Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solution processes for ultrabroadband and omnidirectional graded-index glass lenses with near-zero reflectivity in high concentration photovoltaics

Abstract Concentrator photovoltaic (CPV) systems, where incident direct solar radiation is tightly concentrated onto high-efficiency multi-junction solar cells by geometric optical elements, exhibit the highest efficiencies in converting the sun’s energy into electric power. Their energy conversion efficiencies are greatly limited, however, due to Fresnel reflection losses occurring at three air/optics interfaces in the most sophisticated dual-stage CPV platforms. This paper describes a facile one-step wet-etching process to create a nanoporous surface with a graded-index profile on both flat and curved glasses, with capabilities of achieving ~99% average transmission efficiency in a wide wavelength range from 380 nm to 1.3 µm and for a wide range of incident angles up to ±40° regardless of the polarization state of incident sunlight. The simplicity of the etching process remarkably increases their versatility in various optical elements that require unconventional form factors such as Fresnel lenses and microlens arrays, and/or demanding curvatures along with much reduced dimensions such as ball lenses. Etched glass surfaces on two-stage optical concentrating systems yield enhancements in total optical transmission efficiencies by 13.8% and in the photocurrent by 14.3%, as experimentally determined by measurements on microscale triple-junction solar cells. The presented strategy can be widely adapted in a variety of applications such as image sensors, display systems, and other optoelectronic devices.

36 MATERIALS SCIENCE↗

Fast neutron radiography-based on single-photon digital photosensor: concept and demonstration

For decades, fast neutron radiography performed using pulse-counting detectors employed PMTs coupled to plastic scintillator pixel arrays. SiPM-based systems are now sought to replace fragile PMTs, but conventional, “analog” SiPMs suffer from intrinsic limitations which limit their achievable performance. Among these limitations, a complete analog readout and digitizer chain is required, a counterintuitive approach when considering that the single-photon avalanche diode (SPAD), the basic unit cell of SiPMs, is a Boolean detector providing digital detection at the sensor level. This paper outlines a new concept for neutron radiography instrumentation by using photon-to-digital converters (PDCs, aka digital SiPMs), a fully digital solution to sense the scintillation light.

Pratte, Jean-Francois↗

Dipole-lattice nanoparticle resonances in finite arrays

We investigate how the periodic lattices define the collective optical characteristics of the silicon and titanium nanoparticle arrays. We examine the effects of dipole lattice on the resonances of optical nanostructures, including those made of lossy materials, such as titanium. Our approach involves employing coupled-electric-magnetic-dipole calculations for finite-size arrays, as well as lattice sums for effectively infinite arrays. Our model shows that the convergence to the infinite-lattice limit is faster when the resonance is broad, requiring fewer array particles. Our approach differs from previous works by altering the lattice resonance through modifications in the array period. We observed that a higher number of nanoparticles is necessary to achieve convergence to the infinite-array limit. Additionally, we observe that the lattice resonances excited next to higher diffraction orders (such as second order) converge more quickly toward the ideal case of an infinite array than the lattice resonances related to the first diffraction order. This work reports on the significant advantages of using a periodic arrangement of lossy nanoparticles and the role of collective excitation in enhancing response from transition metals, such as titanium, nickel, tungsten, and so on. The periodic arrangement of nanoscatterers allows for the excitation of strong dipoles, boosting the performance of nanophotonic devices and sensors by improving the strength of localized resonances.

36 MATERIALS SCIENCE↗

EarthScope Seismic Station A21K (A21K-6) Field Campaign Report

Seismic station A21K has been successfully operating over the last five years. The station was constructed on 4/24/2014 by creating a borehole using an auger drill and inserting a PVC pipe casing. Roughly one month later, on 6/2/2014, the seismometer, weather station (Vaisala WXT520 meteorological sensor), enclosure, and electronics were installed. Collected data is being reported in real-time and is publicly available. On rare occasion, the station has required in-person service/maintenance visits, occurring on 4/29/2015 (fix faulty cable), 4/5/2016 (swap VIE), and 8/4/2017 (general check-up visit while in the area). This station is one in a 280-station seismic array/grid that make up the EarthScope: Transportable Array (USArray) project, funded by the National Science Foundation. USArray is operated by the Incorporated Research Institutions for Seismology (IRIS), a nonprofit 503(c) Corporation founded in 1984, that is a consortium of over 100 US universities dedicated to the operation of science facilities for the acquisition, management, and distribution of seismological data.

North Slope of Alaska, seismology, Earth system↗

CORC $^{\circledR}$ cable terminations with integrated Hall arrays for quench detection

ReBCO superconducting cables have the potential to enable compact thermonuclear fusion reactors that operate at magnetic fields exceeding 20 T and allow operation at temperatures far exceeding the boiling point of liquid helium, potentially allowing for demountable magnets. Normal zone detection remains a challenge, and while novel quench detection techniques are an active area of research, few are non-invasive, provide real-time quench detection, and have been demonstrated with current ramp rates relevant for fusion reactors. To address this problem, a CORC$^{\circledR}$ cable termination is developed with integrated Hall sensors to monitor current redistribution as a proxy for quench detection. The methodology exploits the current sharing and layered topology in CORC$^{\circledR}$ cables, and allows quench detection using a localized sensor instead of co-wound voltage wires or optical fibers. Furthermore, experiments are presented where current redistribution is measured from induced quenches, and in a 0.2 meter CORC$^{\circledR}$ sample it is found that the Hall sensors detect normal zone transitions with a similar magnitude and temporal resolution as voltage measurements. To emulate the conditions of dynamic poloidal and central solenoidal fields, experiments are repeated with ramp rates up to 10 kA s -1 that demonstrate the potential to detect normal zone development over a range of experimental parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybrid Metasurface-Based Mid-Infrared Biosensor for Simultaneous Quantification and Identification of Monolayer Protein

Metasurfaces emerge as a promising photonic platform for biosensing because they offer strong optical confinement and tunable optical resonances. Here, we show that metasurface-based biosensors consisting of gold nanoantenna arrays loaded with graphene and working in the mid-infrared (mid-IR) spectral range can achieve simultaneous high-sensitivity and high-specificity detection of biomolecules. Strong light–molecule interactions in deeply subwavelength optical spots created by the biosensors allow us to determine the concentration of protein molecules via spectral shifts of the metasurface resonance. A combination of passive and active tuning of the metasurface sensors allows us to spectrally overlap the metasurface resonance and the protein vibrational modes, so that protein molecules can be identified via their characteristic mid-IR “fingerprints”. As a result, the high sensitivity and specificity of the metasurface sensors enable us to determine the secondary structure of protein immunoglobulin (IgG) molecules 4 orders of magnitude more sensitive than attenuated total reflection Fourier transform infrared spectroscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Identifying Different Classes of Seismic Noise Signals Using Unsupervised Learning

Abstract Proper classification of nontectonic seismic signals is critical for detecting microearthquakes and developing an improved understanding of ongoing weak ground motions. We use unsupervised machine learning to label five classes of nonstationary seismic noise common in continuous waveforms. Temporal and spectral features describing the data are clustered to identify separable types of emergent and impulsive waveforms. The trained clustering model is used to classify every 1 s of continuous seismic records from a dense seismic array with 10–30 m station spacing. We show that dominate noise signals can be highly localized and vary on length scales of hundreds of meters. The methodology demonstrates the complexity of weak ground motions and improves the standard of analyzing seismic waveforms with a low signal‐to‐noise ratio. Application of this technique will improve the ability to detect genuine microseismic events in noisy environments where seismic sensors record earthquake‐like signals originating from nontectonic sources.

Johnson, Christopher W.↗

Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Abisko: Deep codesign of an architecture for spiking neural networks using novel neuromorphic materials

The Abisko project aims to develop an energy-efficient spiking neural network (SNN) computing architecture and software system capable of autonomous learning and operation. The SNN architecture explores novel neuromorphic devices that are based on resistive-switching materials, such as memristors and electrochemical RAM. Equally important, Abisko uses a deep codesign approach to pursue this goal by engaging experts from across the entire range of disciplines: materials, devices and circuits, architectures and integration, software, and algorithms. Here, the key objectives of our Abisko project are threefold. First, we are designing an energy-optimized high-performance neuromorphic accelerator based on SNNs. This architecture is being designed as a chiplet that can be deployed in contemporary computer architectures and we are investigating novel neuromorphic materials to improve its design. Second, we are concurrently developing a productive software stack for the neuromorphic accelerator that will also be portable to other architectures, such as field-programmable gate arrays and GPUs. Third, we are creating a new deep codesign methodology and framework for developing clear interfaces, requirements, and metrics between each level of abstraction to enable the system design to be explored and implemented interchangeably with execution, measurement, a model, or simulation. As a motivating application for this codesign effort, we target the use of SNNs for an analog event detector for a high-energy physics sensor.

97 MATHEMATICS AND COMPUTING↗

Bridging Additive Manufacturing and Electronics Printing in the Age of AI

Printing techniques have been instrumental in developing flexible and stretchable electronics, including organic light-emitting diode displays, organic thin film transistor arrays, electronic skins, organic electrochemical transistors for biosensors and neuromorphic computing, as well as flexible solar cells with low-cost processes such as inkjet printing, ultrasonic nozzle, roll-to-roll coating. The rise of additive manufacturing provides even more opportunities to print electronics in automated and customizable ways. In this work, we will review the current technologies of printing electronics (including printed batteries, supercapacitors, fuel cells, and sensors), especially with 3D printing. In this age of ongoing AI revolution, the application of AI algorithms is discussed in terms of combining them with 3D printing and electronics printing for a future with automated optimization, sustainable design, and customizable and scalable manufacturing.

Chemistry↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗

Milestone report for MRT 8479: High Yield Xray Imager Preliminary Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi-MJ yield shots. Also, a new radiation tolerance CMOS imaging array is being developed to eliminate the significant background noise which limits the data quality of PDIXI. The HYXI Preliminary Design Review was completed at the end of Q4 FY23. The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the new CMOS imaging array. Initial time integrated NIF data will be collected in Q2 FY25, first time resolved imaging with Daedalus starting in Q2 FY26 and the final performance qualification of the complete HYXI system is scheduled for Q2 FY27.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months. Index Terms - photovoltaic module, floating PV systems, string, array, temperature, mismatch, utility scale.

ENGINEERING,SOLAR ENERGY↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to synthesize nanoparticle supercrystals

Highly ordered arrays of 3D faceted nanoparticle supercrystals are formed by self-assembly with controlled nanoparticle packing and unique facet dependent optical property by using a binary solvent diffusion method. The binary diffusion results in supercrystals whose size and quality are determined by initial nanoparticle concentration and diffusion speed. The supercrystal solids display unique facet-dependent surface plasmonic and surface-enhanced Raman characteristics. The supercrystals have potential applications in areas such as optics, electronics, and sensor platforms.

Fan, Hongyou↗

NXREFINE

NXRefine implements a complete workflow for both data acquisition and reduction of single crystal diffuse x-ray scattering collected as a series of area detector frames during continuous sample rotation. The data are stored in HDF5 files, which conform to the NeXus data format standard. These files contain a comprehensive set of metadata, including the incident wavelength, powder calibration scans used to define detector distances, beam centers, and yaw, pitch, and roll corrections. Automated peak searches of the three-dimensional data arrays define a set of Bragg peaks that are used to define an orientation matrix, defined according to Busing and Levy, which is then used to transform the data from angular coordinates to reciprocal space coordinates using the CCTW program. Multiple rotations at different detector translations and offset rotation axes are combined to ensure that there are no gaps in the reconstructed data, and allow the construction of masks to eliminate detector artifacts due to Compton scattering within the sensor layers. Finally, the data can be transformed into 3D-ΔPDF maps using the punch-and-fill method after symmetrization.

OSBORN, RAYMOND↗