Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference frames”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Gaussian Kernel Methods for Seismic Fragility and Risk Assessment of Mid-Rise Buildings

Seismic fragility functions can be evaluated using the cloud analysis method with linear regression which makes three fundamental assumptions about the relation between structural response and seismic intensity: log-linear median relationship, constant standard deviation, and Gaussian distributed errors. While cloud analysis with linear regression is a popular method, the degree to which these individual and compounded assumptions affect the fragility and the risk of mid-rise buildings needs to be systematically studied. This paper conducts such a study considering three building archetypes that make up a bulk of the building stock: RC moment frame, steel moment frame, and wood shear wall. Gaussian kernel methods are employed to capture the data-driven variations in the median structural response and standard deviation and the distributions of residuals with the intensity level. With reference to the Gaussian kernels approach, it is found that while the linear regression assumptions may not affect the fragility functions of lower damage states, this conclusion does not hold for the higher damage states (such as the Complete state). In addition, the effects of linear regression assumptions on the seismic risk are evaluated. For predicting the demand hazard, it is found that the linear regression assumptions can impact the computed risk for larger structural response values. However, for predicting the loss hazard with downtime as the decision variable, linear regression can be considered adequate for all practical purposes.

58 GEOSCIENCES↗

HarDWR - Harmonized Water Rights Records

For a detailed description of the database of which this record is only one part, please see the HarDWR meta-record. Here we present a new dataset of western U.S. water rights records. This dataset provides consistent unique identifiers for each spatial unit of water management across the domain, unique identifiers for each water right record, and a consistent categorization scheme that puts each water right record into one of 7 broad use categories. These data were instrumental in conducting a study of the multi-sector dynamics of intersectoral water allocation changes through water markets (Grogan et al., in review). Specifically, the data were formatted for use as input to a process-based hydrologic model, WBM, with a water rights module (Grogan et al., in review). While this specific study motivated the development of the database presented here, U.S. west water management is a rich area of study (e.g., Anderson and Woosly, 2005; Tidwell, 2014; Null and Prudencio, 2016; Carney et al, 2021) so releasing this database publicly with documentation and usage notes will enable other researchers to do further work on water management in the U.S. west. The raw downloaded data for each state is described in Lisk et al. (in review), as well as here. The dataset is a series of various files organized by state sub-directories. The first two characters of each file name is the abbreviation for the state the in which the file contains data for. After the abbreviation is the text which describes the contents of the file. Here is each file type described in detail: XXFullHarmonizedRights.csv: A file of the combined groundwater and surface water records for each state. Essentially, this file is the merging of XXGroundwaterHarmonizedRights.csv and XXSurfaceWaterHarmonizedRights.csv by state. The column headers for each of this type of file are: state - The name of the state the data comes from. FIPS - The two-digit numeric state ID code. waterRightID - The unique identifying ID of the water right, the same identifier as its state uses. priorityDate - The priority date associated with the right. origWaterUse - The original stated water use(s) from the state. waterUse - The water use category under the unified use categories established here. source - Whether the right is for surface water or groundwater. basinNum - The alpha-numeric identifier of the WMA the record belongs to. CFS - The maximum flow of the allocation in cubic feet per second (ft3s-1). Arizona is unique among the states, as its surface and groundwater resources are managed with two different sets of boundaries. So, for Arizona, the basinNum column is missing and instead there are two columns: surBasinNum - The alpha-numeric identifier of the surface water WMA the record belongs to. grdBasinNum - The alpha-numeric identifier of the groundwater WMA the record belongs to. XXStatePOD.shp: A shapefile which identifies the location of the Points of Diversion for the state's water rights. It should be noted that not all water right records in XXFullHarmonizedRights.csv have coordinates, and therefore may be missing from this file. XXStatePOU.shp: A shapefile which contains the area(s) in which each water right is claimed to be used. Currently, only Idaho and Washington provided valid data to include within this file. XXGroundwaterHarmonizedRights.csv: A file which contains only harmonized groundwater rights collected from each state. See XXFullHarmonizedRights.csv for more details on how the data is formatted. XXSurfaceWaterHarmonizedRights.csv: A file which contains only harmonized surface water rights collected from each state. See XXFullHarmonizedRights.csv for more details on how the data is formatted. Additionally, one file, stateWMALabels.csv, is not stored within a sub-directory. While we have referred to the spatial boundaries that each state uses to manage its water resources as WMAs, this term is not shared across all states. This file lists the proper name for each boundary set, by state. For those whom may be interested in exploring our code more in depth, we are also making available an internal data file for convenience. The file is in .RData format and contains everything described above as well as some minor additional objects used within the code calculating the cumulative curves. For completeness, here is a detailed description of the various objects which can be found within the .RData file: states: A character vector containing the state names for those states in which data was collected for. More importantly, the index of the state name is also the index in which that state's data can be found in the various following list objects. For example, if California is the third index in this object, the data for California will also be in the third index for each accompanying list. rightsByState_ground: A list of data frames with the cleaned ground water rights collected from each state. This object holds the the data that is exported to created the xxGroundwaterHarmonizedRights.csv files. rightsByState_surface: A list of data frames with the cleaned surface water rights collected from each state. This object holds the the data that is exported to created the xxSurfaceWaterHarmonizedRights.csv files. fullRightsRecs: A list of the combined groundwater and surface water records for each state. This object holds the the data that is exported to created the xxFullHarmonizedRights.csv files. projProj: The spatial projection used for map creation in the beginning of the project. Specifically, the World Geodetic System (WGS84) as a coordinate reference system (CRS) string in PROJ.4 format. wmaStateLabel: The name and/or abbreviation for what each state legally calls their WMAs. h2oUseByState: A list of spatial polygon data frames which contain the area(s) in which each water right is claimed to be used. It should be noted that not all water right records have a listed area(s) of use in this object. Currently, only Idaho and Washington provided valid data to be included in this object. h2oDivByState: A list of spatial points data frames which identifies the location of the Point of Diversion for the state's water rights. It should be noted that not all water right records have a listed Point of Diversion in this object. spatialWMAByState: A list of spatial polygon data frames which contain the spatial WMA boundaries for each state. The only data contained within the table are identifiers for each polygon. It is worth reiterating that Arizona is the only state in which the surface and groundwater WMA boundaries are not the same. wmaIDByState: A list which contains the unique ID values of the WMAs for each state. plottingDim: A character vector used to inform mapping functions for internal map making. Each state is classified as either "tall" or "wide", to maximize space on a typical 8x11 page. The code related to the creation of this dataset can be viewed within HarDWR GitHub Repository/dataHarmonization.

Economics↗

THE STAR FORMATION IN RADIO SURVEY: GBT 33 GHz OBSERVATIONS OF NEARBY GALAXY NUCLEI AND EXTRANUCLEAR STAR-FORMING REGIONS

We present 33 GHz photometry of 103 galaxy nuclei and extranuclear star-forming complexes taken with the Green Bank Telescope as part of the Star Formation in Radio Survey. Among the sources without evidence for an active galactic nucleus, and also having lower frequency radio data, we find a median thermal fraction at 33 GHz of Almost-Equal-To 76% with a dispersion of Almost-Equal-To 24%. For all sources resolved on scales {approx}<0.5 kpc, the thermal fraction is even larger, being {approx}>90%. This suggests that the rest-frame 33 GHz emission provides a sensitive measure of the ionizing photon rate from young star-forming regions, thus making it a robust star formation rate (SFR) indicator. Taking the 33 GHz SFRs as a reference, we investigate other empirical calibrations relying on different combinations of warm 24 {mu}m dust, total infrared (IR; 8-1000 {mu}m), H{alpha} line, and far-UV continuum emission. The recipes derived here generally agree with others found in the literature, albeit with a large dispersion that most likely stems from a combination of effects. Comparing the 33 GHz to total IR flux ratios as a function of the radio spectral index, measured between 1.7 and 33 GHz, we find that the ratio increases as the radio spectral index flattens which does not appear to be a distance effect. Consequently, the ratio of non-thermal to total IR emission appears relatively constant, suggesting only moderate variations in the cosmic-ray electron injection spectrum and ratio of synchrotron to total cooling processes among star-forming complexes. Assuming that this trend solely arises from an increase in the thermal fraction sets a maximum on the scatter of the non-thermal spectral indices among the star-forming regions of {sigma}{sub {alpha}{sup N}{sup T}}{approx}<0.13.

79 ASTRONOMY AND ASTROPHYSICS↗

On-the-Fly Generation of Differential Resonance Scattering Probability Distribution Functions for Monte Carlo Codes

Current Monte Carlo codes use one of three models: (1) the asymptotic scattering model, (2) the free gas scattering model, or (3) the S(α,β) model, depending on the neutron energy and the specific Monte Carlo code. This thesis addresses the consequences of using the free gas scattering model, which assumes that the neutron interacts with atoms in thermal motion in a monatomic gas in thermal equilibrium at material temperature, T. Most importantly, the free gas model assumes the scattering cross section is constant over the neutron energy range, which is usually a good approximation for light nuclei, but not for heavy nuclei where the scattering cross section may have several resonances in the epithermal region. Several researchers in the field have shown that the exact resonance scattering model is temperaturedependent, and neglecting the resonances in the lower epithermal range can under-predict resonance absorption due to the upscattering phenomenon mentioned above, leading to an over-prediction of keff by several hundred pcm. Existing methods to address this issue involve changing the neutron weights or implementing an extra rejection scheme in the free gas sampling scheme, and these all involve performing the collision analysis in the center-of-mass frame, followed by a conversion back to the laboratory frame to continue the random walk of the neutron. The goal of this paper was to develop a sampling methodology that (1) accounted for the energydependent scattering cross sections in the collision analysis and (2) was performed in the laboratory frame,avoiding the conversion to the center-of-mass frame. The energy dependence of the scattering cross section was modeled with even-ordered polynomials (2nd and 4th order) to approximate the scattering cross section in Blackshaw’s equations for the moments of the differential scattering PDFs. These moments were used to sample the outgoing neutron speed and angle in the laboratory frame on-the-fly during the random walk of the neutron. Results for criticality studies on fuel pin and fuel assembly calculations using methods developed in this dissertation showed very close comparison to results using the reference Dopplerbroadened rejection correction (DBRC) scheme.

42 ENGINEERING↗

Site and endmember spectra of terrestrial vegetation and soils for the Colorado Headwaters Ecological Spectroscopy Study, June-July 2025

This dataset provides site and endmember spectra collected during the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS) campaign. The site spectra were collected to help validate airborne hyperspectral data acquired by the National Ecological Observatory Network's aerial observation platform (NEON AOP). Endmember spectra were collected to augment existing spectral libraries with additional samples of bare surfaces and non-photosynthetic vegetation. All measurements were acquired with an Analytical Spectral Devices (ASD) FieldSpec4 Hi-Res NG (Next Generation) spectroradiometer, which records radiance at 1nm (nanometer) intervals from the ultraviolet to the short-wave infrared (350-2500 nm). The dataset includes spectra measured at meadow sites where the CHESS team also collected vegetation samples for trait analyses. The site spectra were collected with the ASD FieldSpec4 palm grip attachment using an 8° field-of-view foreoptic. Site spectra are integrated measurements of the entire surface within the foreoptic’s field of view. For site-level spectra, the sun is the illumination source. A Spectralon panel mounted on a tripod was used for instrument optimization and white reference measurements for all site spectra. Site spectra were acquired within two hours of solar noon and within 48 hours of a NEON AOP overflight. Site spectra are labeled by date, sampling area, and site number according to the naming conventions of the CHESS campaign’s data management plan. The dataset also contains endmember spectra in the following categories: photosynthetic vegetation (PV), non-photosynthetic vegetation (NPV), bare (soil/rock), and flowers. Endmember measurements were acquired using either the contact probe or the leaf clip attachments of the ASD FieldSpec4. In these configurations, the bulb inside the spectrometer provides the light source for the measurements. The spectrometer was optimized and white reference measurements were recorded using the circular white pucks attached to the contact probe and leaf clip. Because they do not rely on solar illumination, contact probe and leaf clip measurements were collected during a broader time frame than the palm grip site spectra. Some endmembers were measured at CHESS meadow sites, while others were collected within the larger sampling area or in nearby locations (e.g. Gothic Townsite) with similar characteristics. Radiance, reflectance, and metadata files are split into three subfolders according to measurement type: proximal/palm grip (prx), contact probe (cp), and leaf clip (lc). Radiance spectra are provided in ASD file format (.asd file extension). All ASD files can be opened using the provided scripts. Metadata is provided in two formats: CSV file format (no geolocation) and GEOJSON file format (includes geolocation for each spectra). The dataset includes a set of pre-processed reflectance spectra as CSV files (yyyymmdd_rfl.csv). The python scripts and jupyter notebook used to calculate reflectance spectra from the ASD radiance data is included here and was previously published at: https://doi.org/10.3334/ORNLDAAC/2446. There is also a folder of JPEG photographs corresponding to selected spectra. We include a protocol document with detailed steps for ASD FieldSpec4 assembly and operations. This data additionally contains a file level metadata (flmd.csv) and data dictionary (dd.csv) file. Geospatial information: Geospatial data for mapping measurement site locations are in the files CHESS_polygons_lai_UTM.geojson, CHESS_polygons_shrub_UTM.geojson, and CHESS_polygons_meadow_UTM.geojson in the companion geospatial package for the 2025 CHESS campaign, ‘CHESS 2025: Location data for field observations and sampling’ (Henderson et al., 2026). CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgment: This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (80NM0018D0004) and was funded by EMIT Extended Mission Phase E Science.

2018 NEON and 2025 CHESS Campaigns↗

A high resolution cavity BPM for the CLIC Test Facility

In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.

43 PARTICLE ACCELERATORS↗

Beam generation and planar imaging at energies below 2.40 MeV with carbon and aluminum linear accelerator targets

Purpose: Recent work has demonstrated improvement of image quality with low-Z linear accelerator targets and energies as low as 3.5 MV. In this paper, the authors lower the incident electron beam energy between 1.90 and 2.35 MeV and assess the improvement of megavoltage planar image quality with the use of carbon and aluminum linear accelerator targets. Methods: The bending magnet shunt current was adjusted in a Varian linear accelerator to allow selection of mean electron energy between 1.90 and 2.35 MeV. Linac set points were altered to increase beam current to allow experimental imaging in a practical time frame. Electron energy was determined through comparison of measured and Monte Carlo modeled depth dose curves. Planar image CNR and spatial resolution measurements were performed to quantify the improvement of image quality. Magnitudes of improvement are explained with reference to Monte Carlo generated energy spectra. Results: After modifications to the linac, beam current was increased by a factor greater than four and incident electron energy was determined to have an adjustable range from 1.90 MeV to 2.35 MeV. CNR of cortical bone was increased by a factor ranging from 6.2 to 7.4 and 3.7 to 4.3 for thin and thick phantoms, respectively, compared to a 6 MV therapeutic beam for both aluminum and carbon targets. Spatial resolution was degraded slightly, with a relative change of 3% and 10% at 0.20 lp/mm and 0.40 lp/mm, respectively, when reducing energy from 2.35 to 1.90 MV. The percentage of diagnostic x-rays for the beams examined here, ranges from 46% to 54%.Conclusion: It is possible to produce a large fraction of diagnostic energy x-rays by lowering the beam energy below 2.35 MV. By lowering the beam energy to 1.90 MV or 2.35 MV, CNR improves by factors ranging from 3.7 to 7.4 compared to a 6 MV therapy beam, with only a slight degradation of spatial resolution when lowering the energy from 2.35 MV to 1.90 MV.

07 ISOTOPE AND RADIATION SOURCES↗

CGRO/BATSE data support the new paradigm for GRB prompt emission and the new L{sub i}{sup nTh}–E{sub peak,i}{sup nTh,rest} relation

The paradigm for gamma-ray burst (GRB) prompt emission is changing. Since early in the Compton Gamma Ray Observatory (CGRO) era, the empirical Band function has been considered a good description of the keV–MeV γ-ray prompt emission spectra despite the fact that its shape was very often inconsistent with the theoretical predictions, especially those expected in pure synchrotron emission scenarios. We have recently established a new observational model analyzing data of the NASA Fermi Gamma-ray Space Telescope. In this model, GRB prompt emission would be a combination of three main emission components: (i) a thermal-like component that we have interpreted so far as emission from the jet photosphere, (ii) a non-thermal component that we have interpreted so far as either synchrotron radiation from the propagating and accelerated charged particles within the jet or reprocessed jet photospheric emission, and (iii) an additional non-thermal (cutoff) power law (PL) extending from low to high energies in γ-rays and most likely of inverse Compton origin. In this article we reanalyze some of the bright GRBs, namely GRBs 941017, 970111, and 990123, observed with the Burst And Transient Source Experiment (BATSE) on board CGRO with the new model. We conclude that BATSE data for these three GRBs are fully consistent with the recent results obtained with Fermi: some bright BATSE GRBs exhibit three separate components during the prompt phase with similar spectral parameters as those reported from Fermi data. In addition, the analysis of the BATSE GRBs with the new prompt emission model results in a relation between the time-resolved energy flux of the non-thermal component, F{sub i}{sup nTh}, and its corresponding νF{sub ν} spectral peak energy, E{sub peak,i}{sup nTh} (i.e., F{sub i}{sup nTh}–E{sub peak,i}{sup nTh}), which has a similar index—when fitted to a PL—as the one initially derived from Fermi data. For GRBs with known redshifts (z) this results in a possible universal relation between the luminosity of the non-thermal component, L{sub i}{sup nTh}, and its corresponding νF{sub ν} spectral peak energy in the rest frame, E{sub peak,i}{sup NT,rest} (i.e., L{sub i}{sup nTh}–E{sub peak,i}{sup NT,rest}). We estimated the redshifts of GRBs 941017 and 970111 using GRB 990123—with z = 1.61—as a reference. The estimated redshift for GRB 941017 is typical for long GRBs and the estimated redshift for GRB 970111 is right in the range of the expected values for this burst.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-456: Development of An EPID-Based Output Measurement and Dosimetric Verification Tool for Electron Beam Therapy

Purpose: To develop an efficient and robust method for output and absolute dosimetric measurements of electron beam therapy by using a high spatialresolution and high frame-rate amorphous silicon flat-panel electronic portal imaging device (EPID). Methods: A previously-established EPID dosimetry system was extended to measure the output factors of electron beams of various sizes and their planar dose distributions at reference depths. Specific EPID responses to different electron energies were derived from Monte Carlo (MC) simulations to de-convolve the EPID raw images to the incident electron fluence map. To reconstruct the 2D water-based dose distribution map at reference depths for different energies, the fluence map was further convolved with a MC simulated pencil beam kernel. Different energies of 6, 9, 12, 16, and 20 MeV from a Varian C-series linac were tested. Standard square fields ranging from 2×2 to 15×15 cm{sup 2} were measured and validated against film/ion chamber measurements. Small fields of different patient cases with irregular cutout shapes were also tested. Results: The EPIDmeasured output factors for 2×2, 3×3, 6×6, and 10×10 cm{sup 2} fields with all electron energies agree with the film/ion chamber data within 2.7%. The average discrepancy between EPID and film/ion chamber measurements was 1.4%. The differences for the three patient cases were 0.1%, 2.1%, and 1.6%. Deliveries with different monitor units were tested and the results exhibited good linearity. Measurements with different dose rate showed that the dose rate dependence was less than 1%. Using the proposed method, 2D absolute dose maps were created from the EPID raw images and the results were consistent with film measurements. Conclusion: The efficient data readout and portability of the newly developed EPID system provides an efficient and accurate solution for electron beam therapy. It addresses an important unmet clinical need for a fast and reliable small field output factor measurement.

07 ISOTOPE AND RADIATION SOURCES↗

ESIAS Pseudocode

The Explosive Shock Image Analysis System (ESAIS) is designed to provide a semiautomated quantitative analysis of fast-frame imagery taken during the detonation of high explosive (HE) rate sticks. ESIAS does this by assisting the user in identifying the HE stick geometry on the image (i.e., sides of the undetonated HE stick, detonation front, an axial reference point to assist in the inter-comparison of images); scaling the images based on the known diameter of the undetonated HE stick; identifying the profiles of various surfaces resulting from the detonation process such as the shock wave and product gases or the outer pipe surface; calculating the detonation speed of the HE by tracking the distance it travels between two images with a known time lapse between the images; and determining the slit velocities resulting from the detonation. ESIAS will also import scope traces from oscilloscopes and assist in identifying the time of arrival of significant peaks.

97 MATHEMATICS AND COMPUTING↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Bbar to Xu l nubar Decays in BBbar Events Tagged by a Fully Reconstructed B-meson Decay and Determination of |V_{ub}|

We report measurements of partial branching fractions for inclusive charmless semileptonic B decays {bar B} {yields} X{sub u}{ell}{bar {nu}}, and the determination of the CKM matrix element |V{sub ub}|. The analysis is based on a sample of 467 million {Upsilon}(4S) {yields} B{bar B} decays recorded with the BABAR detector at the PEP-II e{sup +}e{sup -} storage rings. We select events in which the decay of one of the B mesons is fully reconstructed and an electron or a muon signals the semileptonic decay of the other B meson. We measure partial branching fractions {Delta}{Beta} in several restricted regions of phase space and determine the CKM element |V{sub ub}| based on four different QCD predictions. For decays with a charged lepton momentum p*{sub {ell}} > 1.0 GeV in the B meson rest frame, we obtain {Delta}{Beta} = (1.80 {+-} 0.13{sub stat.} {+-} 0.15{sub sys.} {+-} 0.02{sub theo.}) x 10{sup -3} from a maximum likelihood fit to the two-dimensional M{sub X} - q{sup 2} distribution. Here, M{sub X} refers to the invariant mass of the final state hadron X and q{sup 2} is the invariant mass squared of the charged lepton and neutrino. From this measurement we extract |V{sub ub}| = (4.31 {+-} 0.25{sub exp.} {+-} 0.16{sub theo.}) x 10{sup -3} as the arithmetic average of four results obtained from four different QCD predictions of the partial rate. We separately determine partial branching fractions for {bar B}{sup 0} and B{sup -} decays and derive a limit on the isospin breaking in {bar B} {yields} X{sub u}{ell}{bar {nu}} decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effects of bias, drift, and trends in calculating anomalies for evaluating skill of seasonal-to-decadal initialized climate predictions

In initialized seasonal to decadal (S2D) predictions, model hindcasts rapidly drift away from the initial observed state and converge toward a preferred state characterized by systematic error, or bias. Bias and drift are among the greatest challenges facing initialized prediction today. Differences in trends between initial states and drifted states, combined with bias and drift, introduce complexities in calculating anomalies to assess skill of initialized predictions. We examine several methods of calculating anomalies using the Decadal Prediction Large Ensemble (DPLE) using the Community Earth System Model (CESM) initialized hindcasts and focus on Pacific and Atlantic SSTs to illustrate issues with anomaly calculations. Three methods of computing anomalies, one as differences from a long term model climatology, another as bias-adjusted differences from the previous 15 year average from observations, and a third as differences from the previous 15 year average from the model, are contrasted and each is shown to have limitations. For the first, trends in bias and drift introduce higher skill estimates earlier and later in the hindcast period due to the trends that contribute to skill. For the second, higher skill can be introduced in situations where low frequency variability in the observations is large compared to the hindcasts on timescales greater than 15 years, while lower skill can result if the predicted signal is small and the bias-correction itself produces a transition of SST anomalies to the opposite sign of those that are observed. The third method has somewhat lower skill compared to each of the others, but has less difficulties with not only the long term trends in the model climatology, but also with the unrealistic situational skill from using observations as a reference. However, the first 15 years of the hindcast period cannot be evaluated due to having to wait to accumulate the previous 15 year model climatology before the method can be applied. Here, the IPO transition in the 2014–2016 time frame from negative to positive (predicted by Meehl et al. in in Nat Commun, 10.1038/NCOMMS11718, 2016) did indeed verify using all three methods, though each provides somewhat different skill values as a result of the respective limitations. There is no clear best method, as all are roughly comparable, and each has its own set of limitations and caveats. However, all three methods show generally higher overall skill in the AMO region compared to the IPO region.

54 ENVIRONMENTAL SCIENCES↗

ATLAS (Automatic Tool for Local Assembly Structures) - A Comprehensive Infrastructure for Assembly, Annotation, and Genomic Binning of Metagenomic and Metaranscripomic Data

ATLAS (Automatic Tool for Local Assembly Structures) is a comprehensive multiomics data analysis pipeline that is massively parallel and scalable. ATLAS contains a modular analysis pipeline for assembly, annotation, quantification and genome binning of metagenomics and metatranscriptomics data and a framework for reference metaproteomic database construction. ATLAS transforms raw sequence data into functional and taxonomic data at the microbial population level and provides genome-centric resolution through genome binning. ATLAS provides robust taxonomy based on majority voting of protein coding open reading frames rolled-up at the contig level using modified lowest common ancestor (LCA) analysis. ATLAS provides robust taxonomy based on majority voting of protein coding open reading frames rolled-up at the contig level using modified lowest common ancestor (LCA) analysis. ATLAS is user-friendly, easy install through bioconda maintained as open-source on GitHub, and is implemented in Snakemake for modular customizable workflows.

genome binning↗

5G Energy FRAME Report on 5G for Grid Use Case (Year 3 Final Report)

This report provides an extensive overview of the interrelationships among energy, communication, and computing—especially in the context of decarbonization goals, challenges, and opportunities. Technical examples enabled by 5G technologies and their performance are presented, discussed, based on the experiment performed at Pacific Northwest National Laboratory. This is the first use case focused on using 5G for the U.S. power grid and will be referred to as the 5G for Grid Use Case from here on. Specifically, this use case looks at the workflow, which integrates the performance data of a real-world 5G communication testbed and a grid transmission and distribution co-simulation platform. The cross-domain information flow and logic design are illustrated with a combination of power grid contingencies and events. Lastly, a summary of the project achievement and outcome is provided, along with a technology roadmap envisioned by the project team.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WE-AB-303-07: Computational Monitoring Framework of Four-Dimensional Dose Distributions During Treatment Time Based On a 2D/3D Registration with Adaptive Transformation Parameters in Lung Stereotactic Body Radiotherapy

Purpose: The aim of this study was to develop a computational framework for monitoring four-dimensional (4D) dose distributions during treatment time based on a 2D/3D registration with adaptive transformation parameters (ATPs) in lung stereotactic body radiotherapy (SBRT). Methods: The 4D dose distributions during the SBRT were calculated by applying a pencil beam convolution (PBC) algorithm to simulated 4D-computed tomography (CT) images during treatment time (hereinafter referred to as “treatment” 4D-CT images). The “treatment” 4D-CT images were derived by deforming 3D planning CT images by using transformation parameters so that 2D planning portal dose images (PDIs) can resemble 2D dynamic clinical PDIs in each frame, which were derived from electronic portal imaging device (EPID) images. The transformation parameters were optimized by the Levenberg- Marquardt (LM) algorithm. The optimized transformation parameters in a certain frame were adaptively employed as initial transformation parameters for optimization of the parameters in the consecutive frame. Gamma pass rates (3mm/3%) between dynamic clinical PDIs and dynamic “treatment” PDIs derived from the “treatment” 4D-CT images were measured for comparing the proposed frameworks without and with the ATPs. These proposed frameworks were applied to the EPID dynamic images (40 frames) of two patients with lung cancer, who underwent the SBRT. Results: Gamma pass rates without and with the ATPs were 83.01±4.42% and 89.31±3.18% on average, respectively (p<0.05). Moreover, percentage errors between prescribed doses and estimated doses at an isocenter by the proposed frameworks without and with the ATPs were 10.67±5.66% and 6.34±0.47% on average, respectively (p<0.05). Conclusion: The proposed framework with ATPs could be useful to ensure the quality of the SBRT by monitoring 4D dose distributions during treatment time.

60 APPLIED LIFE SCIENCES↗

International Energy Agency 22 MW Offshore Reference Wind Turbine

The presentation will be used in a public webinar to introduce the newly developed 22 megawatt offshore reference wind turbine designed within the International Energy Agency Wind Technology Commercialization Programme Task 55 Reference Wind Turbines and Plants. The turbine was designed collaboratively by two teams at the Denmark Technical University and at the National Renewable Energy Laboratory. Reference turbines serve an important purpose in the wind energy community, since they provide openly available data for models representative of current wind turbine technology, which can be used by practitioners for a variety of modeling purposes, ranging from aerodynamic, structural, and aeroelastic turbine modeling to wind farm flow modeling, across a range of fidelities. The IEA 22 RWT aims to model machines with projected installation in the 2025-2030 time frame. The turbine has a rotor diameter of 284 meters and a hub height of 170 meters. It is a class 1-B machine with a rotor specific power nearing 350 W m-2 and it is mounted on either a fixed-bottom offshore foundation or a semi-submersible floating platform.

17 WIND ENERGY↗