Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Measurement of the non-prompt D-meson fraction as a function of multiplicity in proton-proton collisions at $\sqrt{s}$ = 13 TeV

The fractions of non-prompt (i.e. originating from beauty-hadron decays) D 0 and D + mesons with respect to the inclusive yield are measured as a function of the charged-particle multiplicity in proton-proton collisions at a centre-of-mass energy of $\sqrt{s}$ = 13 TeV with the ALICE detector at the LHC. The results are reported in intervals of transverse momentum (pT) and integrated in the range 1 < p T < 24 GeV/c. The fraction of non-prompt D 0 and D + mesons is found to increase slightly as a function of p T in all the measured multiplicity intervals, while no significant dependence on the charged-particle multiplicity is observed. In order to investigate the production and hadronisation mechanisms of charm and beauty quarks, the results are compared to PYTHIA 8 as well as EPOS 3 and EPOS 4 Monte Carlo simulations, and to calculations based on the colour glass condensate including three-pomeron fusion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of Two Types of Double-J Ureteral Stents that Differ in Diameter and the Existence of Multiple Side Holes along the Straight Portion in Malignant Ureteral Strictures

PurposeThis study was decided to evaluate the impact of diameter and the existences of multiple side holes along the straight portion of double-J ureteral stents (DJUS) on early dysfunction of stents placed for malignant ureteral strictures.MethodsBetween April 2007 and December 2011, 141 DJUSs were placed via a percutaneous nephrostomy (PCN) tract in 110 consecutive patients with malignant ureteral strictures. 7F DJUSs with multiple side holes in the straight portion were placed in 58 ureters of 43 patients (Group 1). 8F DJUSs with three side holes in the proximal 2-cm of the straight portion were placed in 83 ureters of 67 patients (Group 2). The incidence of early DJUS dysfunction was compared between the two groups, and nephrostographic findings were evaluated in the cases of early dysfunction.ResultsEarly dysfunction of the DJUS was noted in 14 of 58 patients (24.1 %) in Group 1, which was significantly higher (p = 0.001) than in Group 2 in which only 1 of 83 patients (1.2 %) had early dysfunction of the DJUS. Nephrostographic findings of early dysfunction included dilatation of the pelvicalyceal system, filling defects in the ureteral stent, and no passage of contrast media into the urinary bladder.ConclusionsIn malignant ureteral strictures, multiple side holes in the straight portion of the 7-F DJUS seem to cause early dysfunction. The 8F DJUSs with three side holes in the proximal 2-cm of the straight portion may be superior at preventing early dysfunction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancement of responsivity and speed in waveguide Ge/Si avalanche photodiode with separate vertical Ge absorption, lateral Si charge and multiplication configuration

Waveguide-coupled Ge/Si separate absorption, charge and multiplication avalanche photodiodes (SACM APDs) have shown significant potential as high-sensitivity, low-noise, and high-speed photo-detection for optical communications. Here we present a nanoscale single-mode waveguide-integrated vertical Ge absorption, lateral Si charge and single multiplication configuration for a waveguide Ge/Si SACM APD. This device can achieve 90% absorption at 1550 nm wavelengths with a 10 μm-long Ge layer. The device exhibits a seven times reduction in device length compared to conventional waveguide structures and a 29% increase compared to multi-mode interference coupling. Meanwhile, a 3-dB bandwidth can achieve 47 GHz, which is five times higher than the conventional vertical Ge absorption, lateral Si charge and multiplication devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Simultaneous photonic generation of multiple chirp and unchirp microwave waveform with frequency multiplying capability for optical beam forming system

A photonic technique based on the Mach–Zehnder Modulator and the dual parallel Mach–Zehnder modulator is proposed for the simultaneous generation of multiple chirp and unchirp microwave waveform with frequency multiplying capability for efficient beam steering applications. There is provision to obtain a single chirp signal of a particular center frequency and chirp rate from a multiple chirp signal without any alternation in the experimental setup. In the proposed methodology, the PIN photodetector is used for the detection of 12 GHz unchirp microwave waveform showing the frequency doubling characteristics and the balance photodetector is used for the detection of multiple chirp signal with frequency components 6, 12, and 18 GHz. The same experimental setup is used to generate dual linear chirp microwave signal of 12 GHz center frequency. This can be achieved by adjusting the bias voltage of the phase modulator. Time bandwidth product and bandwidth of the signal are 18.33 and 410 MHz, respectively. This technique is tunable in frequency, but the generation of higher frequency microwave signals is limited by the speed and bandwidth of the Mach–Zehnder Modulator and photodetector. The novelty of our proposed scheme is that we are going to drive MZM by chirp RF signal to multiply the chirp rate in manifold. To the best of our knowledge the effect of chirp microwave signal on photonic highly steerable beam forming system has not yet been studied experimentally in past, which we are targeting under this paper. It is expected that the range of beam steering performance should be improved substantially as compared to previously reported results.

42 ENGINEERING↗

Influence of Exposure to Multiple Brazing Cycles on the Integrity of OFE Copper Brazed Joints

A 10 MeV, 5 kW S-band travelling wave electron linear accelerator has been developed at Raja Ramanna Centre for Advanced Technology for industrial applications. The electron accelerating structure is made of oxygen-free electronic (OFE) copper and comprises of fifty-six brazed joints and is fabricated in multiple stages, as per the process and testing requirements. The accelerating structure is often required to be repaired through an additional brazing cycle with the same filler. The present study evaluates possible microstructural and mechanical property degradation of OFE copper brazed joints, as a result of its exposure to multiple brazing cycles. The study was performed on an OFE copper cavity stack brazed assembly, made through a four-stage brazing using BVAg-8 as braze filler. The resultant brazed assembly did not exhibit any leak at a sensitivity of 1 × 10{sup −10} mbar.L/s. The results of the study demonstrate that OFE copper brazements can be safely subjected to an additional brazing cycle without causing significant degradation in its microstructure and strength. However, brazed joint’s exposure to any additional brazing cycles results in the formation of voids and cracks due to intergranular penetration of silver, with associated drop in tensile strength from about 210 MPa to about 150-180 MPa. Based on the results of study, it is recommended to qualify the accelerating structure, fabricated through multiple brazing cycles, by a suitable non-destructive technique. The results of the study are important for design, fabrication and maintenance of electron linear accelerator components.

36 MATERIALS SCIENCE↗

Effects of Multiple Laser Peening impacts on Mechanical Properties and Microstructure Evolution of 40CrNiMo Steel

The effects of multiple laser peening impacts on mechanical properties and microstructure of 40CrNiMo steel were investigated. The surface residual stress and microhardness of the samples with different treatments were measured. The surface morphologies, tensile behavior and microstructure of the samples before and after laser peening were compared and analyzed. The experimental results showed that laser peening, especially multiple laser peening impacts has significant effects on the microhardness, residual stress and microstructure of 40CrNiMo steel. The surface roughness and the depth of the pit increased with increasing the impact times. After 3 laser peening impacts, the surface microhardness, compressive residual stress, the strength and ductility were significantly improved. Meanwhile, some microstructures, such as sub-grains, the precipitation of carbide and dislocations were also induced in the surface layer. Additionally, the microscopic strengthening mechanism of multiple laser peening impacts on the mechanical properties of 40CrNiMo steel was analyzed in detail.

36 MATERIALS SCIENCE↗

Determining heterogeneous slip activity on multiple slip systems from single crystal orientation pole figures

A new experimental method to determine heterogeneity of shear strains associated with crystallographic slip in the bulk of ductile, crystalline materials is outlined. The method quantifies the time resolved evolution of misorientation within plastically deforming crystals using single crystal orientation pole figures (SCPFs) measured in-situ with X-ray diffraction. A multiplicative decomposition of the crystal kinematics is used to interpret the distributions of lattice plane orientation observed on the SCPFs in terms of heterogeneous slip activity (shear strains) on multiple slip systems. Here, to show the method’s utility, the evolution of heterogeneous slip is quantified in a silicon single crystal plastically deformed at high temperature at multiple load steps, with slip activity in sub-volumes of the crystal analyzed simultaneously.

36 MATERIALS SCIENCE↗

SENP1 inhibition induces apoptosis and growth arrest of multiple myeloma cells through modulation of NF-κB signaling

SUMO/sentrin specific protease 1 (Senp1) is an important regulation protease in the protein sumoylation, which affects the cell cycle, proliferation and differentiation. The role of Senp1 mediated protein desumoylation in pathophysiological progression of multiple myeloma is unknown. In this study, we demonstrated that Senp1 is overexpressed and induced by IL-6 in multiple myeloma cells. Lentivirus-mediated Senp1 knockdown triggers apoptosis and reduces viability, proliferation and colony forming ability of MM cells. The NF-κB family members including P65 and inhibitor protein IkBα play important roles in regulation of MM cell survival and proliferation. We further demonstrated that Senp1 inhibition decreased IL-6-induced P65 and IkBα phosphorylation, leading to inactivation of NF-kB signaling in MM cells. These results delineate a key role for Senp1in IL-6 induced proliferation and survival of MM cells, suggesting it may be a potential new therapeutic target in MM. - Highlights: • Senp1 is overexpressed and induced by IL-6 in multiple myeloma cells. • Senp1 knockdown triggers apoptosis and reduces proliferation of MM cells. • Senp1 inhibition decreased IL-6-induced P65 and IkBα phosphorylation.

60 APPLIED LIFE SCIENCES↗

Multiple myeloma cells adapted to long-exposure of hypoxia exhibit stem cell characters with TGF-β/Smad pathway activation

Highlights: • Hypoxia-adapted multiple myeloma cells exhibit stem cell characteristics. • Hypoxia-adapted multiple myeloma cells show higher tumorigenicity in vivo. • TGF-β/Smad pathway is critical for self-renewal for hypoxia-adapted myeloma cells. The emergence of new molecular targeting agents has improved the prognosis of patients with multiple myeloma (MM). However, MM remains incurable because MM stem cells are likely resistant to these agents. Thus, it is important to further investigate the biology of MM stem cells, which reside in the hypoxic bone marrow niche. In this study, we established and investigated the characteristics of hypoxia-adapted MM (HA-MM) cells, which could proliferate for more than six months under hypoxic conditions (1% O{sub 2}). The G0 fraction of HA-MM cells was larger than that of parental MM cells under normoxic conditions (20% O{sub 2}). HA-MM cells possess enhanced tumorigenicity in primary and secondary transplantation studies. HA-MM cells also exhibited increased mRNA levels of stem cell markers and an enhanced self-renewal ability, and thus demonstrated characteristics of MM stem cells. These cells overexpressed phosphorylated Smad2, and treatment with a transforming growth factor (TGF)-β/Smad signaling inhibitor decreased their clonogenicity in a replating assay. In conclusion, MM cells adapted to long-exposure of hypoxia exhibit stem cell characters with TGF-β/Smad pathway activation.

60 APPLIED LIFE SCIENCES↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Simple and Efficient Methodology To Improve Geometric Accuracy in Gamma Knife Radiation Surgery: Implementation in Multiple Brain Metastases

Purpose: To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. Methods and Materials: The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, “average” image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (<2 cm) metastases treated with GK radiation surgery. Results: Phantom study results showed that use of average MR images eliminates the effect of sequence-dependent distortions, leading to a total spatial uncertainty of less than 0.3 mm, attributed mainly to gradient nonlinearities. In brain metastases patients, non-eliminated sequence-dependent distortions lead to target localization uncertainties of up to 1.3 mm (mean: 0.51 ± 0.37 mm) with respect to the corresponding target locations in the “average” MRI series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. Conclusions: The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of alveolar mixing and multiple breaths of aerosol intake on particle deposition in the human lungs

Predictive dosimetry models play an important role in assessing health effect of inhaled particulate matter and in optimizing delivery of inhaled pharmaceutical aerosols. Here, in this study, the commonly used 1D Multiple-Path Particle Dosimetry model (MPPD) was improved by including a mechanistically based model component for alveolar mixing of particles and by extending the model capabilities to account for multiple breaths of aerosol intake. These modifications increased the retained fraction of particles and consequently particle deposition predictions in the deep lung during tidal breathing. Comparison with an existing dataset (J. Aerosol Sci., 99:27-39, 2016) obtained under two breathing conditions referred to as slow and fast breathing showed significant differences in 1 µm particle deposition between predictions (slow: 30±1%, fast: 21±1%) and measurements (slow: 43±9%, fast: 30±5%) when the prior version of MPPD (single breath and no mixing, J. Aerosol Sci., 151:105647, 2021) was used. Adding a mixing model and multiple breaths moved the predictions (slow: 34±2%, fast:25±2%) closer to the range of deposition measurements. For 2.9 µm particles, predictions from both the original (slow: 70±2%, fast: 57±2%) and the revised MPPD model (slow: 71±2%, fast: 59±3%) compared well with experiments (slow: 67±8%, fast: 58±10%). This was expected as suspended fraction of 2.9 µm particles was small and thus the addition of alveolar mixing and multi breath capability only slightly increased the retained fraction for particles of this size and greater. The revised 1D model improves dose predictions in the deep lung and support human risk assessment from exposure to airborne particles.

60 APPLIED LIFE SCIENCES↗

Hybrid approaches for multiple-species stochastic reaction–diffusion models

Reaction–diffusion models are used to describe systems in fields as diverse as physics, chemistry, ecology and biology. The fundamental quantities in such models are individual entities such as atoms and molecules, bacteria, cells or animals, which move and/or react in a stochastic manner. If the number of entities is large, accounting for each individual is inefficient, and often partial differential equation (PDE) models are used in which the stochastic behaviour of individuals is replaced by a description of the averaged, or mean behaviour of the system. In some situations the number of individuals is large in certain regions and small in others. In such cases, a stochastic model may be inefficient in one region, and a PDE model inaccurate in another. To overcome this problem, we develop a scheme which couples a stochastic reaction–diffusion system in one part of the domain with its mean field analogue, i.e. a discretised PDE model, in the other part of the domain. The interface in between the two domains occupies exactly one lattice site and is chosen such that the mean field description is still accurate there. In this way errors due to the flux between the domains are small. Our scheme can account for multiple dynamic interfaces separating multiple stochastic and deterministic domains, and the coupling between the domains conserves the total number of particles. The method preserves stochastic features such as extinction not observable in the mean field description, and is significantly faster to simulate on a computer than the pure stochastic model. - Highlights: • A novel hybrid stochastic/deterministic reaction–diffusion simulation method is given. • Can massively speed up stochastic simulations while preserving stochastic effects. • Can handle multiple reacting species. • Can handle moving boundaries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Is a single isocenter sufficient for volumetric modulated arc therapy radiosurgery when multiple intracranial metastases are spatially dispersed?

Previous work demonstrated improved dosimetry of single isocenter volumetric modulated arc therapy (VMAT) of multiple intracranial targets when they are located ≤ 4 cm from isocenter because of narrower multileaf collimators (MLCs). In follow-up, we sought to determine if decreasing isocenter-target distance (d{sub iso}) by using 2 to 3 isocenters would improve dosimetry for spatially dispersed targets. We also investigated the effect of a maximum dose constraint during VMAT optimization, and the dosimetric effect of the number of VMAT arcs used for a larger number of targets (i.e., 7 to 9). We identified radiosurgery cases that had multiple intracranial targets with d{sub iso} of at least 1 target > 5 cm. A single isocenter VMAT plan was created using a standardized 4-arc technique with 18 Gy per target. Each case was then replanned (1) using 2 to 3 isocenters, (2) including a maximum dose constraint per target, and in the case of 7 to 9 targets, (3) using 3 to 6 arcs. Dose evaluation included brain V{sub 6} {sub Gy} and V{sub 12} {sub Gy}, and conformity index (CI), gradient index (GI), and heterogeneity index (HI) per target. Two isocenters were sufficient to limit d{sub iso} to ≤ 4 cm and ≤ 5 cm for 11/15 and 13/15 cases, respectively; after replanning with 2 to 3 isocenters, d{sub iso} decreased from 5.8 ± 2.8 cm (2.3 14.9) to 2.5 ± 1.4 cm (0 5.2). All dose statistics improved on average, albeit modestly: V{sub 6} {sub Gy} = 6.9 ± 7.1%, V{sub 12} {sub Gy} = 0.9% ± 4.4%, CI = 2.6% ± 4.6%, GI = 0.9% ± 12.7%, and HI = 2.6% ± 5.2%; however, the number of arcs doubled and monitor units increase by nearly 2-fold. A maximum dose constraint had a negative effect on all dose indices, increasing V{sub 12} {sub Gy} by 9.7 ± 6.9%. For ≥ 7 targets, increasing number of arcs to > 3 improved CI, V{sub 12} {sub Gy}, and V{sub 6} {sub Gy}. A single isocenter is likely sufficient for VMAT radiosurgery of multiple intracranial metastases. Optimal treatment plan quality is achieved when no constraint is placed on the maximum target dose; for cases with many targets at least 4 arcs are needed for optimal plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Plan quality comparison between 4-arc and 6-arc noncoplanar volumetric modulated arc stereotactic radiotherapy for the treatment of multiple brain metastases

To compare the plans of 4-arc and 6-arc noncoplanar volumetric modulated arc stereotactic radiotherapy (VMA-SRT) for multiple brain metastases and to investigate the cutoff value for the tumor number and volume for 6-arc rather than 4-arc VMA-SRT. We identified 24 consecutive multiple-target cases (3 to 19 targets in each case) with 189 total targets. We constructed plans using both 4- and 6-arc noncoplanar VMA-SRT. The prescribed dose was 36 Gy/6 fr, and it was delivered to 95% of the planning target volume (PTV). The plans were evaluated for the dose conformity using the Radiation Therapy Oncology Group and Paddick conformity indices (RCI and PCI), fall-off (Paddick gradient index [PGI]), and the normal brain dose. The median (range) RCI, PCI, and PGI was 0.94 (0.92 to 0.99), 0.89 (0.77 to 0.94), and 3.75 (2.24 to 6.54) for the 4-arc plan and 0.94 (0.91 to 0.98), 0.89 (0.76 to 0.94), and 3.65 (2.24 to 6.5) for the 6-arc plan, respectively. The median (range) of the normal brain dose was 910.3 cGy (381.4 to 1268.9) for the 4-arc plan and 898.8 cGy (377 to 1252.9) for the 6-arc plan. The PGI of the 6-arc plan was significantly superior to that of the 4-arc plan (p = 0.0076), and the optimal cutoff values for the tumor number and volume indicative of 6-arc (and not 4-arc) VMA-SRT were cases with ≥ 5 metastases and a PTV of ≥ 12.9 mL, respectively. The PCI values, however, showed no significant difference between the 2 plans. We believe these results will help in considering the use of 6-arc VMA-SRT for multiple brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiplication and Presence of Shielding Material from Time-Correlated Pulse-Height Measurements of Subcritical Plutonium Assemblies

Here, we present the results from the first measurements of the Time-Correlated Pulse-Height (TCPH) distributions from 4.5 kg sphere of α-phase weapons-grade plutonium metal in five configurations: bare, reflected by 1.27 cm and 2.54 cm of tungsten, and 2.54 cm and 7.62 cm of polyethylene. A new method for characterizing source multiplication and shielding configuration is also demonstrated. The method relies on solving for the underlying fission chain timing distribution that drives the spreading of the measured TCPH distribution. We found that a gamma distribution fits the fission chain timing distribution well and that the fit parameters correlate with both multiplication (rate parameter) and shielding material types (shape parameter). The source-to-detector distance was another free parameter that we were able to optimize, and proved to be the most well constrained parameter. MCNPX-PoliMi simulations were used to complement the measurements and help illustrate trends in these parameters and their relation to multiplication and the amount and type of material coupled to the subcritical assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiplicity dependence of ϒ production at forward rapidity in pp collisions at $\sqrt{s}$ = 13 TeV

The measurement of ϒ(1S), ϒ(2S), and ϒ(3S) yields as a function of the charged-particle multiplicity density, d N ch /d η , using the ALICE experiment at the LHC, is reported in pp collisions at √s = 13 TeV. The Υ meson yields are measured at forward rapidity (2.5 < y < 4) in the dimuon decay channel, whereas the charged-particle multiplicity is defined at central rapidity (| η | <1). Both quantities are divided by their average value in minimum bias events to compute the self-normalized quantities. The increase of the self-normalized ϒ(1S), ϒ(2S), and ϒ(3S) yields is found to be compatible with a linear scaling with the self-normalized d N ch /d η , within the uncertainties. The self-normalized yield ratios of excited-to-ground ϒ states are compatible with unity within uncertainties. Similarly, the measured double ratio of the self-normalized ϒ(1S) to the self-normalized J/ ψ yields, both measured at forward rapidity, is compatible with unity for self-normalized charged-particle multiplicities beyond one. The measurements are compared with theoretical predictions incorporating initial or final state effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗