Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Microwave radiometer, sun-photometer and GNSS multi-comparison of integrated water vapor in Southwestern Europe

This work presents a comparison of integrated water vapor (IWV) data recorded from microwave radiometer (MWR) and sun-photometer (SP) using global navigation satellite system (GNSS) IWV as reference in five mid-latitude sites of Portugal and Spain (2003–2021). A very high correlation is obtained for both instruments (R2 between 0.94 and 0.98), although, while MWR shows a wet bias, SP exhibits a dry one. In addition, a dependence of mean bias error (MBE) and standard deviation (SD) on IWV has been observed, increasing (larger discrepancies) both indices as IWV increases. The solar zenith angle (SZA) dependence is also studied, finding slightly larger discrepancies for the MWR than for SP in comparison with GNSS for very high values of SZA. Finally, a marked seasonal dependence is observed for SP-GNSS differences, modulated by the IWV dependence explained above. In contrast, the seasonal dependence for MWR is quite weaker than it is for SP. Therefore, in spite of the excellent agreement found among the different instruments, it is recommended that: i) the dependence with IWV be studied and corrected to further increase the performance of the instruments, and ii) metadata be used to filter out situations in which the instrument cannot operate properly.

54 ENVIRONMENTAL SCIENCES↗

Millimeter-wave radiometer diagnostics of harmonic electron cyclotron emission in the Levitated Dipole Experiment

A 110/137 GHz radiometer pair with collimated antenna pattern is being used to diagnose optically thin harmonic electron cyclotron emission from hot electrons in LDX. Signal levels of 0.1-1 keV and 110/137 ratios of 2-4 stationary with ECRH power have been observed. The large plasma core magnetic field gradient causes all relevant harmonics to be simultaneously viewed over a <(k,B) angular range of 0 deg. - 90 deg. representing a unique geometry for interpretation of ECE in terms of hot electron temperature and density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control

An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Divertor electron temperature and impurity diffusion measurements with a spectrally resolved imaging radiometer

A divertor imaging radiometer (DIR) diagnostic is being studied to measure spatially and spectrally resolved radiated power P{sub rad}({lambda}) in the tokamak divertor. A dual transmission grating design, with extreme ultraviolet ({approx}20-200 A) and vacuum ultraviolet ({approx}200-2000 A) gratings placed side-by-side, can produce coarse spectral resolution over a broad wavelength range covering emission from impurities over a wide temperature range. The DIR can thus be used to evaluate the separate P{sub rad} contributions from different ion species and charge states. Additionally, synthetic spectra from divertor simulations can be fit to P{sub rad}({lambda}) measurements, providing a powerful code validation tool that can also be used to estimate electron divertor temperature and impurity transport.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification of the collective Thomson scattering radiometer in the search for parametric decay on TEXTOR

Strong scattering of high-power millimeter waves at 140 GHz has been shown to take place in heating and current-drive experiments at TEXTOR when a tearing mode is present in the plasma. The scattering signal is at present supposed to be generated by the parametric decay instability. Here we describe the heterodyne detection system used to characterize the newly discovered signal measured at TEXTOR, and we present spectral shapes in which the signal can appear under different conditions. The radiation is collected by the receiver through a quasi-optical transmission line that is independent of the electron cyclotron resonance heating transmission line, and so the scattering geometry is variable. The signal is detected with 42 frequency channels ranging from 136 to 142 GHz. We demonstrate that the large signal does not originate from gyrotron spurious radiation. The measured signal agrees well with independent backscattering radiometer data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using a cold radiometer to measure heat loads and survey heat leaks

We have developed an inexpensive cold radiometer for use in thermal/vacuum chambers to measure heat loads, characterize emissivity and specularity of surfaces and to survey areas to evaluate stray heat loads. We report here the results of two such tests for the James Webb Space Telescope to measure heat loads and effective emissivities of 2 major pieces of optical ground support equipment that will be used in upcoming thermal vacuum testing of the Telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a 32 channel electron cyclotron emission radiometer on the HL-2A tokamak

A novel 32-channel electron cyclotron emission radiometer has been designed and tested for the measurement of electron temperature profiles on the HL-2A tokamak. This system is based on the intermediate frequency filter detection technique, and has the features of wide working frequency range and high spatial resolution. Two relative calibration methods have been investigated: sweeping the toroidal magnetic field and hopping the output frequency of the local oscillator. Preliminary results show that both methods can ensure reasonable profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and characterization of a 32-channel heterodyne radiometer for electron cyclotron emission measurements on experimental advanced superconducting tokamak

A 32-channel heterodyne radiometer has been developed for the measurement of electron cyclotron emission (ECE) on the experimental advanced superconducting tokamak (EAST). This system collects X-mode ECE radiation spanning a frequency range of 104–168 GHz, where the frequency coverage corresponds to a full radial coverage for the case with a toroidal magnetic field of 2.3 T. The frequency range is equally spaced every 2 GHz from 105.1 to 167.1 GHz with an RF bandwidth of ∼500 MHz and the video bandwidth can be switched among 50, 100, 200, and 400 kHz. Design objectives and characterization of the system are presented in this paper. Preliminary results for plasma operation are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute intensity calibration of the 32-channel heterodyne radiometer on experimental advanced superconducting tokamak

This paper presents the results of the in situ absolute intensity calibration for the 32-channel heterodyne radiometer on the experimental advanced superconducting tokamak. The hot/cold load method is adopted, and the coherent averaging technique is employed to improve the signal to noise ratio. Measured spectra and electron temperature profiles are compared with those from an independent calibrated Michelson interferometer, and there is a relatively good agreement between the results from the two different systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cut cell method for the 3D simulation of Crookes radiometer

Devices involved in engineering applications, such as vacuum pumps or MEMS, may be made of several moving parts. This raise the issue of the simulation of rarefied gas flow around moving boundaries. We propose a simple process, known as cut cell method, to treat the motion of a solid body in the framework of the deterministic solving of a kinetic equation. Up to our knowledge, this is the first time that this approach has been used for this kind of simulations. The method is illustrated by the 2D and 3D simulations of a Crookes radiometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Removing Biases from Rotating Shadowband Radiometers

Three types of biases are examined for a Rotating Shadowband Radiometer (RSR): temperature bias, spectral bias, and deviation from a Lambertian cosine response. A step by step method is presented to illustrate how to use this information to develop a model for adjustment algorithms for a RSR. Comparisons are made with a RSR adjusted using the model and measure direct normal, diffuse, and global irradiance.

14 SOLAR ENERGY↗

Design of a Shadowband Spectral Radiometer for the Retrieval of Thin Cloud Optical Depth, Liquid Water Path, and the Effective Radius

The design and operation of a Thin-Cloud Rotating Shadowband Radiometer (TCRSR) described here was used to measure the radiative intensity of the solar aureole and enable the simultaneous retrieval of cloud optical depth, drop effective radius, and liquid water path. The instrument consists of photodiode sensors positioned beneath two narrow metal bands that occult the sun by moving alternately from horizon to horizon. Measurements from the narrowband 415-nm channel were used to demonstrate a retrieval of the cloud properties of interest. With the proven operation of the relatively inexpensive TCRSR instrument, its usefulness for retrieving aerosol properties under cloud-free skies and for ship-based observations is discussed.

54 ENVIRONMENTAL SCIENCES↗

MWRRET Value-Added Product: The Retrieval of Liquid Water Path and Precipitable Water Vapor from Microwave Radiometer (MWR) Data Sets (Revision 2)

This report provides a short description of the Atmospheric Radiation Measurement (ARM) Climate Research Facility microwave radiometer (MWR) Retrieval (MWRRET) value-added product (VAP) algorithm. This algorithm utilizes a complementary physical retrieval method and applies brightness temperature offsets to reduce spurious liquid water path (LWP) bias in clear skies resulting in significantly improved precipitable water vapor (PWV) and LWP retrievals. We present a general overview of the technique, input parameters, output products, and describe data quality checks. A more complete discussion of the theory and results is given in Turner et al. (2007b).

54 ENVIRONMENTAL SCIENCES↗

Microwave Radiometer-High Frequency (MWRHF) Handbook

The 90/150-GHz Vapor Radiometer provides time-series measurements of brightness temperatures from two channels centered at 90 and 150 GHz. These two channels are sensitive to the presence of liquid water and precipitable water vapor.

54 ENVIRONMENTAL SCIENCES↗

Multifilter Rotating Shadowband Radiometer (MFRSR) Handbook

The visible Multifilter Rotating Shadowband Radiometer (MFRSR) is a passive instrument that measures global and diffuse components of solar irradiance at six narrowband channels and one open, or broadband, channel (Harrison et al. 1994). Direct irradiance is not a primary measurement, but is calculated using the diffuse and global measurements. To collect one data record, the MFRSR takes measurements at four different shadowband positions. The first measurement is taken with the shadowband in the nadir (home) position. The next three measurements are, in order, the first side-band, sun-blocked, and second side-band. The side-band measurements are used to correct for the portion of the sky obscured by the shadowband. The nominal wavelengths of the narrowband channels are 415, 500, 615, 673, 870, and 940 nm. From such measurements, one may infer the atmosphere's aerosol optical depth at each wavelength. In turn, these optical depths may be used to derive information about the column abundances of ozone and water vapor (Michalsky et al. 1995), as well as aerosol (Harrison and Michalsky 1994) and other atmospheric constituents.

54 ENVIRONMENTAL SCIENCES↗

Improved Rotating Shadowband Radiometer Measurement Performance: Cooperative Research and Development Final Report, CRADA Number CRD-08-294

Under this Agreement, NREL will work with Participant to improve rotating shadowband radiometer (RSR) performance characterizations. This work includes, but is not limited to, research and development for making the RSR a more accurate and fully characterized instrument for solar power technology development and commercial solar power project site assessment. Cooperative R&D is proposed in three areas: instrument calibration, instrument field configuration and operation, and measurement extrapolation and interpolation using satellite images. This work will be conducted at NREL and Participant facilities.

14 SOLAR ENERGY↗

Microwave Radiometer Profiler (MWRP) Instrument Handbook

The Microwave Radiometer Profiler (MWRP) provides time-series measurements of brightness temperatures from 12 channels between 22.235 and 58.80 GHz. These channels are sensitive to the presence of liquid water and precipitable water vapor and to the atmospheric temperature and humidity profile.

47 OTHER INSTRUMENTATION↗

Broadband Outdoor Radiometer Calibration (BORCAL) Process for the Atmospheric Radiation Measurement (ARM) Program: Second Edition

The Atmospheric Radiation Measurement program (ARM) maintains a fleet of monitoring stations to aid in the improved scientific understanding of the basic physics related to radiative feedback processes in the atmosphere, particularly the interactions among clouds and aerosols. ARM obtains continuous measurements and conducts field campaigns to provide data products that aid in the improvement and further development of climate models. All of the measurement campaigns include a suite of solar measurements. The Solar Radiation Research Laboratory at the National Renewable Energy Laboratory supports ARM's full suite of stations in a number of ways, including troubleshooting issues that arise as part of the data-quality reviews; managing engineering changes to the standard setup; and providing calibration services and assistance to the full fleet of solar-related instruments, including pyranometers, pyrgeometers, pyrheliometers, as well as the temperature/relative humidity probes, multimeters, and data acquisition systems that are used in the calibrations performed at the Southern Great Plains Radiometer Calibration Facility. This paper discusses all aspects related to the support provided to the calibration of the instruments in the solar monitoring fleet.

14 SOLAR ENERGY↗