Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tilt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Effects of 1-week head-down tilt bed rest on bone formation and the calcium endocrine system

The -6-deg head-down tilt (HDT) is employed in the study of 8 subjects to determine early responses in human bone and calcium endocrines during spaceflight. The average rates of bone formation in the iliac crest are determined by means of a single-dose labeling schedule and are found to decrease in 6 of the subjects. The decrease varies directly with walking miles, and increased excretion of urinary Ca and Na are observed preceding increased levels of ionized serum calcium on a bed-rest day late in the week. Reduced phosphorous excretions are also followed by increased serum phosphorous on day six, and reductions are noted in parathyroid hormone and vitamin D by the end of the experiment. The data demonstrate the responsiveness of the skeletal system to biomechanical stimuli such as the HDT.

Arnaud, Sara B.↗

The effect of head-down tilt and water immersion on intracranial pressure in nonhuman primates

Intracranial pressure (ICP) is investigated in primates during and after -6-deg head-down tilt (HDT) and immersion in water to examine the effects of the headward fluid shift related to spaceflight. Following the HDT the primates are subjected to head-out thermoneutral water immersion, and the ICP is subsequently measured. ICP is found to increase from 3.8 +/- 1.1 to 5.3 +/- 1.3 mm Hg during the horizontal control period. ICP stabilizes at -6.3 +/- 1.3 mm Hg and then increases to -2.2 +/- 1.9 mm Hg during partial immersion, and ICP subsequently returns to preimmersion levels after immersion. These data indicate that exposure to HDT or water immersion lead to an early sharp increase in ICP, and water immersion alone leads to higher ICP levels. A significant conclusion of the work is that the ICP did not approach pathological levels, and this finding is relevant to human spaceflight research.

Keil, Lanny C.↗

Navier-Stokes computation of wing leading edge tangential blowing for a tilt rotor in hover

The effect of a thin tangential jet located at the leading edge of the wing of a tilt rotor configuration in hover is computed using the thin-layer Navier-stokes equations. Computations showed that leading edge tangential blowing is effective in reducing the download caused by the impingement of the rotor download caused by the impingement of the rotor downwash on the wing. Results from the numerical model support previous experimental findings that download reduction is due mainly to a decrease in upper surface pressure and not an increase in pressure on the lower surface. The numerical solution clearly shows that because of the three-dimensionality of the flow field, the download could be reduced further by allowing a spanwise variation in blowing strength.

Fejtek, Ian↗

An evaluation of the lower coverage anti-G suit without an abdominal bladder after 3 days of 7 deg head down tilt

Twelve healthy male subjects were initially deconditioned by 3 days of 7 deg head down tilt bed rest followed by donning the reentry anti-G suit and being centrifuged using a simulated Shuttle reentry profile. For 6 of the 12 subjects, anti-G suit pressure was increased in 0.5 psig increments if eye level blood pressure dropped below 70 mmHg. The second half of the subjects had their G-suits inflated in 0.5 psig increments if they reported 50 percent peripheral light dimming. Results show that the maximum allowable pressure for either exposure was 2.5 psig, which is the operational limit of the Shuttle anti-G suit controller.

Stegmann, B. J.↗

A tilted cold dark matter cosmological scenario

A new cosmological scenario based on CDM but with a power spectrum index of about 0.7-0.8 is suggested. This model is predicted by various inflationary models with no fine tuning. This tilted CDM model, if normalized to COBE, alleviates many problems of the standard CDM model related to both small-scale and large-scale power. A physical bias of galaxies over dark matter of about two is required to fit spatial observations.

Cen, Renyue↗

Piloted simulator investigations of a civil tilt-rotor aircraft on steep instrument approaches

NASA-Ames has used its Vertical Motion Simulator to investigate steep-glideslope instrument approaches for a civil transport tilt-rotor aircraft in two different cases: (1) where pilots used raw glideslope and localized error data for 6-25 deg slopes, terminating in slow roll-on landings, and (2) where a flight director commanded manual conversion from fixed-wing to helicopter modes and a deceleration on the glideslope led to a vertical landing on a small urban helipad. In the former, there occurred control problems directly ascribable to the slow approach speed; in the latter, the four-cue flight director's cockpit augmentation furnished adequate pilot ratings up to 15-deg glideslope.

Decker, William A.↗

Cerebral blood velocity and other cardiovascular responses to 2 days of head-down tilt

Spaceflight induces a cephalad redistribution of fluid volume and blood flow within the human body, and space motion sickness, which is a problem during the first few days of space flight, could be related to these changes in fluid status and in blood flow of the cerebrum and vestibular system. To evaluate possible changes in cerebral blood flow during simulated weightlessness, we measured blood velocity in the middle cerebral artery (MCA) along with retinal vascular diameters, intraocular pressure, impedance cardiography, and sphygmomanometry on nine men (26.2 +/- 6.6 yr) morning and evening for 2 days during continuous 10 deg head-down tilt (HDT). When subjects went from seated to head-down bed rest, their heart rate and retinal diameters decreased, and intraocular pressures increased. After 48 h of HDT, blood flow velocity in the MCA was decreased and thoracic impedance was increased, indicating less fluid in the thorax. Percent changes in blood flow velocities in the MCA after 48 h of HDT were inversely correlated with percent changes in retinal vascular diameters. Blood flow velocities in the MCA were inversely correlated (intersubject) with arterial pressures and retinal vascular diameters. Heart rate, stroke volume, cardiac output, systolic arterial pressure, and at times pulse pressure and blood flow velocities in the MCA were greater in the evening. Total peripheral resistance was higher in the morning. Although cerebral blood velocity is reduced after subjects are head down for 2 days, the inverse relationship with retinal vessel diameters, which have control analogous to that of cerebral vessels, indicates cerebral blood flow is not reduced.

Frey, Mary A. B.↗

Cerebral blood flow velocity in humans exposed to 24 h of head-down tilt

This study investigates cerebral blood flow (CBF) velocity in humans before, during, and after 24 h of 6 deg head-down tilt (HDT), which is a currently accepted experimental model to simulate microgravity. CBF velocity was measured by use of the transcranial Doppler technique in the right middle cerebral artery of eight healthy male subjects. Mean CBF velocity increased from the pre-HDT upright seated baseline value of 55.5 +/- 3.7 (SE) cm/s to 61.5 +/- 3.3 cm/s at 0.5 h of HDT, reached a peak value of 63.2 +/- 4.1 cm/s at 3 h of HDT, and remained significantly above the pre-HDT baseline for over 6 h of HDT. During upright seated recovery, mean CBF velocity decreased to 87 percent of the pre-HDT baseline value. Mean CBF velocity correlated well with calculated intracranial arterial pressure (IAP). As analyzed by linear regression, mean CBF velocity = 29.6 + 0.32IAP. These results suggest that HDT increases CBF velocity by increasing IAP during several hours after the onset of microgravity. Importantly, the decrease in CBF velocity after HDT may be responsible, in part, for the increased risk of syncope observed in subjects after prolonged bed rest and also in astronauts returning to Earth.

Kawai, Y.↗

A hydrodynamic treatment of the tilted cold dark matter cosmological scenario

A standard hydrodynamic code coupled with a particle-mesh code is used to compute the evolution of a tilted cold dark matter (TCDM) model containing both baryonic matter and dark matter. Six baryonic species are followed, with allowance for both collisional and radiative ionization in every cell. The mean final Zel'dovich-Sunyaev y parameter is estimated to be (5.4 +/- 2.7) x 10 exp -7, below currently attainable observations, with an rms fluctuation of about (6.0 +/- 3.0) x 10 exp -7 on arcmin scales. The rate of galaxy formation peaks at a relatively late epoch (z is about 0.5). In the case of mass function, the smallest objects are stabilized against collapse by thermal energy: the mass-weighted mass spectrum peaks in the vicinity of 10 exp 9.1 solar masses, with a reasonable fit to the Schechter luminosity function if the baryon mass to blue light ratio is about 4. It is shown that a bias factor of 2 required for the model to be consistent with COBE DMR signals is probably a natural outcome in the present multiple component simulations.

Cen, Renyue↗

N.A.C.A. Langley Field Wind Tunnel Apparatusthe Tilting Manometer

A description is given of a tilting manometer designed to meet the requirements of a manometer for use in the wind tunnel at the Langley Memorial Aeronautical Laboratory. This gauge was designed to meet the requirements of a manometer in use in connection with a static pressure plate to indicate the wind speed in the tunnel. The requirements are noted. The sensitivity of the gauge must be made inversely proportional to the pressure to be measured. The gauge must be accurately and quickly set for any desired pressure. When set at the desired pressure, the extent of variation between the existing and the desired pressures may be readily estimated. In fact, this manometer is quick to adjust, is easy to read, always has the meniscus in the same position, and accurately indicates a large range of air speeds on what is a comparatively compact instrument.

Norton, F H↗

Fluid compartment and renal function alterations in the rat during 7 and 14 day head down tilt

Exposure to conditions of microgravity for any extended duration can modify the distribution of fluid within the vascular and interstitial spaces, and eventually intracellular volume. Whether the redistribution of fluid and resetting of volume homeostasis mechanisms is appropriate for the long term environmental requirements of the body in microgravity remains to be fully defined. The event that initiates the change in fluid volume homeostasis is the cephalad movement of fluid which potentially triggers volume sensors and stretch receptors (atrial stretch with the resulting release of atrial natriuretic peptide) and suppresses adrenergic activity via the carotid and aortic arch baroreceptors. All these events act in concert to reset blood and interstitial volume to new levels, which in turn modify the renin-angiotensin system. All these factors have an influence on the kidney, the end organ for fluid volume control. How the fluid compartment volume changes interrelate with alterations in renal functions under conditions of simulated microgravity is the focus of the present investigation which utilizes 25-30 deg head-down tilt in the rat.

Tucker, Bryan J.↗

Plasma volume shifts and exercise thermoregulation with water immersion and six-degree head-down tilt

The hypothesized fluid shifts and resultant responses that occur during spaceflight are simulated by six-degree head down tilt (HDT) and water immersion (WI). The purpose of this study was to compare exercise thermoregulation before and after physiologic mechanisms reduce plasma volume (PV) in response to 24-hr HDT (HDT24). A secondary study utilized WI to reproduce the PV reduction of HDT24. Seven males were studied in two conditions: during 70 minutes of supine cycling ergometry at 58 percent of peak oxygen consumption following 1-hr HDT (HDT1) and HDT24; and up to 6 hr WI at 34.5 C. Plasma volume was reduced by 10.4 percent in HDT24 when compared to HDT1. Pre-exercise rectal temperature, T(sub re), was an average 0.22 C higher after HDT24. Rectal temperature increased during exercise with no interaction between time and treatment. The reduced PV and elevated pre-exercise T(sub re) had offsetting effects on thermoregulatory mechanisms, suggesting no alteration in the response at a given T(sub re). Plasma volume was reduced by 4.3 +/- 2.3 percent and 1.1 +/- 1.8 percent following HDT24 and WI, respectively, compared to upright chair rest. Although the reductions in PV were not significantly different, great intra-individual variability was evident. The ability to reproduce PV changes consistently with HDT and WI is limited by this variability.

Ertl, Andrew Carl↗

The effect of intermittent standing or walking during head down tilt bedrest on peak O2 consumption

The cardiovascular aspect of bedrest deconditioning is manifested by decreases in peak O2 uptake (VO(sub 2 peak)) during minimal exercise. The effect of intermittent standing (+G(z)) or walking (+G(z)W) during 4 days of 7 degree Head Down Tilt bedrest (HDT) on VO(sub 2 peak) was evaluated. Methods: Five protocols were performed by eight male subjects; control (C) consisting of complete bedrest, and 15 minute periods to total 2 or 4 hours daily of standing (+G(z)(exp 2) and +G(z)(exp 4) respectively) or walking at 3.0 MPH (+G(z)W2 and +G(z)W4 respectively). Subjects performed VO(sub 2 peak) tests prior to and on the final day of HDT. VO(sub 2 peak) was determined using open circuit indirect calorimetry during supine leg cycling ergometry. After a 5 minute warmup, three 2 minute incremental loads of 33 W previously determined to elicit VO(sub 2 peak) were given and the subject cycled to volitional fatigue. Results: The C protocol VO(sub 2 peak) decreased by 16 percent (2.71 plus or minus 0.16 to 2.27 plus or minus 0.14 L/min) and 11 percent in +G(z)(exp 4) (2.72 plus or minus 0.15 to 2.43 plus or minus 0.14 L/min). With +G(z)W2 VO(sub 2 peak) decreased by 9 percent (2.71 plus or minus 0.17 to 2.46 plus or minus 0.14 L/min) and with +G(z)W4, VO(sub 2 peak) decreased by 10 percent (2.71 plus or minus 0.14 to 2.43 plus or minus 0.14 L/min). VO(sub 2 peak) in all protocols decreased with HDT (P less than 0.05). The decrease in C VO(sub 2 peak) was significantly greater (P less than 0.05) than the decreases in either +G(z) or +G(z)W protocols. Conclusion: The deconditioning that occurs after only 4 days of HDT was demonstrated by decreases in VO(sub 2 peak). Intermittent +G(z) or +G(z)W attenuated, but did not prevent, the decrease in VO(sub 2 peak) with HDT.

Ertl, A. C.↗

Three-parameter tunable Tilt-Integral-Derivative (TID) controller

A feedback control system compensator of the PID type is provided, wherein the proportional component of the compensator is replaced with a tilted component having a transfer function s to the power of -1/n. The resulting transfer function of the entire compensator more closely approximates an optimal transfer function, thereby achieving improved feedback controller. Further, as compared to conventional PID compensators, the TID compensator allows for simpler tuning, better disturbance rejection ratio, and smaller effects of plant parameter variations on closed loop response.

Lurie, Boris J.↗

Altered thermoregulatory responses after 15 days of head-down tilt

To determine whether extended exposure to a simulation of microgravity alters thermoregulatory reflex control of skin blood flow, six adult males were exposed to 15 days of 6 deg head-down tilt (HDT). On an ambulatory control day before HDT exposure and on HDT day 15 the core temperature of each subject was increased by 0.5 - 1.0 C by whole body heating with a water-perfused suit. Mean skin temperature, oral temperature (T (sub or)), mean arterial pressure, and forearm blood flow were measured throughout the protocol. Forearm vascular conductance (FVC) was calculated from the ratio of forearm blood flow to mean arterial pressure. After HDT exposure, the T(sub or) threshold at which reflex thermally induced increases in FVC began was elevated, whereas the slope of the T(sub or)-FVC relationship after this threshold was reduced. Moreover, normothermic FVC and FVC at the highest common T(sub or) between pre- and post-HDT trials were reduced after HDT. These data suggest that HDT exposure reduces thermoregulatory responses to heat stress. The mechanisms resulting in such an impaired thermoregulatory response are unknown but are likely related to the relative dehydration that accompanies this exposure.

Crandall, Craig G.↗

Dual Telecentric Lens System For Projection Onto Tilted Toroidal Screen

System of two optical assemblies for projecting image onto tilted toroidal screen. One projection lens optimized for red and green spectral region; other for blue. Dual-channel approach offers several advantages which include: simplified color filtering, simplified chromatic aberration corrections, less complex polarizing prism arrangement, and increased throughput of blue light energy. Used in conjunction with any source of imagery, designed especially to project images formed by reflection of light from liquid-crystal light valve (LCLV).

Gold, Ronald S.↗

Lower body negative pressure chamber: Design and specifications for tilt-table mounting

Specifications for a lower body negative pressure chamber for mounting on a tilting table are presented. The main plate is made from HEXEL honeycomb board 1.0 inch thick. The plate, supported at three edges, will be subjected to a uniform pressure differential of -4.7 lb/sq in. A semi-cylindrical Plexiglass top (chamber) is attached to the main plate; the pressure within the chamber will be about 10lb/sq in during operation. The stresses incurred by the main plate with this partial vacuum were calculated. All linear dimensions are in inches.

Salamacha, Laura↗

Reducing Tilt-Related Errors Of Inductive Proximity Sensors

Simple modification of inductive proximity sensor nearly eliminates tilt-related readout error occurring when sensor used to measure thickness of dielectric layer on metal substrate (e.g., to measure thickness of insulating blanket on boiler). Sensor indicates true thickness when equipped with hemispherical contact knob ensuring correct zero-offset distance at measurement location.

Cotty, Glenn M., Jr.↗