Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

The Deep Underground Neutrino Experiment (DUNE) Program

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment aimed at determining the neutrino mass hierarchy and the CP-violating phase. The DUNE physics program also includes the detection of astrophysical neutrinos and the search for signatures beyond the Standard Model, such as nucleon decays. DUNE consists of a near detector complex located at Fermilab and four 17 kton Liquid Argon Time Projection Chamber (LArTPC) far detector modules to be built 1.5 km underground at SURF, approximately 1300 km away. The detectors are exposed to a wideband neutrino beam generated by a 1.2 MW proton beam with a planned upgrade to $>$ 2 MW. Two 770 ton LArTPCs (ProtoDUNEs) have been operated at CERN for over 2 years as a testbed for DUNE far detectors and have been optimized to take new cosmic and test-beam data in 2024-2025. The DUNE and ProtoDUNE experiments and physics goals, as well as recent progress and results, are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particulate and aerosol detector

Particulate detector which monitors emissions from solid propellant fuels can monitor air quality. High signal-to-noise ratio detector can count aerosols and particles efficiently. Detector can distinguish one particle from another with respect to both time and energy of impact. Detector consists of accelerator, capacitor sensor, and readout recording equipment.

Kinard, W. H.↗

Search for supermassive magnetic monopoles using mica crystals

The survival of the Galactic magnetic field almost certainly sets an astrophysical upper bound of approx. 10 to the minus 15th power cm(-2) sr(-1) s(-1) on the flux of monopoles. To improve significantly upon this Parker limit with direct, real time searches would require a detector area of approx. 10,000 square meters and a collection time of years. Several such searches are being contemplated. A novel alternative scheme using large mica crystals capable of recording and storing tracks of slow monopoles over a time scale of approx. 10 to the 9th power years was proposed.

Price, P. B.↗

Expanding the physics reach of DUNE in the near and far detectors

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment. Its primary goal is the determination of the neutrino mass hierarchy and the CP-violating phase. The DUNE physics programme also includes the detection of astrophysical neutrinos and the search for beyond the Standard Model (BSM) phenomena. DUNE will consist of a near detector (ND) complex placed at Fermilab, and a modular Liquid Argon Time Projection Chamber (LArTPC) far detector (FD) to be built in the Sanford Underground Research Facility (SURF), approximately 1300 km away from the neutrino production point. This thesis describes three different projects within DUNE. First, a novel strategy to improve the triggering capabilities of the DUNE FD is proposed. It uses matched filters to enhance the production of online hits across all charge collection planes. Next, the possibility of detecting neutrinos coming from dark matter (DM) annihilations in the Sun with the FD is explored. The complementarity of DUNE to this kind of DM searches is shown. Finally, the simulation and reconstruction framework of ND-GAr, the gas argon ND proposed for Phase II of DUNE, is presented. A number of additions to this are described, particularly focused on the development of the particle identification (PID) capabilities of the detector. These are then used to perform the first event selection studies with an end-to-end simulation in ND-GAr, in particular the selection of pion exclusive samples in $\nu_{\mu}$ CC interactions. All three of these projects share the common goal of enhancing the physics programme of DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of the cosmic sources of hard X-rays

An actively-shielded, high-energy X-ray telescope was launched onboard OSO-8 on 21 June 1975. The primary objectives of this experiment are the measurements of the energy spectrum of discrete cosmic X-ray sources in the range 20 keV to 3 MeV and of the temporal variations in the intensity of each source detected with a time resolution of 0.3 msec. This detector provides the highest duty factor and the finest time resolution of any of its kind for observations over a period of up to 10 days. The background spectrum of this detector in orbit was monitored continuously since shortly after launch. The minimum detectable source strength is estimated to be between 10,000 and 100,000 photons/sq-cm-sec keV, limited primary by the effects of induced radioactivity. From 16 July through 18 July 1975, the X-ray binary, Cen X-3, was observed with the hard X-ray telescope.

Dennis, B. R.↗

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thin film charged particle detectors

Silicon tracking detectors have grown to cover larger surface areas up to hundreds of square meters, and are even taking over other sub-detectors, such as calorimeters. However, further improvements in tracking detector performance are more likely to arise from the ability to make a low mass detector comprised of a high ratio of active sensor to inactive materials, where dead materials include electrical services, cooling, mechanical supports, etc. In addition, the cost and time to build these detectors is currently large. Therefore, advancements in the fundamental technology of tracking detectors may need to look at a more transformative approach that enables extremely large area coverage with minimal dead material and is easier and faster to build. The advancement of thin film fabrication techniques has the potential to revolutionize the next-to-next generation of particle detector experiments. Some thin film deposition techniques have already been developed and widely used in the industry to make LED screens for TVs and monitors. If large area thin film detectors on the order of several square meters can be fabricated with similar performance as current silicon technologies, they could be used in future particle physics experiments. This paper aims to review the key fundamental performance criteria of existing silicon detectors and past research to use thin films and other semi-conductor materials as particle detectors in order to explore the important considerations and challenges to pursue thin film detectors.

Solid state detectors↗

Searching for Exotic Signals with the NOvA Experiment

Two highly segmented NOvA scintillation detectors, separated by 810 km and located in the pathof the NuMI neutrino beam produced at Fermilab, are optimized to study the neutrino oscillationphenomenon. At the same time, the larger Far Detector with 4,000 m2 surface area is capable to search for the low-mass magnetic monopoles, and to monitor the flux of the high-multiplicitycosmic ray showers. The smaller Near Detector, located 100 m underground at Fermilab, is ableto search for the presence of possible elusive Dark Matter particles in the high-intensity NuMIneutrino beam, and to study the seasonal variations of multi-muon cosmic flux component. BothNOvA detectors serve in combination as a powerful supernova neutrino detector, and allow forthe multi-messenger signal searches in coincidence with LIGO/Virgo gravitational wave events.A survey of the most recent NOvA results on these topics is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal response of large area high temperature superconducting YBaCuO infrared bolometer

Thermal analysis of large area high temperature superconducting infrared detector operating in the equilibrium mode (bolometer) was performed. An expression for the temperature coefficient beta=1/R(dR/dT) in terms of the thermal conductance and the thermal time constant of the detector were derived. A superconducting transition edge bolometer is a thermistor consisting of a thin film superconducting YBaCuO evaporated into a suitable thermally isolated substrate. The operating temperature of the bolometer is maintained close to the midpoint of the superconducting transition region where the resistance R has a maximum dynamic range. A detector with a strip configuration was analyzed and an expression for the temperature rise (delta T) above the ambient due to a uniform illumination with a source of power density P(sub i) was calculated. An expression for the thermal responsivity of the detector was derived using the thermal diffusion analysis with appropriate boundary conditions. It was found that the thermal responsibility depends upon the spatial modulation frequency and the angular frequency of the incoming radiation. The problem of the thermal cross talk between different detector elements was addressed. In the case of monolithic HTS detector array with a row of square elements of dimensions 2a and CCD or CID readout electronics the thermal spread function was derived for different spacing between elements. This analysis can be critical for future design and applications of large area focal plane arrays as broad band optical detectors made of granular thin films HTS YBaCuO.

Khalil, Ali E.↗

Thermal response of large area high temperature superconducting YBaCuO infrared bolometers

Thermal analysis of large area high temperature superconducting infrared detector operating in the equilibrium mode (bolometer) was performed. An expression for the temperature coefficient beta = 1/R(dR/dT) in terms of the thermal conductance and the thermal time constant of the detector were derived. A superconducting transition edge bolometer is a thermistor consisting of a thin film superconducting YBaCuO evaporated into a suitable thermally isolated substrate. The operating temperature of the bolometer is maintained close to the midpoint of the superconducting transition region where the resistance R has a maximum dynamic range. A detector with a strip configuration was analyzed and an expression for the temperature rise (delta T) above the ambient due to a uniform illumination with a source of power density was calculated. An expression for the thermal responsibility depends upon the spatial modulation frequency and the angular frequency of the incoming radiation. The problem of the thermal cross talk between different detector elements was addressed. In the case of monolithic HTS detector array with a row of square elements of dimensions 2a and CCD or CID readout electronics the thermal spread function was derived for different spacing between elements.

Khalil, Ali E.↗

Integrator Circuitry for Single Channel Radiation Detector

Input circuitry is provided for a high voltage operated radiation detector to receive pulses from the detector having a rise time in the range of from about one nanosecond to about ten nanoseconds. An integrator circuit, which utilizes current feedback, receives the incoming charge from the radiation detector and creates voltage by integrating across a small capacitor. The integrator utilizes an amplifier which closely follows the voltage across the capacitor to produce an integrator output pulse with a peak value which may be used to determine the energy which produced the pulse. The pulse width of the output is stretched to approximately 50 to 300 nanoseconds for use by subsequent circuits which may then use amplifiers with lower slew rates.

Holland, Samuel D.↗

Studies of BONuS12 Radial GEM Detector and TCS Beam Spin Asymmetry in CLAS12

The Barely Offshell Nucleon Structure (BONuS12) experiment adopted the concept of spectator tagging technique to study the nearly-free neutron structure function Fn2 in the CLAS12 of Jefferson Lab. A novel Radial Time Projection Chamber (RTPC) detector was built, tested and integrated into the CLAS12 system to detect a back-moving low momentum tagged proton in d(e,ep)X deep-inelastic scattering. It was a 40 cm long gaseous detector consisting of 3 layers of cylindrical GEM foils for the charge amplification, with the data readout directly from the surrounding padboard. The RTPC detected the recoiling spectator proton, in coincidence with the scattered electron in the CLAS12. Nucleon structure functions are directly related to the partonic functions, quarks momentum distribution in one dimension. A Generalized Parton Distribution (GPD) came to the lime-light as it encodes the information of both longitudinal momentum and transverse position of partons inside the nucleons. Factorization of hard process such as DVCS allows to access GPDs. Timelike Compton Scattering (TCS), ?p ? ??p, is another process that allows to access the GPDs. TCS is studied experimentally in the CLAS12 of Jefferson lab using the quasi-real photoproduction of time-like photon which eventually decays to lepton pair. This dissertation presents the concept of spectator tagging in BONuS12, and the research and development efforts during the BONuS12 preparation leading up to the successful data-taking during spring and summer 2020. In addition, analysis framework to extract the beam spin asymmetry of TCS events through the CLAS12 Run group A data is presented.

Poudel, Jiwan↗

Inclusive Charged-Current Electron Neutrino Interactions in SBND

The Short-Baseline Near Detector (SBND), a 112 ton liquid argon time projection chamber (LArTPC), is the near detector of the Short- Baseline Neutrino Program at Fermilab. Due to its proximity to the Booster Neutrino Beam target, SBND has already seen a record-breaking number of electron neutrino interactions on argon. We present preliminary results from SBND’s differential inclusive electron neutrino charged-current analysis from our first year of beam data, selecting over 2,000 interactions. This analysis will present the largest sample of electron neutrinos on argon to date, as well as the first differential cross section measurement of electron neutrinos. This poster will give an overview of the selection, cross-section extraction, and demonstrate SBND’s detector and electromagnetic shower reconstruction performance through data/MC comparisons.

Tung, Lynn [Chicago U.]↗

Experiment definition and integration study for the accommodation of giant, passive detector of Exotic Particles In the Cosmic Rays (EPIC) payload on shuttle/spacelab missions

The feasibility of the design, construction, launch and retrieval of a hinged 15 ft by 110 ft the platform containing an array of interleaved CR-39 and Lexan track-recording detectors to be placed into circular orbit by space shuttle is assessed. The total weight of the detector assembly plus supporting structure and accessories is 32,000 pounds. The modular construction permits as little as one fourth of the payload to be exposed at one time. The CR-39 detector has sensitivity adequate to detect and study cosmic rays ranging from minimum ionizing iron-group nuclei to the heaviest elements. The detectors will survive a one year exposure to trapped protons without losing their high resolution. Advantages include low cost, huge collecting power (approximately 150 sq m) as well as the high resolution previously attainable only with electronic detectors.

Price, P. B.↗

Reaching For New Physics With MeV-scale Reconstruction In The MicroBooNE LArTPC Neutrino Detector

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing MeV-Scale energy depositions, or blips, in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV scale using reconstructed blips in MicroBooNE LArTPC data at Fermilab. A concentration of low-energy ($<$3 MeV) blips is observed around fiberglass mechanical support struts along the TPC edges, with spectral features consistent with the Compton edge of the 2.614 MeV $^{208}$Tl decay $\gamma$ ray. With these features we perform the electron energy scale calibration to few-percent precision and yield the specific activity of $^{208}$Tl in the struts, $(11.7 \pm 0.2 \text{(stat)} \pm 2.8 \text{(syst)})$ Bq/kg. Using cosmogenic blips above 3 MeV, we demonstrate the ability of large LArTPCs to discriminate low-energy proton and electron depositions. An enriched low-energy proton sample selected with this technique is smaller in data than in dedicated CORSIKA simulations, pointing to possible mismodeling in CORSIKA incident cosmic fluxes or Geant4 particle transport. These methods are applied to MicroBooNE's inclusive single-photon search, which reported a 2.2$\sigma$ excess below 600 MeV in shower energy for events with no reconstructed protons. By identifying and classifying blips near single-photon events selected by the WireCell reconstruction framework, a more comprehensive labeling of nearby hadronic activity is established: blips upstream of the shower axis indicate previously unidentified final-state protons, while elevated blip counts at wide angles signal final-state neutrons. Taken together with MiniBooNE's long-standing low-energy excess (LEE) and MicroBooNE electron-like and sterile neutrino searches disfavored as possible explanations of the MiniBooNE anomaly, this analysis motivates an expanded exploration of the single-photon channel in Fermilab's short-baseline LArTPC program. This thesis documents the current status of this enhanced analysis, which will form a key part of MicroBooNE's final low-energy-excess results.

Andrade Aldana, Diego Armando [IIT, Chicago (main)↗

The DUNE Near Detector

DUNE is a next-generation experiment aiming to provide precision measurements of neutrino oscillation parameters. It will detect neutrinos produced in the Long-Baseline Neutrino Facility beamline at Fermilab, using a Near Detector situated near the beam target where the neutrinos originate and a Far Detector located 1300 km away in South Dakota. A comparison of the spectra of neutrinos measured at the Far and the Near Detector will allow for the extraction of oscillation probabilities from which the oscillation parameters can be inferred. The specific role of the Near Detector is to serve as the experiment’s control: it will establish the no oscillation null hypothesis, measure and monitor the beam, constrain systematic uncertainties, and provide essential measurements of the neutrino interactions to improve models. The Near Detector complex will include three primary detector components: a liquid argon time projection chamber, a high-pressure gas time projection chamber and an on-axis beam monitor. The three detectors will serve important individual and overlapping functions, with two of them being also able to move transverse to the beam’s axis via the DUNE-PRISM program. The overall mission of the Near Detector, as well as the three sub-detectors’ unique capabilities and physics programs will be discussed in these proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗