Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Universal Maximum Strength of Solid Metals and Alloys

As described here, interstitial electron density ρ o is offered as a direct metric for maximum strength in metals, arising from universal properties derived from an electron-gas – ρ o sets the exchange-correlation parameter r s in density-functional theory (DFT). It holds also for maximum shear strength τ max in polycrystals [Phys. Rev. Lett. 124, 125501]. Elastic moduli and τ max for polycrystalline (amorphous) metals are linear with ρ o and melting T m (glass-transition T g ) temperature. ρ o or r s , even with rule-of-mixture estimate, predicts relative strength for rapid, reliable selection of high-strength alloys with ductility, as confirmed for elements to steels to complex solid-solutions, and validated experimentally.

36 MATERIALS SCIENCE↗

AI-Driven Crack Detection for Remanufacturing Cylinder Heads Using Deep Learning and Engineering-Informed Data Augmentation

Detecting cracks in cylinder heads traditionally relies on manual inspection, which is time-consuming and susceptible to human error. As an alternative, automated object detection utilizing computer vision and machine learning models has been explored. However, these methods often face challenges due to a lack of sufficiently annotated training data, limited image diversity, and the inherently small size of cracks. Addressing these constraints, this paper introduces a novel automated crack-detection method that enhances data availability through a synthetic data generation technique. Unlike general data augmentation practices, our method involves copying cracks from one location to another, guided by both random and informed engineering decisions about likely crack formations due to cyclic thermomechanical loads. The innovative aspect of our approach lies in the integration of domain-specific engineering knowledge into the synthetic generation process, which substantially improves detection accuracy. We evaluate our method’s effectiveness using two metrics: the F2 score, which emphasizes recall to prioritize detecting all potential cracks, and mean average precision (MAP), a standard measure in object detection. Experimental results demonstrate that, without engineering insights, our method increases the F2 score from 0.40 to 0.65, while maintaining a stable MAP. Incorporating detailed engineering knowledge further enhances the F2 score to 0.70 and improves MAP to 0.57, representing increases of 63% and 43%, respectively. These results confirm that our approach not only mitigates the limitations of traditional data augmentation but also significantly advances the reliability and precision of crack detection in industrial settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design for Vibration Monitoring: A Methodology for Reliable and Cost-Effective Vibration Monitoring

The purpose of health monitoring systems is to detect failures or defects for increased safety and performance and to provide on-condition maintenance with reduced costs. The problems associated with health monitoring systems include high rates of false alarms and missed failures, which make monitoring an unreliable and costly task. The reason for this is that unaccounted variations invalidate signal modeling assumptions. Our approach was to focus on vibration monitoring of rotating components. We analyzed baseline signals to determine statistical variations, identify and model factors that influence vibrations (pre-production vs. post-production variations), determine hit and false alarm rates with baseline flight data, model and predict effects of defects and variations on vibrations, and develop algorithms and metrics for failure and anomaly detection in the presence of variations.

Tumer, Irem Y.↗

Standard Modular Architecture for Consumer End Plug and Play Interfaces

The growth in load and generation sources at the edge of the grid is driving the innovation in power electronic (PE) grid interfaces at the consumer end to improve the grid resiliency, reliability, security, and cost of the future infrastructure. Novel PE technologies are key enablers for the future grid infrastructure to handle the issues that arise because of the projected growth. This paper introduces a novel fundamental building block (FBB) architecture with plug-and play features. An example framework that enables co-ordination of multiple FBBs hierarchically to provide various grid functions is also presented. The FBBs are designed to be equipped with advanced features like online health monitoring, embedded intelligence, and decision-making capability for enhancing the metrics of consumer end plug and play interfaces. The paper elaborates on the proposed architecture and the developed framework i.e., the controls, communication, protection, and the corresponding timing requirements for the building blocks. The architecture and the framework have been validated through simulations and the communication framework has been validated with a control hardware in the loop platform.

Chinthavali, Madhu Sudhan↗

Examination of coal combustion management sites for microbiological and chemical signatures of groundwater impacts

Coal combustion accounts for 40% of the world’s electricity and generates more than a billion tons of coal combustion products (CCP) annually, half of which end up in landfills and impoundments. CCP contain mixtures of chemicals that can be mobile in the environment and impact the quality of surface water and potable groundwater. In this investigation, water samples from 14 coal combustion management sites across 4 physiographic regions in the United States, paired with background and down-gradient groundwater samples, were analyzed for water chemistry and microbiology. The objective was to determine if microbiology data alone, or supported by chemistry data, could reliably differentiate source waters and identify sites where CCP is known or expected to be influencing groundwater. Two percent of the total amplicons showed genus level conservation across CCP management sites, regions, and sample types; corresponding to ubiquitous, facultatively aerobic proteobacterial taxa that are generally recognized for the potential to respire using different terminal electron acceptors. Ordination plots did not reveal significant differences ( p > 0.05) in 16S rRNA gene amplicon diversity by CCP management site, water sample types, or physiographic regions. Contrastingly, chemistry distinguished sample types by standard water quality metrics (total dissolved solids, Ca:SO 4 ratio), alkali earth metals (K, Na, Li), selenium, boron, and fluoride. A focused evaluation of 16S rRNA gene amplicons for a subset of CCP management sites revealed microbiological features and chemical drivers (F, Ca, temperature) that positively identified the single CCP management site confirmed to have groundwater impacted by CCP leachate. At this site, 9 genera (>0.5% relative abundance) were exclusive to CCP porewater and downgradient groundwater. Inferred metabolisms for these taxa indicates potential for N and S biogeochemical transformations and 1-C metabolism that are consistent with a reducing environment, as evidenced by low ORP and depleted SO 4 2− . This research contributes to a growing understanding of conditions where these data types, analyses, and interpretation methods could be applied for distinguishing influence from CCP on the surrounding environment, as well as practical limitations.

01 COAL, LIGNITE, AND PEAT↗

Insights into Methodologies and Operational Details of Resource Adequacy Assessment: A Case Study with Application to a Broader Flexibility Framework

Assessing and maintaining resource adequacy (RA) is a core pillar of power systems. However, recent changes in the physical makeup of these systems and the conditions under which these systems must operate have yielded a renewed interest in the methods, metrics, and assumptions that underpin RA assessments. In this paper, we systematically explore a wide range of RA modeling dimensions, including: the objective function and level of operational detail in the underlying model formulation; the quantity (look-ahead) and quality (accuracy) of data that is available for making operational decisions within those models; and the physical configuration of solar photovoltaics (PV) with battery storage hybrid resources. We apply a set of probabilistic RA tools and production cost modeling tools to a realistic test system based loosely on a future Electric Reliability Council of Texas power system dominated by solar PV resources. Under the assumptions of our system and models, we find that multi-stage probabilistic assessments may provide a more robust evaluation of RA by capturing a wider range of operational and system interactions, but this comes at a computational cost of 1-2 orders of magnitude longer run time depending on the specific configuration. In addition, the information on thermal generator availability impacts RA performance by an order of magnitude more than solar resource forecasts, which is driven by the comparatively larger magnitude of thermal outages than solar forecast errors within our test system. Lastly, the flexibility provided by hybrid and other resources can help reduce system load-shedding event frequencies and enable the system to be more robust to inaccurate forecast information, and alternative hybrid inverter sizes can impact RA levels by 1-2 orders of magnitude. Our results point to the importance of a broader flexibility framework to describe the interaction between (1) flexibility "supply" from both physical resource capabilities and operational constraints considered in the modeling, and (2) flexibility "demand" from forecast errors, thermal generator outages, and other sources of uncertainty, as well as their RA impacts. Results are likely sensitive to the system buildout explored; future work could consider additional system configurations and conditions.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Benchmarking noise extrapolation with the OpenPulse control framework

Distilling precise estimates from noisy intermediate scale quantum (NISQ) data has recently attracted considerable attention Kandala et al., Nature (London) 567, 491 (2019). In order to augment digital qubit metrics, such as gate fidelity, we discuss analog error mitigability, i.e., the ability to accurately distill precise observable estimates, as a hybrid quantum classical computing benchmarking task. Specifically, using Rabi oscillations as a test program, we characterize single qubit error rates on IBM's Poughkeepsie superconducting quantum hardware, incorporate control-mediated noise dependence into a generalized rescaling protocol, and analyze how noise characteristics influence Richardson extrapolation-based error mitigation. Finally, our results identify regions in the space of Hamiltonian control fields and circuit depth which are most amenable to reliable noise extrapolation, as well as shed light on how low-level hardware characterization can be used as a predictive tool for uncertainty quantification in error-mitigated NISQ computations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Forest aboveground biomass estimation through integration of sentinel-2 and PALSAR-2 time series: assessing models trained on GEDI and field inventory benchmarks

Accurate and spatially explicit forest Aboveground Biomass (AGB) mapping through remote sensing is critical for quantifying terrestrial carbon stocks and informing effective forest management strategies. However, AGB estimation in dense forests with complex terrain remains challenging due to satellite sensor signal saturation problem (saturation issue occurs in high biomass forests), structural complexity, and limited ground truth for calibration. This study presents a novel framework that integrates multi-temporal Sentinel-2 optical imagery, ALOS PALSAR-2 Synthetic Aperture Radar (SAR) data, and topographic variables with explainable Machine Learning to map AGB across mountainous forests within subtropical and temperate oceanic climate zones of Mexico. We evaluate the effects of temporal granularity and sensor synergy by comparing multiple temporal inputs and sensor configurations (Sentinel-2, PALSAR-2, and their fusion), and assess model performance using two reference datasets: NASA GEDI LiDAR-derived biomass and Mexico’s National Forest and Soil Inventory (INFyS). Our results showed that models trained on INFyS consistently outperformed those trained on GEDI, highlighting limitations in GEDI’s reliability in biomass estimates within this study region. Furthermore, the integration of Sentinel-2 and PALSAR-2 provided improved predictions compared to single-sensor models, particularly when combined with temporally explicit yearly statistics. The best-performing model, which was trained on INFyS data, and considered both Sentinel-2 and PALSAR-2 yearly statistics, as well as topographic variables, achieved an R2 of 0.64, RMSE of 51.10 Mg/ha, and relative RMSE (rRMSE) of 58.69%. Explainable ML analysis identified Sentinel-2 spectral indices and topographic features as key predictors, while PALSAR-2 metrics provided complementary information, partially mitigating saturation effects in high-biomass areas. Specifically, integrating both sensors substantially improved AGB estimation in high biomass forest (≥200 Mg/ha), yielding 98% gains over optical-only model, with resulting estimates exceeding GEDI L4B by 29% and ESA-CCI-BIOMASS by 174%. Terrain-stratified analysis indicated close agreement with GEDI in low-slope areas, with increasing divergence as slope steepness increased, while estimates remained consistently higher than ESA-CCI-BIOMASS across all slope classes. The proposed approach advances multi-sensor fusion and temporal feature engineering for AGB mapping using open-access satellite datasets, providing a scalable and reproducible framework for annual biomass monitoring in topographically complex mountainous forests. The resulting 25 m resolution biomass product has the potential to provide spatially detailed information for forest monitoring and may support applications in carbon accounting and forest management.

54 ENVIRONMENTAL SCIENCES↗

An Alternative Timing and Synchronization Approach for Situational Awareness and Predictive Analytics

Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.

Chinthavali, Supriya↗

Evaluation of Time-Series Gap-Filling Methods for Solar Irradiance Applications

A complete solar resource data set is essential for any stage of a solar energy project - from feasibility studies to daily operations. But measured or modeled solar resource data are prone to data gaps and data quality issues. To mitigate these issues, a data imputation process should be implemented to obtain a complete and reliable temporal and spatial data series. This study focused on imputing temporal scales by applying random and artificial data gaps and then implementing eight imputation methods, including the Kalman filtering and smoothing and stine interpolations. These methods were implemented on 1-minute to half hourly irradiance data for 1 year using a few locations from the National Solar Radiation Database (NSRDB) and ground measurement data set. The results demonstrated that some of the simpler methods, such as the stine and linear interpolation methods, were the relatively best models based on the statistical metrics for imputing NSRDB and ground measurement data, respectively.

14 SOLAR ENERGY↗

Extreme Temperature Cryptography Based On Nitrogen-Incorporated Ultrananocrystalline Diamond

Physical entropy sources that remain stable under extreme temperatures are essential for cryptography in emerging technological frontiers in deep space exploration, geothermal energy harvesting, and nuclear energy. However, conventional semiconductor platforms fail to generate stable and reliable cryptographic keys above 200 degrees C due to performance degradation. Here, we report a diamond-based cryptographic primitive that exploits the defect-rich sp 2 -bonded grain boundary network in nitrogen-incorporated ultrananocrystalline diamond (n-UNCD) film as a robust entropy source to generate cryptographic keys that remain operationally stable even after enduring extreme temperatures of 700 degrees C for 54 h while also surviving thermal cycling between room temperature and 700 degrees C for 48 h. The strength of the generated keys is assessed through several cryptographic metrics such as bit uniformity, entropy, hamming distances, and correlation coefficients, all of which are found to be near their respective ideal values. Moreover, the generated keys pass the NIST SP 800 and SP 800-90B tests and are also resilient to supply bias variations and a regression-based machine learning attack model based on the Fourier series. The robustness of the keys is attributed to the better thermal stability and chemical inertness of the n-UNCD film. This is supported by high-resolution energy-dispersive X-ray spectroscopy (EDS), which shows no significant lateral diffusion of metal atoms into the n-UNCD layer, and by Raman spectroscopy, which reveals no significant changes in the bonding configuration of the n-UNCD structure. Our findings highlight the remarkable potential of n-UNCD film for extreme environment cryptography by expanding the operational limits of conventional hardware security platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Equity in Utility Regulation

Increasingly, states are recognizing equity as a goal of utility regulation, going beyond traditionally stated objectives to ensure that electricity systems are reliable, safe, and fairly priced. State initiatives are critical not only to address historical inequities, but to ensure equitable benefits and burdens in the transition to net-zero emissions by 2050. This report provides four perspectives on advancing equity in electric utility regulation, from representatives of energy justice and consumer organizations and a leading utility in this area. The authors provide recommendations related to regulatory issues such as stakeholder engagement, defining "public interest," intervenor funding, electricity infrastructure siting, access to distributed energy technologies, consumer protections, bill affordability programs, rate design, program design, and metrics to track and evaluate results of policies, regulations, and programs intended to deliver equitable outcomes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An automated and portable method for selecting an optimal GPU frequency

Power consumption poses a significant challenge in current and emerging graphics processing unit (GPU) enabled high-performance computing systems. In modern GPUs, dynamic voltage frequency scaling (DVFS) appears to be a reliable control to regulate power consumption and performance. However, the DVFS design space is large - hence, brute-force approaches are infeasible to select the optimal frequency. Furthermore, no single frequency can be universally optimal for applications with varying computational intensities. Thus, the application's complexity and the availability of a wide range of frequency settings are a challenge in selecting the optimal frequency configuration for a given GPU workload. To that end, this paper proposes a systematic approach that consists of three steps. The feature characterization study identifies the fine-grain GPU utilization metrics that influence the power consumption and execution time of a given workload. To understand the performance, power, and energy consumption behaviors of a workload across GPU's DVFS design space, we derived analytical power and performance models using the identified fine-grain features. Here, it is shown that the same set of GPU utilization metrics can estimate both the power consumption and execution time while being agnostic of changes to frequency and input sizes. Applying a power control with the single objective of reducing power may cause performance degradation, leading to more energy consumption. A multi-objective approach is proposed to select the optimal GPU DVFS configuration for a workload that reduces power consumption with negligible degradation in performance. The evaluation was conducted using SPEC ACCEL benchmarks and three real applications - NAMD LAMMPS, and LSTM on NVIDIA GV100, GA100, and AMD MI210 GPUs. On average, real applications showed 29.6% energy savings with a performance loss of 5.2% on GA100 and 22.6% energy savings with a performance loss of 4.7% on GV100. Moreover, the proposed models are portable to real applications, GPU architectures, and vendors, and require metric collection at only the default frequency rather than all supported DVFS configurations. Additionally, we conducted a comparison between our models and the GPU assembly instructions (PTX)-based static models. The results revealed a significant reduction in the average error rates, with a decrease from 19.7% to 3.1% for power models and from 29.4% to 5.2% for performance models.

97 MATHEMATICS AND COMPUTING↗

Climate Nowcasting

The climate is changing so rapidly that climatologies based on historical statistics cannot reliably capture the current risk of extreme weather events hazardous to society. Decision relevant projections of weather extreme probability over the next 10–15 years are needed to enable adaptation and resilience in the face of this evolving risk. Current weather forecasts/predictions and long-term climate projections for decades into the future are inadequate for providing this information to stakeholders that need it, targeting forecast horizons either too short or too far into the future. We argue that a new approach is needed: climate nowcasting. Climate nowcasting would focus on user-inspired extreme metrics over the next 10–15 year time frame, targeting specific impacts and locations down to a local scale, by engaging with stakeholders to understand their needs and provide information in a format relevant for decision making. Importantly, climate nowcasting will not consist of a single approach or data set, involving rather data fusion from different sources of information: simulations, observations and data driven methods, likely through different weights depending on the metric of interest. Predictions must be accompanied by serious engagement with stakeholders facing climate risks, and clearly present uncertainties and limitations of any prediction. Such a vision is very different from how typical climate or weather forecasts are applied today.

Gettelman, Andrew↗

Toward Drilling the Perfect Geothermal Well: An International Research Coordination Network for Geothermal Drilling Optimization Supported by Deep Machine Learning and Cloud Based Data Aggregation

The EDGE project, supported by the U.S. Department of Energy Geothermal Technologies Office under award DE-EE0008793, established a data-driven framework for improving the efficiency, cost-effectiveness, and reliability of geothermal well drilling. The project focused on developing scalable data infrastructure, advanced machine learning and probabilistic models, and integrated analytics tools to support continuous drilling optimization. A central objective was to reduce geothermal drilling costs by up to seventy percent while minimizing the risk of well failure through predictive diagnostics and adaptive planning. Over the project period, a comprehensive data repository was designed and deployed, incorporating records from over one hundred geothermal wells across varied geological settings. This repository supported both structured and unstructured data and adhered to FAIR data principles, enabling provenance tracking, quality control, and standardized metadata. The project introduced automated ingestion pipelines and a cloud-hosted platform that facilitated access to raw, processed, and derived datasets. This infrastructure served as the foundation for model development and analysis. Machine learning workflows were developed to predict key drilling metrics including rate of penetration, non-productive time, and total drilling costs. Self-organizing maps and dimensionality reduction methods were used to uncover operational patterns and outliers, while supervised learning algorithms such as random forests and deep neural networks were applied to forecast performance outcomes. The models were validated on heterogeneous datasets from both U.S. and Icelandic fields, demonstrating variable but significant predictive accuracy. The results indicated that finer temporal resolution, inclusion of lithological data, and consistency in operational annotations could substantially improve model performance. The project also implemented process mining techniques to reconstruct state-transition models from drilling event logs. These models enabled the identification of deviations from optimal workflows and provided insights into recurring failure modes. Analysis of non-productive time highlighted the impact of equipment failures, geological challenges, and human factors, offering opportunities for targeted mitigation strategies. The EDGE Dashboard was developed as a web-based expert system integrating data visualization, model outputs, and user-driven queries. It provided an accessible interface for operators to explore historical data, evaluate predicted outcomes, and compare drilling scenarios. Initial feedback from project partners suggested that the dashboard could serve as a foundation for more advanced advisory and optimization tools. Overall, the EDGE project demonstrated the feasibility and value of applying modern data science techniques to geothermal drilling. It delivered a set of interoperable tools and models that can support more efficient, lower-risk well development. The findings point toward a viable path for transitioning from advisory analytics to semi-autonomous drilling systems, contingent on continued collaboration, expanded datasets, and field validation. The project results have immediate relevance for drilling operations, data management practices, and future geothermal R&D efforts aimed at achieving reliable, cost-competitive geothermal energy at scale.

15 GEOTHERMAL ENERGY↗

Automated Generation and Assessment of Autonomous Systems Test Cases

This slide presentation reviews some of the issues concerning verification and validation testing of autonomous spacecraft routinely culminates in the exploration of anomalous or faulted mission-like scenarios using the work involved during the Dawn mission's tests as examples. Prioritizing which scenarios to develop usually comes down to focusing on the most vulnerable areas and ensuring the best return on investment of test time. Rules-of-thumb strategies often come into play, such as injecting applicable anomalies prior to, during, and after system state changes; or, creating cases that ensure good safety-net algorithm coverage. Although experience and judgment in test selection can lead to high levels of confidence about the majority of a system's autonomy, it's likely that important test cases are overlooked. One method to fill in potential test coverage gaps is to automatically generate and execute test cases using algorithms that ensure desirable properties about the coverage. For example, generate cases for all possible fault monitors, and across all state change boundaries. Of course, the scope of coverage is determined by the test environment capabilities, where a faster-than-real-time, high-fidelity, software-only simulation would allow the broadest coverage. Even real-time systems that can be replicated and run in parallel, and that have reliable set-up and operations features provide an excellent resource for automated testing. Making detailed predictions for the outcome of such tests can be difficult, and when algorithmic means are employed to produce hundreds or even thousands of cases, generating predicts individually is impractical, and generating predicts with tools requires executable models of the design and environment that themselves require a complete test program. Therefore, evaluating the results of large number of mission scenario tests poses special challenges. A good approach to address this problem is to automatically score the results based on a range of metrics. Although the specific means of scoring depends highly on the application, the use of formal scoring - metrics has high value in identifying and prioritizing anomalies, and in presenting an overall picture of the state of the test program. In this paper we present a case study based on automatic generation and assessment of faulted test runs for the Dawn mission, and discuss its role in optimizing the allocation of resources for completing the test program.

Testing challenges↗

Unstructured Grid Adaptation and Solver Technology for Turbulent Flows

Unstructured grid adaptation is a tool to control Computational Fluid Dynamics (CFD) discretization error. However, adaptive grid techniques have made limited impact on production analysis workflows where the control of discretization error is critical to obtaining reliable simulation results. Issues that prevent the use of adaptive grid methods are identified by applying unstructured grid adaptation methods to a series of benchmark cases. Once identified, these challenges to existing adaptive workflows can be addressed. Unstructured grid adaptation is evaluated for test cases described on the Turbulence Modeling Resource (TMR) web site, which documents uniform grid refinement of multiple schemes. The cases are turbulent flow over a Hemisphere Cylinder and an ONERA M6Wing. Adaptive grid force and moment trajectories are shown for three integrated grid adaptation processes with Mach interpolation control and output error based metrics. The integrated grid adaptation process with a finite element (FE) discretization produced results consistent with uniform grid refinement of fixed grids. The integrated grid adaptation processes with finite volume schemes were slower to converge to the reference solution than the FE method. Metric conformity is documented on grid/metric snapshots for five grid adaptation mechanics implementations. These tools produce anisotropic boundary conforming grids requested by the adaptation process.

Park, Michael A.↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗