Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutral model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Texas A&M University Mobile Facility Measurements during TRACER (Field Campaign Report)

One of the main goals of the U.S Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) near Houston, Texas is to improve understanding of how meteorology and aerosols impact storm dynamical and microphysical processes in deep convection to better constrain and improve their model representation. The Houston area is strongly influenced by sea- and bay-breeze circulations that generate convergence and help to initiate and organize deep convection. To properly isolate and understand the roles of varied meteorological conditions and cloud condensation nuclei (CCN) and ice nucleation particles (INP) distributions in different air masses, co-located thermodynamic, kinematic, and aerosol vertical profile observations are needed. The focus of this campaign was to provide key measurements in air masses both in front of and behind sea/bay breeze fronts moving through the greater Houston area to sample the airmass heterogeneity. The overarching scientific goal of this campaign is to understand how the vertical distributions of both CCN and INP correspond to the inflow layer of deep convection in maritime, background continental, and polluted continental air masses, and how these variations influence deep convection. To fully sample the heterogeneity in both meteorological conditions and aerosols across the sea-breeze front (SBF), Texas A&M University (TAMU) deployed a InterMet 3050A 403 MHz mobile unit launching iMet-4 radiosondes and the new Rapid Onsite Atmospheric Measurement Van (ROAM-V) for aerosol sampling during the TRACER intensive operational period (IOP) from June to September 2022. The suite of instruments deployed on ROAM-V included a condensation particle counter (CPC; GRIMM Model 5.403 CPC), scanning mobility particle sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A differential mobility analyzer), cloud condensation nuclei counter (Droplet Measurement Technologies CCN counter), micropulse lidar (Droplet Measurement Technologies micropulse lidar [miniMPL]), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the Global Positioning System (GPS) on the phone application “My Altitude”. The DRUM data were collected as part of a closely related ARM field campaign and also supported by DOE Atmospheric System Research grant DE-SC0021047. The TAMU team sampled these airmass heterogeneities by strategically choosing deployment sites in a different airmass than the ARM fixed sites in La Porte and Guy, Texas. On days when the sea/bay breeze boundary was pushing inland, the TAMU team would usually sample the airmass on the maritime side of the SBF at a coastal site in Galveston, Texas in the early afternoon (1730-1900 UTC) and then move inland ahead of the SBF to sample the airmass on the continental side during late afternoon (2030-2230). Figure 1 shows the Galveston maritime site and the array of sites for the late afternoon continental measurements.

54 ENVIRONMENTAL SCIENCES↗

Deterministic Transport: An Introduction [Slides]

In this lecture, we cover deterministic particle transport. We focus on neutral particles (neutrons, gamma-rays, and thermal photons). Our goal is to predictively and accurately model how free particles interact with their environments and properties of systems involving those particles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Mini-Micropulse Lidar data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (mini-MPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. The mini-MPL deployed with ROAM-V is a 532 nm elastic and polarization lidar. The mini-MPL outputs normalized relative backscatter (NRB) derived from raw signal after after-pulse, overlap, and dead-time correction calibration. The depolarization ratio is calculated from the co-polarized and cross-polarized NRB (Flynna et al., 2007). The NRB and depolarization ratio data are resampled from the original data at 1-minute intervals. The vertical resolution of the mini-MPL data is 15 meters. The mini-MPL data can be used to determine the boundary layer, cloud top, and cloud bottom height and can be used to retrieve aerosol type and concentration profile. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu . Flynna, C. J., Mendozaa, A., Zhengb, Y., & Mathurb, S. (2007). Novel polarization-sensitive micropulse lidar measurement technique. Optics express, 15(6), 2785-2790.

54 ENVIRONMENTAL SCIENCES↗

Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber

Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Protein-based models offer mechanistic insight into complex nickel metalloenzymes

There are ten nickel enzymes found across biological systems, each with a distinct active site and reactivity that spans reductive, oxidative, and redox–neutral processes. We focus on the reductive enzymes, which catalyze reactions that are highly germane to the modern-day climate crisis: [NiFe] hydrogenase, carbon monoxide dehydrogenase, acetyl coenzyme A synthase, and methyl coenzyme M reductase. The current mechanistic understanding of each enzyme system is reviewed along with existing knowledge gaps, which are addressed through the development of protein-derived models, as described here. Finally, this opinion is intended to highlight the advantages of using robust protein scaffolds for modeling multiscale contributions to reactivity and inspire the development of novel artificial metalloenzymes for other small molecule transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a collisional radiative model for electron temperature determination in hydrogen plasma

A collisional-radiative (CR) model that extracts the electron temperature, T e , of hydrogen plasmas from Balmer-line-ratio measurements is examined for the plasma electron density, n e , and T e ranges of 10 10 –10 15 cm –3 and 5–500 eV, respectively. The CR code, developed and implemented in Python, has a forward component that computes the densities of excited states up to n = 15 as functions of T e , n e , and the molecular-to-atomic neutral ratio r(H 2 /H). The backward component provides ne and r(H 2 /H) as functions of the Balmer ratios to predict the T e . The model assumes Maxwellian electrons. Furthermore, the density profiles of the electrons and of the molecular and atomic hydrogen neutrals are shown to be of great importance, as is the accuracy of the line-ratio measurement method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of 𝜋 0 production in $\bar{v}_μ$ charged-current interactions in the NOvA near detector

We present a high-statistics measurement of muon antineutrino-induced charged-current neutral pion production on a hydrocarbon target using the NOvA near detector. The differential cross sections as functions of the momenta and angles of the outgoing pion and muon, the squared four-momentum transfer, and the invariant mass of the hadronic system at an average neutrino energy of 2 GeV are measured and compared with predictions from various neutrino interaction models. The results agree with the GENIE prediction but suggest that other models underestimate the cross section in the Δ⁡(1232) resonance region. These results represent the most precise measurement of antineutrino-induced neutral pion production to date.

neutrino detection↗

The plasma–sheath transition and Bohm criterion in a high recycling divertor

The high recycling regime of a divertor is characterized by high plasma particle fluxes and low temperature at the target, where a strong hydrogen recirculation loop exists. Atomic processes in the high recycling regime, such as ion–neutral friction and radiation, can affect the plasma momentum and energy transport in the sheath transition region. Here, in this work, the plasma–sheath transition near a high recycling wall is investigated. The Bohm speed, which constraints the ion exit flow speed, is evaluated from a transport model that accounts for the effect of the anisotropic transport and atomic collisions in the transition layer. A first principles kinetic code vector particle-in-cell with the atomic collision package is used to investigate a 1D self-consistent slab plasma with a high recycling boundary for the tungsten and carbon divertors. The results demonstrate the accuracy of the Bohm speed model in predicting the ion exit flow speed in the transition region, as well as the reduction of the Bohm speed due to the ion–neutral friction. The effect of different wall materials, tungsten, and carbon, on the Bohm speed and near-wall plasma profile is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First operation and validation of simulations for the divertor cryo-vacuum pump in Wendelstein 7-X

Ten cryo-vacuum pumps (CVPs) were installed in the subdivertor region of each island divertor in the stellarator Wendelstein 7-X (W7-X) and operated for the first time during the recently completed plasma campaign OP2.1. A pumping speed of 70 ± 1 $\frac{m^3}{s}$ was measured during dedicated tests with known hydrogen gas injection. Based on a conductance model, the estimated pumping speed ranges from 86-93 $\frac{m^3}{s}$ for different sticking coefficients between 0.6 and 0.8. After completion of the initial tests the CVPs were operated successfully throughout the campaign, with regeneration performed once a week. Neutral gas pressures in the subdivertor in the range of 10 −4 mbar are well within the molecular flow regime and limit the particle exhaust capabilities of the CVPs. Simulations of the neutral gas pressure in the three-dimensional complex geometry of the subdivertor were performed using the DIVGAS code based on the direct simulation Monte Carlo method and a model implemented in the steady-state thermal package in ANSYS, which are in agreement with the measured values during plasma operation.

Cryo-vacuum pumping↗

Investigation of the significance of excited species in wave-heated dense non-ideal microplasmas using particle-in-cell Monte Carlo-collision modeling

A computational model for the interaction of a high-pressure microplasma with an electromagnetic wave is presented. A one-dimensional particle-in-cell Monte Carlo collision model is used to investigate the plasma non-ideality effects in a second-stage laser-heated xenon plasma with a comprehensive chemistry mechanism, including excited species. A xenon microplasma at a temperature of 300 K and pressure of 10 bar becomes non-ideal after the laser heating stage with lower ionization and electronic excitation barriers, which makes the presence of excited species important to the plasma generation process. For these conditions, two-step ionization via excited species becomes a major contributor to plasma ionization. We find that full ionization of the plasma is obtained in ~2 ps when excited species are included in the chemistry model, as opposed to ~2.5 ps for a chemistry mechanism that does not consider their effect. With excited species, the ionization mode transitions from direct ionization via electron-neutral collisions to direct and stepwise ionization as the plasma generation progresses.

36 MATERIALS SCIENCE↗

Entry and Disposition of Zika Virus Immune Complexes in a Tissue Culture Model of the Maternal-Fetal Interface

Zika virus (ZIKV) infections have been associated with an increased incidence of severe microcephaly and other neurodevelopmental disorders in newborn babies. Passive immunization with anti-ZIKV neutralizing antibodies has the potential to become a feasible treatment or prophylaxis option during pregnancy. Prior to clinical use, such antibodies should be assessed for their ability to block ZIKV passage to the fetus. We used human placental and mammalian cell monolayers that express FcRn and laboratory preparations of anti-ZIKV antibodies as a model system to investigate the disposition of ZIKV/antibody immune complexes (ICs) at the maternal-fetal interface. We further characterized solution properties of the ICs to evaluate whether these are related to in vitro effects. We found that both ZIKV and ZIKV envelope glycoprotein can enter and passage through epithelial cells, especially those that overexpress FcRn. In the presence of ZIKV antibodies, Zika virus entry was bimodal, with reduced entry at the lowest (0.3–3 ng/mL) and highest (µg/mL) antibody concentrations. Intermediate concentrations attenuated inhibition or enhanced viral entry. With respect to anti-ZIKV antibodies, we found that their degradation was accelerated when presented as ICs containing increased amounts of ZIKV immunogen. Of the two monoclonal antibodies tested, the preparation with higher aggregation also exhibited higher degradation. Our studies confirm that intact Zika virus and its envelope immunogen have the potential to enter and be transferred across placental and other epithelial cells that express FcRn. Presence of anti-ZIKV IgG antibodies can either block or enhance cellular entry, with the antibody concentration playing a complex role in this process. Physicochemical properties of IgG antibodies can influence their degradation in vitro.

60 APPLIED LIFE SCIENCES↗

Study of Alfvén eigenmode stability in Quasi-Poloidal Stellarator (QPS) plasma using a Landau closure model

The aim of this study is to analyze the linear stability of Alfvén eigenmodes (AE) in the QPS device heated by a tangential neutral beam injector (NBI). The analysis is performed using the gyro-fluid code FAR3d, that solves the reduced MHD equations for the thermal plasma coupled with moments of the kinetic equation for the energetic particles (EP). The AE stability is calculated in several operational regimes of the tangential NBI: EP β between 0.001 and 0.1, EP energy between 12 and 180 keV and different radial locations of the beam. The analysis is performed for vacuum and finite β equilibria as well as QPS configurations with two and three periods. The EP β threshold in the vacuum case is 0.001 and the AE frequency is lower as the energy of the EP population decreases. Toroidal Alfvén eigenmodes with f = 80–120 kHz and elliptical AE between f = 120–350 kHz are triggered between the middle-outer plasma region ($r/a \gt 0.5$). The AE stability improves in the simulations with finite β equilibria and three period configurations with respect to the vacuum case with two periods because the continuum gaps are slender, leading to a higher threshold of the EP β, above 0.03 for the AEs triggered by the helical mode families. Helical effects are not strong enough to destabilize Helical Alfvén eigenmodes, the AEs with the largest growth rates are triggered by the n = 1 and n = 2 toroidal families.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for neutral long-lived particles that decay into displaced jets in the ATLAS calorimeter in association with leptons or jets using pp collisions at $\sqrt{\textrm{s}}$ = 13 TeV

A search for neutral long-lived particles (LLPs) decaying in the ATLAS hadronic calorimeter using 140 fb -1 of proton-proton collisions at $\sqrt{s}$ = 13 TeV delivered by the LHC is presented. The analysis is composed of three channels. The first targets pair-produced LLPs, where at least one LLP is produced with sufficiently low boost that its decay products can be resolved as separate jets. The second and third channels target LLPs respectively produced in association with a W or Z boson that decays leptonically. In each channel, different search regions target different kinematic regimes, to cover a broad range of LLP mass hypotheses and models. No excesses of events relative to the background predictions are observed. Higgs boson branching fractions to pairs of hadronically decaying neutral LLPs larger than 1% are excluded at 95% confidence level for proper decay lengths in the range of 30 cm to 4.5 m depending on the LLP mass, a factor of three improvement on previous searches in the hadronic calorimeter. The production of long-lived dark photons in association with a Z boson with cross-sections above 0.1 pb is excluded for dark photon mean proper decay lengths in the range of 20 cm to 50 m, improving previous ATLAS results by an order of magnitude. Finally, long-lived photo-phobic axion-like particle models are probed for the first time by ATLAS, with production cross-sections above 0.1 pb excluded in the 0.1 mm to 10 m range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

Assessment of Variability of the TEC in the Equatorial Anomaly Region with a Focus over Africa Using Rz and F10.7 as Input Drivers

This paper mainly intends to address the assessment of altitudinal variability of the vertical total electron content (VTEC) extracted from the Global Positioning System (GPS), the new versions of the International Reference Ionosphere Extended to the Plasmasphere (IRI-Plas 2017), and a quick-run ionospheric electron density (NeQuick 2) model in the equatorial anomaly region with a focus over Africa. This is manipulated employing the daily sunspot number (Rz) and 10.7 cm solar radio flux (F10.7) indices as the driver for the models during 2013–2016. The results show that the GPS-derived VTEC values are generally smaller than the modeled VTEC (IRI-Plas 2017 and NeQuick 2 VTEC) values, especially while utilizing the models with the Rz index. The modeled VTEC values are closer to the GPS VTEC values while using the models with the F10.7 index than Rz. The VTEC values obtained while using both models with the F10.7 index tend to increase while traversing from the high to the low solar activity years (especially in the March equinox and December solstice). The top-side ionospheric and plasmaspheric layers contribute the highest and lowest values to the total VTEC. Hence, the signal propagation through the ionosphere is largely affected when the signal crosses the top-side layer. Unlike other layers, due to the limited impact of the EUV on the ionization of neutral particles in the plasmasphere, the VTEC in the plasmaspheric layer (ECpl) shows smooth pattern with similar hourly values. Moreover, the IRI-Plas 2017 model does not effectively respond to the geomagnetic storm time variability of the VTEC with altitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

De novo design of monomeric helical bundles for pH ‐controlled membrane lysis

Abstract Targeted intracellular delivery via receptor‐mediated endocytosis requires the delivered cargo to escape the endosome to prevent lysosomal degradation. This can in principle be achieved by membrane lysis tightly restricted to endosomal membranes upon internalization to avoid general membrane insertion and lysis. Here, we describe the design of small monomeric proteins with buried histidine containing pH‐responsive hydrogen bond networks and membrane permeating amphipathic helices. Of the 30 designs that were experimentally tested, all expressed in Escherichia coli , 13 were monomeric with the expected secondary structure, and 4 designs disrupted artificial liposomes in a pH‐dependent manner. Mutational analysis showed that the buried histidine hydrogen bond networks mediate pH‐responsiveness and control lysis of model membranes within a very narrow range of pH (6.0–5.5) with almost no lysis occurring at neutral pH. These tightly controlled lytic monomers could help mediate endosomal escape in designed targeted delivery platforms.

59 BASIC BIOLOGICAL SCIENCES↗

Theoretical understanding of stability of the oxygen electrode in a proton-conductor based solid oxide electrolysis cell

The oxygen electrode in a proton-conductor based solid oxide cells is often a triple-conducting material that enables the transport and exchange of electrons (e - ), oxygen ions (O 2- ), and protons (H + ), thus expanding active areas to enhance the oxygen electrode activity. In this work, a theoretical model was developed to understand stability of tri-conducting oxygen electrode by studying chemical potentials of neutral species (i.e., μ o 2 , μ H 2 , and μ H 2 O ) as functions of transport properties, operating parameters, and cell geometry. Our theoretical understanding shows that (1): In a conventional oxygen-ion based solid oxide cell, a high μ o 2 (thus high oxygen partial pressure) exists in the oxygen electrode during the electrolysis mode, which may lead to the formation of cracks at the electrode/electrolyte interface. Further, while in a proton-conductor based solid oxide cell, the μ o 2 is reduced significantly, suppressing the crack formation, and resulting in improved performance stability (2). In a typical proton-conductor based solid oxide electrolyzer, the dependence of μ o 2 on the Faradaic efficiency is negligible. Hence, approaches to block the electronic current can improve the electrolysis efficiency while achieving stability (3). The difference of the μ o 2 (thus p o 2 ) between the oxygen electrode and gas phase can be reduced by using higher ionic conducting components and improving electrode kinetics, which lead to further improvement of electrode stability.

08 HYDROGEN↗