Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Measurements of the 239 Pu(n,f)/ 235 U(n,f) and 238 U(n,f)/ 235 U(n,f) Cross-Section Ratios Using Quasi-Monoenergetic Neutron Beams

Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EGS Collab Experiment 1: Continuous Active-Source Seismic Monitoring (CASSM) Data

The U.S. Department of Energy's Enhanced Geothermal System (EGS) Collab project aims to improve our understanding of hydraulic stimulations in crystalline rock for enhanced geothermal energy production through execution of intensely monitored meso-scale experiments. The first experiment was performed at the 4850 ft level of the Sanford Underground Research Facility (SURF), approximately 1.5 km below the surface at Lead, South Dakota. The data reported here were collected by the continuous active-source seismic monitoring (CASSM) system (Ajo-Franklin et al., 2011). This system was permanently installed in the testbed and consisted of 17 piezoelectric sources that were recorded by 2-12 channel hydrophone arrays, 18 3-C accelerometers, and 4 3-C geophones at a Nyquist frequency of 24kHz. The source array was activated in a repeated sequence of shots (each source fired 16 times and stacked into resultant waveforms) for the duration of the experiment (April 25, 2018 - March 7, 2019) with few exceptions. Please see the attached documents describing the source / receiver geometry. The data are available in both seg2 (.dat extension) and segy (.sgy extension) format. Each segy file contains multiple seg2 files.

15 GEOTHERMAL ENERGY↗

Polarized {sup 3}He{sup −} ion source with hyperfine state selection

High beam polarization is essential to the scientific productivity of a collider. Polarized {sup 3}He ions are an essential part of the nuclear physics programs at existing and future ion-ion and electron-ion colliders such as BNL's RHIC and eRHIC and JLab's ELIC. Ion sources with performance exceeding that achieved today are a key requirement for the development of these next generation high-luminosity high-polarization colliders. The development of high-intensity high-brightness arc-discharge ion sources at the Budker Institute of Nuclear Physics (BINP) has opened up an opportunity for realization of a new type of a polarized {sup 3}He{sup −} ion source. This report discusses a polarized {sup 3}He{sup −} ion source based on the large difference of extra-electron auto-detachment lifetimes of the different {sup 3}He{sup −} ion hyperfine states. The highest momentum state of 5/2 has the largest lifetime of τ ∼ 350 µs while the lower momentum states have lifetimes of τ ~ 10 µs. By producing {sup 3}He{sup −} ion beam composed of only the |5/2, ±5/2> hyperfine states and then quenching one of the states by an RF resonant field, {sup 3}He{sup −} beam polarization of 90% can be achieved. Such a method of polarized {sup 3}He{sup −} production has been considered before; however, due to low intensities of the He{sup +} ion sources existing at that time, it was not possible to produce any interesting intensity of polarized {sup 3}He{sup −} ions. The high-brightness arc-discharge ion source developed at BINP can produce a high-brightness {sup 3}He{sup +} beam with an intensity of up to 2 A allowing for selection of up to ∼1-4 mA of {sup 3}He{sup −} ions with ∼90% polarization. The high gas efficiency of an arc-discharge source is important due to the high cost of {sup 3}He gas. Some features of such a PIS as well as prototype designs are considered. An integrated {sup 3}He{sup −} ion source design providing high beam polarization could be prepared using existing BNL equipment with incorporation of new designs of the 1) arc discharge plasma generator, 2) extraction system, 3) charge exchange jet, and 4) magnetic separation system.

43 PARTICLE ACCELERATORS↗

SU-E-T-375: Evaluation of a MapCHECK2(tm) Planar 2-D Diode Array for High-Dose-Rate Brachytherapy Treatment Delivery Verifications

Purpose: Despite improvements of HDR brachytherapy delivery systems, verification of source position is still typically based on the length of the wire reeled out relative to the parked position. Yet, the majority of errors leading to medical events in HDR treatments continue to be classified as missed targets or wrong treatment sites. We investigate the feasibility of using dose maps acquired with a two-dimensional diode array to independently verify the source locations, dwell times, and dose during an HDR treatment. Methods: Custom correction factors were integrated into frame-by-frame raw counts recorded for a Varian VariSource™ HDR afterloader Ir-192 source located at various distances in air and in solid water from a MapCHECK2™ diode array. The resultant corrected counts were analyzed to determine the dwell position locations and doses delivered. The local maxima of polynomial equations fitted to the extracted dwell dose profiles provided the X and Y coordinates while the distance to the source was determined from evaluation of the full width at half maximum (FWHM). To verify the approach, the experiment was repeated as the source was moved through dwell positions at various distances along an inclined plane, mimicking a vaginal cylinder treatment. Results: Dose map analysis was utilized to provide the coordinates of the source and dose delivered over each dwell position. The accuracy in determining source dwell positions was found to be +/−1.0 mm of the preset values, and doses within +/−3% of those calculated by the BrachyVision™ treatment planning system for all measured distances. Conclusion: Frame-by-frame data furnished by a 2 -D diode array can be used to verify the dwell positions and doses delivered by the HDR source over the course of treatment. Our studies have verified that measurements provided by the MapCHECK2™ can be used as a routine QA tool for HDR treatment delivery verification.

60 APPLIED LIFE SCIENCES↗

Data Release Report for Source Physics Experiment 4Prime (SPE-4Prime) Nevada National Security Site

The fourth test in the Source Physics Experiment series (SPE-4Prime) was conducted at a granite site in Nevada on May 21, 2015, at 18:35:44.000,003,989 ± 20 nanoseconds Coordinated Universal Time. The explosive source was 69.1 kilograms (kg) (including detonator assembly) of Composition C4 plastic explosive (89.14 kg TNT equivalent) detonated at a depth of 87.2 meters (m). The explosion was recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers installed at various depths from 7 to 99 m in boreholes positioned around the source hole, and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and three-component accelerometers at distances of 100 m to 25 kilometers. Infrasound data were collected from ground-based sensor arrays at distances out to 5 kilometers.

58 GEOSCIENCES↗

On Neural Architectures for Astronomical Time-series Classification with Application to Variable Stars

Despite the utility of neural networks (NNs) for astronomical time-series classification, the proliferation of learning architectures applied to diverse data sets has thus far hampered a direct intercomparison of different approaches. Here we perform the first comprehensive study of variants of NN-based learning and inference for astronomical time series, aiming to provide the community with an overview on relative performance and, hopefully, a set of best-in-class choices for practical implementations. In both supervised and self-supervised contexts, we study the effects of different time-series-compatible layer choices, namely the dilated temporal convolutional neural network (dTCNs), long-short term memory NNs, gated recurrent units and temporal convolutional NNs (tCNNs). Additionally, we also study the efficacy and performance of encoder-decoder (i.e., autoencoder) networks compared to direct classification networks, different pathways to include auxiliary (non-time-series) metadata, and different approaches to incorporate multi-passband data (i.e., multiple time series per source). Performance—applied to a sample of 17,604 variable stars (VSs) from the MAssive Compact Halo Objects (MACHO) survey across 10 imbalanced classes—is measured in training convergence time, classification accuracy, reconstruction error, and generated latent variables. We find that networks with recurrent NNs generally outperform dTCNs and, in many scenarios, yield to similar accuracy as tCNNs. In learning time and memory requirements, convolution-based layers perform better. We conclude by discussing the advantages and limitations of deep architectures for VS classification, with a particular eye toward next-generation surveys such as the Legacy Survey of Space and Time, the Roman Space Telescope, and Zwicky Transient Facility.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon Hanbury-Brown-Twiss interferometry for noncentral heavy-ion collisions

Currently, the only known way to obtain experimental information about the space-time structure of a heavy-ion collision is through two-particle momentum correlations. Azimuthally sensitive Hanbury-Brown-Twiss (HBT) intensity interferometry can complement elliptic flow measurements by constraining the spatial deformation of the source and its time evolution. Performing these measurements on photons allows us to access the fireball evolution at earlier times than with hadrons. Using ideal hydrodynamics to model the space-time evolution of the collision fireball, we explore theoretically various aspects of two-photon intensity interferometry with transverse momenta up to 2 GeV, in particular the azimuthal angle dependence of the HBT radii in noncentral collisions. We highlight the dual nature of thermal photon emission, in both central and noncentral collisions, resulting from the superposition of QGP and hadron resonance gas photon production. This signature is present in both the thermal photon source function and the HBT radii extracted from Gaussian fits of the two-photon correlation function.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

All-sky search for long-duration gravitational wave transients in the first Advanced LIGO observing run

We present the results of a search for long-duration gravitational wave transients in the data of the LIGO Hanford and LIGO Livingston second generation detectors between $ \newcommand{\OOneStart}{{\rm 12 ~September ~2015}} \newcommand{\OOneStartShort}{{\rm September ~2015}} \OOneStartShort$ and $ \newcommand{\OOneStop}{{\rm 19~ January ~2016}} \newcommand{\OOneStopShort}{{\rm January~ 2016}} \OOneStopShort$, with a total observational time of $ \newcommand{\OOneLivetime}{{\rm 49~d}} \OOneLivetime$. The search targets gravitational wave transients of 10–500 s duration in a frequency band of 24–2048 Hz, with minimal assumptions about the signal waveform, polarization, source direction, or time of occurrence. No significant events were observed. As a result we set 90% confidence upper limits on the rate of long-duration gravitational wave transients for different types of gravitational wave signals. We also show that the search is sensitive to sources in the Galaxy emitting at least ~10 -8 $ \newcommand{\msuncd}{{\rm M_{\odot} c^2}} \newcommand{\msun}{{\rm M_{\odot}}} {\msuncd}$ in gravitational waves.

79 ASTRONOMY AND ASTROPHYSICS↗

A new MCNPX PTRAC coincidence capture file capability: a tool for neutron detector design

The existing MCNPX{trademark} PTRAC coincidence capture file allows a full list of neutron capture events to be recorded in any simulated detection medium. The originating event history number (e.g. spontaneous fission events), capture time, location and source particle number are tracked and output to file for post-processing. We have developed a new MCNPX PTRAC coincidence capture file capability to aid detector design studies. New features include the ability to track the isotopes that emitted the detected neutrons as well as induced fission chains in mixed samples before detection (both generation number and isotope). Here, the power of this tool is demonstrated using a detector design that has been developed for the non-destructive assay (NDA) of spent nuclear fuel. Individual capture time distributions have been generated for neutrons originating from Curium-244 source spontaneous fission events and induced fission events in fissile isotopes of interest: namely Plutonium-239, Plutonium-241, and Uranium-235. Through this capability, a full picture for the attribution of neutron capture events in the detector can be simulated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20keV energy range. We are building a TES-based instrument for time Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. the first, spectroscopy measurements using these arrays are promising, with a best single-pixel energy resolution of 11.2 eV and saturation energy > 20 keV. We present a series of recent X-ray Fluorescence measurements involving transition metal elements and multi-element samples with closely spaced emission lines, in particular a Cu-Ni-Co thin film and a foil of Cu and Hf, The TES-measured spectra are directly compared to spectra measured with silicon drift detectors at an APS beamline, demonstrating the improved X-ray science made possible by TES spectrometers.

Guruswamy, Tejas↗

A new NCNPX PTRAC coincidence capture file capability: a tool for neutron detector design

The existing Monte Carlo N-Particle (MCNPX) particle tracking (PTRAC) coincidence capture file allows a full list of neutron capture events to be recorded in any simulated detection medium. The originating event history number (e.g. spontaneous fission events), capture time, location and source particle number are tracked and output to file for post-processing. We have developed a new MCNPX PTRAC coincidence capture file capability to aid detector design studies. New features include the ability to track the nuclides that emitted the detected neutrons as well as induced fission chains in mixed samples before detection (both generation number and nuclide that underwent induced fission). Here, the power of this tool is demonstrated using a detector design developed for the non-destructive assay (NDA) of spent nuclear fuel. Individual capture time distributions have been generated for neutrons originating from Curium-244 source spontaneous fission events and induced fission events in fissile nuclides of interest: namely Plutonium-239, Plutonium-241, and Uranium-235. Through this capability, a full picture for the attribution of neutron capture events in the detector can be simulated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A new MCNPX PTRAC coincidence capture file capability: a tool for neutron detector design

The existing Monte Carlo N-Particle (MCNPX) particle tracking (PTRAC) coincidence capture file allows a full list of neutron capture events to be recorded in any simulated detection medium. The originating event history number (e.g. spontaneous fission events), capture time, location and source particle number are tracked and output to file for post-processing. We have developed a new MCNPX PTRAC coincidence capture file capability to aid detector design studies. New features include the ability to track the nuclides that emitted the detected neutrons as well as induced fission chains in mixed samples before detection (both generation number and nuclide that underwent induced fission). Here, the power of this tool is demonstrated using a detector design developed for the non-destructive assay (NDA) of spent nuclear fuel. Individual capture time distributions have been generated for neutrons originating from Curium-244 source spontaneous fission events and induced fission events in fissile nuclides of interest: namely Plutonium-239, Plutonium-241, and Uranium-235. Through this capability, a full picture for the attribution of neutron capture events in the detector can be simulated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A multilevel Cartesian non-uniform grid time domain algorithm

A multilevel Cartesian non-uniform grid time domain algorithm (CNGTDA) is introduced to rapidly compute transient wave fields radiated by time dependent three-dimensional source constellations. CNGTDA leverages the observation that transient wave fields generated by temporally bandlimited and spatially confined source constellations can be recovered via interpolation from appropriately delay- and amplitude-compensated field samples. This property is used in conjunction with a multilevel scheme, in which the computational domain is hierarchically decomposed into subdomains with sparse non-uniform grids used to obtain the fields. For both surface and volumetric source distributions, the computational cost of CNGTDA to compute the transient field at N{sub s} observation locations from N{sub s} collocated sources for N{sub t} discrete time instances scales as O(N{sub t}N{sub s}logN{sub s}) and O(N{sub t}N{sub s}log{sup 2}N{sub s}) in the low- and high-frequency regimes, respectively. Coupled with marching-on-in-time (MOT) time domain integral equations, CNGTDA can facilitate efficient analysis of large scale time domain electromagnetic and acoustic problems.

97 MATHEMATICS AND COMPUTING↗

Numerical convergence and validation of the DIMP inverse particle transport model

The data integration with modeled predictions (DIMP) model is a promising inverse radiation transport method for solving the special nuclear material (SNM) holdup problem. Unlike previous methods, DIMP is a completely passive nondestructive assay technique that requires no initial assumptions regarding the source distribution or active measurement time. DIMP predicts the most probable source location and distribution through Bayesian inference and quasi-Newtonian optimization of predicted detector re-sponses (using the adjoint transport solution) with measured responses. DIMP performs well with for-ward hemispherical collimation and unshielded measurements, but several considerations are required when using narrow-view collimated detectors. DIMP converged well to the correct source distribution as the number of synthetic responses increased. DIMP also performed well for the first experimental validation exercise after applying a collimation factor, and sufficiently reducing the source search vol-ume's extent to prevent the optimizer from getting stuck in local minima. DIMP's simple point detector response function (DRF) is being improved to address coplanar false positive/negative responses, and an angular DRF is being considered for integration with the next version of DIMP to account for highly collimated responses. Overall, DIMP shows promise for solving the SNM holdup inverse problem, especially once an improved optimization algorithm is implemented.

42 ENGINEERING↗

Gaussianity of LISA's confusion backgrounds

Data analysis for the proposed Laser Interferometer Space Antenna (LISA) will be complicated by the huge number of sources in the LISA band. In the frequency band {approx}10{sup -4}-2x10{sup -3} Hz, galactic white dwarf binaries (GWDBs) are sufficiently dense in frequency space that it will be impossible to resolve most of them, and ''confusion noise'' from the unresolved Galactic binaries will dominate over instrumental noise in determining LISA's sensitivity to other sources in that band. Confusion noise from unresolved extreme-mass-ratio inspirals (EMRIs) could also contribute significantly to LISA's total noise curve. To date, estimates of the effect of LISA's confusion noise on matched-filter searches and their detection thresholds have generally approximated the noise as Gaussian, based on the central limit theorem. However in matched-filter searches, the appropriate detection threshold for a given class of signals may be located rather far out on the tail of the signal-to-noise probability distribution, where a priori it is unclear whether the Gaussian approximation is reliable. Using the Edgeworth expansion and the theory of large deviations, we investigate the probability distribution of the usual matched-filter detection statistic, far out on the tail of the distribution. We apply these tools to four somewhat idealized versions of LISA data searches: searches for EMRI signals buried in GWDB confusion noise, and searches for massive black hole binary signals buried in (i) GWDB noise, (ii) EMRI noise, and (iii) a sum of EMRI noise and Gaussian noise. Assuming reasonable short-distance cutoffs in the populations of confusion sources (since the very closest and hence strongest sources will be individually resolvable), modifications to the appropriate detection threshold, due to the non-Gaussianity of the confusion noise, turn out to be quite small for realistic cases. The smallness of the correction is partly due to the fact that these three types of sources evolve on quite different time scales, so no single background source closely resembles any search template. We also briefly discuss other types of LISA searches where the non-Gaussianity of LISA's confusion backgrounds could perhaps have a much greater impact on search reliability and efficacy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detector characterization for SCINTIA array

SCINTIA is a new detector array of organic scintillators under development at the Inst. for Reference Materials and Measurements (IRMM). The present design of SCINTIA includes NE213, p-terphenyl and Li glass neutron detectors positioned in a spherical configuration around the target. The properties of a novel p-terphenyl neutron detector to be used with SCINTIA have been investigated using photon sources and neutrons from a time tagged {sup 252}Cf(sf) source. The results show that the p-terphenyl crystal has better energy resolution, increased proton light output and neutron efficiency when compared to a similar size NE213 equivalent neutron detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron (>1 MeV) Room Return Effects on Subcritical HEU Castings

The prompt neutron decay has been measured for HEU metal castings by randomly pulsed neutron experiments with a time tagged 252 Cf spontaneous source of fission neutrons and a time and directionally tagged neutrons from a 14.1 MeV neutron generator and by time coincidence measurements between detectors. This paper evaluates the effect of neutrons (.1 MeV) promptly returning from the walls and floor of the room, in particular, how it affects the prompt neutron time decay.

36 MATERIALS SCIENCE↗

Statistics of baryon correlation functions in lattice QCD

A systematic analysis of the structure of single-baryon correlation functions calculated with lattice QCD is performed, with a particular focus on characterizing the structure of the noise associated with quantum fluctuations. The signal-to-noise problem in these correlation functions is shown, as long suspected, to result from a sign problem. The log-magnitude and complex phase are found to be approximately described by normal and wrapped normal distributions respectively. Properties of circular statistics are used to understand the emergence of a large time noise region where standard energy measurements are unreliable. Power-law tails in the distribution of baryon correlation functions, associated with stable distributions and “Lévy flights,” are found to play a central role in their time evolution. A new method of analyzing correlation functions is considered for which the signal-to-noise ratio of energy measurements is constant, rather than exponentially degrading, with increasing source-sink separation time. This new method includes an additional systematic uncertainty that can be removed by performing an extrapolation, and the signal-to-noise problem reemerges in the statistics of this extrapolation. It is demonstrated that this new method allows accurate results for the nucleon mass to be extracted from the large-time noise region inaccessible to standard methods. The observations presented here are expected to apply to quantum Monte Carlo calculations more generally. Similar methods to those introduced here may lead to practical improvements in analysis of noisier systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗