Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Optoelectronic property comparison for isostructural Cu 2 BaGeSe 4 and Cu 2 BaSnS 4 solar absorbers

To target mitigation of anti-site defect formation in Cu 2 ZnSnS 4–x Se x , a new class of chalcogenides, for which Ba or Sr (group 2) replace Zn (group 12), has recently been introduced for prospective solar absorber application. Cu 2 BaGeSe 4 (CBGSe) and Cu 2 BaSnS 4 (CBTS) are two such compounds, which share a common trigonal crystal structure (P3 1 space group) and similar quasi-direct band gap (~2 eV). While CBTS-based films have already been studied, there are no reports yet on films and solar cells based on related CBGSe. To identify key differences and similarities in the electronic properties between these two materials, electronic characteristics (e.g., carrier concentration, mobility, electron affinity, defect levels, recombination, and charge carrier kinetics) of vacuum-deposited CBGSe and CBTS films are compared using a variety of characterization methods. Hall effect measurements reveal that CBGSe films have relatively higher hole carrier concentration and lower mobility (3 × 10 15 cm –3 , 0.6 cm 2 V –1 s –1 ) compared to CBTS (5 × 10 12 cm –3 , 3.5 cm 2 V –1 s –1 ). Photoelectron spectroscopy yields low electron affinity values for both CBGSe (3.7 eV) and CBTS (3.3 eV), pointing to the necessity of pursuing low electron affinity buffer materials for both types of absorbers. At low temperatures, CBGSe films show free-exciton photoluminescence, as well as pronounced deep-level emission at ~1.4 eV, while CBTS films exhibit a strong bound-exciton signal with noticeably less intense deep-level emission than for CBGSe. Charge carrier kinetics, transport, and recombination properties of both types of films are also analyzed using optical-pump terahertz-probe spectroscopy and time-resolved microwave conductivity. The first CBGSe prototype solar cells (using chemical bath deposited CdS as a buffer layer) show a maximum of 1.5% efficiency with ~0.62 V open-circuit voltage. Furthermore, the measured properties point to possible limiting factors for CBGSe and related films for PV and optoelectronics and provide insights on possible approaches for improvement within this multinary chalcogenide family.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure feedback control of electro-hydraulic actuators using fixed displacement hydraulic machines

This paper presents the development of a control strategy for Electro-Hydraulic Actuator (EHA) systems based on fixed displacement hydraulic machines. Although some previous studies on EHAs show benefits in terms of energy efficiency and regeneration capability compared to conventional hydraulic systems, few studies focus on the dynamic performance of EHAs. Unlike traditional valve-controlled systems, an EHA based on a fixed displacement pump typically relies on variation of the electric motor shaft speed to control the actuator velocity. This study shows that pressure feedback can be used to control the speed of the electric machine, thus achieving the required actuator/machine dynamic response. A simulation model is developed by including the EM, the hydraulic system, and the actuation system, which can give a realistic prediction of the EHA performance for a typical duty cycle. An open-circuit EHA previously proposed by the authors is used to validate the control strategy, and the simulation results show superior dynamic performance, exhibiting a reduction in response time and oscillatory behavior, compared to a feedforward EHA controller. Following the method presented in this study, it is possible to design a controller with a pressure feedback strategy for EHA systems with different size and actuation requirements

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand reduction and energy saving potential of thermal energy storage integrated heat pumps [Réduction de la demande et potentiel d'économie d'énergie des pompes à chaleur avec stockage d'énergie thermique intégré]

A heat pump (HP) moves heat from a low-temperature source to a high-temperature sink with an input of energy. Often, one temperature body fluctuates with time (e.g., diurnal ambient temperature), causing the HP efficiency to vary. Integrating thermal energy storage (TES) into a HP system adds a third temperature body, enabling the HP to be advantageously coupled to any two: the application, the ambient, or the TES at strategic times. Although TES integration with HPs is an important emerging technology to lower energy consumption and decrease energy demand during critical times, the favorable circumstances for TES integration are poorly understood. Here, this paper establishes the energy reduction and demand reduction potential of TES-integrated HPs with both analytical and numerical HP models. All possible temperature arrangements are considered for HP-TES systems with two fixed temperature bodies (application and TES) and one variable temperature (ambient). Results show that overall energy savings are most attainable when the TES temperature is near the application temperature, whereas a large temperature difference between the TES and the application leads to the most peak demand reduction. The potential for overall energy savings increases as the magnitude of ambient temperature fluctuations increases.

25 ENERGY STORAGE↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Performance of pumped counterflow virtual impactors to study aerosol interactions with laboratory generated warm clouds

Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.

54 ENVIRONMENTAL SCIENCES↗

Maximizing the Use of Ductless Mini-Splits in Homes with Existing Central or Zonal Heating and Cooling Equipment

In the residential retrofit application, ductless mini-split heat pumps (DHP) are often reported to hold high-energy savings potential, depending on the system they are supplementing or replacing. However, of late, there have been a number of studies and analyses indicating these energy savings are not being achieved. The primary goal of this project was to determine the most cost effective (lowest cost for the most energy saved) and persistent (e.g. automated, hard to change, etc.) solution for controlling a ductless heat pump in an existing home with central forced air furnace. Various control strategies were tested at the Pacific Northwest National Laboratory Lab Homes to compare the energy savings between the different energy efficient control strategies. A maximum of 40% energy savings was realized by using the ductless mini-split as the primary heat source with the central air conditioning unit as the secondary source.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comparative study on deep learning models for condition monitoring of advanced reactor piping systems

Advanced nuclear reactors offer innovative applications due to their portability, reliability, resiliency, and high capacity factors. To operate them on a wider scale, reducing maintenance life-cycle costs while ensuring their integrity is essential. Autonomous operations in advanced nuclear reactors using augmented Digital Twin (DT) technology can serve as a cost-effective solution by increasing awareness about the system’s health. A key component of nuclear DT frameworks is the condition monitoring of safety systems, such as piping-equipment systems, which involves acquiring and monitoring the plant’s sensor data. Here, this research proposes a condition monitoring methodology utilizing deep learning algorithms, such as multilayer perceptions (MLP) and convolutional neural networks (CNNs), to detect degradation and its severity in nuclear piping-equipment systems. Sensor signals are processed to obtain the power spectral density and the Short-Time Fourier transform, and feature extraction methodologies are proposed to develop degradation-sensitive data repositories. The performance of MLP, one-dimensional (1D) CNN, and 2D CNN within the proposed condition monitoring framework is compared using a finite element model of a 3D piping system subjected to seismic loads as the application case study. Various approaches, such as dropout, k-Fold validation, regularization, and early stopping of training the network, are investigated to avoid overfitting the models to the input sensor data. The predictive capability and computational capacity of the deep learning algorithms are also compared to detect degradation in the Z-pipe system of the Experimental Breeder Reactor II (EBRII). The Z-pipe system is subjected to harmonic excitations that represent normal operating loads, such as pump-induced vibrations. The findings of the study indicate that the proposed artificial intelligence (AI)-driven condition monitoring framework demonstrates superior prediction accuracies with a 2D CNN, whereas the MLP exhibits higher computational efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Decarbonization Technology Snapshot: Heat Pump Water Heaters

Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. In many cases they replace gas-fired water heaters and are significantly more energy efficient, reducing on-site Scope 1 emissions and often resulting in reduced total emissions.

building decarbonization↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

Closed Loop Pumped Storage Hydropower Resource Assessment of the United States

The data includes a geospatial and spreadsheet representation of a resource analysis for closed loop pumped storage systems across the Continental United States, Alaska, Hawaii, and Puerto Rico. The data includes energy storage potential, water volume, distance from source to storage, hydraulic head, dollars per kilowatt of storage, and transmission spurline cost for each pumped storage hydropower (PHS) reservoir. Each reservoir represented in this dataset is represented on potential 10 hour storage duration PSH system comprised of two reservoirs. Units of measure are laid out in the dataset. Pumped storage hydropower (PSH) represents the bulk of the United States' current energy storage capacity: 23 gigawatts (GW) of the 24 GW national total (Denholm et al. 2021). This capacity was largely built between 1960 and 1990. PSH is a mature and proven method of energy storage with competitive round-trip efficiency and long life spans. These qualities make PSH a very attractive potential solution to energy storage needs, particularly for longer-duration storage (8 hours or more); such storage will be crucial to bridge gaps in electricity production as variable wind and solar production continue to comprise an ever-larger portion of the United States' energy portfolio. This study seeks to better understand the technical potential for PSH development in the United States by developing a national-scale resource assessment for closed-loop PSH. For more information, please refer to the Closed Loop Pumped Storage Hydropower Resource Assessment for the United States linked in the resources.

Array↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Slope Efficiency and Voltage Reduction at High Current Densities in AlInGaAs Diode Lasers

Here, the slope efficiency and drive voltage of broad area AlInGaAs laser diodes near 865 nm is observed to decrease significantly under quasi-CW pulsed operation at currents well above threshold, in a manner that cannot be explained by thermal effects or carrier leakage over heterojunction barriers. Simulations show that the slope efficiency reduction is explicable by increased free carrier absorption in the waveguide region. Empirical formulas are presented to represent these effects in a closed analytic form suitable for use in simulators for diode-pumped laser systems.

47 OTHER INSTRUMENTATION↗

Enabling off-highway diesel engine downsizing and performance improvement using electrically assisted turbocharging

Internal combustion engine (ICE) downsizing through various turbocharging configurations is generally known by the powertrain design community as an effective means to reduce frictional losses, increase waste heat recovery, and improve fuel efficiency while increasing engine power density. However, often is the case that turbocharging strategies, including variable geometry turbochargers, and regulated two-stage turbochargers, incur the performance tradeoff between transient response and fuel economy (pumping losses) at high engine speeds. For off-highway vehicles having particularly transient and high-powered duty cycles, efforts to improve this tradeoff and increase operational flexibility have turned to evaluating various electrified air system architectures. In this study, a 4.5 L diesel-ICE configured with an electrically driven compressor (eBooster ® ) is placed in series with a conventional turbocharger and integrated into a 48 V mild-hybrid powertrain architecture. The objective of this powertrain configuration is to enable engine downsizing by 34%, replacing the current 6.8 L ICE platform with the hybridized 4.5 L ICE concept. The commercial 1-D simulation software GT-SUITE is used for powertrain system development and system optimization. Development and validation of the GT-SUITE model and air system controls is concurrently supported through experimental data collection. The simulation model development includes using machine learning methods for optimizing exhaust gas dilution, injection timing, and eBooster ® power to improve steady-state and transient brake-specific fuel consumption while minimizing criteria pollutant emissions. It was found that total specific fluid consumption over the standardized non-road transient engine duty cycle could be reduced by 18% over the current 6.8 L engine by using an optimized eBoosted 4.5 L engine. The hybridized 4.5 L engine concept concurrently showed sufficient transient response capability and nearly an order of magnitude reduction in duty cycle total soot production.

25 ENERGY STORAGE↗

1 GW peak power and 100 J pulsed operation of a diode-pumped Tm:YLF laser

We report on the generation of high energy, high power pulses in a tabletop diode-pumped Tm:YLF-based laser system, which delivers amplified pulse energies up to 108 J, as well as GW peak power performance when seeded with nanosecond duration pulses. Furthermore, the high power and efficiency capabilities of operating Tm:YLF in the multi-pulse extraction (MPE) regime were explored by seeding the experimental setup with a multi-kHz burst of pulses exhibiting a low individual pulse fluence, resulting in a 3.6 kW average power train of multi-joule-level pulses with an optical-to-optical efficiency of 19%.

47 OTHER INSTRUMENTATION↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗

The Future Role of Hydropower in the Northeastern United States: May 2020-May 2022

This paper explores the future role of hydropower in the Northeastern US and beyond. The intent is to provide experience-based insights into how hydropower can best support the reliable and economic evolution of the New England power system and, more broadly, all US grids. Many of the challenges facing New England are driven by the potential integration of 10s of GWs of variable energy resources. Hydro can assist in remediating several issues, and the paper explores how Hydro might hit above its weight in a future low carbon New England system. Hydro can assist in handling periods of over generation, reduce the risk of curtailment of zero carbon resources, improve market efficiency, and provide valuable essential reliability services.

13 HYDRO ENERGY↗