Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

High Reynolds number tests of the CAST 10-2/DOA 2 airfoil in the Langley 0.3-meter transonic cryogenic tunnel, phase 1

A wind tunnel investigation of an advanced technology airfoil, the CAST 10-2/DOA 2, was conducted in the Langley 0.3 meter Transonic Cryogenic Tunnel (0.3 m TCT). This was the first of a series of tests conducted in a cooperative National Aeronautics and Space Administration (NASA) and the Deutsche Forschungs- und Versuchsanstalt fur Luft- und Raumfahrt e. V. (DFVLR) airfoil research program. Test temperature was varied from 280 K to 100 K to pressures from slightly above 1 to 5.8 atmospheres. Mach number was varied from 0.60 to 0.80, and the Reynolds number (based on airfoil chord) was varied from 4 x 10 to the 8th power to 45 x 10 to the 6th power. This report presents the experimental aerodynamic data obtained for the airfoil and includes descriptions of the airfoil model, the 0.3 m TCT, the test instrumentation, and the testing procedures.

Dress, D. A.↗

The JPL 1.5-meter Clear Aperture Antenna with 84.5 Percent Efficiency

The theoretical and experimental study of a 1.5-meter offset dual shaped reflector at 31.4 GHz is detailed. An efficiency of 84.5 percent, a likely new record for reflector antennas, was ascertained through careful measurements. For larger low noise reflector systems, a 2- to 3-dB improvement in G/T performance over the state of the art ultra low noise ground stations and 90 percent or better aperture efficiency now appear feasible.

Cha, A. G.↗

Application of a laser interferometer skin-friction meter in complex flows

The application of a nonintrusive laser-interferometer skin-friction meter, which measures skin friction with a remotely located laser interferometer that monitors the thickness change of a thin oil film, is extended both experimentally and theoretically to several complex wind-tunnel flows. These include two-dimensional seperated and reattached subsonic flows with large pressure and shear gradients, and two and three-dimensional supersonic flows at high Reynolds number, which include variable wall temperatures and cross-flows. In addition, it is found that the instrument can provide an accurate location of the mean reattachment length for separated flows. Results show that levels up to 120 N/sq m, or 40 times higher than previous tests, can be obtained, despite encountering some limits to the method for very high skin-friction levels. It is concluded that these results establish the utility of this instrument for measuring skin friction in a wide variety of flows of interest in aerodynamic testing.

Monson, D. J.↗

Recent applications of a laser velocimeter in the Langley 4by 7-meter Wind Tunnel

A long focal length laser velocimeter (LV) has become a production measurement tool in the Langley 4- by 7-Meter Tunnel. Two recent applications of the LV include flowfield measurements: (1) in the wake of a helicopter, and (2) around the wing of an aspect-ratio (AR) 7 wing-body model. A discussion of these two applications is provided along with a description of the flowfields in terms of the mean velocities and turbulence intensities.

Sellers, W. L., III↗

Reynolds number tests of an NPL 9510 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

An investigation of the NPL 9510 airfoil was conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel over the following ranges of test conditions: Mach number of 0.35 to 0.82, total temperature of 94 K to 300 K, total pressure of 1.20 to 5.81 atm, Reynolds number based on airfoil chord of 1.34 x 10 to the 6th power to 48.23 x 10 to the 6th power, and angle of attack of 0 deg to 6 deg. The drag creep previously reported by the British National Physics Laboratory at low Reynolds numbers was also found to be present at high Reynolds numbers; the section drag coefficient continued to decrease even at the highest Reynolds number tested. Tests made close to free-stream saturation did not produce altered aerodynamic coefficients due to condensation effects.

Jenkins, R. V.↗

Ride quality meter

A ride quality meter is disclosed that automatically transforms vibration and noise measurements into a single number index of passenger discomfort. The noise measurements are converted into a noise discomfort value. The vibrations are converted into single axis discomfort values which are then converted into a combined axis discomfort value. The combined axis discomfort value is corrected for time duration and then summed with the noise discomfort value to obtain a total discomfort value.

Leatherwood, J. D.↗

Tabulation of data from tests of an NPL 9510 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

The tabulated data from tests of a six inch chord NPL 9510 airfoil in the Langley 0.3-Meter Transonic Cryogenic Tunnel. The tests were performed over the following range of conditions: Mach numbers of 0.35 to 0.82, total temperature of 94 K to 300 K, total pressure of 1.20 to 5.81 atm, Reynolds number based on chord of 1.34 x 10 to the 6th to 48.23 x 10 to the 6th, and angle of attack of 0 deg to 6 deg. The NPL 9510 airfoil was observed to have decreasing drag coefficient up to the highest test Reynolds number.

Jenkins, R. V.↗

Flow improvements in the circuit of the Langley 4- by 7-meter tunnel

In order to identify the most promising means for improving the flow in the Langley 4- by 7-Meter Tunnel, detailed surveys of the mean velocity profiles were measured in both the horizontal and vertical planes of symmetry at specific locations throughout the tunnel circuit. These data were obtained at test-section dynamic pressures of 1.53, 2.78, and 4.79 kPa (3 2, 58, and 100 psf, respectively) for tunnel operation in both the closed and open test-section configurations. In the base-line tunnel-flow surveys, the flow patterns near the end of the test section indicate a uniform mean velocity distribution. Downstream of the test section, unsymmetrical flow patterns result in low velocities along the inner walls and in flow separation along the inner wall of the diffuser upstream of the drive fan and along the outer wall of the large diffuser downstream of the drive fan. In order to correct these unsymmetrical flow patterns, a set of trailing-edge flaps attached to the five flow-control vanes located just downstream of the first corner were installed. These flaps were very successful in making the tunnel flow more symmetrical and in eliminating the regions of separation in the diffusers upstream and downstream of the drive fan.

Zachary T Applin↗

Status of advanced airfoil tests in the Langley 0.3-meter transonic cryogenic tunnel

A joint NASA/U.S. industry program to test advanced technology airfoils in the Langley 0.3-meter Transonic Tunnel (TCT) was formulated under the Langley ACEE Project Office. The objectives include providing U.S. industry an opportunity to compare their most advanced airfoils to the latest NASA designs by means of high Reynolds number tests in the same facility. At the same time, industry would again experience in the design and construction of cryogenic test techniques. The status and details of the test program are presented. Typical aerodynamic results obtained, to date, are presented at chord Reynolds number up to 45 x 10(6) and are compared to results from other facilities and theory. Details of a joint agreement between NASA and the Deutsche Forschungs- und Versuchsantalt fur Luft- and Raumfahrt e.V. (DFVLR) for tests of two airfoils are also included. Results of these tests will be made available as soon as practical.

Ladson, C. L.↗

High Reynolds number tests of a Boeing BAC I airfoil in the Langley 0.3-meter transonic cryogenic tunnel

A wind tunnel investigation of an advanced-technology airfoil was conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (TCT). This investigation represents the first in a series of NASA/U.X. industry two dimensional airfoil studies to be completed in the Advanced Technology Airfoil Test program. Test temperature was varied from ambient to about 100 K at pressures ranging from about 1.2 to 6.0 atm. Mach number was varied from about 0.40 to 0.80. These variables provided a Reynolds number (based on airfoil chord) range from about .0000044 to .00005. This investigation was specifically designed to: (1) test a Boeing advanced airfoil from low to flight-equivalent Reynolds numbers; (2) provide the industry participant (Boeing) with experience in cryogenic wind-tunnel model design and testing techniques; and (3) demonstrate the suitability of the 0.3-m TCT as an airfoil test facility. All the objectives of the cooperative test were met. Data are included which demonstrate the effects of fixed transition, Mach number, and Reynolds number on the aerodynamic characteristics of the airfoil. Also included are remarks on the model design, the model structural integrity, and the overall test experience.

Johnson, W. G., Jr.↗

High Reynolds number tests of the cast 10-2/DOA 2 airfoil in the Langley 0.3-meter transonic cryogenic tunnel, phase 2

Wind tunnel tests of an advanced technology airfoil, the CAST 10-2/DOA 2, were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). This was the third of a series of tests conducted in a cooperative airfoil research program between the National Aeronautics and Space Administration and the Deutsche Forschungsund Versuchsanstalt fur Luft- und Raumfahrt e. V. For these tests, temperature was varied from 270 K to 110 K at pressures from 1.5 to 5.75 atmospheres. Mach number was varied from 0.60 to 0.80, and the Reynolds number (based on airfoil chord) was varied from 2 to 20 million. The aerodynamic data for the 7.62 cm chord airfoil model used in these tests is presented without analysis. Descriptions of the 0.3-m TCT, the airfoil model, the test instrumentation, and the testing procedures are included.

Dress, D. A.↗

Data from tests of a R4 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

Aerodynamic data for the DFVLR R4 airfoil are presented in both graphic and tabular form. The R4 was tested in the Langley 0.3-Meter Transonic Cryogenic Tunnel (TCT) at Mach number from 0.60 to 0.78 at angles of attack from -2.0 to 8.0 degrees. The airfoil was tested at Reynolds numbers of 4, 6, 10, 15, 30, and 40 million based on the 152.32 mm chord.

Jenkins, R. V.↗

Development of a 611 MHz feed for a 9-meter reflector

A 2 by 2 array of fan dipoles was designed as a feed for an existing 9.14 meter diameter reflector. Baffles (conducting fences) were utilized to reduce mutual coupling between dipoles and to improve the feed radiation pattern in the H plane. Significant strut scattering effects are noted in the secondary patterns of the reflector antenna.

Bailey, M. C.↗

Flow improvements in the NASA Langley 4- by 7-meter tunnel circuit

The mean velocity profiles in both the horizontal and vertical planes of symmetry at specific locations throughout the tunnel circuit to identify the most promising means for improving the flow in the 4 by 7 meter wind tunnel were measured. In the base line tunnel flow surveys, the flow patterns near the end of the test section indicate a uniform mean velocity distribution. Downstream of the test section, unsymmetrical flow patterns result in low velocities along the inner walls and in flow separation along the inner wall of the diffuser upstream of the drive fan and along the outer wall of the large diffuser downstream of the drive fan. A set of trailing-edge flaps attached to the five flow-control vanes located just downstream of the first corner were installed. These flaps are successful in making the tunnel flow more symmetrical and in eliminating the regions of separation in the diffusers upstream and downstream of the drive fan. Previously announced in STAR as N84-15117

Applin, Z. T.↗

Evaluation of the Langley 4- by 7-meter tunnel for propeller noise measurements

An experimental and theoretical evaluation of the Langley 4- by 7- Meter Tunnel was conducted to determine its suitability for obtaining propeller noise data. The tunnel circuit and open test section are described. An experimental evaluation is performed using microphones placed in and on the tunnel floor. The reflection characteristics and background noise are determined. The predicted source (propeller) near-field/far-field boundary is given using a first-principles method. The effect of the tunnel-floor boundry layer on the noise from the propeller is also predicted. A propeller test stand used for part of his evaluation is also described. The measured propeller performance characteristics are compared with those obtained at a larger scale, and the effect of the test-section configuration on the propeller performance is examined. Finally, propeller noise measurements were obtained on an eight-bladed SR-2 propeller operating at angles of attack -8 deg, 0 deg, and 4.6 deg to give an indication of attainable signal-to-noise ratios.

Block, P. J. W.↗

Description of the insulation system for the Langley 0.3-Meter Transonic Cryogenic Tunnel

The thermal insulation system of the Langley 0.3 Meter Transonic Cryogenic Tunnel is described. The insulation system is designed to operate from room temperature down to about 77.4 K, the temperature of liquid nitrogen at 1 atmosphere. A detailed description is given of the primary insulation sytem consists of glass fiber mats, a three part vapor barrier, and a dry positive pressure purge system. Also described are several secondary insulation systems required for the test section, actuators, and tunnel supports. An appendix briefly describes the original insulation system which is considered inferior to the one presently in place. The time required for opening and closing portions of the insulation system for modification or repair to the tunnel has been reduced, typically, from a few days for the original thermal insulating system to a few hours for the present system.

Lawing, P. L.↗