Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Loss-of-Control-Inhibitor Systems for Aircraft

Systems to provide improved tactile feedback to aircraft pilots are being developed to help the pilots maintain harmony between their control actions and the positions of aircraft control surfaces, thereby helping to prevent loss of control. A system of this type, denoted a loss-of-control-inhibitor system (LOCIS) can be implemented as a relatively simple addition to almost any pre-existing flight-control system. The LOCIS concept offers at least a partial solution to the problem of (1) keeping a pilot aware of the state of the control system and the aircraft and (2) maintaining sufficient control under conditions that, as described below, have been known to lead to loss of control. Current commercial aircraft exhibit uneven responses of primary flight-control surfaces to aggressive pilot control commands, leading to deterioration of pilots ability to control their aircraft. In severe cases, this phenomenon can result in loss of control and consequent loss of aircraft. For an older aircraft equipped with a purely mechanical control system, the loss of harmony between a pilot s command action and the control- surface response can be attributed to compliance in the control system (caused, for example, by stretching of control cables, flexing of push rods, or servo-valve distortion). In a newer aircraft equipped with a fly-by-wire control system, the major contributions to loss of harmony between the pilot and the control surfaces are delays attributable to computer cycle time, control shaping, filtering, aliasing, servo-valve distortion, and actuator rate limiting. In addition, a fly-by-wire control system provides no tactile feedback that would enable the pilot to sense such features of the control state as surface flutter, surface jam, position limiting, actuator rate limiting, and control limiting imposed by the aircraft operational envelope. Hence, for example, when a pilot is involved in aggressive closed-loop maneuvering, as when encountering a wake-vortex upset on final landing approach, the control-surface delay can lead to loss of control. Aggressive piloting can be triggered and exacerbated by control-system anomalies, which the pilot cannot diagnose because of the lack of symptoms caused by the absence of feedback through the controls. The purpose served by a LOCIS is to counteract these adverse effects by providing real-time feedback that notifies the pilot that the aircraft is tending to lag the pilot s commands. A LOCIS (see figure) includes cockpit control input-position sensors, control-surface output-position sensors, variable dampers (for example, shock absorbers containing magneto-rheological fluids such that the damping forces can be varied within times of the order of milliseconds by varying applied magnetic fields) attached to the cockpit control levers, electromagnet coils to apply the magnetic fields, and feedback control circuits to drive the electromagnet coils. The feedback control gains are chosen so that the current applied to each electromagnet coil results in a damping force that increases in a suitable nonlinear manner (e.g., exponentially) with the difference between the actual and commanded positions of the affected control surface. The increasing damping force both alerts the pilot to the onset of a potentially dangerous situation and resists the pilot s effort to command a control surface to change position at an excessive rate

AHarrah, Ralph C.↗

The Cosmic Battery Revisited

We reinvestigate the generation and accumulation of magnetic flux in optically thin accretion flows around active gravitating objects. The source of the magnetic field is the azimuthal electric current associated with the Poynting-Robertson drag on the electrons of the accreting plasma. This current generates magnetic field loops which open up because of the differential rotation of the flow. We show through simple numerical simulations that what regulates the generation and accumulation of magnetic flux near the center is the value of the plasma conductivity. Although the conductivity is usually considered to be effectively infinite for the fully ionized plasmas expected near the inner edge of accretion disks, the turbulence of those plasmas may actually render them much less conducting due to the presence of anomalous resistivity. We have discovered that if the resistivity is sufficiently high throughout the turbulent disk while it is suppressed interior to its inner edge, an interesting steady-state process is established: accretion carries and accumulates magnetic flux of one polarity inside the inner edge of the disk, whereas magnetic diffusion releases magnetic flux of the opposite polarity to large distances. In this scenario, magnetic flux of one polarity grows and accumulates at a steady rate in the region inside the inner edge and up to the point of equipartition when it becomes dynamically important. We argue that this inward growth and outward expulsion of oppositely-directed magnetic fields that we propose may account for the approx. 30 min cyclic variability observed in the galactic microquasar GRS1915+105.

Contopoulos, Ioannis↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗

Duct wall impedance control as an advanced concept for acoustic impression

Models and tests on an acoustic duct liner system which has the property of controlled-variable acoustic impedance are described. This is achieved by a novel concept which uses the effect of steady air flow through a multi-layer, locally reacting, resonant-cavity absorber. The scope of this work was limited to a 'proof of concept.' The test of the concept was implemented by means of a small-scale, square-section flow duct facility designed specifically for acoustic measurements, with one side of the duct acoustically lined. The test liners were designed with the aid of previously established duct acoustic theory and a semi-empirical impedance model of the liner system. Over the limited range tested, the liner behaved primarily as predicted, exhibiting significant changes in resistance and reactance, thus providing the necessary concept validation.

Dean, P. D.↗

Improving Satellite Compatible Microdevices to Study Biology in Space

The technology for biology in space lags far behind the gold standard for biological experiments on Earth. To remedy this disparity, the Rothschild lab works on proof of concept, prototyping, and developing of new sensors and devices to further the capabilities of biology research on satellites. One such device is the PowerCell Payload System. One goal for synthetic biology in aiding space travel and colonization is to genetically engineer living cells to produce biochemicals in space. However, such farming in space presupposes bacteria retain their functionality post-launch, bombarded by radiation, and without the 1G of Earth. Our questions is, does a co-culture of cyanobacteria and protein-synthesizing bacteria produce Earth-like yields of target proteins? Is the yield sensitive to variable gravitational forces? To answer these questions, a PowerCell Payload System will spend 1 year aboard the German Aerospace Center's Euglena and Combined Regenerative Organic-food Production In Space (Eu:CROPIS) mission satellite. The PowerCell system is a pair of two 48-well microfluidic cards, each well seeded with bacteria. The system integrates fluidic, thermal, optical, electronic, and control systems to germinate bacteria spores, then measure the protein synthesized for comparison to parallel experiments conducted on the Earth. In developing the PowerCell Payload, we gained insight into the shortcomings of biology experiments on satellites. To address these issues, we have started three new prototyping projects: 1) The development of an extremely stable and radiation resistant cell-free system, allowing for the construction of proteins utilizing only cell components instead of living cells. This can be lyophilized on a substrate, like paper. (2) Using paper as a microfluidic platform that is flexible, stable, cheap, and wicking. The capillary action eliminates the need for pumps, reducing volume, mass, and potential failing points. Electrodes can be printed on the paper to sense for biochemicals. (3) Developing a modular, semi-autonomous microfluidic device that can be easily adapted for a variety of common biological experiments. This versatility will allow for quicker and cheaper experimentation. These improvements to satellite experiment platforms have the potential to radically increase the return from NASA's biological and field studies with reduced development time, mass, and cost with increased robustness data and interpretation.

biology in spac↗

Cross-field and parallel dynamics of SOL filaments in TCV

Using recently installed scrape-off layer diagnostics on the tokamak à configuration variable, we characterise the poloidal and parallel properties of turbulent filaments. We access both attached and detached divertor conditions across a wide range of core densities (f G ϵ [0.09, 0.66]) in diverted L-mode plasma configurations. With a gas puff imaging (GPI) diagnostic at the outer midplane we observed filaments with a monotonic increase in radial velocity (from 390 m s –1 to 800 m s –1 ) and cross-field radii (from 8.5 mm to 13.4 mm) with increasing core density. Interpreting the filament behaviour in the context of the two-region model, we find that they populate the ideal-interchange regime (C i ) in discharges at very low densities, and the resistive X (RX)-point regime for all other discharges. The scaling of filament velocity versus size shows good agreement with this interpretation. These results are discussed and compared with previous probe-based measurements for similar conditions, which mostly placed filaments in TCV in the resistive ballooning (RB) regime. In addition, for the first time in TCV, the parallel filament extension is studied by magnetically aligning the GPI measurements at the outboard midplane with a reciprocating probe in the divertor. In agreement with the filaments being in the ideal-interchange and the RX-point regimes, they are found to extend beyond the X-point into the outer divertor leg.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative oceanography of coastal lagoons

The hypothesis that physical lagoon characteristics and variability depend on the channel connecting the lagoon to the adjacent coastal ocean is evaluated. The geographical, hydrological, and oceanographic characteristics of 10 lagoon systems are described and analyzed; these oceanographic features are utilized to classify the lagoon systems. Choked lagoons (Laguna Joyuda, Coorong, Lake St.Lucia, Gippsland Lakes, Lake Songkla/Thale Luang/Thale Noi, and Lagoa dos Patos) are prevalent on coasts with high wave energy and low tidal range; restricted lagoons (Lake Pontchartrain and Laguna de Terminos) are located on low/medium wave energy coasts with a low tidal range; and leaky lagoons (Mississippi Sound and Belize Lagoon/Chetumal Bay) are connected to the ocean by wide tidal passes that transmit oceanic effects into the lagoon with a minimum of resistance. The data support the hypothesis that the nature of the connecting channel controls system functions.

Kjerfve, Bjorn↗

Intra-Specific Variability in Plant Hydraulic Parameters Inferred From Model Inversion of Sap Flux Data

Understanding plant hydraulic regulation is critical for predicting plant and ecosystem responses to projected increases in drought stress. Plant hydraulic regulation is controlled by observable, diverse plant hydraulic traits that can vary as much across individuals of the same species as they do across different species. Direct measurements of plant hydraulic traits from a range of ecosystems remain limited in comparison to other, more readily measured traits (e.g., specific leaf area). Furthermore, plant hydraulic trait measurements, often made at leaf or branch levels, are not easily scaled to whole-plant values that are typically used to predict plant and ecosystem fluxes. In this study, multiple whole-plant hydraulic parameters are inferred from observations of plant water use (i.e., sap flow), soil properties, and meteorological data. We use a Markov Chain Monte Carlo model inversion approach to obtain the best estimates and uncertainty of plant hydraulic parameters that capture whole-plant effective embolism resistance and stomatal sensitivity to decreasing plant water potential. We then use the inferred values in the model to estimate whole-tree water use and isohydricity. This approach reliably infers whole-plant parameter values with enough specificity to resolve inter- and intra-specific differences, and thus supplements time- and labor-intensive direct measurements of traits.

54 ENVIRONMENTAL SCIENCES↗

Reliability-Based Life Assessment of Stirling Convertor Heater Head

Onboard radioisotope power systems being developed and planned for NASA's deep-space missions require reliable design lifetimes of up to 14 yr. The structurally critical heater head of the high-efficiency Stirling power convertor has undergone extensive computational analysis of operating temperatures, stresses, and creep resistance of the thin-walled Inconel 718 bill of material. A preliminary assessment of the effect of uncertainties in the material behavior was also performed. Creep failure resistance of the thin-walled heater head could show variation due to small deviations in the manufactured thickness and in uncertainties in operating temperature and pressure. Durability prediction and reliability of the heater head are affected by these deviations from nominal design conditions. Therefore, it is important to include the effects of these uncertainties in predicting the probability of survival of the heater head under mission loads. Furthermore, it may be possible for the heater head to experience rare incidences of small temperature excursions of short duration. These rare incidences would affect the creep strain rate and, therefore, the life. This paper addresses the effects of such rare incidences on the reliability. In addition, the sensitivities of variables affecting the reliability are quantified, and guidelines developed to improve the reliability are outlined. Heater head reliability is being quantified with data from NASA Glenn Research Center's accelerated benchmark testing program.

Shah, Ashwin R.↗

Inducing optimally directed non-routine designs

Non-routine designs are characterized by the creation of new variables and thus an expansion of the design space. These differ from routine designs in that the latter are restricted to a fixed set of variables and thus a pre-defined design space. In previous papers, the 1stPRINCE non-routine design methodology that expands the design space in such a way that optimal trends dictate the direction and form of this expansion is described. How inductive techniques can determine these optimal trends are examined. The induction techniques in 1stPRINCE utilize constraint information from monotonicity analysis to determine how to mutate the design space. The process observes the constraint information of mutated designs and induces trends from those constraints. Application of 1stPRINCE to a beam under flexural load leads to an optimally directed tapered beam. An interesting application of 1stPRINCE to determine the optimally directed shape of a spinning square block such that resistance to spinning is minimized leads to the discovery of a circular wheel.

Cagan, Jonathan↗

Modeling land surface processes over a mountainous rainforest in Costa Rica using CLM4.5 and CLM5

This study compares the performance of the Community Land Models (CLM4.5 and CLM5) against tower and ground measurements from a tropical montane rainforest in Costa Rica. The study site receives over 4000 mm of mean annual precipitation and has high daily levels of relative humidity. The measurement tower is equipped with eddy-covariance and vertical profile systems able to measure various micrometeorological variables, particularly in wet and complex terrain. In this work, results from point-scale simulations for both CLM4.5 and its updated version (CLM5) are compared to observed canopy flux and micrometeorological data. Both models failed to capture the effects of frequent rainfall events and mountainous topography on the variables of interest (temperatures, leaf wetness, and fluxes). Overall, CLM5 alleviates some errors in CLM4.5, but CLM5 still cannot precisely simulate a number of canopy processes for this forest. Soil, air, and canopy temperatures, as well as leaf wetness, remain too sensitive to incoming solar radiation rates despite updates to the model. As a result, daytime vapor flux and carbon flux are overestimated, and modeled temperature differences between day and night are higher than those observed. Slope effects appear in the measured average diurnal variations of surface albedo and carbon flux, but CLM5 cannot simulate these features. This study suggests that both CLMs still require further improvements concerning energy partitioning processes, such as leaf wetness process, photosynthesis model, and aerodynamic resistance model for wet and mountainous regions.

58 GEOSCIENCES↗

Gas Jets

A brief summary of the contents of this paper is presented here. In part I the differential equations of the problem of a gas flow in two dimensions is derived and the particular integrals by which the problem on jets is solved are given. Use is made of the same independent variables as Molenbroek used, but it is found to be more suitable to consider other functions. The stream function and velocity potential corresponding to the problem are given in the form of series. The investigation on the convergence of these series in connection with certain properties of the functions entering them forms the subject of part II. In part III the problem of the outflow of a gas from an infinite vessel with plane walls is solved. In part IV the impact of a gas jet on a plate is considered and the limiting case where the jet expands to infinity changing into a gas flow is taken up in more detail. This also solved the equivalent problem of the resistance of a gaseous medium to the motion of a plate. Finally, in part V, an approximate method is presented that permits a simpler solution of the problem of jet flows in the case where the velocities of the gas (velocities of the particles in the gas) are not very large.

Chaplygin, S.↗

Growth hormone/IGF-I and/or resistive exercise maintains myonuclear number in hindlimb unweighted muscles

In the present study of rats, we examined the role, during 2 wk of hindlimb suspension, of growth hormone/insulin-like growth factor I (GH/IGF-I) administration and/or brief bouts of resistance exercise in ameliorating the loss of myonuclei in fibers of the soleus muscle that express type I myosin heavy chain. Hindlimb suspension resulted in a significant decrease in mean soleus wet weight that was attenuated either by exercise alone or by exercise plus GH/IGF-I treatment but was not attenuated by hormonal treatment alone. Both mean myonuclear number and mean fiber cross-sectional area (CSA) of fibers expressing type I myosin heavy chain decreased after 2 wk of suspension compared with control (134 vs. 162 myonuclei/mm and 917 vs. 2,076 micron2, respectively). Neither GH/IGF-I treatment nor exercise alone affected myonuclear number or fiber CSA, but the combination of exercise and growth-factor treatment attenuated the decrease in both variables. A significant correlation was found between mean myonuclear number and mean CSA across all groups. Thus GH/IGF-I administration and brief bouts of muscle loading had an interactive effect in attenuating the loss of myonuclei induced by chronic unloading.

NASA Center ARC↗

Effect of Random Thermal Spikes on Stirling Convertor Heater Head Reliability

Onboard radioisotope power systems being developed to support future NASA exploration missions require reliable design lifetimes of up to 14 yr and beyond. The structurally critical heater head of the high-efficiency developmental Stirling power convertor has undergone extensive computational analysis of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Additionally, assessment of the effect of uncertainties in the creep behavior of the thin-walled heater head, the variation in the manufactured thickness, variation in control temperature, and variation in pressure on the durability and reliability were performed. However, it is possible for the heater head to experience rare incidences of random temperature spikes (excursions) of short duration. These incidences could occur randomly with random magnitude and duration during the desired mission life. These rare incidences could affect the creep strain rate and therefore the life. The paper accounts for these uncertainties and includes the effect of such rare incidences, random in nature, on the reliability. The sensitivities of variables affecting the reliability are quantified and guidelines developed to improve the reliability are outlined. Furthermore, the quantified reliability is being verified with test data from the accelerated benchmark tests being conducted at the NASA Glenn Research Center.

Shah, Ashwin R.↗

Effect of Random Thermal Spikes on Stirling Convertor Heater Head Reliability

Onboard radioisotope power systems being developed to support future NASA exploration missions require reliable design lifetimes of up to 14 yr and beyond. The structurally critical heater head of the high-efficiency developmental Stirling power converter has undergone extensive computational analysis of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Additionally assessment of the effect of uncertainties in the creep behavior of the thin-walled heater head, the variation in the manufactured thickness, variation in control temperature, and variation in pressure on the durability and reliability were performed. However, it is possible for the heater head to experience rare incidences of random temperature spikes (excursions) of short duration. These incidences could occur randomly with random magnitude and duration during the desired mission life. These rare incidences could affect the creep strain rate and therefore the life. The paper accounts for these uncertainties and includes the effect of such rare incidences, random in nature, on the reliability. The sensitivities of variables affecting the reliability are quantified and guidelines developed to improve the reliability are outlined. Furthermore, the quantified reliability is being verified with test data from the accelerated benchmark tests being conducted at the NASA Glenn Research Center.

Shah, Ashwin R.↗

Design and Performance Evaluation of a Resistive Control Using a Hydraulic PTO System for the TALOS Wave Energy Converter

This study is focused on developing a numerical model to evaluate the performance of a hydraulic PTO system for the TALOS Wave Energy Converter. The WEC device is described and the architecture of the hydraulic PTO system is presented with detail. The WEC is modeled using WEC-Sim, and the PTO is modeled using the Simscape Fluids library from Simulink. The hydraulic PTO is based on a constant pressure configuration that is suitable for WEC passive control. The hydraulic system is composed by a set of rectifying valves and two hydraulic accumulators that reduce the stiffness of the system and also serve as energy storage devices. One of the advantages of this hydraulic PTO architecture is the possibility of controlling the electric generator to operate around the optimal efficiency operating point. The main components of the hydraulic PTO are off-the-shelf devices that are commercially available, which will facility a future deployment of the designed system. The design variables used for this study are the accumulator size, the maximum pressure in the accumulators, the hydraulic motor maximum displacement, and the shaft speed in the electric generator. The performance of the system is evaluated individually, using sinusoidal inputs that replicates regular wave conditions. In addition to this, the numerical model of the PTO is coupled to a WEC-Sim simulation of the TALOS Wave Energy Converter with six PTOs to generate a wave-to-wire model. The main objective of this work is to present a comprehensive design methodology that could serve as a guideline for future research efforts focused on implementing control algorithms on multi degree of freedom WECs.

hydraulic systems↗

Test Report - Fault Current Through Graphite Filament Reinforced Plastic

Tests were performed to determine the damage to samples of composite material when a current carrying wire is shorted to the surface of the composite material, and to determine whether enough current can flow through the material to blow a fuse before damage can occur. Fault current tests were performed on samples of graphite epoxy materials. Samples consisted of six layers of IM7 graphite fiber mat in Hercules 8552 epoxy resin. A variable power supply provided up to 35 amps of current. The high voltage side of the power supply was attached to a wire at the end of a hinged arm, and the low side was attached to the edge of the sample. To test joints, the return was connected to the edge of one sample, and the high side was shorted to the top of the other sample. Tests show that when current exceeds approximately 5 amps, the graphite glows, and the epoxy melts out at the shorted contact. At higher current levels the epoxy burns. At voltages above 15 volts the epoxy outer coat is easily broken, and fire, flame, and a rise in current occur suddenly. When joints are introduced, resistance is increased, and the maximum current resulting from a short circuit to the graphite epoxy is reduced. This condition can easily result in fault current lower than the circuit breaker limit and higher than the 5 amp ignition level. The shorting contact and the joint become hot spots with melting epoxy, smoke, and fire.

Evans, R. W.↗

Scaling Individual Tree Transpiration With Thermal Cameras Reveals Interspecies Differences to Drought Vulnerability

Abstract Understanding tree transpiration variability is vital for assessing ecosystem water‐use efficiency and forest health amid climate change, yet most landscape‐level measurements do not differentiate individual trees. Using canopy temperature data from thermal cameras, we estimated the transpiration rates of individual trees at Harvard Forest and Niwot Ridge. PT‐JPL model was used to derive latent heat flux from thermal images at the canopy‐level, showing strong agreement with tower measurements ( R 2 = 0.70–0.96 at Niwot, 0.59–0.78 at Harvard at half‐hourly to monthly scales) and daily RMSE of 33.5 W/m 2 (Niwot) and 52.8 W/m 2 (Harvard). Tree‐level analysis revealed species‐specific responses to drought, with lodgepole pine exhibiting greater tolerance than Engelmann spruce at Niwot and red oak showing heightened resistance than red maple at Harvard. These findings show how ecophysiological differences between species result in varying responses to drought and demonstrate that these responses can be characterized by deriving transpiration from crown temperature measurements.

Javadian, Mostafa↗