Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Active-Interrogation Measurements of Induced-Fission Neutrons from Low-Enriched Uranium

Protection and control of nuclear fuels is paramount for nuclear security and safeguards; therefore, it is important to develop fast and robust controlling mechanisms to ensure the safety of nuclear fuels. Through both passive- and active-interrogation methods we can use fast-neutron detection to perform real-time measurements of fission neutrons for process monitoring. Active interrogation allows us to use different ranges of incident neutron energy to probe for different isotopes of uranium. With fast-neutron detectors, such as organic liquid scintillation detectors, we can detect the induced-fission neutrons and photons and work towards quantifying a sample’s mass and enrichment. Using MCNPX-PoliMi, a system was designed to measure induced-fission neutrons from U-235 and U-238. Measurements were then performed in the summer of 2010 at the Joint Research Centre in Ispra, Italy. Fissions were induced with an associated particle D-T generator and an isotopic Am-Li source. The fission neutrons, as well as neutrons from (n, 2n) and (n, 3n) reactions, were measured with five 5” by 5” EJ-309 organic liquid scintillators. The D-T neutron generator was available as part of a measurement campaign in place by Padova University. The measurement and data-acquisition systems were developed at the University of Michigan utilizing a CAEN V1720 digitizer and pulse-shape discrimination algorithms to differentiate neutron and photon detections. Low-enriched uranium samples of varying mass and enrichment were interrogated. Acquired time-of-flight curves and cross-correlation curves are currently analyzed to draw relationships between detected neutrons and sample mass and enrichment. In the full paper, the promise of active-interrogation measurements and fast-neutron detection will be assessed through the example of this proof-of-concept measurement campaign. Additionally, MCNPX-PoliMi simulation results will be compared to the measured data to validate the MCNPX-PoliMi code when used for active-interrogation simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.3 keV NR via the asymmetric emission of γ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Additionally, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.

detector calibration↗

Measurment and energy correction due to charge carrier lifetimes in large HPGe spectrometers

This work addresses the energy spectrum correction due to increased charge carrier collection times in larger HPGe spectrometers. The energy of the radiation interaction is expected to be proportional to the total collected charge. This is increasingly not true with larger HPGe spectrometers. Some charge is lost as the total charge travels from the interaction location to the collection electrode. This path dependent loss of charge results in decreased energy resolution. In HPGe spectrometers, this process is characterized by the charge carrier lifetime constant and is given as an exponential function of the charge carrier collection time divided by this constant. Thus large detectors can experience exponential decrease in energy resolution as charge carrier collection time increases. We study the effect of charge carrier lifetime on energy resolution for a large diameter p-type coaxial and p-type point contact HPGe spectrometers using pulse shape analysis. We present a method to measure the charge carrier lifetime for a given HPGe spectrometer.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Coincident Capture through Post-processing PTRAC [Slides]

This presentation discusses the new PTRAC capabilities and workflows. The PTRAC capability in MCNP6.3 has seen a massive overhaul since MCNP6.2. The new HDF5 file format allows for both MPI- and thread-based parallelism. MCNPTools has been updated to handle the new HDF5 PTRAC format and is now open sourced on GitHub. Built-in capabilities, such as the pulse-height tally coincident capture special treatment, can largely be replicated through separate postprocessing scripts that leverage both PTRAC and MCNPTools. This allows for greater flexibility in user-specified and controlled detector response functionality, ultimately using the MCNP code for what it is best at (i.e., particle transport).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phonon Sensor Dynamics for Cryogenic Dark Matter Search Experiment

Understanding the quasiparticle diffusion process inside sputtered aluminum (Al thin films (∼ 0.1-1 μm is critical for the Cryogenic Dark Matter Search (CDMS experiment to further optimize its detectors to directly search for dark matter. An initial study with Al films was undertaken by our group ∼ 20 years ago, but some important questions were not answered at the time. This thesis can be considered a continuation of that critical study. The CDMS experiment utilizes high purity silicon and germanium crystals to simultaneously measure ionization and phonons created by particle interactions. In addition to describing some of the rich physics involved in simultaneously detecting ionization and phonons with a CDMS detector, this thesis focuses on the detailed physics of the phonon sensors themselves, which are patterned onto CDMS detector surfaces. CDMS detectors use thin sputtered Al films to collect phonon energy when it propagates to the surfaces of the detector crystals. The phonon energy breaks Cooper pairs and creates quasiparticles (qps). These qps diffuse until they get trapped in an proximitized “overlap” region where lower-Tc tungsten films connect to the Al film. These tungsten films are the transition edge sensors (W-TESs CDMS uses to readout phonon signals. We performed a wide range of experiments using several sets of test devices designed and fabricated specifically for this work. The devices were used mostly to study quasiparticle (qp transport in Al films and qp transmission through Al/W interfaces. The results of this work are being used to optimize the design of detectors for SuperCDMS SNOLAB. This thesis is intended for CDMS collaborators who are interested in knowing more about the detailed fundamentals of how our phonon sensors work so they can take full advantage of their benefits. However, this work can also be read by general readers who are interested in particle detection using TES technology. This thesis contains eight chapters. The first chapter gives basic background information about dark matter and searches for it. We then describe the basic CDMS detector technology in Chapter two. Chapter three focuses on superconductivity and explains some of the solid state physic most relevant to our Al and W film studies. We then turn our attention to the fabrication processes used to make test devices, and describe some of the studies done to characterize our W and Al film properties. Chapter five explains the experimental setup including how a 3He/4He dilution refrigerator works, and how our electronics were configured. We then get to chapter six where we present key experimental results. Chapter seven covers the TES model we used for our test devices to simulate the data pulse shapes and reconstruct the pulse energies. We also describe the diffusion models used to fit our data. Finally, we end with a short summary of our findings and provide a few suggestions for future studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an active detector for the characterization of the late-time radiation environment from a reactor pulse

Document available in abstract form only, full text of document follows: This paper discusses the use of a commercially available {sup 235}U fission chamber, with a matching compensating ion chamber, originally sold as a single-ended detector with the signal conducted over the shield of a coaxial cable. The authors designed an aluminum housing that isolates the two detectors and converts the signals to full differential mode as a noise-reduction technique. The signals are processed using the switched resistor technique to extend the signal range to longer times from the peak of the pulse [Luker, S. M., Griffin, P. J., King, D. B., and Suo-Anttila, A. J., 'Improved Diagnostics for Analysis of a Reactor Pulse Radiation Environment,' 13. International Symposium on Reactor Dosimetry, Akersloot, Netherlands, May 25, 2008, pp. 4-6.]. The newly configured fission chamber assembly has been used at the annular core research reactor at Sandia National Laboratories to provide a high-fidelity characterization of the neutron time profile from a pulsed operation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron-gamma discrimination on neutron emission profile measurement on JT-60U

A digital signal processing (DSP) system is applied to stilbene scintillation detectors of the multichannel neutron emission profile monitor in JT-60U. Automatic analysis of the neutron-{gamma} pulse shape discrimination is a key issue to diminish the processing time in the DSP system, and it has been applied using the two-dimensional (2D) map. Linear discriminant function is used to determine the dividing line between neutron events and {gamma}-ray events on a 2D map. In order to verify the validity of the dividing line determination, the pulse shape discrimination quality is evaluated. As a result, the {gamma}-ray contamination in most of the beam heating phase was negligible compared with the statistical error with 10 ms time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A front-end readout Detector Board for the OpenPET electronics system

Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.

47 OTHER INSTRUMENTATION↗

Radiation-Induced Plutonium Redox Chemistry

Plutonium plays a key role in global actinide research and nuclear fuel cycle technologies, and yet, our fundamental understanding of its inherent radiation-induced chemical behavior is limited. These radiation-induced processes cannot simply be switched off, as they are as fundamentally inherent to plutonium as the impact of relativistic effects on its f-electrons. In less chemically complex actinide systems, such as aqueous solutions of neptunium and americium, , radiolysis products play a significant role in the redox cycling of their oxidation states. However, plutonium's multiple, coexisting, and chemically active oxidation states, which comprise of bare ions and dioxo cations, provide additional redox pathways that complicate radiation-induced processes. Oxidation state control is critical for the manipulation of plutonium, especially in used nuclear fuel reprocessing technologies, where oxidation specific states are successfully extracted, and others rejected. Consequently, mechanistically understanding the behavior of plutonium’s multiple oxidation states in the presence of intense ionizing radiation fields is essential for predicting the behavior of this element under multiple conditions that support the development and innovation of nuclear fuel cycle technologies. Here, we present recent advances in our understanding of plutonium radiation chemistry, including the first-ever multiscale model for predicting gamma radiation-induced plutonium redox chemistry, and new chemical kinetics for the reaction of plutonium and its complexes of tributyl phosphate (TBP), N,N-di-(2-ethylhexyl)butyramide (DEHBA), and N,N-di-(2-ethylhexyl)isobutyramide (DEHiBA) with transients radiolysis products, a measured using electron pulse radiolysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pulse repetition rate in a self-contained strontium ion laser

The frequency and energy parameters of self-contained strontium ion laser ({lambda} = 1.033 and 1.091 {mu}m) are studied upon excitation by an additional pulse before each excitation pulse. The kinetics of processes in the active medium of this laser is numerically simulated. It is shown that the pulse repetition rate of the self-contained strontium laser can achieve {approx}1 MHz. It is found that the laser pulse energy in the first pulse and the average output power and efficiency increase in a certain range of time delays between the additional and excitation pulses, which is caused by the significant prepulse concentration of strontium ions which had no time to recombine. The outlook for the application of pulse trains to excite self-contained IR transitions in strontium ions is shown. (lasers)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modelling of the laser amplification process with allowance for the effect of the temperature distribution in an Yb : YAG gain element on the thermophysical and lasing characteristics of the medium

A time-dependent three-dimensional model for the laser amplification process has been constructed with allowance for the effect of the temperature distribution on the thermophysical and lasing characteristics of gain media. We have performed numerical modelling of the laser amplification process in the gain elements of a two-stage subjoule-level cryogenic laser amplifier operating at a pulse repetition rate of up to 1 kHz. It has been shown that taking into account the temperature distribution is of critical importance in calculation of cryogenically cooled laser amplifiers pumped with high-power diodes. We have found optimal diode pump parameters at which the maximum achievable pulse energy at the amplifier output can reach 300 and 570 mJ at pulse repetition rates of 1000 and 500 Hz, respectively. (extreme light fields and their interaction with matter)

42 ENGINEERING↗

Two-photon-induced x-ray emission in neon atoms

We investigated the resonant x-ray emission from a neon atom induced by the two-photon population of a double-core-hole excited state. Two qualitatively different schemes of this process are studied: The first one involves an off-resonant intermediate single-core-hole state; the second scheme passes through a resonant core-ionized intermediate state. The numerical simulations of the resonant x-ray emission performed for different peak intensities and pulse durations show significant population of the double-core-hole final states. Therefore, rather strong two-photon absorption-induced x-ray emission is predicted for both studied schemes. Thus, high counting rates in experimental measurements are expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing energy transfer events in the light harvesting complex 2 (LH2) of Rhodobacter sphaeroides with two-dimensional spectroscopy

Excitation energy transfer events in the photosynthetic light harvesting complex 2 (LH2) of Rhodobacter sphaeroides are investigated with polarization controlled two-dimensional electronic spectroscopy. A spectrally broadened pulse allows simultaneous measurement of the energy transfer within and between the two absorption bands at 800 nm and 850 nm. The phased all-parallel polarization two-dimensional spectra resolve the initial events of energy transfer by separating the intra-band and inter-band relaxation processes across the two-dimensional map. The internal dynamics of the 800 nm region of the spectra are resolved as a cross peak that grows in on an ultrafast time scale, reflecting energy transfer between higher lying excitations of the B850 chromophores into the B800 states. We utilize a polarization sequence designed to highlight the initial excited state dynamics which uncovers an ultrafast transfer component between the two bands that was not observed in the all-parallel polarization data. We attribute the ultrafast transfer component to energy transfer from higher energy exciton states to lower energy states of the strongly coupled B850 chromophores. Connecting the spectroscopic signature to the molecular structure, we reveal multiple relaxation pathways including a cyclic transfer of energy between the two rings of the complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a bi-solvent liquid scintillator with slow light emission

One of the most promising approaches for the next generation of neutrino experiments is the realization of large hybrid Cherenkov/scintillation detectors made possible by recent innovations in photodetection technology and liquid scintillator chemistry. The development of a potentially suitable future detector liquid with particularly slow light emission is discussed in the present publication. This cocktail is compared with respect to its fundamental characteristics (scintillation efficiency, transparency, and time profile of light emission) with liquid scintillators currently used in large-scale neutrino detectors. In addition, the optimization of the admixture of wavelength shifters for a scintillator with particularly high light emission is presented. Furthermore, the pulse-shape discrimination capabilities of the novel medium was studied using a pulsed particle accelerator driven neutron source. Beyond that, purification methods based on column chromatography and fractional vacuum distillation for the co-solvent DIN (Diisopropylnaphthalene) are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVIDENCE FOR RADIOGENIC SULFUR-32 IN TYPE AB PRESOLAR SILICON CARBIDE GRAINS?

We report C, Si, and S isotope measurements on 34 presolar silicon carbide grains of Type AB, characterized by {sup 12}C/{sup 13}C < 10. Nitrogen, Mg-Al-, and Ca-Ti-isotopic compositions were measured on a subset of these grains. Three grains show large {sup 32}S excesses, a signature that has been previously observed for grains from supernovae (SNe). Enrichments in {sup 32}S may be due to contributions from the Si/S zone and the result of S molecule chemistry in still unmixed SN ejecta or due to incorporation of radioactive {sup 32}Si from C-rich explosive He shell ejecta. However, a SN origin remains unlikely for the three AB grains considered here, because of missing evidence for {sup 44}Ti, relatively low {sup 26}Al/{sup 27}Al ratios (a few times 10{sup –3}), and radiogenic {sup 32}S along with low {sup 12}C/{sup 13}C ratios. Instead, we show that born-again asymptotic giant branch (AGB) stars that have undergone a very-late thermal pulse (VLTP), known to have low {sup 12}C/{sup 13}C ratios and enhanced abundances of the light s-process elements, can produce {sup 32}Si, which makes such stars attractive sources for AB grains with {sup 32}S excesses. This lends support to the proposal that at least some AB grains originate from born-again AGB stars, although uncertainties in the born-again AGB star models and possible variations of initial S-isotopic compositions in the parent stars of AB grains make it difficult to draw a definitive conclusion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of highly ionizing particles: Nonlinear near-surface phenomena in silicon radiation detectors

As far as the detection system is concerned, experimens on synthesis and study of the properties of superheavy nuclei is one of the most difficult tasks. In fact, these experiments can be considered extreme in many senses: —extremely low (fractions of a picobarn-picobarns) formation cross sections of the products under investigation —extremely high heavy ion beam intensities for example, ∼1.1–1.5 pμA{sup 1} {sup 48}Ca —high radioactivity of actinide targets, which are used in the experiments aimed at the synthesis of super-heavy nuclei —very long duration of the experiment (as long as a year) —extremely low yield of the products under investigation (sometimes less than 1 per month) —very high sensitivity of the detection system —radical suppression of the background products (method of “active correlations”). The two last points are the subject of the present paper, as well as the subject of two of my reviews published before. It is evident that without knowledge of the nature of the internal processes in semiconductor detectors it is virtually impossible to provide clear detection of ultra rare signals. In the present paper, the author reports on the investigation of near-surface phenomena in silicon radiation detectors, first of all bearing in mind the theoretical-methodological aspect of these phenomena. Non-equilibrium electron-hole recombination, pulse height defect formation, charge multiplication, and formation of “hot” electron system, are considered. With just these phenomena one can observe nonlinearity of energy-charge-amplitude conversion for heavy ion (recoil nucleus) registered by a silicon detector. Practical applications are also considered. One of them is a deeply modified method of “active correlations”. Projection of applying the method in the experiments with the modernized cyclotron (DC-280 FLNR project) is projected as well as possible applications in the heavy-ion-induced complete fusion nuclear reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Laser-Driven Pulsed Neutron Sources for Poolside Neutron-based Advanced NDE – A Pathway to LANSCE-like Characterization at INL

A variety of opportunities for characterization of fresh nuclear fuels using thermal (~25meV) and epithermal (~10eV) neutrons have been documented at Los Alamos National Laboratory. They include spatially resolved non-destructive characterization of features, isotopic enrichment, chemical heterogeneity and stoichiometry. The LANSCE spallation neutron source is well suited in neutron fluence and temporal characteristics for studies of fuels. However, recent advances in high power short pulse lasers suggest that compact neutron sources might, over the next decade, become viable at a price point that would permit their consideration for poolside characterization on site at irradiation facilities. In a laser-driven neutron source the laser is used to accelerate deuterium ions into a beryllium target where neutrons are produced. At this time, the technology is new and their total neutron production is approximately four orders of magnitude less than a facility like LANSCE. However, recent measurements on a sub-optimized system demonstrated >10 10 neutrons in sub-nanosecond pulses in predominantly forward direction. The compactness of the target system compared to a spallation target may allow exchanging the target during a measurement to e.g. characterize a highly radioactive sample with thermal, epithermal, and fast neutrons as well as hard X-rays, thus avoiding sample handling. At this time several groups are working on laser-driven neutron production and are advancing concepts for lasers, laser targets, and optimized neutron target/moderator systems. Advances in performance sufficient to enable poolside fuels characterization with LANSCE-like fluence on sample within a decade may be possible. This report describes the underlying physics and state-of-the-art of the laser-driven neutron production process from the perspective of the DOE/NE mission. It also discusses the development and understanding that will be necessary to provide customized capability for characterization of irradiated fuels. Potential operational advantages compared to a spallation neutron source include reduced shielding complexity, reduced energy requirements, and a production target free of fission products. Contributors to this report include experts in laser-driven neutron production (Roth, Fernandez), laser design (Haefner, Siders, Leemans), laser target design (Glenzer), spallation target/moderator design (Mocko), neutron instrumentation and characterization applications (Vogel, Bourke).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mode-dependent dispersion in Raman line shapes: Observation and implications from ultrafast Raman loss spectroscopy

Ultrafast Raman loss spectroscopy (URLS) enables one to obtain the vibrational structural information of molecular systems including fluorescent materials. URLS, a nonlinear process analog to stimulated Raman gain, involves a narrow bandwidth picosecond Raman pump pulse and a femtosecond broadband white light continuum. Under nonresonant condition, the Raman response appears as a negative (loss) signal, whereas, on resonance with the electronic transition the line shape changes from a negative to a positive through a dispersive form. The intensities observed and thus, the Franck-Condon activity (coordinate dependent), are sensitive to the wavelength of the white light corresponding to a particular Raman frequency with respect to the Raman pump pulse wavelength, i.e., there is a mode-dependent response in URLS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗