Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

System-Level Design Studies for Large Rotors

We examine the effect of rotor design choices on the power capture and structural loading of each major wind turbine component. A steady-state, harmonic model derived from simulations using the NREL aeroelastic code FAST is developed to reduce computational expense while evaluating design trade-offs for rotors with radii greater than 100 m. Design studies are performed, which focus on blade aerodynamic and structural parameters as well as different hub configurations and nacelle placements atop the tower. The effects of tower design and closed-loop control are also analyzed. Design loads are calculated according to the IEC design standards and used to calibrate the harmonic model and quantify uncertainty. Our design studies highlight both industry trends and innovative designs: we progress from a conventional, upwind, 3-bladed rotor, to a rotor with longer, more slender blades that is downwind and 2-bladed. For a 13 MW design, we show that increasing the blade length by 25 m while decreasing the induction factor of the rotor increases annual energy capture by 11% while constraining peak blade loads. A downwind, 2-bladed rotor design is analyzed, with a focus on its ability to reduce peak blade loads by 10% per 5 deg. of cone angle, and also reduce total blade mass. However, when compared to conventional, 3-bladed, upwind designs, the peak main bearing load of the up-scaled, downwind, 2-bladed rotor is increased by 280%. Optimized teeter configurations and individual pitch control can reduce non-rotating damage equivalent loads by 45% and 22%, respectively, compared with fixed-hub designs.

17 WIND ENERGY↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

System-level design studies for large rotors

Abstract. We examine the effect of rotor design choices on the power capture and structural loading of each major wind turbine component. A harmonic model for structural loading is derived from simulations using the National Renewable Energy Laboratory (NREL) aeroelastic code FAST to reduce computational expense while evaluating design trade-offs for rotors with radii greater than 100 m. Design studies are performed, which focus on blade aerodynamic and structural parameters as well as different hub configurations and nacelle placements atop the tower. The effects of tower design and closed-loop control are also analyzed. Design loads are calculated according to the IEC design standards and used to create a mapping from the harmonic model of the loads and quantify the uncertainty of the transformation. Our design studies highlight both industry trends and innovative designs: we progress from a conventional, upwind, three-bladed rotor to a rotor with longer, more slender blades that is downwind and two-bladed. For a 13 MW design, we show that increasing the blade length by 25 m, while decreasing the induction factor of the rotor, increases annual energy capture by 11 % while constraining peak blade loads. A downwind, two-bladed rotor design is analyzed, with a focus on its ability to reduce peak blade loads by 10 % per 5° of cone angle and also reduce total blade mass. However, when compared to conventional, three-bladed, upwind designs, the peak main-bearing load of the upscaled, downwind, two-bladed rotor is increased by 280 %. Optimized teeter configurations and individual pitch control can reduce non-rotating damage equivalent loads by 45 % and 22 %, respectively, compared with fixed-hub designs.

17 WIND ENERGY↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Divertor configuration and heat load studies for the ARIES-CS fusion power plant

The critical issue of divertor configuration for heat and particle flux control in a conceptual ARIES compact stellarator (CS) reactor is addressed. The goal is to determine a divertor location and geometry with a peak heat load of not more than 10 MW/m(2) for a CS equilibrium based on the configuration to be used in the NCSX experiment, optimized for high beta (6.4%) and designed for low alpha-particle power loss fraction (<= 5%). The surface heat flux on the target has three components: thermal particles, lost energetic alphas, and radiation from the core and the scrape-off layer. The first two components are dominant and their magnitudes can be comparable. To maintain a tritium-breeding ratio of 1.1, the total target area should not exceed 15% of the boundary plasma surface area. The divertor concept consists of two pairs of target plates per field period, one pair each at the top and bottom of the plasma. The heat flux profile is assessed by assuming that the parallel transport can be represented by field line mapping and that cross-field transport can be modeled with a prescribed field line diffusion scheme. In this manner, the poloidal and toroidal extents of the plates and their shape and distance to the plasma are designed to intercept all the heat flux and to minimize the peak thermal heat load. An approximate scheme, based on particle drift orbits in the core and field line tracing in the edge, is derived to estimate the alpha-particle heat load distribution over the plates and the first wall. The best plate configuration to date yields total peak heat loads (thermal + alpha) ranging from 5 to 18 MW/m(2). Further optimization of the target plates is required to reach the design goal, which will be addressed in a future study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel stochastic modeling method to simulate cooling loads in residential districts

District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3) a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions

As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and voltage/frequency ride-through, among others. This paper describes the results of a comparative experimental evaluation on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and its effect on abnormal grid condition response. The evaluation examined the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. Testing results indicated a wide variance in the performance of GSF enabled inverters to various test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive Home Energy Management Systems: The Impact of Their Proliferation on the Electric Grid

Approximately 100 million singlefamily homes in the United States account for 36% of the electricity load, and often they determine the peak system load, especially on hot summer days when residential air-conditioning use is high. Traditional building power profiles are changing. Currently, there is an increased use of energy-efficient building materials and designs, which decreases building loads. In addition, there is an increased adoption of rooftop solar photovoltaic (PV), which leads to bidirectional power flow and significant power ramps as PV output decreases in the late afternoon. Building power profiles are likely to change even more as residential energy storage products proliferate. Therefore, a better understanding of residential electricity demand is key to addressing the envisioned transition of the electric power system from its traditional structure to one that is transactive.

25 ENERGY STORAGE↗

Effect of axial impact on the static flexure of graphite/epoxy beams

Graphite-epoxy beams were subjected to an eccentric axial impact load in a drop tower test fixture in order to study their large displacement flexural behavior. The time history of the transient axial load exhibited a large magnitude occurring just after impact, which was many times greater than the static failure load. The damage caused by this peak dynamic load was measured by the reduction in energy absorption of the impacted beam relative to a virgin beam in static tests. For the thirty-ply specimens, the amount of damage increased with increasing axial stiffness.

Sensmeier, M. D.↗

Transient Three-Dimensional Side Load Analysis of a Film Cooled Nozzle

Transient three-dimensional numerical investigations on the side load physics for an engine encompassing a film cooled nozzle extension and a regeneratively cooled thrust chamber, were performed. The objectives of this study are to identify the three-dimensional side load physics and to compute the associated aerodynamic side load using an anchored computational methodology. The computational methodology is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, and a transient inlet history based on an engine system simulation. Ultimately, the computational results will be provided to the nozzle designers for estimating of effect of the peak side load on the nozzle structure. Computations simulating engine startup at ambient pressures corresponding to sea level and three high altitudes were performed. In addition, computations for both engine startup and shutdown transients were also performed for a stub nozzle, operating at sea level. For engine with the full nozzle extension, computational result shows starting up at sea level, the peak side load occurs when the lambda shock steps into the turbine exhaust flow, while the side load caused by the transition from free-shock separation to restricted-shock separation comes at second; and the side loads decreasing rapidly and progressively as the ambient pressure decreases. For the stub nozzle operating at sea level, the computed side loads during both startup and shutdown becomes very small due to the much reduced flow area.

Wang, Ten-See↗

Modeling of divertor geometry effects in China fusion engineering testing reactor by SOLPS/B2-Eirene

The China Fusion Engineering Testing Reactor (CFETR) is currently under design. The SOLPS/B2-Eirene code package is utilized for the design and optimization of the divertor geometry for CFETR. Detailed modeling is carried out for an ITER-like divertor configuration and one with relatively open inner divertor structure, to assess, in particular, peak power loading on the divertor target, which is a key issue for the operation of a next-step fusion machine, such as ITER and CFETR. As expected, the divertor peak heat flux greatly exceeds the maximum steady-state heat load of 10 MW/m{sup 2}, which is a limit dictated by engineering, for both divertor configurations with a wide range of edge plasma conditions. Ar puffing is effective at reducing divertor peak heat fluxes below 10 MW/m{sup 2} even at relatively low densities for both cases, favoring the divertor configuration with more open inner divertor structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active control of divertor asymmetry on EAST by localized D{sub 2} and Ar puffing

The divertor asymmetry in particle and power fluxes has been investigated on the EAST superconducting tokamak [S. Wu and EAST Team, Fusion Eng. Des. 82, 463 (2007)] for both single null (SN) and double null (DN) divertor configurations. D{sub 2} and Ar puffing at various divertor locations has also been explored as an active means to reduce peak target heat load and control divertor asymmetry. For SN, peak heat load on the outer divertor target is 2-3 times that on the inner divertor target under typical ohmic plasma conditions. DN operation leads to a stronger in-out asymmetry favoring the outer divertor. D{sub 2} and Ar puffing promotes partial detachment near the strike points, greatly reducing peak target heat load (over 50%), while the far-SOL divertor plasma remains attached. What is remarkable is that the particle flux is even increased away from the strike points when the Bx{nabla}B drift is directed toward the divertor target, thus facilitating particle removal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Joint Optimization Scheme for the Planning and Operations of Shared Autonomous Electric Vehicle Fleets Serving Mobility on Demand

As the transportation sector undergoes three major transformations—electrification, shared/on-demand mobility, and automation—there are new challenges to analyzing the impacts of these trends on both the transportation system and the power sector. Most models that analyze the requirements of fleets of shared autonomous electric vehicles (SAEVs) operate at the scale of an urban region, or smaller. A quadratically constrained, quadratic programming problem is formulated, designed to model the requirements of SAEVs at a national scale. The size of the SAEV fleet, the necessary charging infrastructure, the fleet charging schedule, and the dispatch required to serve demand for trips in a region are treated as decision variables. By minimizing both the amortized cost of the fleet and chargers as well as the operational costs of charging, it is possible to explore the coupled interactions between system design and operation. To apply the model at a national scale, key complications about fleet operations are simplified; but a detailed agent-based regional simulation model to parameterize those simplifications is leveraged. Preliminary results are presented, finding that all mobility in the United States (U.S.) currently served by 276 million personally owned vehicles could be served by 12.5 million SAEVs at a cost of $\$ 0.27$/vehicle-mile or $ 0.18/passenger-mile. In conclusion, the energy requirements for this fleet would be 1142 GWh/day (8.5% of 2017 U.S. electricity demand) and the peak charging load 76.7 GW (11% of U.S. power peak). Several model sensitivities are explored, and it is found that sharing is a key factor in the analysis.

33 ADVANCED PROPULSION SYSTEMS↗

A comparison between theoretical prediction and experimental measurement of the dynamic behavior of spur gears

A comparison was made between computer model predictions of gear dynamics behavior and experimental results. The experimental data were derived from the NASA gear noise rig, which was used to record dynamic tooth loads and vibration. The experimental results were compared with predictions from the DSTO Aeronautical Research Laboratory's gear dynamics code for a matrix of 28 load speed points. At high torque the peak dynamic load predictions agree with the experimental results with an average error of 5 percent in the speed range 800 to 6000 rpm. Tooth separation (or bounce), which was observed in the experimental data for light torque, high speed conditions, was simulated by the computer model. The model was also successful in simulating the degree of load sharing between gear teeth in the multiple tooth contact region.

Rebbechi, Brian↗

Earth return aerocapture for manned Mars missions

Lift to drag ratio (L/D) requirements and stagnation point heating have been examined for a variety of probable entry conditions and vehicle configurations. It is found that vehicles with an L/D of 0.5 or more provide a corridor width of at least 0.7 degrees while keeping the peak deceleration load below 5 g for approach velocities up to 14.5 km/s. It is shown that stagnation point peak heating rates and integrated heat load critically depend on both entry velocity and ballistic coefficient. For the most severe cases under consideration, peak heating and integrated heat load are five times greater than those encountered by Apollo but within the range of experience for unmanned vehicles.

Tauber, M. E.↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Impurity-induced divertor plasma oscillations

Two different oscillatory plasma regimes induced by seeding the plasma with high- and low-Z impurities are found for ITER-like divertor plasmas, using computer modeling with the DUSTT/UEDGE and SOLPS4.3 plasma-impurity transport codes. The oscillations are characterized by significant variations of the impurity-radiated power and of the peak heat load on the divertor targets. Qualitative analysis of the divertor plasma oscillations reveals different mechanisms driving the oscillations in the cases of high- and low-Z impurity seeding. The oscillations caused by the high-Z impurities are excited near the X-point by an impurity-related instability of the radiation-condensation type, accompanied by parallel impurity ion transport affected by the thermal and plasma friction forces. The driving mechanism of the oscillations induced by the low-Z impurities is related to the cross-field transport of the impurity atoms, causing alteration between the high and low plasma temperature regimes in the plasma recycling region near the divertor targets. The implications of the impurity-induced plasma oscillations for divertor operation in the next generation tokamaks are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗