Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Perturbative theory of grazing-incidence diffuse nuclear resonant scattering of synchrotron radiation

Theoretical description of off-specular grazing-incidence nuclear resonant scattering of synchrotron radiation (synchrotron Moessbauer reflectometry, SMR) is presented. The recently developed SMR, similar to polarized neutron reflectometry (PNR), is an analytical tool for the determination of isotopic and magnetic structure of thin films and multilayers. It combines the sensitivity of Moessbauer spectroscopy to hyperfine interactions and the depth selectivity of x-ray reflectometry. Specular reflection provides information on the depth profile, while off-specular scattering on the lateral structure of scattering layers. Off-specular SMR and PNR intensity formulas of a rather general multilayer with different domains, based on a distorted incident-wave approximation (DIWA), are presented. The distorted-wave Born approximation results are given in an appendix. Physical and numerical implications, of using DIWA are explained. The temporal character of SMR imposes specific differences between SMR and PNR. In order to reveal the limits of DIWA and to compare the two analytical methods, two-dimensional diffuse SMR and PNR maps of an antiferromagnetic multilayer are calculated and critically compared. Experimental ''{omega}-2{theta}'' SMR map of a periodic [Fe/Cr]{sub 20} multilayer is presented and compared with simulations by the present theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solution Synchrotron X-ray Diffraction Reveals Structural Details of Lipid Domains in Ternary Mixtures

The influence of cholesterol on lipid bilayer structure is significant and the effect of cholesterol on lipid sorting and phase separation in lipid-raft-forming model membrane systems has been well investigated by microscopy methods on giant vesicles. An important consideration however is the influence of fluorescence illumination on the phase state of these lipids and this effect must be carefully minimized. In this paper, we show that synchrotron x-ray scattering on solution lipid mixtures is an effective alternative technique for the identification and characterization of the l o (liquid ordered) and l d (liquid disordered) phases. The high intensity of synchrotron x rays allows the observation of up to 5 orders of diffraction from the l o phase, whereas only two are clearly visible when the l d phase alone is present. This data can be collected in approximately 1 min/sample, allowing rapid generation of phase data. In this paper, we measure the lamellar spacing in both the liquid-ordered and liquid-disordered phases simultaneously, as a function of cholesterol concentration in two different ternary mixtures. We also observe evidence of a third gel-phaselike population at 10-12 mol % cholesterol and determine the thickness of the bilayer for this phase. Importantly we are able to look at phase coexistence in the membrane independent of photoeffects.

43 PARTICLE ACCELERATORS↗

Experimental observation of increased threshold electric field for runaway generation due to synchrotron radiation losses in the FTU tokamak

The threshold electric field for runaway generation has been investigated during runaway suppression experiments by means of electron-cyclotron-resonance heating in the flattop phase of FTU discharges. Runaway suppression has been experimentally found to occur at electric fields substantially larger than those predicted by the relativistic collisional theory of runaway generation, E{sub R} = n{sub e}e{sup 3}ln{Lambda}/4{pi}{var_epsilon}{sub 0}{sup 2}m{sub e}c{sup 2}. These experimental results are consistent with an increase of the critical electric field due to the electron synchrotron radiation losses. No runaway electrons are found in FTU experiments below the radiation threshold. These results support evidence for a new threshold electric field for runaway generation that accounts for the effect of the synchrotron losses, and which should be considered when making predictions on runaway generation and mitigation in devices such as ITER.

43 PARTICLE ACCELERATORS↗

Synchrotron Mossbauer spectroscopy using high-speed shutters.

A new method of performing Moessbauer spectroscopy with synchrotron radiation is demonstrated that involves using a high-speed periodic shutter near the focal spot of a microfocused X-ray beam. This fast microshuttering technique operates without a high-resolution monochromator and has the potential to produce much higher signal rates. It also offers orders of magnitude more suppression of unwanted electronic charge scattering. Measurement results are shown that prove the principle of the method and improvements are discussed to deliver a very pure beam of Moessbauer photons (E/{Delta}E {approx_equal} 10{sup 12}) with previously unavailable spectral brightness. Such a source will allow both Moessbauer spectroscopy in the energy domain with the many advantageous characteristics of synchrotron radiation and new opportunities for measurements using X-rays with ultra-high energy resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microprobing the Molecular Spatial Distribution and Structural Architecture of Feed-type Sorghum Seed Tissue (Sorghum Bicolor L.) using the Synchrotron Radiation Infrared Microspectroscopy Technique

Sorghum seed (Sorghum bicolor L.) has unique degradation and fermentation behaviours compared with other cereal grains such as wheat, barley and corn. This may be related to its cell and cell-wall architecture. The advanced synchrotron radiation infrared microspectroscopy (SR-IMS) technique enables the study of cell or living cell biochemistry within cellular dimensions. The objective of this study was to use the SR-IMS imaging technique to microprobe molecular spatial distribution and cell architecture of the sorghum seed tissue comprehensively. High-density mapping was carried out using SR-IMS on beamline U2B at the National Synchrotron Light Source (Brookhaven National Laboratory, NY, USA). Molecular images were systematically recorded from the outside to the inside of the seed tissue under various chemical functional groups and their ratios [peaks at {approx}1725 (carbonyl C=O ester), 1650 (amide I), 1657 (protein secondary structure {alpha}-helix), 1628 (protein secondary structure {beta}-sheet), 1550 (amide II), 1515 (aromatic compounds of lignin), 1428, 1371, 1245 (cellulosic compounds in plant seed tissue), 1025 (non-structural CHO, starch granules), 1246 (cellulosic material), 1160 (CHO), 1150 (CHO), 1080 (CHO), 930 (CHO), 860 (CHO), 3350 (OH and NH stretching), 2960 (CH{sub 3} anti-symmetric), 2929 (CH{sub 2} anti-symmetric), 2877 (CH{sub 3} symmetric) and 2848 cm{sup -1} (CH{sub 2} asymmetric)]. The relative protein secondary structure {alpha}-helix to {beta}-sheet ratio image, protein amide I to starch granule ratio image, and anti-symmetric CH{sub 3} to CH{sub 2} ratio image were also investigated within the intact sorghum seed tissue. The results showed unique cell architecture, and the molecular spatial distribution and intensity in the sorghum seed tissue (which were analyzed through microprobe molecular imaging) were generated using SR-IMS. This imaging technique and methodology has high potential and could be used for scientists to develop specific cereal grain varieties with targeted food and feed quality, and can also be used to monitor the degree of grain maturity, grain damage, the fate of organic contaminants and the effect of chemical treatment on plant and grain seeds.

09 BIOMASS FUELS↗

Application of X-ray synchrotron microscopy instrumentation in biology

X-ray micro-fluorescence imaging technique has been used as a significant tool in order to investigate minerals contents in some kinds of materials. The aim of this study was to evaluate the elemental distribution of calcium and zinc in bone substitute materials (nano-hydroxyapatite spheres) and cortical bones through X-Ray Micro-fluorescence analysis with the increment of Synchrotron Radiation in order to evaluate the characteristics of the newly formed bone and its interface, the preexisting bone and biomaterials by the arrangement of collagen fibers and its birefringence. The elemental mapping was carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo, Brazil working at D09-XRF beam line. Based on this study, the results suggest that hydroxyapatite-based biomaterials are biocompatible, promote osteo-conduction and favored bone repair. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization Studies of CdZnTe Detectors Using Synchrotron X-ray Radiation

High densities of impurities and defects lead to severe charge-carrier trapping that can be major issues in assuring the high performance of CZT detectors. For some medical-imaging applications, the typical X-ray flux can be very high. Under such high irradiation conditions, the trapped charge builds up inside the detector affecting its stability. This phenomenon generally is termed the polarization effect. We conducted detailed studies on polarization in CZT crystals employing a highly collimated synchrotron X-ray radiation source available at Brookhaven's National Synchrotron Light Source (NSLS). We were able to induce polarization effects by irradiating specific areas within the detector. These measurements allowed us to make, for the first time, a quantitative comparison between areas where polarization is induced, and the electron- and hole-collection X-ray maps obtained at low flux, where no polarization is induced. We discuss the results of these polarization studies.

43 PARTICLE ACCELERATORS↗

High Spatial Resolution Analysis of Fungal Cell Biochemistry: Bridging the Analytical Gap using Synchrotron FTIR Spectromicroscopy

Fungi impact humans and the environment in many ways, for good and ill. Some fungi support the growth of terrestrial plants or are used in biotechnology, and yet others are established or emerging pathogens. In some cases, the same organism may play different roles depending on the context or the circumstance. A better understanding of the relationship between fungal biochemical composition as related to the fungal growth environment is essential if we are to support or control their activities. Synchrotron FTIR (sFTIR) spectromicroscopy of fungal hyphae is a major new tool for exploring cell composition at a high spatial resolution. Brilliant synchrotron light is essential for this analysis due to the small size of fungal hyphae. sFTIR biochemical characterization of subcellular variation in hyphal composition will allow detailed exploration of fungal responses to experimental treatments and to environmental factors.

43 PARTICLE ACCELERATORS↗

Assessment of BoneTtissue Mineralization by Conventional X-ray Microcomputed tomography: Comparison with Synchrotron Radiation Microcomputed Tomography and Ash Measurements

Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SR{mu}CT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop {mu}CT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional {mu}CT. The goal of this study was to evaluate {mu}CT-based measurement of degree and distribution of tissue mineralization in a quantitative, spatially resolved manner. Specifically, {mu}CT measures of bone mineral content (BMC) and TMD were compared to those obtained by SR{mu}CT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic {mu}CT system at an isotropic voxel size of 8 {mu}m. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mgHA/cm3. SR{mu}CT imaging was performed at an isotropic voxel size of 7.50 {mu}m at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. {mu}CT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mgHA/cm3 correction resulting in a 4.7% higher TMD value. {mu}CT and SR{mu}CT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SR{mu}CT values. In low volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SR{mu}CT values. {mu}CT and SR{mu}CT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97-1.00; TMD R2=0.78-0.99). Ash mass and density were higher than the SR{mu}CT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus {mu}CT R2=0.96-1.00; ash versus SR{mu}CT R2=0.99-1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus {mu}CT R2=0.64-0.72; ash versus SR{mu}CT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the {mu}CT data, which were reduced (but not eliminated) using the 1200 mg HA/cm3 beam hardening correction, and did not exist in the SR{mu}CT data. This study represents the first quantitative comparison of {mu}CT mineralization evaluation against SR{mu}CT and gravimetry. Our results indicate that {mu}CT mineralization measures are underestimated but well-correlated with SR{mu}CT and gravimetric data, particularly when volume fraction groups are considered individually.

43 PARTICLE ACCELERATORS↗

Optimization of the conditions of synchrotron Mössbauer experiment for studying electronic transitions at high pressures by the example of (Mg, Fe)O magnesiowustite

The effect of the experimental conditions on the shape of the nuclear resonant forward scattering (NFS) from (Mg{sub 0.75}Fe{sub 0.25})O magnesiowustite has been studied at high pressures up to 100 GPa in diamond anvil cells by the method of the NFS of synchrotron radiation from the Fe-57 nuclei at room temperature. The behavior of the system in the electronic transition of the Fe{sup 2+} ion from the high-spin to low-spin state (spin crossover) near 62 GPa is analyzed as a function of the sample thickness, degree of nonhydrostaticity, and focusing and collimation conditions of a synchrotron beam. It is found that the inclusion of dynamical beats associated with the sample thickness is very important in the approximation of the experimental NFS spectra. It is shown that the electronic transition occurs in a much narrower pressure range ({+-}6 GPa) rather than in a broad range as erroneously follows from experiments with thick samples under strongly nonhydrostatic conditions.

43 PARTICLE ACCELERATORS↗

Structural studies of the lipid membranes at the Siberia-2 synchrotron radiation source

Lipid membranes are a subject of contemporary interdisciplinary studies at the junction of biology, biophysics, pharmacology, and bionanotechnology. The results of the structural studies of several types of lipid membranes by the lamellar and lateral diffraction of X-ray synchrotron radiation are presented. The experiments were performed at the Mediana and DICSI stations of the Siberia-2 synchrotron radiation source at the Russian Research Center Kurchatov Institute. The data obtained are compared with the results of studying lipid membranes at the small-angle scattering beamlines D22 and D24 at LURE (France) and at the A2 beamline at DESY (Germany). The parameters of the DICSI station are shown to meet the basic requirements for the structural study of lipid systems, which are of fundamental and applied interest.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Kinetics of Solid Phase Transition in Tetracosane С{sub 24}Н{sub 50} by High-Resolution Synchrotron X-Ray Powder Diffraction

Using the small-angle synchrotron X-ray diffraction method at the research facility “BELOK” of the Kurchatov synchrotron radiation source at the NRC Kurchatov Institute, it was shown that the first-order solid phase transition in tetracosane C{sub 24}H{sub 50} passes according to a heterogeneous mechanism in a narrow temperature range ΔT ~ 1 K in accordance with the theory of diffuse phase transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aleurone Cell Walls of Wheat Grain: High Spatial Resolution Investigation Using Synchrotron Infrared Microspectroscopy

Infrared microspectroscopy and immunolabeling techniques were employed in order to obtain deeper insight into the biochemical nature of aleurone cell walls of wheat grain. The use of a synchrotron source, thanks to its intrinsic brightness, has provided unprecedented information at the level of a few micrometers and has allowed the discrimination of various polysaccharides in cell walls. The high spectral quality obtained in the small analyzed domain has been beneficial in estimating the relative proportions of {Beta}-glucan and arabinoxylan, through the use of principal component analysis (PCA). The highest amount of {Beta}-glucan is found in periclinal cell walls close to the starchy endosperm. The junction regions between aleurone cells are enriched in arabinoxylan. At the early stage of wheat grain development (271 degrees D), the chemical composition along the cell walls is more heterogeneous than at the mature stage. Both synchrotron infrared microspectroscopy and immunolabeling experiments made it possible to reveal the spatial heterogeneity of the various chemical compositions of aleurone cell walls.

43 PARTICLE ACCELERATORS↗

Synchrotron Powder X-ray Diffraction Study of the Structure and Dehydration Behavior of Palygorskite

Rietveld refinements using synchrotron powder X-ray diffraction data were used to study the crystal structure and dehydration behavior of pure monoclinic palygorskite samples from Korea and Alaska. The 300 and 100 K palygorskite structures in air compare well with previous models but provide additional details about zeolitic H2O sites and reveal that the Al atoms are ordered into the inner M2 octahedral sites and the Mg cations into the M3 sites at the edges of the tunnels. Real-time, temperature-resolved synchrotron powder X-ray diffraction data and Rietveld refinements were used to investigate the monoclinic palygorskite structure from 300 to 1400 K (in air). Rietveld refinements showed that most of the zeolitic H2O is lost by 425 K, accompanied by a decrease in the unit-cell volume of 1.3%, primarily owing to a decrease in the a unit-cell parameter and an increase in the ? angle. The structurally bound H2O is lost in two stages, at temperature intervals of 475-540 and 580-725 K. Above 825 K in air a portion of the Korean sample transformed to a folded structure; the Alaskan sample folded at 575 K under vacuum. A structure model was refined for the folded structure. At 1015 K for the sample heated in air, ?-quartz diffraction peaks appeared and increased in intensity as heating continued to the maximum temperature. Cristobalite formed above 1050 K, along with a small amount of clinoenstatite, and both phases persisted to the maximum temperature studied.

36 MATERIALS SCIENCE↗

NSLS-II: Nonlinear Model Calibration for Synchrotrons

This tech note is essentially a summary of a lecture we delivered to the Acc. Phys. Journal Club Apr, 2010. However, since the estimated accuracy of these methods has been naive and misleading in the field of particle accelerators, i.e., ignores the impact of noise, we will elaborate on this in some detail. A prerequisite for a calibration of the nonlinear Hamiltonian is that the quadratic part has been understood, i.e., that the linear optics for the real accelerator has been calibrated. For synchrotron light source operations, this problem has been solved by the interactive LOCO technique/tool (Linear Optics from Closed Orbits). Before that, in the context of hadron accelerators, it has been done by signal processing of turn-by-turn BPM data. We have outlined how to make a basic calibration of the nonlinear model for synchrotrons. In particular, we have shown how this was done for LEAR, CERN (antiprotons) in the mid-80s. Specifically, our accuracy for frequency estimation was {approx} 1 x 10{sup -5} for 1024 turns (to calibrate the linear optics) and {approx} 1 x 10{sup -4} for 256 turns for tune footprint and betatron spectrum. For a comparison, the estimated tune footprint for stable beam for NSLS-II is {approx}0.1. Since the transverse damping time is {approx}20 msec, i.e., {approx}4,000 turns. There is no fundamental difference for: antiprotons, protons, and electrons in this case. Because the estimated accuracy for these methods in the field of particle accelerators has been naive, i.e., ignoring the impact of noise, we have also derived explicit formula, from first principles, for a quantitative statement. For e.g. N = 256 and 5% noise we obtain {delta}{nu} {approx} 1 x 10{sup -5}. A comparison with the state-of-the-arts in e.g. telecomm and electrical engineering since the 60s is quite revealing. For example, Kalman filter (1960), crucial for the: Ranger, Mariner, and Apollo (including the Lunar Module) missions during the 60s. Or Claude Shannon et al since the 40s for that matter. Conclusion: what's elementary in the latter is considered 'advanced', if at all, in the former. It is little surprise then that published measurements typically contains neither error bars (for the random errors) nor estimates for the systematic in the former discipline. We have also showed how to estimate the state space by turn-by-turn data from two adjacent BPMs. And how to improve the resolution of the nonlinear resonance spectrum by Fourier analyzing the linear action variables instead of the betatron motion. In fact, the state estimator could be further improved by adding a Kalman filter. For transparency, we have also summarized on how these techniques provide a framework- and method for a TQM (Total Quality Management) approach for the main ring. Of course, to make the ($2.5M) turn-by-turn data acquisition system that is being implemented (for all the BPMs) useful, a means ({approx}10% contingency for the BPM system) to drive the beam is obviously required.

43 PARTICLE ACCELERATORS↗

Understanding Electrocatalytic Pathways in Low and Medium Temperature Fuel Cells: Synchrotron-based In Situ X-Ray Absorption Spectroscopy

Over the last few decades, researchers have made significant developments in producing more advanced electrocatalytic materials for power generation applications. For example, traditional fuel cell catalysts often involve high-priced precious metals such as Pt. However, in order for fuel cells to become commercially viable, there is a need to reduce or completely remove precious metal altogether. As a result, a myriad of novel, unconventional materials have been explored such as chalcogenides, porphyrins, and organic-metal-macrocycles for low/medium temperature fuel cells as well as enzymatic and microbial fuel cells. As these materials increasingly become more complex, researchers often find themselves in search of new characterization methods, especially those which are allow in situ and operando measurements with element specificity. One such method that has received much attention for analysis of electrocatalytic materials is X-ray absorption spectroscopy (XAS). XAS is an element specific, core level absorption technique which yields structural and electronic information. As a core electron method, XAS requires an extremely bright source, hence a synchrotron. The resulting intensity of synchrotron radiation allow for experiments to be conducted in situ, under electrochemically relevant conditions. Although a bulk-averaging technique requiring rigorous mathematical manipulation, XAS has the added benefit that it can probe materials which possess no long range order. This makes it ideal to characterize nano-scale electrocatalysts. XAS experiments are conducted by ramping the X-ray photon energy while measuring absorption of the incident beam the sample or by counting fluorescent photons released from a sample due to subsequent relaxation. Absorption mode XAS follows the Beer-Lambert Law, {mu}x = log(I{sub 0}/I{sub t}) (1) where {mu} is the absorption coefficient, x is the sample thickness and I{sub 0} and I{sub t} are the intensities of the incident and transmission beams respectively. When the energy of the incident X-rays exceed the electron binding energy (E{sub 0}) of the element under investigation, the electron is ejected from the core to available excited states in the form of a photoelectron with kinetic energy: E{sub k} = h? - E{sub 0} (2) with, E{sub k} being the kinetic energy of the released photoelectron and h? the energy of the incident beam. In general, the X-ray absorption spectrum is broken down into two distinct energy regions: the X-ray absorption near-edge structure or XANES (-50eV {le} E{sub 0} {le} 50eV) and the extended X-ray absorption fine-structure or EXAFS (50eV {le} E{sub 0} {le} {approx}1000eV). The XANES region is dominated by low-energy photoelectrons which undergo multiple scattering events. As such, it can reveal information about oxidation state, local symmetry, electronic structure, and the extent of oxidation of a material. Due to this complex multiple scattering, there is no simple XANES equation to describe it quantitatively. However, recent advancements in computers and the evolution of numerical methods such as the FEFF code have made possible reliable XANES simulations. Photoelectrons in the EXAFS region have high enough E{sub k} to undergo primarily single back-scattering events. These back-scattered photoelectrons interfere with the outgoing photoelectrons, causing the oscillations in the absorption spectrum. Using the previously developed EXAFS equations it is now possible to model EXAFS data to determine coordination numbers, bond distances, and mean-square disorder (commonly referred to as Debye-Waller factor). EXAFS data is often shown by Fourier Transforming KSpace into distance, r, space where the total magnitude is plotted against the radial coordinates. This allow for easy qualitative comparison of samples. Employing EXAFS on nanoscale materials has the added advantage that it can quantitatively illustrate changes in atom-atom coordination, which can be related to particle size or morphology. Overall this technique enables the measurement of both bulk and surface adsorbed species with element specificity under actual electrochemical operating conditions. Thus this represents the one of the most powerful methods to understand the exact role of the reaction center and degradation processes such as sintering and corrosion.

30 DIRECT ENERGY CONVERSION↗

Synchrotron Radiation Circular Dichroism (SRCD) Spectroscopy - An Enhanced Method for Examining Protein Conformations and Protein Interactions

CD (circular dichroism) spectroscopy is a well-established technique in structural biology. SRCD (synchrotron radiation circular dichroism) spectroscopy extends the utility and applications of conventional CD spectroscopy (using laboratory-based instruments) because the high flux of a synchrotron enables collection of data at lower wavelengths (resulting in higher information content), detection of spectra with higher signal-to-noise levels and measurements in the presence of absorbing components (buffers, salts, lipids and detergents). SRCD spectroscopy can provide important static and dynamic structural information on proteins in solution, including secondary structures of intact proteins and their domains, protein stability, the differences between wild-type and mutant proteins, the identification of natively disordered regions in proteins, and the dynamic processes of protein folding and membrane insertion and the kinetics of enzyme reactions. It has also been used to effectively study protein interactions, including protein-protein complex formation involving either induced-fit or rigid-body mechanisms, and protein-lipid complexes. A new web-based bioinformatics resource, the Protein Circular Dichroism Data Bank (PCDDB), has been created which enables archiving, access and analyses of CD and SRCD spectra and supporting metadata, now making this information publicly available. To summarize, the developing method of SRCD spectroscopy has the potential for playing an important role in new types of studies of protein conformations and their complexes.

59 BASIC BIOLOGICAL SCIENCES↗

First Beam Measurements with the LHC Synchrotron Light Monitors

The continuous monitoring of the transverse sizes of the beams in the Large Hadron Collider (LHC) relies on the use of synchrotron radiation and intensified video cameras. Depending on the beam energy, different synchrotron light sources must be used. A dedicated superconducting undulator has been built for low beam energies (450 GeV to 1.5 TeV), while edge and centre radiation from a beam-separation dipole magnet are used respectively for intermediate and high energies (up to 7 TeV). The emitted visible photons are collected using a retractable mirror, which sends the light into an optical system adapted for acquisition using intensified CCD cameras. This paper presents the design of the imaging system, and compares the expected light intensity with measurements and the calculated spatial resolution with a cross calibration performed with the wire scanners. Upgrades and future plans are also discussed.

43 PARTICLE ACCELERATORS↗