Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software differences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Validation testing of the Canberra mobile Feed Roll Assay system - 15404

Japanese farmers grow various grasses as feed for cattle. These are rolled up and sealed for future use. Canberra has created a special truck to monitor these Feed Rolls, called 'Feed Roll Assay System [FRAS]'. On the bed of the truck is the shield containing a large NaI detector. The detector is 3x5x16'' in size, the same size as used in the Canberra FastScan Whole Body Counter. The detector is also LED-stabilized, to keep the gain constant under the wide range of temperature variations expected for this outdoor measurement instrument. The Canberra Osprey digital MCA is connected to the detector. The detector and the MCA are housed in a water proof box, which is surrounded on the bottom and all sides by a 15 cm thick steel shield. A portion of the shield at the top is open where the detector can view the Feed Rolls placed there. A single ethernet cable goes to a laptop PC which provides power to the MCA and detector, and also transmits the signal to the PC. The system was calibrated using MCNP for a variety of different densities, and Feed Roll sizes. The Japanese version of the Canberra Genie software is used to analyze the spectra and compute the Bq/kg concentration of the Feed Roll. The shielding is sufficient so that at a 5 uSv/hr background dose rate, no Cs-137 or Cs-134 peaks were detected in a 1 hour count. Measurements were performed in 0.2 uSv/hr dose rate, using uncontaminated Feed Rolls at various counting times. The MDA for Cs-137 was 11.9 Bq/kg at 30 seconds, 8.2 Bq/kg for 60 seconds, and 1.1 Bq/kg at 3600 seconds count time. The relative measurement uncertainty of the FRAS measurements was 9.4 to 13%, as compared to assays of samples extracted [30-45%] and in-situ Ge measurements [6.0 - 7.1%]. The FRAS measurement results have considerably better precision than measurements of samples extracted from the Feed Rolls, and are much faster than the in-situ Ge measurements and have just about the same uncertainty. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GridOPTICS/GridPACK

GridPACK is a software framework consisting of a set of modules designed to simplify the development of programs that model the power grid and run on parallel, high performance computing platforms. It also contains several fully developed applications, including powerflow, dynamic simulation, state estimation, Kalman filter analysis (dynamic state estimation), contingency analysis and real time path rating. These applications can be used either standalone or as components in more complicated workflows that combine several different types of application together. The framework modules are available as a combination of libraries and software templates and consist of components for setting up and distributing power grid networks, support for modeling the behavior of individual buses and branches in the network, converting the network models to the corresponding algebraic equations, and parallel routines for manipulating and solving large algebraic systems. The framework also contains a module for distributing tasks evenly amongst computing resources, even if individual tasks vary widely in their execution times. Additional modules support input and output, basic statistical analysis of contingency based calculations, distributed data structures, as well as basic profiling and error management.

Palmer, Bruce↗

Qualitative and quantitative validation of the SINBAD code on complex HPGe gamma-ray spectra

Radionuclides identification and quantification is a serious concern for many applications as safety or security of nuclear power plant or fuel cycle facility, CBRN risk identification, environmental radioprotection and waste measurements. High resolution gamma-ray spectrometry based on HPGe detectors is a performing solution for all these topics. During last decades, a great number of software has been developed to improve gamma spectra analysis. However, some difficulties remain in the analysis when photoelectric peaks are folded together with a high ratio between theirs amplitudes, when the Compton background is much larger compared to the signal of a single peak and when spectra are composed of a great number of peaks. This study deals with the comparison between conventional methods in radionuclides identification and quantification and the code called SINBAD ('Spectrometrie par Inference Non parametrique Bayesienne Deconvolutive'). For many years, SINBAD has been developed by CEA LIST for unfolding complex spectra from HPGe detectors. Contrary to conventional methods using fitting procedures, SINBAD uses a probabilistic approach with Bayesian inference to describe spectrum data. This conventional fitting method founded for example in Genie 2000 is compared with the nonparametric SINBAD approach regarding some key figures of merit as the peak centroid evaluation (identification) and peak surface evaluation (quantification). Unfriendly cases are studied for nuclides detection with closed gamma-rays energies and high photoelectric peak intensity differences. Tests are performed with spectra from the International Atomic Energy Agency (IAEA) for gamma spectra analysis software benchmark and with spectra acquired at the laboratory. Results show that SINBAD and Genie 2000 performances are quite similar with sometimes best results for SINBAD with the important difference that to achieve same performances the nonparametric method is user-friendly compared to the conventional method which need an expert parameters adjustment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

UQpy: A general purpose Python package and development environment for uncertainty quantification

In this paper, we present the UQpy software toolbox, an open-source Python package for general uncertainty quantification (UQ) in mathematical and physical systems. The software serves as both a user-ready toolbox that includes many of the latest methods for UQ in computational modeling and a convenient development environment for Python programmers advancing the field of UQ. The paper presents an introduction to the software's architecture and existing capabilities, divided in the code in a set of modules centered around different UQ tasks such as sampling methods, generation of random processes and random fields, probabilistic inverse modeling, reliability analysis, surrogate modeling, and active learning. The paper also highlights the importance of the RunModel module, which is used to drive simulations in the uncertainty analyses performed in UQpy. This module conveniently allows the user to define computational models directly in Python, or to run simulations from a third-party software in serial or in parallel. To illustrate the various capabilities, two examples are tracked throughout the paper and analyzed repeatedly for various UQ tasks. The first is a Python model solving a nonlinear structural dynamics problem, used to illustrate UQpy's capabilities in sampling and forward propagation of high dimensional random vectors (stochastic processes), and probabilistic inference. The second model is a third-party Abaqus finite element model solving the thermomechanical response of a beam structure. This example is used to illustrate UQpy's capabilities in variance reduction sampling techniques, reliability analysis, surrogate modeling and active learning techniques.

97 MATHEMATICS AND COMPUTING↗

Simulation of double buffer layer on CIGS solar cell with SCAPS software

In a CIGS thin film solar cell, the buffer layer is interposed between the absorber layer and the window layer, which plays an important role in interface electricity. CdS is often used as a buffer layer in CIGS cells. Beside the toxicity of Cd, the main drawback of CdS is its relatively narrow band gap (2.4 eV), which can lead to the current loss due to parasitic absorption. In order to reduce the use of CdS, we try other buffer layers instead of CdS and optimize buffer layer structure. Numerical simulation has been used to explore the effect of different buffer layer materials (CdS and ZnSe) on the performance of CuInGaSe{sub 2} solar cells with SCAPS-1D software. The main photovoltaic parameters of the analog device: open circuit voltage, short circuit current density, fill factor and conversion efficiency (η) were compared and analyzed. The results show that different buffer materials and thickness have great influence on the performance of the cell. In this simulation, CdS buffer layer was replaced by ZnSe material, which has a wider band gap. However, the efficiency of this kind of cell is lower than that of CIGS device with CdS buffer layer because of the bad energy band alignment. In order to improve the short-wave absorption and the efficiency of CIGS cell, we simulated a novel CdS/ZnSe double buffer layer structure. The efficiency of the optimized cell with double buffer layer increases from 18.47% (conventional cell with the same CdS buffer layer thickness) to 19.01%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AMReX: a framework for block-structured adaptive mesh refinement

AMReX is a C++ software framework that supports the development of block-structured adaptive mesh refinement (AMR) algorithms for solving systems of partial differential equations (PDEs) with complex boundary conditions on current and emerging architectures. AMR reduces the computational cost and memory footprint compared to a uniform mesh while preserving the local descriptions of different physical processes in complex multiphysics algorithms. Current AMReX-based application codes span a number of areas, including atmospheric modeling, astrophysics, combustion, cosmology, fluctuating hydrodynamics, multiphase flows, and particle accelerators. In particular, the AMReX-Astro GitHub repository holds a number of astrophysical modeling tools based on AMReX. The origins of AMReX trace back to the BoxLib software framework. AMReX supports a number of different time-stepping strategies and spatial discretizations. Solution strategies supported by AMReX range from level-by-level approaches (with or without subcycling in time) with multilevel synchronization to full-hierarchy approaches, and any combination thereof. User-defined kernels that operate on patches of data can be written in C++ or Fortran; there is also a Fortran-interface functionality which wraps the core C++ data structures and operations in Fortran wrappers so that an application code based on AMReX can be written entirely in Fortran.

97 MATHEMATICS AND COMPUTING↗

WE-H-207A-07: Image-Based Versus Atlas-Based Internal Dosimetry

Purpose: Monte Carlo (MC) simulation is known as the gold standard method for internal dosimetry. It requires radionuclide distribution from PET or SPECT and body structure from CT for accurate dose calculation. The manual or semi-automatic segmentation of organs from CT images is a major obstacle. The aim of this study is to compare the dosimetry results based on patient’s own CT and a digital humanoid phantom as an atlas with pre-specified organs. Methods: SPECT-CT images of a 50 year old woman who underwent bone pain palliation with Samarium-153 EDTMP for osseous metastases from breast cancer were used. The anatomical date and attenuation map were extracted from SPECT/CT and three XCAT digital phantoms with different BMIs (i.e. matched (38.8) and unmatched (35.5 and 36.7) with patient’s BMI that was 38.3). Segmentation of patient’s organs in CT image was performed using itk-SNAP software. GATE MC Simulator was used for dose calculation. Specific absorbed fractions (SAFs) and S-values were calculated for the segmented organs. Results: The differences between SAFs and S-values are high using different anatomical data and range from −13% to 39% for SAF values and −109% to 79% for S-values in different organs. In the spine, the clinically important target organ for Samarium Therapy, the differences in the S-values and SAF values are higher between XCAT phantom and CT when the phantom with identical BMI is employed (53.8% relative difference in S-value and 26.8% difference in SAF). However, the whole body dose values were the same between the calculations based on the CT and XCAT with different BMIs. Conclusion: The results indicated that atlas-based dosimetry using XCAT phantom even with matched BMI for patient leads to considerable errors as compared to image-based dosimetry that uses the patient’s own CT Patient-specific dosimetry using CT image is essential for accurate results.

60 APPLIED LIFE SCIENCES↗

Implementing the LSST Software Stack for DESGW processing and the Integration of Convolutional Neural Networks into the DESGW Pipeline

The Dark Energy Survey Gravitational Wave (DESGW) group strives to understand thelargescale structure of the universe and galaxies by looking for electromagnetic signatures intelescope images following gravitational wave detections. The DESGW group uses a processing pipeline to perform difference imaging to look for potential candidates. In order to perform these searches more effectively, we first explored using an alternative processing pipeline, the LSST Software Stack to analyze the telescope images. Because the LSST software stack is currently transitioning between its generation 2 and generation 3 system, we decided that while the software will be usable in the future once generation 3 is complete, at the moment its incompleteness makes it impractical to use. We then decided to work on improving the current pipeline by developing a module that integrates a Convolutional Neural Network (CNN) to test difference imaging products for bad subtractions due to misalignment.

Navarro, Alexander↗

SU-E-T-789: Validation of 3DVH Accuracy On Quantifying Delivery Errors Based On Clinical Relevant DVH Metrics

Purpose: Detection of treatment delivery errors is important in radiation therapy. However, accurate quantification of delivery errors is also of great importance. This study aims to evaluate the 3DVH software’s ability to accurately quantify delivery errors. Methods: Three VMAT plans (prostate, H&N and brain) were randomly chosen for this study. First, we evaluated whether delivery errors could be detected by gamma evaluation. Conventional per-beam IMRT QA was performed with the ArcCHECK diode detector for the original plans and for the following modified plans: (1) induced dose difference error up to ±4.0% and (2) control point (CP) deletion (3 to 10 CPs were deleted) (3) gantry angle shift error (3 degree uniformly shift). 2D and 3D gamma evaluation were performed for all plans through SNC Patient and 3DVH, respectively. Subsequently, we investigated the accuracy of 3DVH analysis for all cases. This part evaluated, using the Eclipse TPS plans as standard, whether 3DVH accurately can model the changes in clinically relevant metrics caused by the delivery errors. Results: 2D evaluation seemed to be more sensitive to delivery errors. The average differences between ECLIPSE predicted and 3DVH results for each pair of specific DVH constraints were within 2% for all three types of error-induced treatment plans, illustrating the fact that 3DVH is fairly accurate in quantifying the delivery errors. Another interesting observation was that even though the gamma pass rates for the error plans are high, the DVHs showed significant differences between original plan and error-induced plans in both Eclipse and 3DVH analysis. Conclusion: The 3DVH software is shown to accurately quantify the error in delivered dose based on clinically relevant DVH metrics, where a conventional gamma based pre-treatment QA might not necessarily detect.

60 APPLIED LIFE SCIENCES↗

Assessment and Coordination of EVSE Cybersecurity Standards

Cybersecurity certification programs for Electric Vehicle Supply Equipment (EVSE) are fragmented due to no single certification covering all aspects of the device and additionally the existence of multiple programs and under different levels of regulation. These devices are also confronted by the intricate assembly of product software, firmware, and hardware. Devices contain both logical and physical interfaces. These multifaceted devices have vulnerabilities at many levels and interconnect with other potentially vulnerable systems including the electric vehicle, the cloud where data and payment information are stored, and the electric grid and electric grid equipment including utilities. Of the EVSE certification programs that are found, none are directly for the cybersecurity of EVSE. Many standards are for safety, specifically battery safety, some are cybersecurity standards for other types of equipment and can be modeled for EVSE. In specific, ISA/IEC 62443 is found to be significantly in line with EVSE security needs and will be used in future testing to certify EVSE and help guide the project to demonstrate where gaps exist, where strengths lie in the standard and how this can be used to lead the certification efforts in harmonizing EVSE cybersecurity standards. In addition, there are multiple efforts that are currently seeking to build EVSE standards or revise existing standards to address gaps. This effort is seeking to establish a cybersecurity program for EVSE that will inform customers and help increase the level of security across products and state EVSE procurements to achieve consistency across different jurisdictions.

33 ADVANCED PROPULSION SYSTEMS↗

MolSym : A Python package for handling symmetry in molecular quantum chemistry

A consideration of the point group symmetry of molecules is often advantageous from a computational efficiency standpoint and sometimes necessary for the correct treatment of chemical physics problems. Many modern electronic structure software packages include a treatment of symmetry, but these are sometimes incomplete or unusable outside of that program’s environment. Therefore, we have developed the MolSym package for handling molecular symmetry and its associated functionalities to provide a platform for including symmetry in the implementation and development of other methods. Features include point group detection, molecule symmetrization, arbitrary generation of symmetry element sets and character tables, and symmetry adapted linear combinations of real spherical harmonic basis functions, Cartesian displacement coordinates, and internal coordinates. We present some of the advantages of using molecular symmetry as achieved by MolSym, particularly with respect to Hartree–Fock theory, and the reduction of finite difference displacements in gradient/Hessian computations. Furthermore, this package is designed to be easily integrated into other software development efforts and may be extended to further symmetry applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification of candidate diagnostic and prognostic biomarkers for human prostate cancer: RPL22L1 and RPS21

Prostate cancer (PCa) is one of the most common malignancies in men worldwide. This study was designed to investigate the potential of Ribosomal Protein L22-like1 (RPL22L1) and Ribosomal Protein S21 (RPS21) as diagnostic and prognostic biomarkers for PCa. First, RPL22L1 and RPS21 were screened as the key molecular of PCa by bioinformatics analysis. Subsequently, the prostate tissue samples were stained for antibodies against RPL22L1 and RPS21. The unbiased signal quantification was performed by ImageJ software, and the results showed that the expression of RPL22L1 and RPS21 exhibited significant differences between the PCa tissues and the normal prostate tissues. Receiver-operating characteristics (ROC) curves were prepared, and then the area under the curve (AUC) values of RPL22L1 and RPS21 were calculated as 0.798 and 0.768, and the likelihood ratio (LR) values of RPL22L1 and RPS21 were calculated as 2.86 and 2.53. These data implied that the over-expression of RPL22L1 and RPS21 is associated with the presence of PCa. The further analysis suggested that the expression of RPL22L1 and RPS21 were significantly higher in high Gleason grade than they were in low Gleason grade. In addition, in vitro studies were undertaken to evaluate the roles of RPL22L1 and RPS21 in PCa. The results revealed that these genes promote PCa cell proliferation, migration and invasion, and inhibit PCa cell apoptosis. Taken together, these data showed that RPL22L1 and RPS21 exhibited higher expression in human prostate cancer tissue, and involved in PCa cell proliferation and invasion. This research provided a novel insight into diagnostic and prognostic biomarkers for PCa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

pyEGAF: An open-source Python library for the Evaluated Gamma-ray Activation File

The Evaluated Gamma-ray Activation File (EGAF) is one of the most comprehensive resources for thermal neutron-capture data. This database contains data from prompt gamma activation analysis measurements carried out in a consistent manner using the same experimental configuration at the Budapest Research Reactor for 245 isotopes. Although these valuable datasets have been freely available for many years, one of the drawbacks is the outdated and cryptic Evaluated Nuclear Structure Data File (ENSDF) format that is currently adopted for dissemination, making it difficult for users unfamiliar with the format to access and utilize the data contained therein. Furthermore, the ENSDF format does not readily lend itself to modern computational technologies and a parser is required to interpret the complicated mixed-record format. To help overcome these challenges, we have developed a translator to convert the ENSDF-formatted datasets into an open standard JavaScript Object Notation (JSON) format enabling accessibility to applications using different programming languages running in different environments. To compliment this effort, we have also developed an open-source software package implemented in Python, pyEGAF, that is designed to interact with the JSON data structures for general purpose access, manipulation, and analysis of the neutron-capture $\gamma$-ray data in EGAF. The new format, together with the pyEGAF library, greatly enhances access to the wider applications community where EGAF data may be useful or is required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated defect identification in electroluminescence images of solar modules

Solar photovoltaic (PV) modules are susceptible to manufacturing defects, mishandling problems or extreme weather events that can limit energy production or cause early device failure. Trained professionals use electroluminescence (EL) images to identify defects in modules, however, field surveys or inline image acquisition can generate millions of EL images, which are infeasible to analyze by rote inspection. Here, we develop a rapid automatic computer vision pipeline (~0.5 seconds/module) to analyze EL images and identify defects including cracks, intra-cell defects, oxygen-induced defects, and solder disconnections. Defect identification is achieved with a machine learning model (Random Forest, ResNet models and YOLO) trained on 762 manually-labeled EL images of PV modules. We compare model performance on an imbalanced real-world validation set containing 134 EL images and determine that ResNet18 and YOLO are the optimal models; we next evaluated these models on a dedicated testing set (129 module images) with resulting macro F1 scores of 0.83 (ResNet18) and 0.78 (YOLO). Using a field EL survey of a PV power plant damaged in a vegetation fire, we analyze 18,954 EL images (2.4 million cells) and inspect the spatial distribution of defects on the solar modules. The results find increased frequency of ‘crack’, ‘solder’ and ‘intra-cell’ defects on the edges of the solar module closest to the ground after fire. We also find an abnormal increase of striation rings on cells which were assumed to be caused mainly in fabrication process. Our methods are published as open-source software. It can also be used to identify other kinds of defects or process different types of solar cells with minor modification on models by transfer learning.

14 SOLAR ENERGY↗

Quantum simulations of SO(5) many-fermion systems using qudits

The structure and dynamics of many-body systems are the result of a delicate interplay between underlying interactions. Fermionic pairing, for example, plays a central role in various physical systems, ranging from condensed matter to nuclear systems, where it can lead to collective phenomena such as superconductivity and superfluidity. In atomic nuclei, the interplay between pairing and particle-hole interactions leads to a high degree of complexity and intricate entanglement structures. Despite this apparent complexity, symmetries emerge and manifest themselves in observable regular patterns. These symmetries and their breakings have long been used to determine relevant degrees of freedom and simplify classical descriptions of many-body systems. Here, this work explores the potential utility of quantum computers with arrays of qudits in simulating interacting fermionic systems, when the qudits can naturally map the relevant degrees of freedom determined by an underlying symmetry group. The Agassi model of fermions interacting via particle-hole and pairing interactions is based on an underlying so(5) algebra. Such systems can intuitively be partitioned into pairs of modes with five basis states, which thus naturally map to arrays of d = 5 qudits (qu5its). Classical noiseless simulations of the time evolution of systems with up to twelve qu5its are performed, by implementing quantum circuits that are developed herein, using PYTHON codes invoking Google's CIRQ software. The resource requirements of the qu5it circuits are analyzed and compared with two different mappings to qubit systems: a physics-aware Jordan-Wigner mapping requiring four qubits per mode pair and a state-to-state mapping requiring three qubits per mode pair. While the dimensionality of Hilbert spaces in mappings to qu5it systems are less than those for the corresponding qubit systems, the number of entangling operations, depending on the available hardware, can either be greater or smaller than for the physics-aware Jordan-Wigner mapping. The state-to-state mapping, while having a smaller Hilbert space than Jordan-Wigner mappings, appears to be the least efficient in gate counts. Further, a previously unknown sign problem has been identified from Trotterization errors in time evolving high-energy excitations. There appear to be advantages in employing quantum computers with arrays of qudits to perform simulations of many-body dynamics that exploit the role of underlying symmetries, specifically in lowering the required quantum resources and in reducing anticipated errors that take the simulation out of the physical space. If the necessary entangling gates are not directly supported by the hardware, physics-aware mappings to qubits may, however, be advantageous for other aspects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-D-201-03: Imaging Cellular Pharmacokinetics of 18F-FDG in Inflammatory/Stem Cells

Purpose: Atherosclerosis is a progressive inflammatory condition that underlies coronary artery disease (CAD)—the leading cause of death in the USA. Thus, understating the metabolism of inflammatory cells can be a valuable tool for investigating CAD. To the best of our knowledge, we are the first to successfully investigate the pharmacokinetics of [18F]fluoro-deoxyglucose (18F-FDG) uptake in a single macrophages and compared with induced pluripotent stem cells (iPSCs) and mesenchymal stem cells (MSCs) with a novel imaging technique, radioluminescence microscopy, initially developed for cancer imaging. Methods: Live cells were cultured sparsely on Matrigel in a glass-bottom dish and starved for 1 hour before incubation with 250 microCi of 18F-FDG for 45 minutes. Excess radiotracer was removed using DMEM medium without glucose. Before imaging, DMEM (1 mL) was added to the cell culture and a 100 microm-thin CdWO4 scintillator plate was placed on top of the cells. Light produced following beta decay was imaged with a highly sensitive inverted microscope (LV200, Olympus) fitted with a 40x/1.3 high-NA oil objective, and an EM-CCD camera. The images were collected over 18,000 frames with 4×4 binning (1200 MHz EM Gain, 300ms exposure). Custom-written software was developed in MATLAB for image processing (Figure 1). For statistical analysis 10 different region-of-interests (ROIs) were selected for each cell type. Results: Figures 2A–2B show bright-field/fusion images for all three different cell types. The relationship between cell-to-cell comparisons was found to be linear for macrophages unlike iPSCs and MSCs, which were best fitted with moving or rolling average (Figure 2C). The average observed decay of 18F-FDG in a single cell of MSCs per second (0.067) was 20% and 36% higher compared to iPSCs (0.054) and macrophages (0.043), respectively (Figure 2D). Conclusion: MSCs was found to be 2–3x more sensitive to glucose molecule despite constant parameters for each cell type examined.

60 APPLIED LIFE SCIENCES↗

SU-E-T-519: Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom

Purpose To characterize the Cyberknife (CK) robotic system’s dosimetric accuracy of the delivery of MultiPlan’s Monte Carlo dose calculations using EBT3 radiochromic film inserted in a thorax phantom. Methods The CIRS XSight Lung Tracking (XLT) Phantom (model 10823) was used in this study with custom cut EBT3 film inserted in the horizontal (coronal) plane inside the lung tissue equivalent phantom. CK MultiPlan v3.5.3 with Monte Carlo dose calculation algorithm (1.5 mm grid size, 2% statistical uncertainty) was used to calculate a clinical plan for a 25-mm lung tumor lesion, as contoured by the physician, and then imported onto the XLT phantom CT. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0– 800 cGy. The test films (n=3) were irradiated using 325 cGy to the prescription point. Films were scanned 48 hours after irradiation using an Epson v700 scanner (48 bits color scan, extracted red channel only, 96 dpi). Percent absolute dose and relative isodose distribution difference relative to the planned dose were quantified using an in-house QA software program. Multiplan Monte Carlo dose calculation was validated using RCF dosimetry (EBT3) and gamma index criteria of 3%/3mm and 2%/2mm for absolute dose and relative isodose distribution measurement comparisons. Results EBT3 film measurements of the patient plans calculated with Monte Carlo in MultiPlan resulted in an absolute dose passing rate of 99.6±0.4% for the Gamma Index of 3%/3mm, 10% dose threshold, and 95.6±4.4% for 2%/2mm, 10% threshold criteria. The measured central axis absolute dose was within 1.2% (329.0±2.5 cGy) of the Monte Carlo planned dose (325.0±6.5 cGy) for that same point. Conclusion MultiPlan’s Monte Carlo dose calculation was validated using the EBT3 film absolute dosimetry for delivery in a heterogeneous thorax phantom.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-03: Beam Quality Correction Factors for Linear Accelerator with and Without Flattening Filter

Purpose: The impact of removing the flattening filter on absolute dosimetry based on IAEA’s TPR-398 and AAPM’s TG-51 was investigated in this study using Monte Carlo simulations. Methods: The EGSnrc software package was used for all Monte Carlo simulations performed in this work. Five different ionization chambers and nine linear accelerator heads have been modeled according to technical drawings. To generate a flattening filter free radiation field the flattening filter was replaced by a 2 mm thick aluminum layer. Dose calculation in a water phantom were performed to calculate the beam quality correction factor k{sub Q} as a function of the beam quality specifiers %dd(10){sub x}, TPR{sub 20,10} and mean photon and electron energies at the point of measurement in photon fields with (WFF) and without flattening filter (FFF). Results: The beam quality correction factor as a function of %dd(10){sub x} differs systematically between FFF and WFF beams for all investigated ionization chambers. The largest difference of 1.8% was observed for the largest investigated Farmer-type ionization chamber with a sensitive volume of 0.69 cm{sup 3}. For ionization chambers with a smaller nominal sensitive volume (0.015 – 0.3 cm{sup 3}) the deviation was less than 0.4% between WFF and FFF beams for %dd(10){sub x} > 62%. The specifier TPR{sub 20,10} revealed only a good correlation between WFF and FFF beams (< 0.3%) for low energies. Conclusion: The results confirm that %dd(10){sub x} is a suitable beam quality specifier for FFF beams with an acceptable bias. The deviation depends on the volume of the ionization chamber. Using %dd(10){sub x} to predict k{sub Q} for a large volume chamber in a FFF photon field may lead to not acceptable errors according to the results of this study. This bias may be caused by the volume effect due to the inhomogeneous photon fields of FFF linear accelerators.

60 APPLIED LIFE SCIENCES↗