Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “materials forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Fabrication of a 238Pu target

Precision neutron-induced reaction data are important for modeling the network of isotope production and destruction within a given diagnostic chain. This network modeling has many applications such as the design of advanced fuel cycle for reactors and the interpretation of radiochemical data related to the stockpile stewardship and nuclear forensics projects. Our current funded effort is to improve the neutron-induced reaction data on the short-lived actinides and the specific goal is to improve the neutron capture data on {sup 238}Pu with a half-life of 87.7 years. In this report, the fabrication of a {sup 238}Pu target for the proposed measurement using the DANCE array at LANL is described. The {sup 238}Pu target was fabricated from a sample enriched to 99.35%, acquired from ORNL. A total of 395 {micro}g was electroplated onto both sides of a 3 {micro}m thick Ti foil using a custom-made plating cell, shown in Fig 1. The target-material loaded Ti foil is sandwiched between two double-side aluminized mylar foils with a thickness of 1.4 {micro}m. The mylar foil is glued to a polyimide ring. This arrangement is shown partially in Fig. 2. The assembled target is then inserted into an aluminum container with a wall thickness of 0.76 mm, shown in Fig. 3. A derlin ring is used to keep the target assembly in place. The ends of this cylindrical container are vacuum-sealed by two covers with thin Kapton foils as windows for the beam entrance and exit. Shown in Fig. 4 is details of the arrangement. This target is used for phase I of the proposed measurement on {sup 238}Pu scheduled for Nov 2010 together with the DANCE array to address the safety issues raised by LANL. Shown in Fig. 5 is the preliminary results on the yield spectrum as a function of neutron incident energy with a gate on the total {gamma}-ray energy of equivalent Q value. Since no fission PPAC is employed, the distinction between the capture and fission events cannot be made, which is important for the higher neutron incident energy. However, it indicates that a cross section of less than one barn can be measured. The second phase of this experiment will be carried out in 2011 by assembling a PPAC with the {sup 238}Pu target to extend the measurement to higher neutron incident energies by distinguishing the capture from fission events. The fission cross section becomes dominant for neutron incident energies above 30 keV. This PPAC was developed in FY2010 under the NA22 funding and performed very well for the {sup 239}Pu and {sup 241}Pu measurements. A new {sup 238}Pu target will be fabricated for the phase II measurement using the same electroplating technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermometry based on phonon confinement effect in nanoparticles

Raman spectra of TiO{sub 2} nanoparticles (NPs) have a very strong finite-size dependency due to the phonon confinement effect. This provides a convenient way to characterize NPs size by simply using Raman spectroscopy. Together with fast grain growth kinetics and high stability under high temperature and pressure, these NPs have the potential to forensically retain the complete thermal history (temperature and time) of an event that they went through. Here, we demonstrate that both temperature and time can be determined simultaneously by using these thermosensors in the range of 400-700 deg. C and 5-60 s, assuming that the temperature is constant (a step-function approximation to a thermal spike) during a thermal event.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probing the hydrolytic degradation of UF 4 in humid air

This manuscript describes the chemical transformations that occur during hydrolysis of uranium tetrafluoride (UF 4 ) due to its storage in humid air (85% and 50% relative humidity) at ambient temperatures. This hydrolysis was previously reported to proceed slowly or not at all (depending on the percent relative humidity); however, previous reports relied primarily on X-ray diffraction methods to probe uranium speciation. Here, we employ a battery of physiochemical probing techniques to explore potential hydrolysis, including Raman spectroscopy, powder X-ray diffraction, 19 F nuclear magnetic resonance spectroscopy, scanning electron microscopy, and focused ion beam microscopy with energy-dispersive X-ray spectroscopy. Of these, only Raman spectroscopy proved to be particularly useful at observing chemical changes to UF 4 . It was found that anhydrous UF 4 slightly oxidizes over the course of thirteen days to Schoepite-like uranium complexes and possibly UO 3 . In contrast, UF 4 exposed to 50% relative humidity slightly decomposes into UO 2 F 2 , Schoepite-like uranium complexes, and possibly a high order uranium oxide that eluded chemical assignment (U x O y ). Despite the rich chemical speciation observed in our Raman spectroscopy measurements, X-ray diffraction and 19 F NMR measurements on the same material showed no changes. Microscopy measurements suggest that the observed reactions between UF 4 and water occur primarily on the surface of UF 4 particulates via a method that is visually similar to surface corrosion of metals. Therefore, we postulate that NMR spectroscopy and X-ray diffraction, which are well-suited for bulk analysis, are less suited than Raman spectroscopy to observe the surface-based reactions that occur to UF 4 when exposed to humid air. Considering the importance of UF 4 in the production of nuclear fuel and weapons, the results presented herein are widely applicable to numerous nuclear science fields where uranium detection and speciation in humid environments is of value, including nuclear nonproliferation and nuclear forensics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A system for the measurement of delayed neutrons and gammas from special nuclear materials

The delayed neutron counting (DNC) system at the Royal Military College of Canada has been upgraded to accommodate concurrent delayed neutron and gamma measurements. This delayed neutron and gamma counting (DNGC) system uses a SLOWPOKE-2 reactor to irradiate fissile materials before their transfer to a counting arrangement consisting of six ³He and one HPGe detector. The application of this system is demonstrated in an example where delayed neutron and gamma emissions are used in complement to examine ²³³U content and determine fissile mass with an average relative error and accuracy of -2.2 and 1.5 %, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of Accelerator Applications for Security and Defense

Particle accelerators play a key role in a broad set of defense and security applications including war-fighter and asset protection, cargo inspection, nonproliferation, materials characterization and stockpile stewardship. Accelerators can replace the high activity radioactive sources that pose a security threat for developing a radiological dispersal device and be used to produce isotopes for medical, industrial, and re-search purposes. Lastly, we present an overview of current and emerging accelerator technologies relevant to addressing the needs of defense and security.

43 PARTICLE ACCELERATORS↗

Sensitivities and Uncertainties Related to Numerics and Building Features in Urban Modeling

Oak Ridge National Laboratory (ORNL) has been engaged in the development and testing of a computational system that would use a grid of activation foil detectors to provide postdetonation forensic information from a nuclear device detonation. ORNL has developed a high-performance, three-dimensional (3-D) deterministic radiation transport code called Denovo. Denovo solves the multigroup discrete ordinates (SN) equations and can output 3-D data in a platform-independent format that can be efficiently analyzed using parallel, high-performance visualization tools. To evaluate the sensitivities and uncertainties associated with the deterministic computational method numerics, a numerical study on the New York City Times Square model was conducted using Denovo. In particular, the sensitivities and uncertainties associated with various components of the calculational method were systematically investigated, including (a) the Legendre polynomial expansion order of the scattering cross sections, (b) the angular quadrature, (c) multigroup energy binning, (d) spatial mesh sizes, (e) the material compositions of the building models, (f) the composition of the foundations upon which the buildings rest (e.g., ground, concrete, or asphalt), and (g) the amount of detail included in the building models. Although Denovo may calculate the idealized model well, there may be uncertainty in the results because of slight departures of the above-named parameters from those used in the idealized calculations. Fluxes and activities at selected locations from perturbed calculations are compared with corresponding values from the idealized or base case to determine the sensitivities associated with specified parameter changes. Results indicate that uncertainties related to numerics can be controlled by using higher fidelity models, but more work is needed to control the uncertainties related to the model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASA Tech Briefs, March 2012

The topics include: 1) Spectral Profiler Probe for In Situ Snow Grain Size and Composition Stratigraphy; 2) Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control; 3) In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer; 4) Physics Mining of Multi-Source Data Sets; 5) Photogrammetry Tool for Forensic Analysis; 6) Connect Global Positioning System RF Module; 7) Simple Cell Balance Circuit; 8) Miniature EVA Software Defined Radio; 9) Remotely Accessible Testbed for Software Defined Radio Development; 10) System-of-Systems Technology-Portfolio-Analysis Tool; 11) VESGEN Software for Mapping and Quantification of Vascular Regulators; 12) Constructing a Database From Multiple 2D Images for Camera Pose Estimation and Robot Localization; 13) Adaption of G-TAG Software for Validating Touch and Go Asteroid Sample Return Design Methodology; 14) 3D Visualization for Phoenix Mars Lander Science Operations; 15) RxGen General Optical Model Prescription Generator; 16) Carbon Nanotube Bonding Strength Enhancement Using Metal Wicking Process; 17) Multi-Layer Far-Infrared Component Technology; 18) Germanium Lift-Off Masks for Thin Metal Film Patterning; 19) Sealing Materials for Use in Vacuum at High Temperatures; 20) Radiation Shielding System Using a Composite of Carbon Nanotubes Loaded With Electropolymers; 21) Nano Sponges for Drug Delivery and Medicinal Applications; 22) Molecular Technique to Understand Deep Microbial Diversity; 23) Methods and Compositions Based on Culturing Microorganisms in Low Sedimental Fluid Shear Conditions; 24) Secure Peer-to-Peer Networks for Scientific Information Sharing; 25) Multiplexer/Demultiplexer Loading Tool (MDMLT); 26) High-Rate Data-Capture for an Airborne Lidar System; 27) Wavefront Sensing Analysis of Grazing Incidence Optical Systems; 28) Foam-on-Tile Damage Model; 29) Instrument Package Manipulation Through the Generation and Use of an Attenuated-Fluent Gas Fold; 30) Multicolor Detectors for Ultrasensitive Long-Wave Imaging Cameras; 31) Lunar Reconnaissance Orbiter (LRO) Command and Data Handling Flight Electronics Subsystem; and 32) Electro-Optic Segment-Segment Sensors for Radio and Optical Telescopes.

Source record↗

Assessment of EPRI’s Tan Delta Approach to Manage Cables in Submerged Environments: Statistical Review of EPRI Data

Research conducted by the Electric Power Research Institute (EPRI) and other research institutions have concluded that water-trees are one of the leading degradation mechanisms that contribute to the loss of dielectric insulation strength in medium-voltage cable insulating materials in wet or submerged environments. The electrochemical reactions are caused by the combined effect of water presence and relatively high electrical stress. Records of cable failures provided by the licensees in response to Generic Letter (GL) 2007-01 (NRC 2007) have called into question the reliability of medium voltage cables in wetted or submerged environments. EPRI’s dissipation factor or Tan Delta testing guidelines and acceptance criteria have been adopted by most nuclear power plant operators as the primary tool for condition monitoring of medium voltage cables in wet or submerged environments. EPRI has been collecting member data since late 2009 to analyze and provide feedback to members, validate the EPRI-developed acceptance criteria guidelines, support analysis of test results, recommend appropriate actions for the "action required" category, and gather candidate cables for EPRI-sponsored forensic research on causes for insulation degradation. EPRI has collected data from 37 nuclear sites, which represent 44 operating units. The test results have been organized by insulation type, such as cross-linked polyethylene (XLPE); butyl rubber; black, pink, and brown ethylene-propylene rubber (EPR); and compact insulation (black and pink EPR)1. The data have been analyzed, and follow-up information was obtained from members for “action required” test results. EPRI has also performed correlations between Tan Delta tests and the information gathered under the EPRI forensic research on medium-voltage cables. In addition, EPRI has developed guidance by cable insulation type on how to systematically analyze Tan Delta test results. The analysis described here reviewed the two primary EPRI reports (EPRI 3002000557 and EPRI 3002005321) as well as two precedent EPRI reports (EPRI 1028262 and EPRI 1021070) that were cited in the primary reports. The principal results and conclusions from the project analyses are provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of ambient polychlorinated biphenyl background conditions in surface waters of the Pajarito Plateau, New Mexico

Abstract This study presents the development of polychlorinated biphenyl (PCB) background threshold values (BTVs) that statistically characterize ambient background conditions for surface waters in undeveloped and developed landscapes of the Pajarito Plateau in the Rio Grande Basin of New Mexico. Between 2009 and 2018, surface water data were collected at 45 locations under a variety of flow conditions and regimes. A total of 163 samples were collected, with roughly 1/3 of samples and locations being in undeveloped areas (n = 53 from 17 locations), and the remainder being in developed areas (n = 110 from 28 locations). While there are areas on the Pajarito Plateau where PCB point sources are known or likely to have contributed to PCBs in soils, PCB BTVs calculated for undeveloped portions of watersheds (upstream of areas where PCB point sources are known or likely to have contributed to PCBs in soils, and therefore not affected by PCB sources within the watershed) are well above New Mexico's human health organism-only (HH-OO) water quality criterion (0.64 ng/L). Background threshold values are even higher in developed areas upstream of managed soil sites, suggesting that in developed areas, both diffuse ambient PCB sources (e.g., atmospheric deposition) and localized urban sources (e.g., building materials, paints, and electrical equipment) contribute to PCBs in those watersheds. These findings indicate that New Mexico's current HH-OO water quality criterion for PCBs cannot practicably be met due to ambient conditions. It is also impracticable to meet the US Environmental Protection Agency (EPA) criterion continuous concentration (CCC) of 14 ng/L in developed background areas, where the BTV is approximately 1.5 times the CCC. Integr Environ Assess Manag 2023;19:1307–1319. © 2022 SETAC

54 ENVIRONMENTAL SCIENCES↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Intrinsic Dosimetry: Elemental Composition Effects on the Thermoluminescence of Commercial Borosilicate Glass

Intrinsic dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering this dose in tandem with the physical characteristics of the radioactive material housed within the container, this method can provide enhanced pathway information for interdicted radioactive samples. Thermoluminescence (TL) dosimetry was used to measure ionizing radiation dose effects on stock borosilicate glass. Differences in TL glow curve shape and intensity were observed for glasses from different geographical origins. The different TL signatures strongly correlated with the concentration of alkaline earth metals and the ratio of sodium to the total amount of alkali metal present in the borosilicate glass.

61 RADIATION PROTECTION AND DOSIMETRY↗

Producing 236 U reference standards for Accelerator Mass Spectrometry at the University of Notre Dame

36 U is a rare isotope of uranium, naturally occurring in ores with an abundance of 236 U/ 238 U$<$ 1 x 10 -9 . The ability to detect it and make isotopic ratio measurements has applications ranging from nuclear forensics and nonproliferation to energy production and environmental protection. Currently, Accelerator Mass Spectrometry (AMS) is the only technique sensitive enough to accurately measure 236 U/ 238 U isotopic ratios as they exist in naturally occurring ores in the range of 236 U/ 238 U = 10 -12 $-$ 10 -9 . Some AMS facilities have demonstrated their capabilities to make these measurements. Historically, the lack of commercially available reference standards covering the range of naturally occurring 236 U/ 238 U abundances has necessitated the use of absolute measurements, notoriously difficult to do using AMS, resulting in increased uncertainties in measurements and a reliance on knowledge of systematic effects. To mitigate these issues, various AMS facilities have sought to develop their own reference standards. Using a reference standard prepared for other forms of mass spectrometry, a series of AMS suitable standards was created through dilution with low-background natural uranium. The techniques used to produce and characterize these materials as well as analysis of them using AMS will be discussed.

236U↗

Initial Benchmarking of the Liquid Sampling-Atmospheric Pressure Glow Discharge-Orbitrap System Against Traditional Atomic Mass Spectrometry Techniques for Nuclear Applications

The integration of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ion source with Orbitrap mass spectrometers has resulted in new opportunities in the field of isotope ratio mass spectrometry. In a field that has been dominated by thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) on quadrupole and scanning-mode sector field analyzer platforms for highly accurate and precise measurements, the LS-APGD-Orbitrap system offers a benchtop instrument capable of meeting the rigorous International Target Values for measurement uncertainty for uranium (U). In order to benchmark the LS-APGD-Orbitrap, a series of U certified reference materials with increasing {sup 235}U isotopic composition were analyzed. By using U samples ranging in enrichment from 1 to 80%, the ability of the system to measure isotope ratios over a wide range is demonstrated. This analysis represents the first time that the LS-APGD-Orbitrap system has been used to analyze highly enriched U samples, allowing for the measurement of each of the U isotopes, including {sup 234}U and {sup 236}U-related species, which had not been achieved previously. Ultimately, the LS-APGD-Orbitrap system was able to measure CRM U-800 (assayed as {sup 235}U / {sup 238}U = 4.265622) as 4.266922, with a combined uncertainty, (u{sub c}), of 0.040%. These results are compared to those obtained using traditional elemental mass spectrometers including TIMS and ICP-MS-based instruments. The effectiveness of the LS-APGD-Orbitrap MS system for measuring U isotopes shows excellent promise in nuclear forensics, safeguards, and other nuclear weapon-based applications. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

US Efforts in Support of Examinations at Fukushima Daiichi – 2016 Evaluations

Although it is clear that the accident signatures from each unit at the Fukushima Daiichi Nuclear Power Station (NPS) [Daiichi] differ, much is not known about the end-state of core materials within these units. Some of this uncertainty can be attributed to a lack of information related to cooling system operation and cooling water injection. There is also uncertainty in our understanding of phenomena affecting: a) in-vessel core damage progression during severe accidents in boiling water reactors (BWRs), and b) accident progression after vessel failure (ex-vessel progression) for BWRs and Pressurized Water Reactors (PWRs). These uncertainties arise due to limited full scale prototypic data. Similar to what occurred after the accident at Three Mile Island Unit 2, these Daiichi units offer the international community a means to reduce such uncertainties by obtaining prototypic data from multiple full-scale BWR severe accidents. Information obtained from Daiichi is required to inform Decontamination and Decommissioning activities, improving the ability of the Tokyo Electric Power Company Holdings (TEPCO) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This document reports recent results from the US Forensics Effort to use information obtained by TEPCO to enhance the safety of existing and future nuclear power plant designs. This Forensics Effort, which is sponsored by the Reactor Safety Technologies Pathway of the Department of Energy Office of Nuclear Energy Light Water Reactor (LWR) Sustainability Program, consists of a group of US experts in LWR safety and plant operations that have identified examination needs and are evaluating TEPCO information from Daiichi that address these needs. Examples presented in this report demonstrate that significant safety insights are being obtained in the areas of component performance, fission product release and transport, debris end-state location, and combustible gas generation and transport. In addition to reducing uncertainties related to severe accident modeling progression, these insights are being used to update guidance for severe accident prevention, mitigation, and emergency planning. Furthermore, reduced uncertainties in modeling the events at Daiichi will improve the realism of reactor safety evaluations and inform future D&D activities by improving the capability for characterizing potential hazards to workers involved with cleanup activities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CSI comes to nuclear security

Viewers of television cop shows like “CSI” or its many imitators are familiar with the idea of how forensics can be used to track down a culprit. If you watch and listen closely, you will notice that the detectives often refer to a national collection of crime scene DNA “fingerprints” held on file in a US federal database called CODIS, which helps to narrow down suspects. For example, after DNA has been picked up from a crime scene, it is entered into the system, and software then scans the voluminous database for a match to known previous offenders. The benefits of such a system in helping to narrow down and identify a list of likely suspects are obvious.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Forensic Analysis of Faulted NSTX-U Inner Poloidal Field Coil

The failure of the NSTX-U PF1A upper coil suspended plasma operations during the project's first operational campaign after commissioning. Initial nondestructive testing and examination of the failed coil was followed by extensive nondestructive radiography. Destructive testing facilitated visual borescope/videoscope inspection through the cooling path, vacuum testing, and electrical testing of every conductor segment. One conductor cooling path visually evidenced a void through the sidewall of the cooling path in a layer-to-layer region. The identified void in the conductor cooling path was not proximal to a braze or joggle. Electrical testing indicated that the voided conductor segment was a member of a group of 14 conductor segments that evidenced low-resistance connectivity. Four braze joints and two lead segments were subjected to 400-lbf/in 2 hydrostatic pressure testing followed by helium leak testing and evidenced that there were no detectable leaks in the tested cooling path segments. The faulted region was proximal to the center of the coil pack and evidenced historical electrical pitting and molten conductor debris. Samples of the epoxy resin insulation system were extracted and analyzed with dynamic mechanical analysis and differential scanning calorimetry techniques. Epoxy resin insulation samples were subjected to immersion testing per ASTM D570. Metallurgical samples were extracted from the coil pack conductors and subjected to hardness testing and grain structure analysis. The base material testing results indicated no abnormalities. In conclusion, the coil incipient failure was determined to most likely have resulted from conductive material located between conductor and insulation layers.

25 ENERGY STORAGE↗

Foundations of Molecular 'Isotomics'

The naturally occurring rare isotopes are versions of common elements, such as hydrogen, carbon and oxygen, that contain a larger than usual number of neutrons in their atomic nuclei and therefore are higher in mass than the common atoms of that element. Isotopes exist for most elements and are found in most natural and synthetic materials, but are uneven in their distribution because chemical and physical processes are isotope-selective (e.g., a chemical reaction may proceed more rapidly for one isotope than for another). For this reason, abundances of isotopes in a material of interest can provide a record, or ‘signature’ of various features of that material’s origin and history. These signatures have been used in the geo, life, chemical and physical sciences in a wide variety of ways over close to 8 decades. However, many such applications struggle to reach unique interpretations of isotopic data because multiple factors combine to control a given sample’s overall isotopic content. That is, the factors controlling isotopic content are too numerous and complex to fully constrain from a simple measurement of a material’s isotope abundances. However, the distribution of isotopes within materials, at molecular scales potentially provides a vastly larger number and diversity of constraints on the chemical and physical processes that comprise a material’s history. The rare isotopes may be concentrated into one atomic position in a molecule relative to another, some proportion of molecules in a sample may contain two or more rare isotopes, and those multiply-isotope-substituted forms of molecules may also have uneven distributions of those isotopes across individual atomic sites. For these reasons, even small, seemingly simple molecules, such as sugars, amino acids or drug compounds, actually exist in a vast number of isotopically unique forms (often millions or more), and each one of those forms is in some sense an independent ‘vote’ on that sample’s history. This project has focused on opening this rich archive of information by enabling the creation of routinely and widely applicable ways of measuring and interpreting isotopic structures of molecules. This work has included the development of core technologies and analytical methods, advancing fundamental understanding of the physical and chemical properties of isotopic versions of molecules, and conducting proof of concept studies of illustrative geochemical, cosmochemical and forensic problems in order to show how these technologies, methods and principles come together to solve problems in new ways. A key to the success of this project was the adaptation of ‘Fourier transform mass spectrometry’ (FTMS) to the task of precisely measuring proportions of the rare, naturally occurring isotopic forms of molecules. FTMS is a highly specialized form of mass spectrometry that traps ions within magnetic or electrostatic cavities and, effectively, ‘listens’ (through registering of subtle electrical signals) to the harmonic signals they make while rapidly orbiting within those cavities. These signals have periods that are a function of their mass and strength (or ‘loudness’) that is proportional to their abundances. Thus, these signals constrain relative amounts of molecules that differ in their mass due to various isotopic substitutions. This technology has been essential to the identification of organic molecules in the life, chemical and environmental sciences for over 4 decades, but generally has lacked the control, stability and precision to meaningfully measure rare isotope forms of molecules. This project’s most fundamental contribution has been to modify FTMS, both in terms of hardware and methods, to enable such measurements. The raw data of molecular isotopic structure is tremendously voluminous and complex, so another important activity of this project has been developing the theoretical and data-science tools needed to interpret the data generated by this new form of isotopic measurement. A particularly challenging part of this task has been predicting molecular isotopic structure, as only through the comparison of measurements with predictions can we make progress on hypothesis driven research questions. We have attacked this this prediction task through a combination of first-principles chemical-physics models of the effects of isotope substitution on molecule properties and data-science models that permit us to generalize that chemical physics to cases that have not yet been studied by detailed chemical physics theory. The proof of concept applications we have pursued over the course of this study include biological reactions of amino acids and other biomolecules, non-biological synthesis of organic molecules in extra-terrestrial settings such as meteorites, petroleum geoscience questions concerning the origin and evolution of natural gas, oil and kerogen compounds, and forensic questions such as the sourcing of chemical weapons. The successes of these applications have laid the groundwork for the next phase of this field’s development, which will include larger scale and more ambitious studies of molecular isotopic structure as a means of diagnosing human diseases, such as cancer, and reconstructing detailed interpretations of the origin and evolution of organic molecules in modern and geological environments.

Cesar, Jaime↗