ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

Mineralogical Evidence for Environmental Change in the Clay-Sulfate Transition at Gale Crater, Mars

A primary reason for selecting Gale crater as the Mars Science Laboratory (MSL) Curiosity rover landing site was a clear mineralogical transition from Fe/Mg smectite in older strata to hydrated Mg sulfate salts in younger strata observed in orbital visible/shortwave-infrared reflectance data. This transition has been observed in other early-Hesperian terrains on Mars and has been hypothesized to signal a planet-wide change in climate from relatively warm and wet to cold and dry. Curiosity studied the sedimentology and geochemical and mineralogical composition of rocks in this “clay-sulfate transition” region from sols 3052 to 3572 (i.e., March 2021 to August 2022), with arrival at the sulfate unit on sol 3574. Here, we report on the mineralogical measurements made by the CheMin X-ray diffractometer of the six drill targets in the clay-sulfate transition and the first drill target in the sulfate unit. We use compositional data and sedimentological observations to interpret depositional and diagenetic environments and present hypotheses to explain the transition from clay minerals to hydrated Mg sulfates.

E. B. Rampe↗

Mineralogical Signatures of Mars-Analog Eskers in Iceland

Orbital geomorphic observations of the martian surface suggest glaciers were present during much of Mars’ history. Amazonian- and Hesperian-aged lobate and viscous flow features and moraines, some of which retain remnant ice deposits, are typically interpreted as evidence for cold-based glaciation. There is some morphological evidence for wet-based glaciation, however, and the Late Noachian Icy Highlands model, in which melting of glaciers is hypothesized to create valley networks, would have generated features characteristic of wet-based glaciers, like eskers. Furthermore, recent work suggests lower gravity on Mars promoted subglacial water drainage, leading to channels and eskers. There is a paucity of morphological and compositional measurements of subglacial landforms on Earth to provide comparison to putative subglacial features on the martian surface, like eskers. Our group is studying the morphology, sedimentology, and composition of eskers formed in Iceland to identify characteristics of these features that will help determine whether sinuous ridges on Mars are ancient eskers. Here, we report on the mineralogy of eskers that were sampled during our summer 2022 field campaign and evaluate whether there is a mineralogical signature of eskers that is distinct from surrounding glacial outwash plains

E B Rampe↗

Recurrent 3he-Rich Solar Energetic Particle Injections Observed By Solar Orbiter at ∼0.5 Au

We report Solar Orbiter observations of six recurrent solar energetic particle injections in 2022 March 3−6 at ∼0.5 au. All but one were associated with jets emanating from a plage near a large sunspot in active region 12 957. We saw large jets in injections with high 3He and Fe enrichments and minor jets in injections with no or lower enrichments. Furthermore, the event with the highest enrichment showed a more compact configuration of the underlying photospheric magnetic field. The higher fluences as well as harder spectra were seen in the event with a simultaneous jet and wider eruption. However, in this case, the energy buildup time in the source might be required to produce such spectra. Extreme-ultraviolet images from Solar Orbiter revealed a number of intersecting loops at the base of jets not seen from 1 au that might be a precondition for the recurrent events.

Sun: particle emission↗

Concurrent Cooling Effects of Dynamic Line Ratings on Wind Plant Gen-Tie Lines

This report was prepared for the Wind Energy Technology Office for the FY 2022, quarter 2 deliverable. This details the use of dynamic line rating technology to rate a series of gen tie lines connecting wind plants to the regional transmission lines. This consists of two primary study regions, the first on the desert west of Idaho Falls, and the second in the region east of the Cascades along the Columbia River Gorge. The TREAD program that was developed at INL was used to create generated gen-tie lines based on nearby regional transmission line connections. The capacity availability of the gen tie lines are compared with the power production of the wind farms. Overall, the INL Site location shows a much greater capacity for the gen-tie lines due to the higher wind speeds. Across both locations, the HRRR data shows higher wind speeds than observed at the observational weather stations. For both the Columbia Gorge and Idaho areas, the sites show that a statically rate gen-tie could carry additional capacity far above the rated during periods of high wind due to the concurrent cooling effects.

17 WIND ENERGY↗

Forecasted Dynamic Line Ratings for Regional Transmission Lines

This report was prepared for the Wind Energy Technology Office for the FY 2022, quarter 3 deliverable. This details the use of forecasted dynamic line rating as an improvement over static rating for three transmission lines in three regions of interest. A selection of wind plants across Idaho, the Columbia River Gorge and offshore wind in the NYSERDA territory were modeled for their concurrent cooling effects for dynamic line rating. Regional transmission lines for the wind plant interconnections were determined and a CFD domain was created to determine local wind flows over the lines. A dynamic line rating for each of the lines was calculated for both weather observation data and HRRR model forecast data. The comparison of peaks in the wind power production were compared to the DLR peaks. It was determined that for shorter regional transmission lines, the effect of concurrent cooling that commonly occur with gen-tie lines were still valid. Concurrent cooling effects drop as the length of the regional transmission lines increase in distance from the wind plants. In addition, the accuracy of the forecasted ampacity to the weather observation data for ampacity was assessed. In general, the accuracy was best for the INL region with the NOAA-maintained sites. The Columbia River Gorge and Long Island sites showed similar levels of accuracy for the forecasted DLR. The accuracy levels were around 11% for the INL region, 15% for Columbia River Gorge and 7% for New York Long Island. The higher error for the Columbia Gorge region is likely due to the sparse availability of weather stations available, whereas both the INL site and Long Island are well instrumented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Post Irradiation Examination Results of Irradiated Yttrium Hydride

Department of Energy’s (DOE’s) Microreactor program (MRP) aims to provide the fundamental data to enable the development of microreactors. As such, material property data of critical materials for microreactor technologies are researched. Because substoichiometric yttrium dihydride (YHx, where x<2) is considered as a potential solid neutron moderator, its material property data has been combined in the Advanced Moderator Material Handbook which includes thermodynamic and thermophysical properties of YHx with the exception of irradiated material’s properties due to limited PIE. To fill the knowledge gap for the irradiated YHx, specimens and irradiation capsules were prepared at Los Alamos National Laboratory (LANL). Specimens were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory’s (INL’s). post-irradiation examination (PIE) was performed at INL’s Materials and Fuels Complex (MFC). This report compiles the PIE results of irradiated YHx specimens through fiscal years 2022 and 2023 (FY22-23) . The PIE data will directly be incorporated into the newer version of the Advanced Moderator Material Handbook. The main takeaways include that (i) the geometrical stability and mechanical integrity of YHx was intact with couple exceptions after high-temperature irradiations (600-800°C), (ii) hydrogen content variation due to manufacturing or irradiation in YHx caused visible surface discoloration, that is also related to the microstructural changes, (iii) qualitative comparisons of PIE methods implied that H retention was significantly higher at 600°C as compared to 800°C, (iv) thermal properties included signatures correlated with the H loss or re-gain, (v) importance of manufacturing readiness and initial as-manufactured specimens history was emphasized, (vi) the needs of targeted irradiations focusing on temperature and time parameters and very targeted PIE were specified.

08 HYDROGEN↗

Report on the Incorporation of Post-Irradiation Examination Results of Yttrium Hydride for Advanced Moderator Handbook

Department of Energy’s (DOE’s) Microreactor program (MRP) aims to provide the fundamental data to enable the development of microreactors. As such, material property data of critical materials for microreactor technologies are researched. Because substoichiometric yttrium dihydride (YHx, where x<2) is considered as a potential solid neutron moderator, its material property data has been combined in the Advanced Moderator Material Handbook which includes thermodynamic and thermophysical properties of YHx with the exception of irradiated material’s properties due to limited PIE. To fill the knowledge gap for the irradiated YHx, specimens and irradiation capsules were prepared at Los Alamos National Laboratory (LANL). Specimens were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory’s (INL’s). post-irradiation examination (PIE) was performed at INL’s Materials and Fuels Complex (MFC). This report compiles the PIE results of irradiated YHx specimens through fiscal years 2022 and 2023 (FY22-23) . The PIE data will directly be incorporated into the newer version of the Advanced Moderator Material Handbook. The main takeaways include that (i) the geometrical stability and mechanical integrity of YHx was intact with couple exceptions after high-temperature irradiations (600-800°C), (ii) hydrogen content variation due to manufacturing or irradiation in YHx caused visible surface discoloration, that is also related to the microstructural changes, (iii) qualitative comparisons of PIE methods implied that H retention was significantly higher at 600°C as compared to 800°C, (iv) thermal properties included signatures correlated with the H loss or re-gain, (v) importance of manufacturing readiness and initial as-manufactured specimens history was emphasized, (vi) the needs of targeted irradiations focusing on temperature and time parameters and very targeted PIE were specified.

08 HYDROGEN↗

Science Objectives for Human Exploration of Mars Workshop Report

The Science Objectives for Human Exploration of Mars Workshop was held in Denver, Colorado on May 4–6, 2022. The workshop was co-sponsored by NASA’s Science Mission Directorate and the Exploration Systems Development Mission Directorate to actively engage the planetary science community to determine what planetary science should be done by human crews on the martian surface and how those science objectives can be achieved. Sessions at the Science Objectives for Human Exploration of Mars Workshop were organized around specific planetary science objectives and mission architecture concepts that were identified during the workshop as the highest priority for human exploration. The intent of this workshop was to synthesize a notional, integrated concept of operations for each scenario to aid in planning and refining the mission architecture for the first human mission to Mars. Results from the Planetary Decadal Survey Report were released xx days before the workshop and were briefed to workshop participants who incorporated the findings in the discussions. With the Artemis missions, humans will return to the Moon using innovative technologies to explore the lunar surface. We will apply what we learn about exploration architecture, surface infrastructure, and science and exploration operations on and around the Moon to conduct successful missions with the first astronauts to Mars. A human mission to Mars will be a landmark achievement and a golden opportunity to make groundbreaking scientific discoveries on Mars. The potential scope of the science activities and impact of achieving those objectives are extraordinary.

Mars↗

Strategic Petroleum Reserve Enhanced Monitoring Compendium (FY 2022)

The Strategic Petroleum Reserve (SPR) is the world's largest supply of emergency crude oil. The reserve consists of four sites in Louisiana and Texas. Each site stores crude in deep, underground salt caverns. It is the mission of the SPR's Enhanced Monitoring Program to examine all available data to inform our understanding of each site. This report discusses the monitoring data, processes, and results for each of the four sites for fiscal year 2022.

02 PETROLEUM↗

Availability and Performance Loss Factors for U.S. PV Fleet Systems

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data and publish aggregated, anonymized results. This report is an update of our previous publications, specifically a FY 2021 performance index publication and a FY 2022 fleet degradation analysis. In this analysis, we have increased our data participants and system totals by around 10% to 8.5 GW and 24,000 separate inverter data channels. Four major analysis topics are considered in this report: Performance Index (PI) trends, PV system availability, soiling losses, and PV system degradation. Performance Index and inverter availability are assessed on a larger set of data from our FY 2021 report: 1,128 systems compared with 200 systems from before. The increased number of systems is due to an improved data quality methodology, as well as introducing new systems to the analysis. Overall results are similar to previously published values - overall inverter availability is low in the first six months of system performance before reaching steady-state by the end of the first year. Excluding this six-month startup period, system-level aggregated data shows a median (P50) system availability of 0.99 and a lower 10th percentile (P90) value of 0.95 (Figure ES-1). A dependence on system size is also demonstrated, with worse inverter availability results for larger PV systems. Causes of this effect are under investigation, but may be impacted by inverter size, which also show lower availability for larger inverter sizes. This report also investigates PI, correcting for degradation, soiling, snow, and availability. Following these corrections, the median system PI over its entire lifetime is 0.95. PI values reported here are approximately 3% lower than what we presented in our previous FY 2021 report. Soiling loss is assessed in a comprehensive way for the first time in this report. Results are presented using the COmbined Degradation and Soiling (CODS) method, as implemented in RdTools (v3.0.0a4). Soiling values are presented for 255 systems, which indicated irradiance-weighted soiling loss greater than 1%. The values have been published in an updated NREL soiling map at nrel.gov/pv/soiling.html. Finally, we investigated system degradation using three different data analysis techniques: conventional RdTools (year-on-year (YOY)), CODS, and Performance Loss Rate (PLR) analysis. Overall degradation results are consistent with our previous publications. Rerunning conventional RdTools on our updated fleet shows that some data partners have systematically fallen below the median system degradation rate (change over time) of -0.75 %/year. A comparison with PLR analysis, which looks at change in annual PI over time, shows that median system degradation is consistent with -0.5% to -0.75% per year change. However, at the P90 value, system degradation is substantially faster. These two results are consistent and indicate that resulting degradation statistics depend to a great degree on the population of PV systems making up the analysis cohort and whether soiling impacts the systems. The use of CODS for degradation analysis provides a different method for degradation assessment, which explicitly excludes the impact of recoverable soiling on degradation analysis. Excluding soiling effects yields an annual system degradation around -0.5% per year on average. This indicates that a portion of system performance loss may be attributed to periodic soiling that is not fully recovered. This report provides PV system owners/operators with background and methods to analyze PV system performance, give guidance for expected cohort performance, and performance loss values for use in pro-forma financial models, which guide new-build system design and bankability reports.

14 SOLAR ENERGY↗

FY22 X-Hab: Colorado School of Mines: Planetary Resource & In-Situ Material Habitat Outfitting for Space Exploration (PRISM-HOUSE)

The Colorado School of Mines (CSM) was awarded a project under the Moon to Mars eXploration Systems and Habitation (M2M X-Hab) Academic Innovation Challenge on June 10, 2021 for the proposed Planetary Resource & In-Situ Material Habitat Outfitting for Space Exploration (PRISM-HOUSE) lunar habitat system. The project deliverables have been executed concurrently with coursework in the CSM Space Resources program, specifically for the Space Resources Project I & II classes. A team was established in the fall semester of 2021 and a Systems Engineering process was followed to brainstorm initial concepts, determine objectives, flow down top-level requirements, and identify areas for which the project could best further the understanding of the overall system through targeted detailed design and design evaluation testing. This report summarizes the overall project, as well as specific work completed in the spring semester of 2022. PRISM-HOUSE is a lunar habitat system that is deployed on the lunar surface robotically and supports safe, long-term human occupancy while maximizing the use of in-situ resources and minimizing the mass of supplies and equipment that must be delivered from Earth. In this report, the team provides an overview and description of the objectives, the system, and how the current design was selected from various alternatives, as well as the resulting products of systems engineering tasks such as product and specification trees and flow-down requirements. A review of current risks and planned mitigation are reviewed. Four key PRISM-HOUSE systems are explored: the inflatable Habitat, External Structures & Environmental Protection (ESEP), Human Interior Goods (HIG), and ECLSS & Remote Outfitting (E&RO); for each, the team provides a detailed system description and an overview of analyses performed supporting final design, followed by a review of each Design Evaluation Test (DET) performed and resulting conclusions. The report closes with a suggestion of next steps.

Peter Corwin↗

Characterization of Infrequent Samples from the Concentration, Storage, and Transfer Facility: H-Area Diversion Box 1 (HDB-1) Sump Sample: January 25, 2022 Sample

Savannah River Remediation Engineering (SRR-E) requested that the Savannah River National Laboratory (SRNL) analyze the Concentration, Storage, and Transfer Facility (CSTF) samples from the following Tank Farm areas: the sump encasement, catch tank, drain cell, and waste tank annulus. In general, these CSTF samples will be analyzed on an infrequent basis and analyses will include detection for total beta/gamma, total alpha activities, density, free hydroxide, and pH measurements. This report presents characterization results for the H-Area diversion box 1 sump (HDB-1) January 2022 sample. The sample was slightly brown with a small amount of suspended fine particulates visually estimated to be less than 1% by volume. The results are measurements for total gamma, total alpha, total beta, density, free hydroxide, and pH.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Performance Computing Facility Operational Assessment 2022: Oak Ridge Leadership Computing Facility

The Oak Ridge Leadership Computing Facility (OLCF) was established to accelerate scientific discovery by providing world-leading computational performance and advanced data infrastructure. As a US Department of Energy (DOE) Office of Science user facility, the OLCF has managed the successful deployment and operation of a succession of leadership-class resources dedicated to open science. In addition to these resources, the OLCF staff continually strive to develop innovative processes and technologies, improve security, and empower users through allocation management and comprehensive user support and training. These efforts support the advancement of science by the OLCF users and benefit high-performance computing (HPC) facilities around the world. In calendar year (CY) 2022, the OLCF supported 1,681 users and 570 projects and exceeded all targets for user satisfaction. The facility received an average satisfaction score of 4.6 out of 5 on the annual user survey, and 96% of respondents reported a high satisfaction rate with the OLCF overall. Of the 3,212 user tickets submitted in CY 2022, OLCF staff resolved 97% within 3 business days. The facility also introduced several new services for users this year, including weekly virtual office hours with subject matter experts from ORNL and vendor partners; new views in MyOLCF that allow users to analyze allocation and compute usage for a project; the ability to build and run containers on Summit; and improved data visualization support and training resources.

97 MATHEMATICS AND COMPUTING↗

United States–Brazil Joint Study: A Preliminary Assessment of Opportunities and Challenges for Small Modular Reactors in Brazil

This report supplies the technical information to enable a broader understanding of different technology choices for nuclear reactors in Brazil. The assessment characteristics of this process include reactor technology, economic costs for deployment, and regulatory analyses of small modular reactors, advanced reactors, and microreactors. The analysis documented in this report provides economic and technological information to assist Brazil, whose official indicative scenarios show an increase in operating nuclear power from 2 Gigawatt in 2022 to 8–10 Gigawatt by 2050, in policy making and long-term energy planning. To protect company proprietary information, the information in this report was limited to publicly available information and therefore can only inform preliminary reactor technology assessments. This report does not recommend or endorse any specific reactor developer or technology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Chloride Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

Uranium electrorefining operations at Y-12 require validation for chlorine absorption and reflection. Plutonium chloride solution operations at Los Alamos National Laboratory require chlorine absorption validation. The growing need for chlorine validation is evident to the wider criticality safety community, with multiple attendees at the recent TEX 2.0 meeting at Lawrence Livermore National Laboratory (May 2023) requesting validation for chlorine (Idaho National Laboratory (INL), Institute de radioprotection et de surete nucleaire (IRSN), Savannah River Nuclear Site (SRNS), LANL, and Y-12). Los Alamos National Laboratory has recently performed, and benchmarked, an experiment titled Chlorine Worth Study (CWS) for the internal operations at the lab, but due to the difficulties in precisely characterizing the material compositions of the chlorine absorbers it is advantageous to perform a complimentary study with a different chlorine-based absorber material. Furthermore, having a uranium-based vs plutonium-based experiment provides a separate and important validation basis for criticality safety and nuclear data evaluation. The original final design report for the study of chlorine absorption using the TEX-HEU experimental base was presented in 2022, but used the same chlorine-bearing materials that were found to be difficult to characterize in the LANL benchmark. A complete redesign of the experiment has been performed looking at alternative absorber materials in various forms to produce an experiment that is fully characterizable. This report presents five novel chlorine experiments using the TEX-HEU test bed which provides direct comparison to the Y-12 and INL/Terrapower application needs, utilizing sodium chloride (NaCl) absorber plates. The absorber plates will consist of granulated NaCl (≥99.5% pure), which will be fully encapsulated in aluminum tins, providing a simple but effective chlorine-based absorber material that can be completely characterized. Of the five configurations presented in this report, it is expected that two or three configurations will be down selected for the actual experiment, with the other configurations being alternates. Three of the configurations are in the standard configuration, where the absorber is placed directly on the HEU fuel plates, and two in the sandwich configuration, where the absorber is surrounded by polyethylene moderators to force additional neutron thermalization prior to reaching the absorber. There are two thicknesses of NaCl absorber plates: 3/16” and 1/4” active thicknesses (i.e. not including the encapsulation). Both variations of the absorbers have an active absorber radius of 6” and a total radius of 7.5” to match the diameter of the HEU plates, with the outer 1.5” being aluminum encapsulation. The high-density polyethylene (HDPE) moderators are of the thicknesses: 27/16”, 7/4”, 1/8”, 11/16”, and 3/4”. The final configurations have six (one sandwich and one standard configuration), eight (one sandwich and one standard configuration), and 18 total fuel layers (standard configuration). The standard and sandwich configurations were designed such that the differences in moderator thicknesses are 1” HDPE, which were already procured for the original CED-2. The proposed configurations were precisely tuned to closely match the sensitivity profiles and neutron spectra of the Y-12 upset cases and were also compared to the INL/Terrapower upset cases. The assessment of experimental uncertainties of the non-absorber components was predicted to be 0.00114 Δk eff . The assessment of uncertainties resulting from the absorbers was predicted to be 0.00029 Δk eff . This results in a total uncertainty of 0.00118 Δk eff . Many of the largest uncertainties, namely the moderator densities, may be reduced with precision dimensional inspection of the components. The 1” HDPE moderators as well as the HDPE reflectors from the original CED-2 were incorporated in the final designs presented here. Additional HDPE moderator plates must be fabricated to complete the configurations. NaCl absorber plates will by fabricated at LLNL. The total additional cost is expected to be $\$$54,250 for the remaining components. Precise inspection, including dimensional, mass, density, and impurity, is recommended for all components. LLNL estimates that these costs are around $\$$12,000. It is expected, based on previous TEX-HEU experiments, that three weeks of experimental facility time is needed to complete the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Report on the 4th Marine Energy Instrumentation and Data Workshop

The 4th Marine Energy Instrumentation and Data workshop was held on March 16 - 17 2022. This gathering brought together marine energy (ME) developers, researchers, and stakeholders to discuss the current state of ME technologies and the industry's instrument and data needs. The overall objective of the workshop was to identify gaps facing the ME industry for needed data collection, processing, and analysis. This report contains findings and recommendations derived from the discussions and presentations during the workshop.