Scale-Up of Electrode Coating and Flow-Field for Commercial Hydrogen Peroxide Electrolyzer: Cooperative Research and Development Final Report, CRADA Number CRD-17-00687

Hydrogen peroxide is currently produced at central chemical plants via the anthraquinone oxidation process. This process produces environmental pollutants that are costly to remediate, requires hazardous long distance shipping of highly concentrated peroxide (50% or 70%), and necessitates extra handling costs related to storage and dilution. Peroxygen Systems, Inc. (PSi) is developing breakthrough technology for on-site hydrogen peroxide production. PSi’s on-site on-demand electrolyzer can reduce the cost of producing hydrogen peroxide by 50%, while also completely eliminating the cost and safety issues associated with shipping and handling of high concentration hydrogen peroxide. The challenge for PSi is scaling. To support the next step toward commercialization (customer pilot tests), scaling the prototype into larger single cells and 20-40 cell stacks is required. In addition to internal hardware and flow-field design efforts at PSi, NREL will address three critical problems for this scale-up effort: (1) demonstrating a large scale roll-to-roll (R2R) process to coat uniform electrode materials for 100 cm2 and 500 cm2 stack testing, (2) demonstrating an in-line diagnostic to achieve better electrode quality control, and (3) performing in situ cell/stack testing to better understand and optimize the performance of the flow field design.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Design, optimization, and validation of a triply periodic minimal surface based heat exchanger for extreme temperature applications

Heat exchanger (HX) innovation offers potential for significant improvements in energy efficiency for a host of applications including but not limited to aviation and power generation cycles. Triply Periodic Minimal Surfaces (TPMS) have received significant attention in recent years due to their incredibly high surface area density, which makes them very attractive from a heat transfer point of view. Recent efforts have largely focused on thermal-hydraulic characterization of the many available TPMS and the testing of small-scale HX prototypes. However, practical implementation remains largely unexplored, partially due to the extreme computational cost associated with accurately simulating these complex structures. In this work, we present the design, simulation, and optimization of a TPMS-HX for high temperature (900 °C) and pressure (25 MPa) applications. Detailed analysis of HX sub-sections is conducted to define the smallest repeatable section which may be used to characterize the thermal-hydraulic performance of the entire HX, enabling rapid design and iteration with significantly reduced computational cost. Compared to preliminary results for a water-to-water experiment, calibrated heat transfer and pressure drop predictions were within ±5 % and ±10 %, respectively. Optimization results show a 10x increase in volumetric power density over the initial design, which is verified against a parametric exhaustive search of the HX design space. Furthermore, it was found that reducing the unit cell hydraulic diameter cell plays the largest role in increasing heat transfer, increasing the surface area density and enabling a more compact and efficient HX.

42 ENGINEERING↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Digitalization, Management and Synthesis of Thermal Hydraulic Legacy Data Using Dynamical System Scaling

A unique attribute of the nuclear industry is the extent by which designers, developers, operators, and regulators pay attention to demonstrating the safety case. The safety case for nuclear systems is a written, traceable expression of safety, demonstrating the system’s protective measures against uncontrolled radiological releases. The nuclear installation resiliency or safety takes overriding priority over function and performance. The preparation of the safety case heavily relies on extensive experimental campaigns that challenge the target design under a spectrum of postulated accident scenarios. For safety reasons, these experiments are typically conducted in sub-scale test apparatuses intended to reproduce the postulated accident scenarios and event sequences realistically but subject to proven similarity criteria, often referred to as scaling analyses. Since the dawn of the nuclear industry, significant resources have been committed to the construction and operation of such test facilities and a massive amount of data has been generated. Such test data have been and are still used to validate the fundamental assumptions of nuclear power plant phenomena. As we move into the digital world, capturing this multi-decades worth of information in a transparent, easily accessible, and usable manner for the public and industry stakeholders is of paramount importance. Over the last few years FPoliSolutions has been actively developing an enterprise digital data ontology platform (FPoliDON) intended to do just that. The concept was introduced in a paper at the previous NURETH edition and has been significantly enhanced since. With the vision of helping designers use the data to assess their safety case evaluation models, the platform was designed not only to ontologically organize the experimental data, but also to guide the user in the complex analytics associated with the interpretation and use of such test results. A new feature which has been recently added is the ability for the user to access a library of sophisticated mathematical procedures for performing scaling analyses. For this purpose, the Dynamical System Scaling (DSS) procedure invented by Dr. Jose’ Reyes was formulated as one of the services in the digital platform. These methods have been demonstrated to provide an excelled mathematical apparatus to identify similarity criteria or quantify distortions between measured data and the target prototypical conditions. Moreover, DSS can provide a level of synthesis across SETs and IETs which has the promise to yield efficiency in the evaluation code assessment activities. This is often a daunting and expensive task to set up evaluation models that support the safety case of current and future nuclear power plants.

Reyes, Jose↗

Real-time Multi-granular Analytics Framework for HIT Systems

Streaming analytics is the process of ingesting and digesting live data from multiple data sources. In the healthcare domain, as the importance of extracting immediate insights while data are streaming into the system grows, the focus is shifting from batch processing to streaming analytics. With data increasing dramatically at high speeds, many informatics designs have been proposed to adapt healthcare domain into this new environment. In our previous work, we introduced a prototype of health informatics technology (HIT) framework that aims to address challenges in adopting state-of-the-art technologies to enable advanced healthcare analytic tasks in new streaming environments. We recently made major updates to the framework so that anomaly from multiple streaming data sources at different granularity levels can be detected in near real-time. In this paper, we detail the implementation and deployment of the framework in Kubernetes clusters and report its performances when tested on electronic health record (EHR) data of Veterans Affairs.

Park, Byung↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗

Autonomous System Subversion Tactics: Prototypes and Recommended Countermeasures

One of the fielding requirements for Advanced and Small Modular Reactors (AR/SMR) is the ability to support remote and autonomous operations. Autonomous Control Systems (ACS) are found on platforms such as Autonomous Space Vehicles, Cruise Missiles, and advanced driver-assistance systems. Each of these ACS implementations depends upon a set of decision support subsystems responsible for supporting Autonomous Mission Managers (names vary based upon field and author preferences). These Autonomous Mission Managers receive inputs from system sensors (e.g., LIDAR collection from an automobile travelling down a street; transients from a nuclear reactor), and perform a set of classifications (e.g., Red Traffic Light; Small Pedestrian at 10m; Load Rejection; Single Coolant Pump Trip), and then use these classifications in combination with recommendation algorithms to achieve platform goals (e.g., Stop the Vehicle at the Traffic Light, Avoid the Small Pedestrian; Trip the Reactor to prevent a Safety Event). The design, implementation, and fielding of an ACS capability will alter the cyber-attack surface such that existing risk management plans will need to be updated to include how to protect and defend against data-science and decision-support-system attack classes. These attack classes would include protection of the design and training environments where algorithm selection and testing and training data would be obvious attack vectors. These attack classes would also require an informed set of detection and response procedures to identify anomalous behaviors and document best practices for anomaly assessment and vulnerability mitigation and remediation. Last year we published a Cyber Threat Assessment Methodology for Autonomous and Remote Operations for AR/SMRs along with a companion publication on Cyber Attack and Defense Use Cases. The focus of the methodology was on describing and enumerating ACS processes, components, and functions such that security engineers could: evaluate subversion options against the target; identify threat actor attributes and capabilities derived from each subversion option; and identify security controls and response countermeasures. The Use Cases document offered detailed methodology examples including an assessment of a Military Base SMR, an Autonomous System Decision Loop, and implementation of AR/SMR Machine Learning algorithms. Our proposal at the end of last year was to focus on implementation of subversion prototypes related to the last Use Case area: AR/SMR Machine Learning (ML) Algorithms. We included six attack scenarios in our Use Cases paper: a Poisoning Attack against ML functions implemented using an FPGA; a Trojaning Attack against ML classifiers exploiting the excitability of Nuclear Engineers; a Backdooring Attack against ML Training environments to ensure persistence of an attack vector; a False Positive Evasion Attack against multi-factor Access Control Systems using clever inputs; an Inference Attack against ML models by an Insider with access to the Operational environment; and an Adversarial Reprogramming Attack against a Material Access Control Video Surveillance System. At the beginning of this year these six attack scenarios were provided to our research teams at Georgia Tech and Idaho State University and each team successfully implemented a subversion attack against a ML implementation to include transient misclassifications. While this is a notable outcome from this type of research, this paper offers the reader insight into not only how to structure and execute these types of attacks, but into the thought process behind how the researcher investigated the problem space, performed initial algorithm implementation, and the trial-and-error behind arriving at the successful subversion prototypes. We include in this paper a set of associated Scenarios on how these subversion prototypes could be implemented and an initial set of guidance for AR/SMR architects, Nuclear Regulators, and Cyber Defenders to implement awareness and defense capabilities into their current operational portfolios.

42 ENGINEERING↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

M3AS-25IN1002073: Analysis of data from irradiation testing of printed strain gauges in prototypic nuclear environments

Advancement in additively manufactured strain gauges help address critical technology gaps to accurately monitor real-time materials behavior in reactor experiments. This is critical as it provides data to inform predictive models and simulations that enhance the development of reactors and fuel cycle systems. In this report, additively manufactured strain gauges are exposed to a neutron irradiation environment at the Ohio State University Research Reactor. This report goes over a 2-week campaign for neutron irradiating printed resistive strain gauges and capacitive strain gauges. These results complement the prior separate effects (i.e., mechanical strain, temperature, etc.) testing that were performed on these additive manufactured sensors and presented in prior milestone reports. These results also help progress our understanding of their usage in harsh environment applications. The outcome of developing advanced sensing and instrumentation capabilities plays an important role in increasing the safety, reliability, and energy efficiency of both next-generation and existing nuclear reactors.

36 - MATERIALS SCIENCE↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002↗

A compact mechanical power take-off for wave energy converters: Design, analysis, and test verification

Power Take-off (PTO) is one of the most critical components in the ocean wave conversion. This paper introduces an innovative compact mechanical PTO using a ball screw mechanism and a Mechanical Motion Rectifier (MMR) to improve the energy conversion performance. The proposed MMR PTO converts bidirectional oscillatory motion of the ocean waves into unidirectional rotation. The detailed design and working principle of the MMR PTO are explicitly explained. Dynamic analysis is presented for the three most important factors that influence the performance, including the equivalent mass, the equivalent damping, and the excitation frequency. The analytical relationship between these factors and the disengaged freewheeling motion caused by the MMR mechanism is derived, and the analytical solution is verified through dry lab testing. Experimental results in bench tests show that compared with the traditional linear PTO which use the ball screw to drive the generator directly, the MMR PTO is more efficient because of the unique freewheeling motion, achieving a maximum 81.2% energy transfer efficiency. After integrating the prototype PTO with a single-body point absorber type of wave energy converter, testing in a water tank yields total PTO efficiency up to 62.4%, showing a very promising potential for real applications.

16 TIDAL AND WAVE POWER↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

OPEN2018 (continuation of GENSETS effort)

This project has demonstrated the key components and engineering principles to support a residential scale (1 to 2 kWe) recuperated Brayton cycle generator based upon a screw compressor and screw expander. This technical work is a continuation of the previously awarded ‘GENSETS’ program. The product goal has been to achieve a 40% fuel-to-electric LHV efficiency, an 80% overall CHP efficiency, emissions qualified to the California Air Resources Board standards, and at noise levels of 55 dB or less at 1 meter. Further, the product must operate with 8,000 hour service intervals and achieve a mean-time to overhaul of 90,000 hours. Lastly, and possibly most importantly, the product must meet demanding cost targets, exhibiting a factory cost well below $1,500/kWe. After extensive aerodynamic studies under the ‘GENSETS’ program, Brayton concluded that miniature turbomachinery could not achieve an efficiency consistent with the product’s system performance goal. Given compressor and turbine efficiency targets in the range of 78 to 81%, Brayton turned to the rotary screw machines. While the justification for a screw compressor over a conventional centrifugal compressor is well supported by industry experience, the high temperature expander represented the core technology advancement. To meet the extremely high efficiency goals, an all-ceramic rotary screw expander hot section was developed and has now been tested in the laboratory. This first-of-its-kind ceramic screw expander prototype was able to demonstrate aerodynamic efficiency in line with predictions. The test article was successfully run to full stress conditions so has also validated the mechanical design of such a unit. This has opened new avenues for the commercialization of high efficiency, small scale power generation. Interest in the technology has sparked several requests for alternate uses, an invitation to present at a screw machine conference, and continued interest from parties looking to develop a product in the spirit of the original ‘GENSETS’ goals.

42 ENGINEERING↗

An innovative SR-WEC for a market-disruptive LCOE

The objective of DE-EE0008630: An innovative SR-WEC for a market-disruptive LCOE was to develop and test a scaled prototype of the Surface-Riding Wave Energy Converter that can result in a market-disruptive Levelized Cost of Energy by a combination of an extended operating window, substantially lowered cost and amplified average power output by simple optimum control. Initially conceptualized as a floating linear electrical generator (LEG), the SR-WEC evolved into an intermediate-scale version where multiple LEGs were mounted on a floating cylindrical body, driven by the need to enhance scalability and improve power performance.

16 TIDAL AND WAVE POWER↗

Lessons Learned: Summary of Insights From the HERO WEC and Waves to Water Deployments Between 2022 and 2024

In 2020, a team from the National Renewable Energy Laboratory (NREL) partnered with the East Carolina University Coastal Studies Institute to develop a small, modular, wave-powered point absorber desalination prototype. That prototype, known as the hydraulic and electric reverse osmosis wave energy converter (HERO WEC), was intended to de-risk the installation activities planned for the Waves to Water Prize sponsored by the Water Power Technologies Office. The NREL team was given approximately 18 months to design, build, bench test, and deploy the HERO WEC prototype. Since the initial HERO WEC development, it has been used for two in-lab test programs and three ocean deployments. The first in-lab test program focused on ensuring that the overall operation of the device occurred as expected and on validating the operation of safety systems such as pressure relief valves or electrical breakers for load mitigation. The second in-lab test program was the first time the NREL team leveraged NREL’s large-amplitude motion platform to characterize the performance of the HERO WEC. Of the three in-water deployments, the first deployment was effectively an installation and recovery practice with no meaningful wave activity during the time that it was installed. The second deployment was a 2-week effort that enabled both the electric and hydraulic configurations of the device to be in the water for approximately 5 days each. This deployment was also the first time that the team had the opportunity to perform a drivetrain swap on the Coastal Studies Institute research vessel. The third deployment had to be split into two separate installations due to minor damage incurred from the WEC spinning during the initial installation. This report summarizes the deployments, the challenges encountered with each deployment, and the lessons learned for future work.

16 TIDAL AND WAVE POWER↗

Do Flashing and Sealant Materials Need to be Exposed to Extreme Cycling?

In the U.S., over 50% of homes were built before 1980, when minimal building codes existed. The aging of building envelopes can significantly contribute to the air leakage, moisture intrusion, and durability of buildings leading to higher energy demands. Although the durability of building materials and envelope systems has been studied extensively, the durability of specific components like window-wall flashing and sealants remains underexplored. Current standards such as ASTM, NIST, and AAMA primarily focus on durability testing considering the high temperatures only and require sealant testing on anodized aluminum panels, leaving questions about performance in cold or fluctuating temperatures unanswered. Current ASTM and AAMA standards provide guidelines for durability testing but predominantly focus on exposure to higher temperature conditions. It remains unclear how exposure to cold temperatures, or cycles of both hot and cold conditions, affect the durability of these materials. Furthermore, AAMA standards mandate that flashing materials be tested on anodized aluminum panels, which may not reflect real-world applications. Therefore, this initial study aims to explore this concern through testing by constructing two window-wall interface prototypes and applying five different flashing and sealant materials to their joints. These samples were subjected to extreme temperatures, ranging from −34 ℃ (−30 °F) to 50 ℃ (122 °F), over a 28-day period (fourteen cycles of 24 hours), with daily visual inspections to document any signs of deterioration such as wrinkling, distortion, or warping. The study has two main objectives: (1) to determine whether flashing and sealant materials lose their durability and strength when exposed to varying climate conditions, specifically cold climates, and (2) to assess whether the interaction of these materials with different substrates (e.g., lumber, PVC, insulation) affects their durability and strength under varying climate conditions. The findings demonstrate how aging impacts the durability of window-wall systems interfaces, justifying future research that potentially could lead to the development of new testing protocols if significant defects are identified.