Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Energy Performance Comparison of Heating and Air Conditioning Systems for Multi-Family Residential Buildings

The type of heating, ventilation and air conditioning (HVAC) system has a large impact on the heating and cooling energy consumption in multifamily residential buildings. This paper compares the energy performance of three HVAC systems: a direct expansion (DX) split system, a split air source heat pump (ASHP) system, and a closed-loop water source heat pump (WSHP) system with a boiler and an evaporative fluid cooler as the central heating and cooling source. All three systems use gas furnace for heating or heating backup. The comparison is made in a number of scenarios including different climate conditions, system operation schemes and applicable building codes. It is found that with the minimum code-compliant equipment efficiency, ASHP performs the best among all scenarios except in extremely code climates. WSHP tends to perform better than the split DX system in cold climates but worse in hot climates.

15 GEOTHERMAL ENERGY↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

Geothermal Energy Retrofit

The Cleary University Geothermal Energy Retrofit project involved: 1. A thermal conductivity test; 2. Assessment of alternative horizontal and vertical ground heat exchanger options; 3. System design; 4. Asphalt was stripped from adjacent parking areas and a vertical geothermal ground heat exchanger system installed; 5. the ground heat exchanger was connected to building; 6. a system including 18 heat pumps, control systems, a manifold and pumps, piping for fluid transfer and ductwork for conditioned air were installed throughout the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fine-particle filter prevents damage to vacuum pumps

A filter system for mechanical pumps is designed with a baffle assembly that rotates in a circulating oil bath which traps destructive particles. This prevents severe damage to the pump and is serviceable for long periods before it requires cleaning.

Harlamert, P., Jr.↗

Mean Line Pump Flow Model in Rocket Engine System Simulation

A mean line pump flow modeling method has been developed to provide a fast capability for modeling turbopumps of rocket engines. Based on this method, a mean line pump flow code PUMPA has been written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The pump code can model axial flow inducers, mixed-flow and centrifugal pumps. The code can model multistage pumps in series. The code features rapid input setup and computer run time, and is an effective analysis and conceptual design tool. The map generation capability of the code provides the map information needed for interfacing with a rocket engine system modeling code. The off-design and multistage modeling capabilities of the code permit parametric design space exploration of candidate pump configurations and provide pump performance data for engine system evaluation. The PUMPA code has been integrated with the Numerical Propulsion System Simulation (NPSS) code and an expander rocket engine system has been simulated. The mean line pump flow code runs as an integral part of the NPSS rocket engine system simulation and provides key pump performance information directly to the system model at all operating conditions.

Veres, Joseph P.↗

Two-Step Multi-Physics Analysis of an Annular Linear Induction Pump for Fission Power Systems

One of the key technologies associated with fission power systems (FPS) is the annular linear induction pump (ALIP). ALIPs are used to circulate liquid-metal fluid for transporting thermal energy from the nuclear reactor to the power conversion device. ALIPs designed and built to date for FPS project applications have not performed up to expectations. A unique, two-step approach was taken toward the multi-physics examination of an ALIP using ANSYS Maxwell 3D and Fluent. This multi-physics approach was developed so that engineers could investigate design variations that might improve pump performance. Of interest was to determine if simple geometric modifications could be made to the ALIP components with the goal of increasing the Lorentz forces acting on the liquid-metal fluid, which in turn would increase pumping capacity. The multi-physics model first calculates the Lorentz forces acting on the liquid metal fluid in the ALIP annulus. These forces are then used in a computational fluid dynamics simulation as (a) internal boundary conditions and (b) source functions in the momentum equations within the Navier-Stokes equations. The end result of the two-step analysis is a predicted pump pressure rise that can be compared with experimental data.

Fission Power Systems↗

Two-Step Multi-Physics Analysis of an Annular Linear Induction Pump for Fission Power Systems

One of the key technologies associated with fission power systems (FPS) is the annular linear induction pump (ALIP). ALIPs are used to circulate liquid-metal fluid for transporting thermal energy from the nuclear reactor to the power conversion device. ALIPs designed and built to date for FPS project applications have not performed up to expectations. A unique, two-step approach was taken toward the multi-physics examination of an ALIP using ANSYS Maxwell 3D and Fluent. This multi-physics approach was developed so that engineers could investigate design variations that might improve pump performance. Of interest was to determine if simple geometric modifications could be made to the ALIP components with the goal of increasing the Lorentz forces acting on the liquid-metal fluid, which in turn would increase pumping capacity. The multi-physics model first calculates the Lorentz forces acting on the liquid metal fluid in the ALIP annulus. These forces are then used in a computational fluid dynamics simulation as (a) internal boundary conditions and (b) source functions in the momentum equations within the Navier-Stokes equations. The end result of the two-step analysis is a predicted pump pressure rise that can be compared with experimental data.

Fission Power Systems↗

System Modeling of Gas Engine Driven Heat Pump

To improve the system performance of the GHP, modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated by using ORNL Modulating Heat Pump Design Software, which is used to predict steady-state heating and cooling performance of variable-speed vapor compression air-to-air heat pumps for a wide range of operational variables. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using desiccant system regenerated by waste heat from engine, the SHR can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% in rated operating conditions.

Gas Driven Heat Pump↗

Brief Update on Advancements by Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction

In 2011, Pacific Northwest National Laboratory (PNNL), working as a partner in the National Advanced Biofuels Consortium, issued a report assessing the viable industrial feed system and pump options for a 2000 dry metric tons per day production-scale hydrothermal liquefaction (HTL) plant (Berglin et al. 2012). This report was issued as PNNL-21981, Review and Assessment of Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction, and will be referred to as “Pump Survey” for reference. It had the following scope: • Identify relevant applications and industries operating at comparable scales • Interact with commercial vendors and pursue integration between vendors • Take advantage of commercial off-the-shelf (COTS) technology • Supply and support vendor needs for biomass feedstock rheology characterization • Provide vendors with process requirements to support selection of conceptual design for feedstock handing and pump system • Obtain cost data to the extent possible from equipment vendors to support the technical economic analysis (TEA) • Identify issues associated scale-up. The current document represents an update to the prior report in order to: 1. Identify advancements in vendor-reported technologies 2. List reports of new experience or trials with biomass pumping applications 3. Determine if technology/application gaps identified in the prior report have been filled 4. Capture ideas on future research.

09 BIOMASS FUELS↗

Development of Alternative Vacuum Pumps for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. The pumps would need to operate at lower rotational speeds to handle higher pressures and flow rates, which is best suited for Molecular Drag Pumps (MDP). To determine this, the vacuum pump characteristics must be determined for the MDP. This report details pump characteristics using an MDP backed by a Metal Bellows (Met-Bel) pump under static and flow conditions for various gases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of Accumulators and Liquid/Gas Charging of Single Phase Mechanically Pumped Fluid Loop Heat Rejection Systems

For single phase mechanically pumped fluid loops used for thermal control of spacecraft, a gas charged accumulator is typically used to modulate pressures within the loop. This is needed to accommodate changes in the working fluid volume due to changes in the operating temperatures as the spacecraft encounters varying thermal environments during its mission. Overall, the three key requirements on the accumulator to maintain an appropriate pressure range throughout the mission are: accommodation of the volume change of the fluid due to temperature changes, avoidance of pump cavitation and prevention of boiling in the liquid. The sizing and design of such an accumulator requires very careful and accurate accounting of temperature distribution within each element of the working fluid for the entire range of conditions expected, accurate knowledge of volume of each fluid element, assessment of corresponding pressures needed to avoid boiling in the liquid, as well as the pressures needed to avoid cavitation in the pump. The appropriate liquid and accumulator strokes required to accommodate the liquid volume change, as well as the appropriate gas volumes, require proper sizing to ensure that the correct pressure range is maintained during the mission. Additionally, a very careful assessment of the process for charging both the gas side and the liquid side of the accumulator is required to properly position the bellows and pressurize the system to a level commensurate with requirements. To achieve the accurate sizing of the accumulator and the charging of the system, sophisticated EXCEL based spreadsheets were developed to rapidly come up with an accumulator design and the corresponding charging parameters. These spreadsheets have proven to be computationally fast and accurate tools for this purpose. This paper will describe the entire process of designing and charging the system, using a case study of the Mars Science Laboratory (MSL) fluid loops, which is en route to Mars for an August 2012 landing.

HRS↗

Alternative All-Metal Scroll Pump Design

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. There have been development efforts to design an all-metal scroll pump design alternative to the Normetex style. The first generation was fabricated out of machined stainless steel, but the thermal management and increased weight were not ideal. To mitigate the weight, an aluminum version was designed. The tritium holdup on untreated aluminum surfaces can be greater than stainless steel, so the wetted aluminum surfaces were electroless plated in nickel and then electroplated in gold. The development effort outlined in this report details the design of an improved version of the stainless steel version.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis and Modeling of a Two-Phase Jet Pump of a Thermal Management System for Aerospace Applications

Jet pumps are devices capable of pumping fluids to a higher pressure by inducing the motion of a secondary fluid employing a high speed primary fluid. The main components of a jet pump are a primary nozzle, secondary fluid injectors, a mixing chamber, a throat, and a diffuser. The work described in this paper models the flow of a two-phase primary fluid inducing a secondary liquid (saturated or subcooled) injected into the jet pump mixing chamber. The model is capable of accounting for phase transformations due to compression, expansion, and mixing. The model is also capable of incorporating the effects of the temperature and pressure dependency in the analysis. The approach adopted utilizes an isentropic constant pressure mixing in the mixing chamber and at times employs iterative techniques to determine the flow conditions in the different parts of the jet pump.

Sherif, S.A.↗

Modeling and Simulation of Ternary Pumped Storage Hydropower for Power System Studies

As the deployment of wind and solar energy increases in the United States, energy storage (ES) will play an important role in future electric power grids. To help manage the variability from high penetration levels of renewable generation, ES can provide promising power/energy demand to coordinate with renewables generation, as a virtual power plant (VPP). There is an industry need for the capability in power system studies to model ternary pumped storage hydropower (T-PSH) that offers increased system benefits. This paper presents a comprehensive vendor-neutral dynamic model of T-PSH in GE's commercial software positive sequence load flow (PSLF). A new governor model is developed with detailed gate valve modeling and a shared-penstock function. Specifically, this model is designed to simulate the seamless transition among three operation modes: generation mode, pumping mode, and hydraulic short-circuit mode. The developed T-PSH model has been tested and validated on a 10-bus test system. A comparison study of T-PSH to conventional pumped storage hydropower has also been conducted on the Western Interconnection system.

13 HYDRO ENERGY↗

Options for low–global-warming-potential and natural refrigerants- Performance for heat pump application and analysis of systemic irreversibilities

There is growing interest in substituting existing refrigerants with low global warming potential (GWP) refrigerants, including naturally occurring fluids, to reduce the impact of human activities on climate change. In this study we have evaluated prospective low-GWP refrigerants in four distinct heat pump cycles using the First and Second laws of thermodynamics. The essence of the study is to establish the performance of the low-GWP refrigerants when deployed in a heat pump system. Exergy analysis provides a true measure of lost work, or systemic inefficiencies, vividly quantifying areas of improvement and identifying the preferred cycle for a refrigerant. The combined knowledge of the properties of the phase boundary on either side of the critical point (DOI:10.1.18462/iir.icr.2019.442), and exergy analysis of prospective cycles is necessary for a better perspective on discriminating among refrigerants as hydrochlorofluorocarbons are phased out and replacement refrigerants must be found.

Nawaz, Kashif↗

Recent Experiences Calculating g-functions for Use in Simulation of Ground Heat Exchangers

Temperature response functions, known as g-functions, are a computationally efficient method for simulating ground heat exchangers (GHEs), used with ground-source heat pump (GSHP) systems, either as part of a whole-building energy simulation or as part of a dedicated ground heat exchanger design tool. In fact, at present, they are the only feasible way to simulate a ground-source heat pump system in a whole-building energy simulation. This paper summarizes recent developments in the field and recent experience using a new open-source g-function calculation tool known as pygfunction (Cimmino 2018a, 2018b). This experience includes accuracy, computation time, memory requirements and sensitivity to boundary conditions. With larger ground heat exchangers, e.g. in excess of 100 boreholes, the computational time and memory requirements can create challenges.

Spitler, Jeffery↗