Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “network monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

DeepWelding: a Deep Learning Enhanced Approach to GTAW Using Multi-source Sensing Images

Deep learning has great potential to reshape manufacturing industries. In this paper, we present DeepWelding, a novel framework that applies deep learning techniques to improve gas tungsten arc welding (GTAW) process monitoring and penetration detection using multi-source sensing images. The framework is capable of analyzing multiple types of optical sensing images synchronously and consists of three deep learning enhanced consecutive phases: image preprocessing, image selection, and weld penetration classification. Specifically, we adopted generative adversarial networks (pix2pix) for image denoising and classic convolutional neural networks (AlexNet) for image selection. Both pix2pix and AlexNet delivered satisfactory performance. However, five individual neural networks with heterogeneous architectures demonstrated inconsistent generalization capabilities in the classification phase when holding out multi-source images generated with specific experimental settings. Therefore, two ensemble methods combining multiple neural networks were designed to improve the model performance on unseen data collected from different experimental settings. In conclusion, we also found that the quality of model prediction was heavily influenced by the data stream collection environment. We think these findings are beneficial for the broad intelligent welding community.

42 ENGINEERING↗

Systems Health Monitoring: Integrating FMEA into Bayesian Networks

The foreseeable high traffic density suggests that a large number of electric propulsion systems will enter the airspace, and that they will also operate at high frequency, e.g., large number of take offs and landings per unit time. The reliability of such critical systems is therefore key to ensure high safety standards in the low-altitude airspace. Diagnostic systems, which aim at identifying incipient faults, can mitigate unexpected failures or lower-than-expected reliability by performing early fault detection by monitoring the systems. A key element of fault diagnosis is fault detection and isolation (FDI), which complexity increases with the complexity of the system itself, namely the number of subsystems and components, interactions among sub-systems, and the number of sensors available. The proposed approach leverages combination of failure mode and effect analysis (FMEA) integrated with Bayesian networks, thus introducing dependability structures into a diagnostic framework to aid FDI. Faults and failure events from the FMEA are mapped within a Bayesian network, where network edges replicate the links embedded within FMEAs. The integrated framework enables the fault isolation process by identifying the probability of occurrence of specific faults or root causes given evidence observed through sensor signals. In this work, sub systems of Urban Air Mobility (UAM) type vehicle like avionics, structures, power-train etc. are taken into account to show the approach at the system level. This work integrates early design phase in the development of UAM type vehicles with diagnostic tools, which are often developed later in the product life-cycle, or retrofitted at a later time on systems. Failure mode and effect analysis (FMEA) derived for the system in the design phase is embedded within a Bayesian network (BN).

UAM↗

Advances in Geophysical Monitoring Methods To Support Groundwater Remedies

Monitoring plays an important role in supporting remedial investigations and selection of remedies for groundwater contamination and for assessing performance during implementation of remedies. When a groundwater plume is near the interface between groundwater and surface water, the dynamics of groundwater flow at this interface needs to be considered in the design and implementation of a remedy. For this and other aquifer situations, groundwater flow dynamics may be difficult to evaluate through groundwater head measurements due to a sparse monitoring-well network, a relatively flat hydraulic gradient, or the presence of induced gradients from pumping operations or groundwater mounds. Geophysical approaches, coupled with other targeted measurements or the use of an ionic tracer, provide temporal data that can quantify groundwater flow dynamics. Recent developments include a flux-monitoring tool that measures fluid conductivity, bulk conductivity, and temperature at the interface between groundwater and surface water. Joint interpretation of these local data with temporal two- or three-dimensional geophysical data improves quantification of groundwater and mass flux at a targeted location. In addition, geophysical design improvements that enable the use of numerical simulations to evaluate implementation configurations and expected data resolution for geophysical methods identify threshold conditions for successful monitoring and identify the most cost-effective configurations to meet monitoring objectives.

Strickland, Christopher E.↗

Advances in Geophysical Monitoring Methods to Support Groundwater Remedies - 19096

Monitoring plays an important role in supporting remedial investigations and selection of remedies for groundwater contamination and for assessing performance during implementation of remedies. When a groundwater plume is near the interface between groundwater and surface water, the dynamics of groundwater flow at this interface needs to be considered in the design and implementation of a remedy. For this and other aquifer situations, groundwater flow dynamics may be difficult to evaluate through groundwater head measurements due to a sparse monitoring-well network, a relatively flat hydraulic gradient, or the presence of induced gradients from pumping operations or groundwater mounds. Geophysical approaches, coupled with other targeted measurements or the use of an ionic tracer, provide temporal data that can quantify groundwater flow dynamics. Recent developments include a flux-monitoring tool that measures fluid conductivity, bulk conductivity, and temperature at the interface between groundwater and surface water. Joint interpretation of these local data with temporal two- or three-dimensional geophysical data improves quantification of groundwater and mass flux at a targeted location. In addition, geophysical design improvements that enable the use of numerical simulations to evaluate implementation configurations and expected data resolution for geophysical methods identify threshold conditions for successful monitoring and identify the most cost-effective configurations to meet monitoring objectives. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ambient monitoring to inform the protection of beneficial uses and achieve water quality goals in Sinclair and Dyes Inlets, Puget Sound, WA

Currently discharge limits enforced under the Clean Water Act are focused on meeting water quality standards at the end of the pipe and environmental performance is measured based on meeting the discharge limits; but meeting discharge limits has very little to do with achieving water quality goals for coastal and estuarine ecosystems. Therefore, an effective monitoring and assessment program is needed to assess continuous process improvement, evaluate the ecological conditions, and provide metrics that can inform effective management of coastal and estuarine water quality. As part of an integrated Environmental Investment (ENVVEST) project for Sinclair and Dyes Inlets (ENVVEST 2006; Johnston et al. 2009) a network of monitoring stations was established to characterize environmental conditions, assess potential impacts, and establish environmental quality trends within the Inlets. Water, sediment, and biota monitoring locations were selected that were co-located near suspected sources (industrial, waste water, and stormwater outfalls; marinas, stream mouths, and other sources) or were representative of ambient marine and nearshore conditions. Water column stations and effluents from industrial outfalls were sampled seasonally for trace metals (Cd, Cr, Cu, Hg, Pb, and Zn) using analytical procedures appropriate for seawater (Strivens, Brandenberger and Johnston, 2018), conventional parameters (salinity, dissolved and total organic carbon, total and suspended solids, dissolved O2, pH, turbidity, NO2+NO3, NH4, N, and P), and toxicity. Effluent and water column toxicity tests included mysid shrimp (Americamysis bahia) 96 hr survival, sand dollar (Dendraster excentricus) or purple sea urchin (Strongylocentrotus purpuratus) 96 hr embryo development, QwikLite – dinoflagellate (Pyrocystis lunula) 24 hr bioluminescence response, mussel larvae (Mytilus sp.) 48 hr larvae survival and development, and kelp (Macrocystis pyrifera) 48 hr growth and germination. Additionally, indigenous mussels (Mytilis spp.) were sampled biennially for contaminant residues of metals, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), lipid content, and stable isotopes of C and N. The mussel data were compared to benchmarks of ecological effects (Johnston et al. 2007, Applied Biomonitoring 2009), samples obtained from a local seafood market harvested from Penn Cove on Whidbey Island (PKPLPC), and data from the national mussel watch status and trends monitoring program (Kimbrough et al. 2008). Results from 2009-2016 showed that dissolved metals nearly always met water quality standards and that water quality in Navy nearshore areas appeared to improve after best management practices (BMPs) for industrial process improvements (US Navy 2012) were completed in Sept. 2013 (Figure 1). In general, toxicity from exposure to whole effluent samples was not observed and ambient water samples were not toxic to test organisms, except that ambient toxicity was only observed during the presence of algal blooms which showed that toxicity was highly correlated with the abundance of the toxic algae Gymnodinium splendens (Rosen et al. 2009). Overall, mussel tissue residues were below benchmarks at most locations (Figure 2), however there were locations that had elevated levels of PAHs, PCBs, Hg, and Cu. Results from the monitoring provide metrics that are being used to assess progress toward meeting environmental quality goals for the watershed.

ENVVEST, PSEMP↗

DOE site remedial management optimization utilizing on the cloud computing systems - 15676

Environmental cleanups at complex sites necessarily address many competing demands and answer questions such as: 'What is the best way and in a sustainable manner to minimize risk to human health and the environment during active restoration efforts and/or long term legacy management, while incorporating parameter uncertainty, management considerations, and stakeholder concerns into the process?' Physics Based Management Optimization (PBMO{sup TM}) provides a means to answer such questions. 'Physics Based' indicates incorporation of numerically computed groundwater flow and transport processes into the analysis. This enables optimal remedy design based on comprehensive mass removal/destruction metrics and optimal monitoring strategies. 'Management Optimization' indicates the ability to incorporate objective functions (e.g., management constraints, sustainability considerations) into the evaluation. PBMO{sup TM} components have been successfully implemented for optimal plume delineation (points of compliance) and monitoring, for optimal system design and to optimize existing active treatment systems in the US at multiple DOE, DOD and industrial sites since the mid 1990's. PBMO{sup TM} has been recently extended and implemented on multi-core, multi-CPU grid computing systems including computational clusters, local area networks and the Cloud. This extension allows for increased flexibility and adaptation of computational resources which can now support optimal remedy design and long term management strategies for complex soil and groundwater sites. In the PBMO{sup TM} -Grid case study, we evaluate flow and transport for a typical optimization search for a realistic project against sequential optimization. PBMO{sup TM}-Grid reduces the CPU time required to solve the optimization problem by more than a factor of 14 X compared to sequential optimization. PBMO{sup TM}-Grid can be deployed for deterministic or stochastic optimization and formally computes design risk and predicted degree of remedial action success. The numerical models used can consist of a single 'mega' model (aka a monolith), or a mixture of models and other calculations or expert systems. PBMO{sup T}M-Grid integrates the computational models in a seamless manner, and models run on the Cloud can be implemented in Windows or Linux platforms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-situ sensor monitoring of multi-class gas porosity formation in laser powder bed fusion using convolutional neural network

In-situ monitoring of defect formation remains a significant challenge in the laser powder bed fusion (LPBF) process. Recent advances have enabled real-time defect detection with machine learning and in-situ sensing technologies; however, most studies focus on binary classification of keyhole pores, limiting nuanced multi-class pore differentiation and formation mechanisms. This work introduces a multi-class pore detection framework (no pore, small pores < 15 µm, and large pores > 15 µm) by leveraging photodiode sensor data alongside high-fidelity synchrotron X-ray imaging. The 15 µm threshold is selected to distinguish between two fundamentally different defect mechanisms, following the physical size-mechanism boundary established by prior high-resolution synchrotron X-ray characterization of Al6061 LPBF. Distinguishing these classes is critical because large keyhole pores are structurally detrimental, whereas small gas pores are often benign, requiring different process control strategies. Thermal emission monitoring data collected simultaneously with high-speed X-ray imaging at the Stanford Synchrotron Radiation Lightsource (SSRL), are correlated with subsurface melt pool dynamics to establish ground truth. Continuous Wavelet Transform (CWT) with optimized parameters converts the photodiode time-series signals into time–frequency images, facilitating feature extraction. Convolutional Neural Networks (CNN) are then applied for real-time multi-class pore classification in an average inference time of 1 ms per signal window. It achieves 79% accuracy and an Area Under the Receiver Operating Characteristic curve (AUC ROC) score of 0.89 with five-fold cross-validation. The results demonstrate that coupling CWT-based feature engineering with CNN architecture enables reliable multi-class pore detection in Al6061 builds using affordable in-situ sensors. This approach advances scalable and affordable quality assurance in additive manufacturing by moving beyond binary defect detection toward more nuanced classification of porosity mechanisms with in-situ sensors and machine learning.

Laser powder bed fusion, Multi-class pores, In-sit↗

Entanglement transitions from restricted Boltzmann machines

The search for novel entangled phases of matter has lead to the recent discovery of a new class of “en- tanglement transitions,” exemplified by random tensor networks and monitored quantum circuits. Most known examples can be understood as some classical ordering transitions in an underlying statistical mechanics model, where entanglement maps onto the free-energy cost of inserting a domain wall. In this paper we study the possibility of entanglement transitions driven by physics beyond such statistical mechanics mappings. Motivated by recent applications of neural-network-inspired variational Ansätze, we investigate under what conditions on the variational parameters these Ansätze can capture an entanglement transition. We study the entanglement scaling of short-range restricted Boltzmann machine (RBM) quantum states with random phases. For uncorrelated random phases, we analytically demonstrate the absence of an entanglement transition and reveal subtle finite-size effects in finite-size numerical simulations. Introducing phases with correlations decaying as 1/r α in real space, we observe three regions with a different scaling of entanglement entropy depending on the exponent α. We study the nature of the transition between these regions, finding numerical evidence for critical behavior. Furthermore, our work establishes the presence of long-range correlated phases in RBM-based wave functions as a required ingredient for entanglement transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Homogenized Ground-Based and Profile Ozone Datasets From the TOAR-II/HEGIFTOM Project: Methods and Station Trends

Within the framework of the second phase of the Tropospheric Ozone Assessment Report (TOAR-II), it was recognized that an essential first step for deriving accurate trends from the ground-based networks that monitor ozone in the free troposphere is putting the measurements on the same basis with respect to absolute references and processing methods. The relevant procedures are referred to as “harmonization” or “homogenization”. The TOAR II working group, “HEGIFTOM” (Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements), has carried out harmonization for five types of network (Figure below) instruments (mid-1990s to 2020): ozonesondes, commercial aircraft IAGOS landing/takeoff profiles, Fourier-Transform Infrared spectrometer (FTIR), tropospheric Lidar, and Brewer/Dobson Umkehr. First, we summarize the homogenization effort for each network that provides new quality-assessed ozone profile or segment (partial column) data sets, including uncertainty estimates and quality flags. Second, with the HEGIFTOM datasets forming the basis for a global assessment of tropospheric ozone column trends, results derived with various trend detection algorithms will be presented. The ultimate goal is evaluation of the consistency of the calculated trends among different techniques at selected stations and/or regions.

ozone↗

Launch Complex 39A, SWMU 008 2023 Long-Term Monitoring Report Kennedy Space Center, Florida

The 2023 Long-Term Monitoring (LTM) Report (LTMR) presents the annual and semi-annual groundwater monitoring results for Launch Complex 39A (LC39A), Solid Waste Management Unit (SWMU) 008, at Kennedy Space Center (KSC), Florida. The reporting period covered under this LTMR is from January to December 2023, and represents the first year of site-wide monitoring following Air Sparge (AS) system shutdown at the end of 2022. AS system operation at LC39A began operation in 2015. The AS system consisted of a total of 173 AS wells ranging in depth from 11 to 37 feet below land surface. The overall remedial objective for the AS Interim Measure was to actively decrease concentrations of COCs to less than their respective Florida Department of Environmental Protection Natural Attenuation Default Concentrations, so that LC39A can transition into an LTM program. This objective was achieved in 2022, with 2023 marking Year 1 of the LTM program to monitor the residual groundwater plume. VOC results indicate that COC concentrations have continued to decrease or stabilize, with no rebound observed since AS system shutdown. Vinyl chloride was the only COC detected above its GCTL, with the highest concentration detected at 8.0 μg/L. PFAS results detected 15 different PFAS compounds (out of 32 analyzed) between the six monitoring wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). PFOS was detected in one of the six samples above the FDEP Provisional GCTL at a concentration of 200 ng/L. PFOA was not detected above the FDEP Provisional GCTL in any of the six samples. PFOS and PFOA also currently have United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 ng/L. PFOS was detected in all six samples above the USEPA MCL. PFOA was detected in three of the six samples above the USEPA MCL. Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the six wells. Additional PFAS sampling will occur as part of a PFAS Site Assessment to be conducted in the future. Based on Year 1 LC39A LTM results, recommendations for 2024 are to continue with the second year of LTM in 2024 with the same monitoring well network as Year 1 (18 wells). The three wells that were on a semi-annual schedule will transition to an annual schedule to align with the remaining wells. The next annual event is scheduled for May 2024. The three wells that were found to be inadvertently destroyed will be properly abandoned and a replacement well in the vicinity of former monitoring well 21ST-MW0030I will be installed. This new well will be added to the LTM sampling plan upon installation.

Deborah M. Wilson↗

Occupancy prediction through machine learning and data fusion of environmental sensing and Wi-Fi sensing in buildings

Occupancy information is crucial to building facility design, operation, and energy efficiency. Many studies propose the use of environmental sensors (such as carbon dioxide, air temperature, and relative humidity sensors) and radio-frequency sensors (Wi-Fi networks) to monitor, assess, and predict occupancy information for buildings. As many methods have been developed and a variety of sensory data sources are available, establishing a proper selection of model and data source is critical to the successful implementation of occupancy prediction systems. This study compared three popular machine learning algorithms, including k-nearest neighbors (kNN), support vector machine (SVM), and artificial neural network (ANN), combined with three data sources, including environmental data, Wi-Fi data, and fused data, to optimize the occupancy models’ performance in various scenarios. Three error measurement metrics, the mean average error (MAE), mean average percentage error (MAPE), and root mean squared error (RMSE), have been employed to compare the models’ accuracies. Examined with an on-site experiment, the results suggest that the ANN-based model with fused data has the best performance, while the SVM model is more suitable with Wi-Fi data. The results also indicate that, comparing with independent data sources, the fused data set does not necessarily improve model accuracy but shows a better robustness for occupancy prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using a physics-informed neural network and fault zone acoustic monitoring to predict lab earthquakes

Abstract Predicting failure in solids has broad applications including earthquake prediction which remains an unattainable goal. However, recent machine learning work shows that laboratory earthquakes can be predicted using micro-failure events and temporal evolution of fault zone elastic properties. Remarkably, these results come from purely data-driven models trained with large datasets. Such data are equivalent to centuries of fault motion rendering application to tectonic faulting unclear. In addition, the underlying physics of such predictions is poorly understood. Here, we address scalability using a novel Physics-Informed Neural Network (PINN). Our model encodes fault physics in the deep learning loss function using time-lapse ultrasonic data. PINN models outperform data-driven models and significantly improve transfer learning for small training datasets and conditions outside those used in training. Our work suggests that PINN offers a promising path for machine learning-based failure prediction and, ultimately for improving our understanding of earthquake physics and prediction.

42 ENGINEERING↗

A Tool for Verification and Validation of Neural Network Based Adaptive Controllers for High Assurance Systems

High reliability of mission- and safety-critical software systems has been identified by NASA as a high-priority technology challenge. We present an approach for the performance analysis of a neural network (NN) in an advanced adaptive control system. This problem is important in the context of safety-critical applications that require certification, such as flight software in aircraft. We have developed a tool to measure the performance of the NN during operation by calculating a confidence interval (error bar) around the NN's output. Our tool can be used during pre-deployment verification as well as monitoring the network performance during operation. The tool has been implemented in Simulink and simulation results on a F-15 aircraft are presented.

Gupta, Pramod↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Networks in Motion Mobile Sensorweb

Advanced mobile networking technology applicable to mobile sensor platforms was developed, deployed and demonstrated. A two-tier sensorweb design was developed. The first tier utilized mobile network technology to provide mobility. The second tier, which sits above the first tier, utilizes 6LowPAN (Internet Protocol version 6 Low Power Wireless Personal Area Networks) sensors. The entire network was IPv6 enabled. Successful mobile sensorweb system field tests took place in late August and early September of 2009. The entire network utilized IPv6 and was monitored and controlled using a remote Web browser via IPv6 technology. This paper describes the mobile networking and 6LowPAN sensorweb design, implementation, deployment and testing as well as wireless systems and network monitoring software developed to support testing and validation.

Ivancic, William D.↗

Evaluation of Sampling Inlets for Continuous Air Monitors in Calm Air Conditions

The Canberra NetCAM (networked continuous air monitor) can be operated with a radial inlet attachment from the manufacturer. Sampled aerosol can be transported through large diameter tubing from a desired location to the NetCAM sampler. In this assessment, the effect of the addition of the radial inlet was investigated. Also, a sampling system consisting of a vertical sample tube and a 90-degree elbow (to the horizontal plane) was evaluated by empirical calculations with the DEPO software. Generalized aspiration ratio calculations were done with the empirical model from Vincent. Three different sample probe types were also experimentally tested. In summary: (1) For typical room air conditions, the addition of the Canberra inline adapter to the NetCAM has no discernible effect on system performance. This was determined by literature search with a previously published study. (2) The DEPO software (US NRC / Texas A&M University) was used to show the effect of adding a 2-meter high vertical tube and a ninety-degree tube bend to a sampling inlet. In this example, there was a total penetration of 97.7% of 10-micron diameter aerosol particles for an air flowrate of 2.0 ACFM (actual cubic feet per minute). (3) Calculations of nozzle aspiration ratio (for general, non-specific situations) were performed using the Vincent empirical model. For example, in typical room air, where the average velocity is less than 0.5 m/sec, an aerosol inlet probe has a calculated aspiration ratio (or penetration efficiency) value between 98 and 100%, depending on the angle of the probe inlet compared to the direction of the incoming air velocity vector. A table of nozzle aspiration ratios was generated for a range of different room air velocities and probe inlet angles. (4) Three different candidate probe geometries were tested, (A) a probe with a vertical entry and vertical transport tube, (B) a probe with a horizontal entry and vertical transport tube, and (C) a ‘widemouth’ probe with a vertical entry and vertical transport tube. The experimentally determined values were 98%, 102%, and 100%, respectively, for the aerosol penetration into these inlets. In conclusion, the addition of a complete sampling system with probe inlet, a short length of sampling lines and the radial inlet would still be able to deliver about 95% of the sampled aerosol from the sampling location to the Canberra NetCAM.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Gaussian Process Based Online Change Detection Algorithm for Monitoring Periodic Time Series

Online time series change detection is a critical component of many monitoring systems, such as space and air-borne remote sensing instruments, cardiac monitors, and network traffic profilers, which continuously analyze observations recorded by sensors. Data collected by such sensors typically has a periodic (seasonal) component. Most existing time series change detection methods are not directly applicable to handle such data, either because they are not designed to handle periodic time series or because they cannot operate in an online mode. We propose an online change detection algorithm which can handle periodic time series. The algorithm uses a Gaussian process based non-parametric time series prediction model and monitors the difference between the predictions and actual observations within a statistically principled control chart framework to identify changes. A key challenge in using Gaussian process in an online mode is the need to solve a large system of equations involving the associated covariance matrix which grows with every time step. The proposed algorithm exploits the special structure of the covariance matrix and can analyze a time series of length T in O(T^2) time while maintaining a O(T) memory footprint, compared to O(T^4) time and O(T^2) memory requirement of standard matrix manipulation methods. We experimentally demonstrate the superiority of the proposed algorithm over several existing time series change detection algorithms on a set of synthetic and real time series. Finally, we illustrate the effectiveness of the proposed algorithm for identifying land use land cover changes using Normalized Difference Vegetation Index (NDVI) data collected for an agricultural region in Iowa state, USA. Our algorithm is able to detect different types of changes in a NDVI validation data set (with ~80% accuracy) which occur due to crop type changes as well as disruptive changes (e.g., natural disasters).

54 ENVIRONMENTAL SCIENCES↗

Launch Complex 34, SWMU CCO542022 DNAPL Source Zone Operations, Maintenance, and Monitoring, Site-Wide Long-Term Monitoring, and Hot Spot 6 Air Sparge System Annual Performance Monitoring Report Cape Canaveral Space Force Station, Florida

This Annual Performance Monitoring Report (PMR) for the Dense Non-Aqueous Phase Liquid (DNAPL) Source Zone (DSZ), Site-Wide Long-Term Monitoring (LTM), and Hot Spot (HS) 6 Air Sparge (AS) System presents the results of Year 13 operation of the hydraulic containment (HC) Interim Measure (IM), the results of performance monitoring direct-push technology (DPT) sampling and monitoring well sampling conducted in the DSZ, results of the biennial site-wide LTM event, and the results of operations and performance sampling of the HS 6 AS IM at Launch Complex 34 (LC34), located at Cape Canaveral Space Force Station (CCSFS), Florida. This site has been designated Solid Waste Management Unit (SWMU) CC054 under the Kennedy Space Center (KSC) Resource Conservation and Recovery Act (RCRA) Corrective Action Program. For the site-wide biennial LTM event, a total of 55 monitoring wells were sampled for volatile organic compounds (VOCs) in February 2023 and one well was sampled for polychlorinated biphenyls (PCBs) in December 2022. One well planned for VOC sampling was found to be destroyed and could not be sampled (CW0002). The LTM wells are screened in two lithologic zones: Layer 1 (0 to 25 feet below land surface [bls]) and Layer 2 (25 to 30 ft bls), and are located in the outlying areas of LC34 to monitor groundwater conditions within the Low-Concentration Plume (LCP), defined as concentrations exceeding Groundwater Cleanup Target Levels (GCTLs), and the High-Concentration Plume (HCP), defined as concentrations exceeding Natural Attenuation Default Concentrations (NADCs). Results from the biennial sampling event indicated overall plume stability and delineation for the plume, which extends over 300 acres. The operational period for Year 13 of the HCS was from April 1, 2022 to March 31, 2023. Operational runtime for the system was 90 percent during Year 13, with downtime events attributed to planned maintenance, system repairs, and power outages. As of March 31, 2023, a total of 313,673,241 cumulative gallons of groundwater containing 88,337 pounds of VOCs have been removed by the HCS. Influent concentrations of trichloroethene (TCE) have decreased since startup from approximately 280,000 μg/L (January 2010) to 12,000 μg/L (March 2023). During the reporting period, all effluent concentrations from the HCS (aqueous and vapor) were below regulatory reporting limits, indicating the system continues to operate as intended. Performance monitoring was conducted in December 2022 within the DSZ to evaluate TCE contamination. Groundwater samples were collected via DPT at nine locations, consistent with previous events between 2017 and 2021. Full vertical profile sampling was completed at each DPT from 8 to 98 feet bls, at 5-foot intervals. The DPT performance monitoring results are summarized in this PMR. The results revealed TCE remains at concentrations greater than 11,000 μg/L in the DSZ (1-percent solubility, indicative of DNAPL) at eight of the nine DPT locations and at depths ranging from 8 to 98 feet bls. In addition to DPT sampling, groundwater samples were collected from deep monitoring wells in the DSZ area (Layers 7 and 8) in December 2022 to verify vertical delineation. Layer 7/8 monitoring well results were non-detect in December 2022, with exception of three wells (IW0162, IW043D2, and IW044D2), where TCE, cis-1,2-dichloroethene (cDCE), and/or vinyl chloride (VC) were detected above GCTLs. These wells are screened 105 to 115 feet bls, which is below the existing recovery well capture zone. TCE was first detected in IW0162 in December 2021 and has since been sampled at least monthly to monitor TCE concentrations. The maximum TCE concentration during this operational period was 15,000 μg/L at IW0162 in March 2023. Because of the increased TCE concentrations in this well, a new recovery well (RW21D), screened 86 to 106 feet bls, was installed in January 2023 and incorporated into existing HCS operations. The HS 6 AS IM was initiated in 2018 with 160 AS wells, and expanded in 2019 with an additional 140 AS wells. Quarterly performance monitoring was reduced to semi-annual in 2020. The HS 6 AS system remained operational during the reporting period covered under this report. The results of the HS 6 system operation and semi-annual performance monitoring are summarized in this report. Semi-annual monitoring results collected in April and October 2022 show concentrations of contaminants of concern (cDCE, trans-1,2-dichloroethene, and vinyl chloride) are generally decreasing and not impacting the surface water drainage canal, indicating the HS 6 IM is meeting objectives. A Phase Two Expansion of the HS 6 AS IM was recently completed. As of the date of this report, the expansion became operational in August 2023 and the first quarter of monitoring was conducted in November 2023. Details of the construction, start-up, and performance monitoring will be included in a future Annual PMR. Overall, the tasks associated with Year 13 operation of the HC IM, operation of the HS 6 AS IM, and biennial site-wide sampling were performed in accordance with recommendations included in the previous 2021 LC34 (Year 12) annual report. Evaluation of results from the HC IM and HS 6 IM show that these systems are operating as designed and meeting performance objectives. Results from the site-wide biennial LTM program also show that the overall network of monitoring wells is adequate to continue monitoring plume-wide conditions.

Complex 34↗