Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Iodine Removal in the DFLAW Flow-Sheet

In support of the WTP project, off-gas system and regulatory testing has been conducted previously on the DM1200 pilot melter equipped with a prototypical off-gas system installed at The Catholic University of America’s Vitreous State Laboratory (VSL). During the regulatory tests, an AC-S test bed filled with Kombisorb BAT 37 was included in the prototypical off-gas system and evaluated for response to HLW and LAW exhaust streams. Offline testing and small-scale testing of that media were also conducted. Testing demonstrated that a temperature rise occurred in the activated carbon media when water vapor was first introduced to virgin Kombisorb BAT 37, in response to high nitrogen oxide concentrations, and in response to the presence of organic compounds. Conditioning of the test bed by gradually increasing the NOx concentration prior to the introduction of organics was found to be an important operational strategy for preventing larger temperature excursions. However, no mercury was present in the exhaust stream during DM1200 testing and therefore comparable test data for mercury removal efficiency or temperature response of the carbon media in the presence of mercury were not collected in the DM1200 tests. In view of the need for data on mercury removal performance, BNI contracted with Atkins and the VSL to install and operate a suitable test system at VSL to collect the required data. That testing was designed to assess the performance of Kombisorb BAT-37 and the guard bed material, Sofnolime RG, for simulated melter exhaust streams that contain the highest concentrations of mercury, nitrogen oxides, acid gases, and organic compounds expected in WTP LAW melter exhaust. During shakedown testing with the new system, however, it became evident that a number of issues with Sofnolime RG as the guard bed material would render it unsuitable for this application. BNI subsequently determined that the guard bed was redundant for removal of acid gases since they could be adequately removed by the SBS and WESP. However, since the guard bed material was also credited with significant iodine removal , there was a need for a replacement material that would adequately perform that role. BNI identified several candidate media but performance data in gas compositions that are representative of the WTP LAW off-gas were not available. Accordingly, there was a need to test and evaluate the performance of these candidate media prior to performing the originally-planned tests. To that end, small scale tests were conducted to assess the performance of various adsorbents in simulated melter exhaust streams that contain mercury, iodine, nitrogen oxides, acid gases, and acetonitrile, which are expected to be present in WTP LAW melter exhaust.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TREATABILITY TEST REPORT FOR THE REMOVAL OF CHROMIUM FROM GROUNDWATER AT 100-D AREA USING ELECTROCOAGULATION

The U.S. Department of Energy (DOE) has committed to accelerate cleanup of contaminated groundwater along the Columbia River. The current treatment approach was driven by a series of Interim Action Records of Decision (IAROD) issued in the mid-1990s. Part of the approach for acceleration involves increasing the rate of groundwater extraction for the chromium plume north of the 100-D Reactor and injecting the treated water in strategic locations to hydraulically direct contaminated groundwater toward the extraction wells. The current treatment system uses ion exchange for Cr(VI) removal, with off-site regeneration of the ion exchange resins. Higher flow rates will increase the cost and frequency of ion exchange resin regeneration; therefore, alternative technologies are being considered for treatment at high flow rates. One of these technologies, electrocoagulation (EC), was evaluated through a pilot-scale treatability test. The primary purpose of the treatability study was to determine the effectiveness of Cr(VI) removal and the robustness/implementability of an EC system. Secondary purposes of the study were to gather information about derivative wastes and to obtain data applicable to scaling the process from the treatability scale to full-scale. The treatability study work plan identified a performance objective and four operational objectives. The performance objective for the treatability study was to determine the efficiency (effectiveness) of hexavalent chromium removal from the groundwater, with a desired concentration of {le} 20 micrograms per liter ({micro}g/L) Cr(VI) in the effluent prior to re-injection. Influent and effluent total chromium and hexavalent chromium data were collected using a field test kit for multiple samples per week, and from off-site laboratory analysis of samples collected approximately monthly. These data met all data quality requirements. Two of three effluent chromium samples analyzed in the off-site (that is, fixed) laboratory met the performance objective during the continuous operational testing. Effluent hexavalent chromium analyzed by the field laboratory met the performance goal in over 90 percent of the samples. All effluent hexavalent chromium samples during the batch testing with high influent hexavalent chromium concentrations ({approx}2000 {micro}g/L) met the performance objective. Although the EC system was able to meet the performance goal, it must be noted that it was not uncommon for the system to be operated in recycle mode to achieve the performance goal. The EC unit was sometimes, but not always, capable of a single pass treatment efficiency high enough to meet the performance goal, and recycling water for multiple treatment passes was effective. An operational objective was to determine the volume and composition of the waste streams to enable proper waste designation. The toxicity characteristic leaching procedure (TCLP) concentrations, pH, and free liquids were determined for solid material from the EC electrodes (mechanically removed scale), the filter press, and the tank bottoms for the effluent and waste collector tanks. These data met all data quality requirements. All solid-phase secondary waste streams were found to be below the TCLP limits for the toxicity characteristic, and a pH value within the limits for the corrosivity characteristic. Out of three samples, two (one of scale from the EC unit and one from filter press solids) failed the free liquid (paint filter) test, which is one of the acceptability criteria for Hanford's Environmental Restoration Disposal Facility (ERDF). The solid-phase waste generation rate was about 0.65-gallon of solid waste per 100 gallons of water treated. It is concluded that the solid-phase secondary waste generated from this technology under the conditions at the test site will meet the toxicity and corrosivity criteria for disposal. It is also concluded that with engineering and/or operational improvements, a solid-phase secondary waste could be produced that would meet the free liquid disposal requirements. The second operational objective was to assess the operational reliability and safety of the system. For the continuous operations testing period from July 23 to September 12,2007, the system was not able to operate unattended. An extensive period of startup and adjustment preceded continuous operations, but was unsuccessful in providing a suitable and robust operating condition. Primary operational reliability problems were related to the sensitivity of the solid separation process to operational conditions such that a robust operating procedure (for example, chemical dosage) was not identified during the treatability test. Poor solids separation and high effluent iron concentrations also led to operational difficulties associated with injection well fouling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress and plan of KSTAR plasma control system upgrade

The plasma control system (PCS) has been one of essential systems in annual KSTAR plasma campaigns: starting from a single-process version in 2008, extensive upgrades are done through the previous 7 years in order to achieve major goals of KSTAR performance enhancement. Here, major implementations are explained in this paper. In consequences of successive upgrades, the present KSTAR PCS is able to achieve ~48 s of 500 kA plasma pulses with full real-time shaping controls and real-time NB power controls. It has become a huge system capable of dealing with 8 separate categories of algorithms, 26 actuators directly controllable during the shot, and real-time data communication units consisting of +180 analog channels and +600 digital input/outputs through the reflective memory (RFM) network. The next upgrade of the KSTAR PCS is planned in 2015 before the campaign. An overview of the upgrade layout will be given for this paper. The real-time system box is planned to use the CERN MRG-Realtime OS, an ITER-compatible standard operating system. New hardware is developed for faster real-time streaming system for future installations of actuators/diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A stochastic operational model for controlling electric vehicle charging to provide frequency regulation

The charging of battery electric vehicles (BEVs) is a potential source of flexibility and ancillary services to power systems. Herein this paper proposes a two-stage stochastic problem that can be used to optimize the charging of BEVs in a public charging station to provide frequency regulation and energy arbitrage. The model also co-optimizes the use of distributed energy resources, including battery energy storage and photovoltaic solar panels. We demonstrate the performance of the proposed model using a case study based on the Central-Ohio region. The case study shows that proper management of flexibility in BEV charging can provide high-quality frequency regulation services, which is also of significant financial value to the station operator. As such, the modeling methodology that we propose here can further accelerate the adoption of BEVs. This is because the value streams generated by the provision of frequency regulation can reduce the cost of BEV ownership and the net cost of owning and operating a public BEV-charging station.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Catalytic dehydration of biomass derived 1-propanol to propene over M-ZSM-5 (M = H, V, Cu, or Zn)

Here, the impetus to explore biomass derived chemicals arises from a desire to enable renewable and sustainable commodity chemicals. To this end, we report catalytic production of propene, a building-block molecule, from 1-propanol. We found that zeolite catalysts are quite versatile and can produce propene at or below 230 C with high selectivity. Increasing the reaction temperature above 230 C shifted product selectivity towards C4+ hydrocarbons. Cu-ZSM-5 was found to exhibit a broader temperature window for high propene selectivity and could function at higher 1-propanol space velocities than H-ZSM-5. A series of experiments with 1-propan(ol-D) showed deuterium incorporation in the hydrocarbon product stream including propene suggesting that hydrocarbon pool type pathway might be operational concurrent with dehydration to produce C4+ hydrocarbons. Diffuse reflectance infra-red spectroscopy of 1-propanol and 1-propan(ol-D) over Cu-ZSM-5 in combination with deuterium labeling experiments suggest that deuterium incorporation occurs in two steps. Incorporation of deuterium occurs post dehydration via exchange with the partially deuterated catalyst surface.

09 BIOMASS FUELS↗

Effect of syngas composition and CO{sub 2}-diluted oxygen on performance of a premixed swirl-stabilized combustor

Future energy systems based on gasification of coal or biomass for co-production of electrical power and fuels may require gas turbine operation on unusual gaseous fuel mixtures. In addition, global climate change concerns may dictate the generation of a CO{sub 2} product stream for end-use or sequestration, with potential impacts on the oxidizer used in the gas turbine. In this study the operation at atmospheric pressure of a small, optically accessible swirl-stabilized premixed combustor, burning fuels ranging from pure methane to conventional and H{sub 2}-rich and H{sub 2}-lean syngas mixtures is investigated. Both air and CO{sub 2}-diluted oxygen are used as oxidizers. CO and NOx emissions for these flames have been determined from the lean blowout limit to slightly rich conditions {phi} about 1.03). In practice, CO{sub 2}-diluted oxygen systems will likely be operated close to stoichiometric conditions to minimize oxygen consumption while achieving acceptable NOx performance. The presence of hydrogen in the syngas fuel mixtures results in more compact, higher temperature flames, resulting in increased flame stability and higher NOx emissions. Consistent with previous experience, the stoichiometry of lean blowout decreases with increasing H{sub 2} content in the syngas. Similarly, the lean stoichiometry at which CO emissions become significant decreases with increasing H{sub 2} content. For the mixtures investigated, CO emissions near the stoichiometric point do not become significant until {phi} > 0.95. At this stoichiometric limit, CO emissions rise more rapidly for combustion in O{sub 2}-CO{sub 2} mixtures than for combustion in air.

01 COAL, LIGNITE, AND PEAT↗

High-temperature carbon dioxide capture in a porous material with terminal zinc hydride sites

Carbon capture can mitigate point-source carbon dioxide (CO 2 ) emissions, but hurdles remain that impede the widespread adoption of amine-based technologies. Capturing CO 2 at temperatures closer to those of many industrial exhaust streams (>200°C) is of interest, although metal oxide absorbents that operate at these temperatures typically exhibit sluggish CO 2 absorption kinetics and instability to cycling. Here, in this study, we report a porous metal–organic framework featuring terminal zinc hydride sites that reversibly bind CO 2 at temperatures above 200°C—conditions that are unprecedented for intrinsically porous materials. Gas adsorption, structural, spectroscopic, and computational analyses elucidate the rapid, reversible nature of this transformation. Extended cycling and breakthrough analyses reveal that the material is capable of deep carbon capture at low CO 2 concentrations and high temperatures relevant to postcombustion capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid secondary waste testing for maintenance of the Hanford Integrated Disposal Facility Performance Assessment - FY 2017

The Waste Treatment and Immobilization Plant (WTP) at Hanford is being constructed to treat 56 million gallons of radioactive waste currently stored in underground tanks at the Hanford site. Operation of the WTP will generate several solid secondary waste (SSW) streams including used process equipment, contaminated tools and instruments, decontamination wastes, high-efficiency particulate air filters (HEPA), carbon adsorption beds, silver mordenite iodine sorbent beds, and spent ion exchange resins (IXr) all of which are to be disposed in the Integrated Disposal Facility (IDF). An applied research and development program was developed using a phased approach to incrementally develop the information necessary to support the IDF PA with each phase of the testing building on results from the previous set of tests and considering new information from the IDF PA calculations. This report contains the results from the exploratory phase, Phase 1 and preliminary results from Phase 2. Phase 3 is expected to begin in the fourth quarter of FY17.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ammonia Remediation in Hanford WTP Liquid Secondary Waste

The Hanford Site Effluent Treatment Facility (ETF) treats aqueous waste streams; some of these waste streams have high concentrations of ammonium ion. When the WTP begins operation the ETF LSW is slated to be stabilized by grouting prior to disposal. During stabilization of such waste by grouting the pH would rise considerably, leading to the evolution of ammonia gas. Such an ammonia release would require engineering controls to assure worker and environmental safety. The primary objective of this work was to perform a parametric study of the efficacy of ammonia destruction from solution using sodium nitrite addition under varying conditions that expands upon previous work.

54 ENVIRONMENTAL SCIENCES↗

Flanged Tritium Waste Containers: Background and Current Path to Disposal

The MLLW Flanged Tritium Waste Container (FTWC) Project has been operational since 2007 when, during an audit of the FTWC waste stream, it was determined that four FTWC containers contained lead in amounts greater than LDR treatment standards. From June to August of 2007, four FTWC containers were shipped to TA-54 for disposal as LLW from WETF. The contents of the FTWCs were characterized as high activity LLW and were thought to be in compliance with LANL's Waste Acceptance Criteria (WAC). During the packaging of these FTWC's, 36 intact squib valves (aka actuators), containing detonated squibs were included with the waste stream After being transported to TA-54 Area G, it was determined that the explosive used in some of the squibs was Normal Lead Styphnate (NLS). A recharacterization of the entire contents in the FTWC's was performed with the conclusion that the squib valves exhibited the RCRA toxic characteristic for Lead (D008), thus resulting in the contents of the FTWCs being reclassified as a Mixed LLW.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Potential Disposition Options for a Salt Fueled Molten Salt Reactor At the INL (A White Paper)

The molten salt reactor (MSR) design concept has been the focus of significant research and development efforts, both in the U.S. and around the world. There are generally two types of MSRs, salt fueled MSRs that have the fuel dissolved within the salt and solid fueled MSRs that only use the molten salt as a coolant. The range of conceptual designs and the flexibility of operations of MSRs results in a wide range of potential waste streams from salt fueled MSRs; all of which require safe and secure storage and eventual disposition. This white paper will 1) survey the range of salt fueled MSR designs, 2) recognize the implications of design, on the resulting waste streams, and 3) identify the definitions and regulations that apply to the safe and secure management, storage, and disposal of these streams. Research in MSR waste streams is young and the focus of intense research that requires more funding and time to become mature enough to fully support design decisions. Once a specific design is selected, a more detailed management and disposition effort must be performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Developing and Managing Data Acquisition Software Using Spack

The Data Acquisition systems of particle physics experiments regularly push the boundaries of high-throughput computing, demanding low-latency collection of data from thousands of devices, collating data into time-sliced events, processing these events and making trigger decisions, and writing the selected data streams to disk. To accomplish these tasks, the DAQ Engineering and Operations department at Fermilab leverages multiple software libraries and builds reusable DAQ frameworks on top. These libraries must be delivered in well-defined bundles and are thoroughly tested for compatibility and functionality before being deployed to live detectors. We have several techniques used to ensure that a consistent set of dependencies can be delivered and re-created at need. We must also support active development of DAQ software components, ideally in an environment as close as possible to that of the detectors. This development often occurs across multiple packages which have to be built in concert and features tested in a consistent and reproducible manner. I will present our scheme for accomplishing these goals using Spack environments, bundle packages, and Github Actions-based CI.

Flumerfelt, Eric [Fermilab]↗

Single-pass parallel prefix scan with dynamic look back

One embodiment of the present invention performs a parallel prefix scan in a single pass that incorporates variable look-back. A parallel processing unit (PPU) subdivides a list of inputs into sequentially-ordered segments and assigns each segment to a streaming multiprocessor (SM) included in the PPU. Notably, the SMs may operate in parallel. Each SM executes write operations on a segment descriptor that includes the status, aggregate, and inclusive-prefix associated with the assigned segment. Further, each SM may execute read operations on segment descriptors associated with other segments. In operation, each SM may perform reduction operations to determine a segment-wide aggregate, may perform look-back operations across multiple preceding segments to determine an exclusive-prefix, and may perform a scan seeded with the exclusive prefix to generate output data. Advantageously, the PPU performs one read operation per input, thereby reducing the time required to execute the prefix scan relative to prior-art parallel implementations.

Merrill, Duane↗

LCA of Carbon Capture Retrofit Using the “Petra Nova Style” Model - LCAXVIII

This work was presented at the American Center for Life Cycle Assessment (ACLCA) LCAXVIII Conference in Fort Collins, CO on September 26, 2018. This analysis compares the life cycle environmental impacts for an amine-based capture retrofit with an external co-gen source providing the utility inputs for capture compared to a more traditional retrofit in which the plant/unit output is de-rated with the utility inputs for operating the capture system coming directly from the plant. One of the major differences between the designs is that in the case of the external co-gen unit, the combustion emissions associated with operating the capture unit are not part of the flue gas stream that is directed to the capture unit. Another unique consideration in this analysis is the inclusion of the upstream natural gas life cycle in the boundaries of the co-gen retrofit.

Krynock, Michelle↗

Learning method and system for separating independent and dependent attacks

Streams of monitoring node signal values over time, representing a current operation of the industrial asset, are used to generate current monitoring node feature vectors. Each feature vector is compared with a corresponding decision boundary separating normal from abnormal states. When a first monitoring node passes a corresponding decision boundary, an attack is detected and classified as an independent attack. When a second monitoring node passes a decision boundary, an attack is detected and a first decision is generated based on a first set of inputs indicating if the attack is independent/dependent. From the beginning of the attack on the second monitoring node until a final time, the first decision is updated as new signal values are received for the second monitoring node. When the final time is reached, a second decision is generated based on a second set of inputs indicating if the attack is independent/dependent.

97 MATHEMATICS AND COMPUTING↗

Hydraulic Properties of Grout Monoliths Containing Organic Ion Exchange Resin - 18369

The Waste Treatment and Immobilization Plant (WTP) at Hanford is being constructed to treat 56 million gallons of radioactive waste currently stored in underground tanks at the Hanford site. Operation of the WTP will generate several solid secondary waste (SSW) streams including spent spherical resorcinol formaldehyde cation exchange resin (IXr). The current plan for safe disposal of IXr is solidification in cementitious material (CM) typically comprised of cement, fly ash and blast furnace slag. Three CM formulations were tested to stabilize IXr for long-term land disposal. Two IXr loading rates, 0.1 and 0.3 v/v IXr:grout were used with the three CM formulations to prepare simulated waste form monoliths for hydraulic property testing. Following curing, the monoliths were removed from molds and tested to determine saturated hydraulic conductivity (K{sub sat}) and water retention properties. K{sub sat} was measured using a standard flexible permeameter method ASTM D-5084-10. A constant vapor pressure (CVP) method was used to determine van Genuchten parameters for desorption moisture retention curves for each of the SSW grout formulations. For the CVP method, vacuum saturated, intact wafers approximately 1.25 cm thick were placed above a saturated salt solution inside a sealed container for equilibration. Each saturated salt solution has an associated vapor pressure related to relative humidity in the container. Visual examination and three-dimensional x-ray micro computed tomography (μCT) indicated that the IXr was uniformly distributed in the cured waste form. Saturated hydraulic conductivity was within the range previously reported by Flach et al. in a study of the hydraulic properties of 98 pastes and grouts. The solidification of IXr in CM resulted in a waste form with water retention properties similar to cementitious pastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 120: Roundtable: Waste Management - Energy Facilities Contractor Operating Group (EFCOG WM)

This Roundtable focused on the WM EFCOG working group as they met to discuss a variety of issues of importance to US DOE waste management operations. The purpose of the WM EFCOG is to seek out and promote the best management and operating practices, cost effective technologies and disposal options for all waste streams generated at US DOE facilities whether destined for US DOE or commercial facilities. Each site representative provided a radioactive waste management lessons learned briefing. Panelists with presentations: Savannah River Site (SRS) Solid Waste Program Update (Kerri Crawford); Idaho Clean-up Project Status (Frederick Hughes); West Valley Demonstration Project Update - EFCOG Waste Management Working Group (John Rendall); Key Project Challenges and Successes (Kalli Shupe); EFCOG WMWG Challenging Waste Subgroup Update (Tammy Monday); CH TRU Difficult Waste Stream Processing Challenges (Daniel Pancake); Argonne Building 350 Clean-up Success Using Effective Work Control (Daniel Dilday); Problematic Waste Streams on the Oak Ridge Reservation (John Wrapp)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗