗

First-Line Gemcitabine and Nab-Paclitaxel Chemotherapy for Localized Pancreatic Ductal Adenocarcinoma

Background: Preoperative chemotherapy provides early treatment of micro-metastases and guaranteed delivery of all components of multimodality therapy for localized pancreatic ductal adenocarcinoma (PDAC). For locally advanced (LA) PDAC, induction chemotherapy is the standard of care. This study evaluated the use of gemcitabine and nab-paclitaxel (Gem/nab-P) as first-line therapy for localized PDAC. Methods: Clinicopathologic features, treatment, and outcomes were evaluated for 99 patients with localized PDAC. The patients were staged using previously published criteria as follows: potentially resectable (PR), borderline type A (BR-A) (anatomy amenable to vascular resection), BR-B (biology suspicious for metastatic disease including high CA19-9), BR–C (comorbidities requiring medical optimization), and LA. Results: The 99 patients (PR/BR/LA: 45/14/40) were treated with Gem/nab-P. Clinical staging showed that 20 patients had PR or BR-A disease, whereas 39 patients had BR-B or BR-C disease. The BR-B+C cases included one or more of the following: age of 80 years or older (13%), Eastern Cooperative Oncology Group performance status (ECOG PS) of 2 or more (13%), moderate to severe comorbidities (55%), CA19-9 of 1000 or higher (28%), and suspicion for metastases (21%). The majority of the patients received biweekly Gem/nab-P dosing, which was well tolerated. Pancreatectomy was performed for 12 (60%) of 20 patients with PR+BR-A, 2 (5%) of 39 patients with BR-B+C, and 1 (3%) of 40 patients with LA disease. During a median follow-up period of 26 months, the median overall survival (OS) period was 18 months (95% confidence interval [CI], 15.6–20.5 months) for all the patients, 17 months (95% CI, 14.6–19.5 months) for the unresected patients, and not reached for the resected patients (p = 0.028 for resected vs unresected patients). Conclusions: A significant number of patients with radiographically resectable PDAC albeit aggressive biology (BR-B), medically inoperable conditions (BR-C), or both received biweekly first-line Gem/nab-P. The resection rates were lower for the BR-B/BR-C patients than for the PR/BR-A patients (hazard ratio [HR], 0.43; 95% CI, 0.19–1.00; p = 0.05).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hashes are not suitable to verify fixity of the public archived web

Web archives, such as the Internet Archive, preserve the web and allow access to prior states of web pages. We implicitly trust their versions of archived pages, but as their role moves from preserving curios of the past to facilitating present day adjudication, we are concerned with verifying the fixity of archived web pages, or mementos, to ensure they have always remained unaltered. A widely used technique in digital preservation to verify the fixity of an archived resource is to periodically compute a cryptographic hash value on a resource and then compare it with a previous hash value. If the hash values generated on the same resource are identical, then the fixity of the resource is verified. We tested this process by conducting a study on 16,627 mementos from 17 public web archives. We replayed and downloaded the mementos 39 times using a headless browser over a period of 442 days and generated a hash for each memento after each download, resulting in 39 hashes per memento. The hash is calculated by including not only the content of the base HTML of a memento but also all embedded resources, such as images and style sheets. We expected to always observe the same hash for a memento regardless of the number of downloads. However, our results indicate that 88.45% of mementos produce more than one unique hash value, and about 16% (or one in six) of those mementos always produce different hash values. We identify and quantify the types of changes that cause the same memento to produce different hashes. These results point to the need for defining an archive-aware hashing function, as conventional hashing functions are not suitable for replayed archived web pages.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Simulation of Device Parameters of High Efficiency Multicrystalline Silicon Solar Cells

The results of the simulation of the reported experimental results of high efficiency multicrystalline silicon (mc-Si) solar cells, using PC1D software, are reported in this study. Results obtained by various groups have been incorporated and compared in this study. The highest efficiency reported so far for mc-Si solar cells is 20{center_dot}4% and 17-18% by research laboratories and commercial houses, respectively. The efficiency can be further enhanced if passivation characteristics on both the front and back surface are improved. The role of back surface recombination has become more significant in light of the use of thin mc-Si wafers by the solar cell industry. Based on the passivation characteristics and considering the understanding of the past three decades of studies, the authors have proposed and simulated a structure for mc-Si solar cells to improve the performance of the same. The results of our modeled structure of mc-Si solar cell show an efficiency of 21{center_dot}88% with short-circuit current density, J{sub sc} = 39{center_dot}39 mA/cm2, and open circuit voltage, V{sub oc} = 0{center_dot}666 V.

14 SOLAR ENERGY↗

Materials Data on NaPr2IrO6 by Materials Project

NaPr2IrO6 crystallizes in the monoclinic P2_1/c space group. The structure is three-dimensional. Na1+ is bonded to six O2- atoms to form NaO6 octahedra that share corners with six equivalent IrO6 octahedra. The corner-sharing octahedra tilt angles range from 35–39°. There are a spread of Na–O bond distances ranging from 2.28–2.35 Å. Pr3+ is bonded in a 8-coordinate geometry to eight O2- atoms. There are a spread of Pr–O bond distances ranging from 2.36–2.92 Å. Ir5+ is bonded to six O2- atoms to form IrO6 octahedra that share corners with six equivalent NaO6 octahedra. The corner-sharing octahedra tilt angles range from 35–39°. All Ir–O bond lengths are 2.00 Å. There are three inequivalent O2- sites. In the first O2- site, O2- is bonded in a 5-coordinate geometry to one Na1+, three equivalent Pr3+, and one Ir5+ atom. In the second O2- site, O2- is bonded to one Na1+, two equivalent Pr3+, and one Ir5+ atom to form distorted corner-sharing ONaPr2Ir trigonal pyramids. In the third O2- site, O2- is bonded in a 5-coordinate geometry to one Na1+, three equivalent Pr3+, and one Ir5+ atom.

36 MATERIALS SCIENCE↗

Materials Data on NaLa2OsO6 by Materials Project

NaLa2OsO6 crystallizes in the monoclinic P2_1/c space group. The structure is three-dimensional. Na1+ is bonded to six O2- atoms to form NaO6 octahedra that share corners with six equivalent OsO6 octahedra. The corner-sharing octahedra tilt angles range from 34–39°. There are a spread of Na–O bond distances ranging from 2.32–2.38 Å. La3+ is bonded in a 8-coordinate geometry to eight O2- atoms. There are a spread of La–O bond distances ranging from 2.38–2.98 Å. Os5+ is bonded to six O2- atoms to form OsO6 octahedra that share corners with six equivalent NaO6 octahedra. The corner-sharing octahedra tilt angles range from 34–39°. There is four shorter (1.99 Å) and two longer (2.00 Å) Os–O bond length. There are three inequivalent O2- sites. In the first O2- site, O2- is bonded in a 5-coordinate geometry to one Na1+, three equivalent La3+, and one Os5+ atom. In the second O2- site, O2- is bonded to one Na1+, two equivalent La3+, and one Os5+ atom to form distorted corner-sharing ONaLa2Os tetrahedra. In the third O2- site, O2- is bonded in a 5-coordinate geometry to one Na1+, three equivalent La3+, and one Os5+ atom.

36 MATERIALS SCIENCE↗

Materials Data on ZnPbF6 by Materials Project

ZnPbF6 crystallizes in the trigonal R-3 space group. The structure is three-dimensional. Zn2+ is bonded to six equivalent F1- atoms to form ZnF6 octahedra that share corners with six equivalent PbF6 octahedra. The corner-sharing octahedral tilt angles are 39°. All Zn–F bond lengths are 2.05 Å. Pb4+ is bonded to six equivalent F1- atoms to form PbF6 octahedra that share corners with six equivalent ZnF6 octahedra. The corner-sharing octahedral tilt angles are 39°. All Pb–F bond lengths are 2.11 Å. F1- is bonded in a bent 150 degrees geometry to one Zn2+ and one Pb4+ atom.

36 MATERIALS SCIENCE↗