Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

On The Processing of Log Files for Monitoring Antenna Health

In order to improve the quality of geodetic results, we have developed an infrastructure for timely processing of telemetry from IVS observing stations. We check every hour for new log files with telemetry from both VLBI observing sessions, single dish experiments, and stow-in data collection and automatically process them. The telemetry data we use is the system temperature, phase calibration phases and amplitudes, system equivalent flux density, and the differences between formatter clock and GPS clock. For the system temperature and phase calibration, processing includes filtering out outliers and computing averages and rms of the scatter in each scan. Furthermore, for the phase calibration we also compute the group delay and detect spurious signals. Cleaned and post-processed telemetry is archived. Our process detects abnormalities, such as, anomalously high system temperature, unstable phase calibration phases, jumps in the GPS and formatter clock differences, and others. With our procedure, the latency of detection of station abnormalities is reduced to less than two hours. Early detection of abnormalities reduces the amount of affected data since station personnel get early alerts. We discuss our experience of running this system since 2022.

VLBI↗

A Portable Ground-Based Atmospheric Monitoring System (PGAMS) for the Calibration and Validation of Atmospheric Correction Algorithms Applied to Aircraft and Satellite Images

Detecting changes in the Earth's environment using satellite images of ocean and land surfaces must take into account atmospheric effects. As a result, major programs are underway to develop algorithms for image retrieval of atmospheric aerosol properties and atmospheric correction. However, because of the temporal and spatial variability of atmospheric transmittance it is very difficult to model atmospheric effects and implement models in an operational mode. For this reason, simultaneous in situ ground measurements of atmospheric optical properties are vital to the development of accurate atmospheric correction techniques. Presented in this paper is a spectroradiometer system that provides an optimized set of surface measurements for the calibration and validation of atmospheric correction algorithms. The Portable Ground-based Atmospheric Monitoring System (PGAMS) obtains a comprehensive series of in situ irradiance, radiance, and reflectance measurements for the calibration of atmospheric correction algorithms applied to multispectral. and hyperspectral images. The observations include: total downwelling irradiance, diffuse sky irradiance, direct solar irradiance, path radiance in the direction of the north celestial pole, path radiance in the direction of the overflying satellite, almucantar scans of path radiance, full sky radiance maps, and surface reflectance. Each of these parameters are recorded over a wavelength range from 350 to 1050 nm in 512 channels. The system is fast, with the potential to acquire the complete set of observations in only 8 to 10 minutes depending on the selected spatial resolution of the sky path radiance measurements

Schiller, Stephen↗

Automatic Calibration of an Airborne Imaging System to an Inertial Navigation Unit

This software automatically calibrates a camera or an imaging array to an inertial navigation system (INS) that is rigidly mounted to the array or imager. In effect, it recovers the coordinate frame transformation between the reference frame of the imager and the reference frame of the INS. This innovation can automatically derive the camera-to-INS alignment using image data only. The assumption is that the camera fixates on an area while the aircraft flies on orbit. The system then, fully automatically, solves for the camera orientation in the INS frame. No manual intervention or ground tie point data is required.

Ansar, Adnan I.↗

Rotating pressure measurement system using an on board calibration standard

A computer-controlled multichannel pressure measurement system was developed to acquire detailed flow field measurements on board the Large Low Speed Centrifugal Compressor Research Facility at the NASA Lewis Research Center. A pneumatic slip ring seal assembly is used to transfer calibration pressures to a reference standard transducer on board the compressor rotor in order to measure very low differential pressures with the high accuracy required. A unique data acquisition system was designed and built to convert the analog signal from the reference transducer to the variable frequency required by the multichannel pressure measurement system and also to provide an output for temperature control of the reference transducer. The system also monitors changes in test cell barometric pressure and rotating seal leakage and provides an on screen warning to the operator if limits are exceeded. The methods used for the selection and testing of the the reference transducer are discussed, and the data acquisition system hardware and software design are described. The calculated and experimental data for the system measurement accuracy are also presented.

Senyitko, Richard G.↗

InSight attitude control system thruster characterization and calibration for successful navigation to Mars

In order for the InSight spacecraft to execute a safe Mars landing, it was crucial that the navigation team accurately predict the trajectory and deliver the spacecraft to the targeted atmospheric entry point. One of the primary challenges faced by the Navigation Team was the accurate reconstruction and prediction of small but frequent velocity changes imparted by the spacecraft’s Attitude Control System thrusters. This paper discusses the in-flight thruster calibration campaign, the reconstruction and prediction of accelerations throughout various phases of cruise (including compensating for significant outgassing after launch and attitude transition), and the subsequent impact on atmospheric entry point delivery

McCandless, Sarah Elizabeth↗

Self-Calibrating and Remote Programmable Signal Conditioning Amplifier System and Method

A self-calibrating, remote programmable signal conditioning amplifier system employs information read from a memory attached to a measurement transducer for automatic calibration. The signal conditioning amplifier is self-calibrated on a continuous basis through use of a dual input path arrangement, with each path containing a multiplexer and a programmable amplifier. A digital signal processor controls operation of the system such that a transducer signal is applied to one of the input paths, while one or more calibration signals are applied to the second input path. Once the second path is calibrated, the digital signal processor switches the transducer signal to the second path. and then calibrates the first path. This process is continually repeated so that each path is calibrated on an essentially continuous basis. Dual output paths are also employed which are calibrated in the same manner. The digital signal processor also allows the implementation of a variety of digital filters which are either programmed into the system or downloaded by an operator, and performs up to eighth order linearization.

Medelius, Pedro J.↗

Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams

Online monitoring is a key challenge for the continued development of molten salt reactor (MSR) technology. Laser-induced breakdown spectroscopy (LIBS) has previously been demonstrated to be a viable tool for monitoring aerosolized species and noble gases in real time, but the ability to discern varying isotopes in these streams has not yet been investigated for MSR applications. Tritium will form in MSRs from ternary fission and from (n,α)-reactions occurring in lithium-containing salts. This study compares three spectrometers of varying resolutions and types for measuring hydrogen isotope shifts in LIBS spectra of wetted filter paper. For each spectrometer, multivariate models were built (i.e., principal component regression, partial least squares regression, and multivariate curve resolution) to quantify the isotope ratio. The top models were then modified and corrected to apply the models to aerosol samples with varying isotope ratios. This novel calibration strategy offers an 82% reduction in volume of the calibration samples needed and is a more viable pathway for calibrating deployable LIBS systems. Lastly, this calibration model was compared with an all-aerosol trained model for monitoring hydrogen isotopes during a real-time test where the protium/deuterium ratio, along with representative salt species (i.e., lithium, sodium, and potassium) were adjusted dynamically. Results of this test validated the predictive capabilities of the transferred model and highlighted the capabilities of LIBS for real-time monitoring of MSR effluent streams.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vacuum system for an infrared calibration facility.

Calibration facilities for large aperture (up to 56 cm diam) infrared radiometers require commeasurable size vacuum chambers with full thermal shrouding and ultraclean pumping systems. Such a facility has been fabricated and is described in detail. The chamber is 106 cm in diameter and 4.87 m long. It utilizes integral ion pumping for operation in the 1 microtorr region. Economic considerations and time constraints of the total system program required local fabrication and, therefore, nonproprietary-type flange sealing.The sealing mechanism used was the flat flange with aluminum wire effecting the seal. Included in the discussion is the description of the cryogen distribution system which allows complete constant temperature control of the several shroud structures.

Uhlin, J.↗

Surface roughness measuring system

Significant height information of ocean waves, or peaks of rough terrain is obtained by compressing the radar signal over different widths of the available chirp or Doppler bandwidths, and cross-correlating one of these images with each of the others. Upon plotting a fixed (e.g., zero) component of the cross-correlation values as the spacing is increased over some empirically determined range, the system is calibrated. To measure height with the system, a spacing value is selected and a cross-correlation value is determined between two intensity images at a selected frequency spacing. The measured height is the slope of the cross-correlation value used. Both electronic and optical radar signal data compressors and cross-correlations are disclosed for implementation of the system.

Jain, A.↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the x-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M.C.↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the x-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M. C.↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the X-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M. C.↗

Particle Size Calibration Testing in the NASA Propulsion Systems Laboratory

The particle size characterization portion of the 2017 Propulsion Systems Laboratory (PSL) Cloud Calibration is described. The work focuses on characterizing the particle size distribution of the icing cloud as a function of simulated atmospheric conditions.These results will aid in upcoming ice crystal and supercooled liquid icing tests in PSL. Measurements acquired with the Phase Doppler Interferometer and High Speed Imaging instruments are presented. Experimental results indicate that the particle size distribution is primarily a function nozzle air and water pressures, and that air speed is not a significant effect for ice crystal clouds in PSL and both thermodynamic conditions and air speed are not significant effects for supercooled liquid water clouds in PSL.

Engine icing↗

Particle Size Calibration Testing in the NASA Propulsion Systems Laboratory

The particle size characterization portion of the 2017 Propulsion Systems Laboratory (PSL) Cloud Calibration is described. The work focuses on characterizing the particle size distribution of the icing cloud as a function of simulated atmospheric conditions.These results will aid in upcoming ice crystal and supercooled liquid icing tests in PSL. Measurements acquired with the Phase Doppler Interferometer and High Speed Imaging instruments are presented. Experimental results indicate that the particle size distribution is primarily a function nozzle air and water pressures, and that air speed is not a significant effect for ice crystal clouds in PSL and both thermodynamic conditions and air speed are not significant effects for supercooled liquid water clouds in PSL.

Engine Icing↗

Improving Photometric Calibration of Meteor Video Camera Systems

Current optical observations of meteors are commonly limited by systematic uncertainties in photometric calibration at the level of approximately 0.5 mag or higher. Future improvements to meteor ablation models, luminous efficiency models, or emission spectra will hinge on new camera systems and techniques that significantly reduce calibration uncertainties and can reliably perform absolute photometric measurements of meteors. In this talk we discuss the algorithms and tests that NASA's Meteoroid Environment Office (MEO) has developed to better calibrate photometric measurements for the existing All-Sky and Wide-Field video camera networks as well as for a newly deployed four-camera system for measuring meteor colors in Johnson-Cousins BV RI filters. In particular we will emphasize how the MEO has been able to address two long-standing concerns with the traditional procedure, discussed in more detail below.

Ehlert, Steven↗

Calibrating the Helium Pressurization System for the Space Shuttle Liquid-Hydrogen Tank

Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.

Source record↗

Multimode ergometer system

System overcomes previous ergometer design and calibration problems including inaccurate measurements, large weight, size, and input power requirements, poor heat dissipation, high flammability, and inaccurate calibration. Device consists of lightweight, accurately controlled ergometer, restraint system, and calibration system.

Bynum, B. G.↗