NASA NTRS1983
In order to identify the most promising means for improving the flow in the Langley 4- by 7-Meter Tunnel, detailed surveys of the mean velocity profiles were measured in both the horizontal and vertical planes of symmetry at specific locations throughout the tunnel circuit. These data were obtained at test-section dynamic pressures of 1.53, 2.78, and 4.79 kPa (3 2, 58, and 100 psf, respectively) for tunnel operation in both the closed and open test-section configurations. In the base-line tunnel-flow surveys, the flow patterns near the end of the test section indicate a uniform mean velocity distribution. Downstream of the test section, unsymmetrical flow patterns result in low velocities along the inner walls and in flow separation along the inner wall of the diffuser upstream of the drive fan and along the outer wall of the large diffuser downstream of the drive fan. In order to correct these unsymmetrical flow patterns, a set of trailing-edge flaps attached to the five flow-control vanes located just downstream of the first corner were installed. These flaps were very successful in making the tunnel flow more symmetrical and in eliminating the regions of separation in the diffusers upstream and downstream of the drive fan.