Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Pulse-shape analysis in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 room-temperature radiation detectors

The effect of trapping of charge carriers on the shape of the charge pulses from room temperature nuclear detectors, based on a recently discovered quaternary semiconductor Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS), has been studied. Here, we present a charge-trapping model that explains the pulse shapes for its entire duration from radiation detectors containing multiple defect types. A piecewise continuous model, based on the movement of a large number of charge carriers rather than a single charge, has been proposed to explain the pulse shapes from planar room temperature nuclear detectors. An experimental method based on the model has been described to extract charge-trapping information. This model can be applied to similar semiconductor detectors with electrically active trap centers, in general, to extract information like pre-trapping drift times. Charge pulses from a CZTS planar detector, exposed to 5486 keV alpha particles emitted by a 241Am source, were acquired using a digitizer, and the pulse shapes were explained based on the proposed model. The pre-trapping drift times for electrons as well as holes in CZTS were calculated and studied as a function of operating bias voltage, and a contrast between their bias dependent behaviors was noticed, indicating the behavioral difference of electron and hole traps.

42 ENGINEERING↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light detection in the long-drift ProtoDUNE-DP liquid argon TPC

ProtoDUNE-DP is a 6 × 6 × 6m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the Neutrino Platform at CERN in 2019-2020 as a prototype of the DUNE Far Detector. DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. The light signal in these detectors is crucial to provide precise timing capabilities. In ProtoDUNE-DP, scintillation light produced by cosmic muons in the LArTPC is collected by the photomultiplier tubes (PMTs) placed up to 7 m away from the point of interaction. The scintillation light production and propagation processes are analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations on a fuzzy process: effect of diffusion on calibration and particle identification in Liquid Argon Time Projection Chambers

Ionization electron diffusion in Liquid Argon Time Projection Chambers (LArTPCs) has typically been considered at the detector design stage, but little attention has been given to its effects on calibration and particle identification. We use a GEANT4-based simulation to study how diffusion impacts these techniques, and give consideration to how this effect is simulated. We find that diffusion can cause a drift-dependent bias to both the median and Most Probable Value (MPV) of dQ/dx distributions. The bias is estimated to be ~2.5% (median) and ~5.0% (MPV) for typical maximum drift times in currently running LArTPCs before adding detector specific considerations such as electric field non-uniformities. This information indicates that these metrics should not be used for calibration without care, contrary to the conventional wisdom. The impact of diffusion on the ability of LArTPCs to separate muons and protons is small, and not expected to pose any problems in future detectors. Diffusion may however be a significant source of systematic uncertainty when separating particles of more similar masses (muons and pions, kaons and protons). Separation of such populations may be improved by implementation of a drift-time dependent particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple Coulomb scattering for muon energy reconstruction in SBND Monte Carlo simulations

The Short Baseline Near Detector (SBND) is a liquid argon time projection chamber (LArTPC) located 110 meters downstream of the Booster Neutrino Beam target at Fermilab \cite{SBN}. The LArTPC is a detector technology with unprecedented position and calorimetric resolution for precise neutrino studies. The most dominant neutrino interaction topology in SBND is charged-current quasi-elastic muon neutrino-argon interactions, where the final state consists of a muon and a proton. Here, muons often travel long distances, sometimes exiting the detector before stopping. This loss of information creates a challenge for accurate energy estimation. There have been efforts in the MicroBooNE and ICARUS collaborations to improve energy estimation using a phenomenon known as Multiple Coulomb Scattering (MCS), which describes the jagged path taken by muons through a detector due to continuous Coulomb interactions with argon atoms. Building on these efforts, my project aims to improve an MCS-based approach to estimating the energies of exiting muons in SBND.

Puig, Xilonem Angeles [Mt. Holyoke Coll.; Fermilab↗

Performance Analysis and Radiation Damage Estimation of the Stopping Target Monitor Detectors in Mu2e

The Mu2e experiment aims to search for the charged lepton flavour violating (CLFV) process of a coherent, neutrinoless, conversion of a muon into an electron within the proximity of an aluminium nucleus. Mu2e seeks to measure the ratio (R μe ) of the rate of this conversion process, relative to that of ordinary muon capture. Mu2e will achieve world-leading sensitivity, improving the current limit of Rμe < 7 ×10 -13 (90% C.L.),set by the SINDRUM-II experiment, by an order of 104. This corresponds to a single-event sensitivity of Rμe < 2.87 × 10 -17 (90% C.L.). Many beyond Standard Model (BSM) theories require CLFV to occur at a rate accessible by Mu2e. Any observation of CLFV at Mu2e would have profound implications on particle physics. The Stopping Target Monitor (STM) will be comprised of both a HPGe and a LaBr3 detector which will monitor the signals of photons produced in stopped-muon processes to a required accuracy of 10%. To achieve the desired sensitivity, it is imperative that the detectors perform at their optimal level. The STM detectors are placed within a harsh radiation environment in the form of a high energy ‘flash’ of gamma radiation as well as a flux of fast neutrons. Estimations of radiation damage to HPGe in literature is limited. This thesis reports an approach which utilizes the Kinetic-Energy Released in Matter (KERMA) parameter that considers the energy dependence of the incident flux and the cross-section information for the incident particle. Resampling schemes have been adopted to give a realistic rate over the experiment run time. The results have then been normalized to the radiation damage caused by a 252 Cf source. The estimated time before annealing of the detector is necessary is found to be 75 and 78 months in the case of neutron damage and τ ~ 24 years, 11 months in the case of electron/positron induced damage. This shows significant improvement on the previous estimations.

36 MATERIALS SCIENCE↗

Expansion of the Fast Neutron Hodoscope at TREAT to Support Fuel Safety Experiments

In 2024 the Fuel Motion Monitoring System (FMMS), or Hodoscope, at the Transient Reactor Test Facility, is being expanded from 96 viewing channels to 192 viewing channels, effectively doubling the FMMS field of view. Here, this increase in capability will allow the FMMS to support larger scale fuel tests, encompassing height-of-core test devices, test devices with multi-pin fuel assemblies, and test devices with recirculating coolant flow. Work supporting the expansion included refurbishing 96 additional proton recoil scintillator (PRS) detectors, doubling the data acquisition system (DAS) installed architecture, improving time synchronization in the DAS, and new research to measure the PRS detector energy-dependent, fast-neutron detection efficiency. In addition, laboratory activities have produced an improved benchtop testing capability for assessing the DAS, time synchronization, and external start triggering, along with an updated capability to scan PRS detectors to develop a preliminary flat-field normalization prior to deployment to TREAT.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Toward the implementation of self-powered, wireless, real-time reactor power sensing

The successful development of real-time, self-powered, wireless reactor power sensing technology would enable key operating parameters of every fuel assembly in a commercial reactor core to be continuously monitored, and potentially be utilized for applications such as closed-loop reactor control. This paper discusses the expansion of successful work on the application of Self Powered Neutron Detectors (SPND) for reactor power monitoring and the wireless transmission of these detector signals using advanced vacuum micro-electronic (VME) transmitter technology developed by Westinghouse in collaboration with the Penn State University Radiation Science and Engineering Center. Results demonstrate that this technology may be successfully applied via long-term testing in the Penn State TRIGA reactor. SPND are inherently slower than, for example, ion chambers due to their dependence on radioactive decay to generate a signal. Additional research developed delay compensation algorithms to accelerate the response of these detectors for use in near-real-time closed-loop reactor control. Initial results indicate that practical signal acceleration can be obtained digitally or with an equivalent analog circuit. Future research will apply an inverse model of the sensor’s balance differential equations to more-effectively accelerate the SPND signal. Use of inverse models will also prove to be adaptive in the sense that time-dependent burn-up of these detectors, due to neutron activation of the detector material, can be modeled and applied in the acceleration algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber

Finding unequivocal evidence of dark matter interactions in a particle detector is a major goal of research in physics. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nuclei down to the so-called neutrino floor, in a mass range from a few GeV to hundreds of TeV. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all types of events observed in the detector, is essential for the optimal design of the new experiment. In this article, we report on a specific set of events, namely, standard two-pulse scintillation–ionization signals with a third small amplitude pulse, occurring within the 440 μ s data acquisition window of standard events. Some of these events are due to the photoionization of the TPC cathode. We compare our results with those published by collaborations using liquid xenon time projection chambers, which observed a similar phenomenon, and, in particular, with a recent paper by the LUX Collaboration (D.S. Akerib et al. Phys.Rev.D 102, 092004 (2020)) From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths of around 128 nm, in liquid argon. Also, both experiments observe events likely related to the photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be an order of magnitude lower in DarkSide-50 than in LUX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unsupervised learning for identifying events in active target experiments

This article presents novel applications of unsupervised machine learning methods to the problem of event separation in an active target detector, the Active-Target Time Projection Chamber (AT-TPC). The overarching goal is to group similar events in the early stages of the data analysis, thereby improving efficiency by limiting the computationally expensive processing of unnecessary events. The application of unsupervised clustering algorithms to the analysis of two-dimensional projections of particle tracks from a resonant proton scattering experiment on 46 Ar is introduced. We explore the performance of autoencoder neural networks and a pre-trained VGG16 Simonyan and Zisserman (2015) convolutional neural network. We study clustering performance on both data from a simulated 46 Ar experiment, and real events from the AT-TPC detector. We find that a -means algorithm applied to simulated data in the VGG16 latent space forms almost perfect clusters. Additionally, the VGG16+-means approach finds high purity clusters of proton events for real experimental data. Here, we also explore the application of clustering the latent space of autoencoder neural networks for event separation. While these networks show strong performance, they suffer from high variability in their results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and installation of wavelength-shifting reflective light enhancers for the Short-Baseline Near Detector

We report on the design, production, and installation of a wavelength-shifting reflective system on the cathode of the Short-Baseline Near Detector (SBND), a liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam. To increase and homogenize scintillation-light collection, 64 double-sided plates were fabricated from FR4, laminated with specular reflector film and coated with 300 $μ$g/cm$^2$ of tetraphenyl butadiene (TPB) wavelength shifter using controlled physical vapor deposition. The coating uniformity was validated through dedicated measurements of deposited mass and profilometry studies. Because exposure to ambient blue/UV light could degrade the TPB, protective filtering and controlled storage conditions were implemented during handling and installation. The coated plates were assembled between conductive meshes for high-voltage compatibility and installed in situ during detector integration. This system constitutes the largest TPB-coated area deployed in a neutrino detector. It operates in conjunction with SBND's photon detection system, which consists of photomultiplier tubes and X-ARAPUCAs. Early light-collection measurements show high uniformity and light response across the detector, supporting improved triggering, calorimetry, and position reconstruction in SBND.

Acciarri, R. [Fermilab]↗

Enhancing spectroscopy and microscopy with emerging methods in photon correlation and quantum illumination

Quantum optics has led to important advancements in our ability to prepare and detect correlations between individual photons. Its principles are increasingly translated into nanoscale characterization tools, furthering methods in spectroscopy, microscopy and metrology. Here, in this Review, we discuss the rapid progress in this field driven by advanced technologies of single-photon detectors and quantum-light sources, including time-resolved single-photon counting cameras, superconducting nanowire single-photon detectors and entangled photon sources of increasing brightness. We emphasize emerging applications in super-resolution microscopy, measurements below classical noise limits and photon-number-resolved spectroscopy—a powerful paradigm for the characterization of nanoscale electronic materials. We conclude by discussing key technological challenges and future opportunities in materials science and bionanophotonics alike.

Tsao, Chieh [University of California, Berkeley, C↗

A Low-Power Time-to-Digital Converter for the CMS Endcap Timing Layer (ETL) Upgrade

We present the design and test results of a Time-to-Digital-Converter (TDC). The TDC will be a part of the readout ASIC, called ETROC, to read out Low-Gain Avalanche Detectors (LGADs) for the CMS Endcap Timing Layer (ETL) of High-Luminosity LHC upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 W for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the Time of Arrival (TOA) and the Time over Threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65 nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 ps and 9.9 ps with and without the nonlinearity correction, respectively. The TDC block consumes 97 W at the hit occupancy of 1%. Over a temperature range from 23 C to 78 C and a power supply voltage range from 1.05 V to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation-tolerance specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fault-tolerant grid frequency measurement algorithm during transients

A system determines the frequency of grid signals corresponding to an electrical grid in real time. The system includes a transient detector that monitors a grid signal from a voltage meter or a current meter connected to the electrical grid. The system produces, in real time and at a sampling rate, a deviation signal indicative of a periodicity of the monitored grid signal. The system determines, over one or more cycles of the monitored grid signal, a measurement signal corresponding to the deviation signal. The system determines a frequency signal that corresponds a frequency estimation of the monitored signal by applying a frequency estimation when values of the measurement signal are less than a deviation threshold and maintaining the frequency signal at a constant value when values of the measured signal equal or exceeds the deviation threshold.

Zhan, Lingwei↗

Optical potential uncertainties on exclusive tens-of-MeV Ar cross sections

Large liquid argon time projection chamber (LArTPC) neutrino detectors, such as those planned for the Deep Underground Neutrino Experiment (DUNE), show considerable promise as a platform for next-generation measurements of supernova neutrinos. Thanks to the neutron excess in $^{40}$Ar as well as the detailed tracking possible with LArTPCs, these detectors are expected to be uniquely capable of measuring supernova electron neutrinos with high statistics and minimal backgrounds. However, these technological advantages come at the price of complexities in data interpretation; reconstruction of the incident energies of supernova neutrinos in a future LArTPC-based analysis will be subject to a variety of systematic uncertainties related to nuclear interaction modeling. In this talk, we present a study of a subset of these uncertainties as implemented in the MARLEY event generator used by DUNE and other LArTPC neutrino experiments. Variations to the optical potential used in the MARLEY nuclear de-excitation model are applied to the calculation of exclusive tens-of-MeV neutrino-nucleus cross sections for the first time, and the impact on observables of interest for supernova neutrino detection is examined. We also discuss prospects for quantifying other sources of uncertainty on the MARLEY neutrino interaction model.

El-Haj, Luca Abu↗

A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures

Abstract. Due to its complexity, gas- and particle-phase organic carbon in the atmosphere is often classified by its bulk physicochemical properties. However, there is a dearth of robust, moderate-cost approaches to measure the bulk chemical composition of organic carbon in the atmosphere. This is particularly true for the degree of oxygenation, which critically affects the properties and impacts of organic carbon but for which routine measurement approaches are lacking. This gap has limited the understanding of a wide range of atmospheric components, including particulate matter, the mass of which is monitored worldwide due to its health and environmental effects but the chemical characterization of which requires relatively high capital costs and complex operation by highly trained technical personnel. In this work, we demonstrate a new approach to estimate the mass of carbon and oxygen in analytes and mixtures that relies only on robust, moderate-cost detectors designed for use with gas chromatography. Organic compounds entering a flame ionization detector were found to be converted with approximately complete efficiency to CO2, which was analyzed downstream using an infrared detector to measure the mass of carbon analyzed. The ratio of the flame ionization detector (FID) signal generated to CO2 formed (FID∕CO2) was shown to be strongly correlated (R2=0.89) to the oxygen-to-carbon ratio (O∕C) of the analyte. Furthermore, simple mixtures of analytes behaved as the weighted average of their components, indicating that this correlation extends to mixtures. These properties were also observed to correlate well with the sensitivity of the FID estimated by structure activity relationships (quantified as the relative effective carbon number). The relationships between measured FID∕CO2, analyte O∕C, and FID sensitivity allow the estimation of one property from another with <15 % error for mixtures and <20 % error for most individual analytes. The approach opens the possibility of field-deployable, autonomous measurement of the carbon and oxygen content of particulate matter using time-tested, low-maintenance detectors, though such an application would require some additional testing on complex mixtures. With some instrumental modifications, similar measurements on gas-phase species may be feasible. Moreover, the potential expansion to additional gas chromatography detectors may provide concurrent measurement of other elements (e.g., sulfur, nitrogen).

42 ENGINEERING↗