Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loss reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Thermal analysis of combustion synthesis of FeAlxOy catalysts for dehydrogenation of fossil fuels

The growing demand for hydrogen as a clean energy carrier highlights the need for its alternative production method with reduced CO₂ emissions. Microwave-assisted thermocatalytic dehydrogenation of fossil fuels offers a promising solution for clean hydrogen production, with FeAlxOy nanocomposites acting as efficient catalysts due to their thermal stability, catalytic activity, and microwave-absorption properties. FeAlxOy nanocomposites, fabricated by solution combustion synthesis (SCS), have shown good microwave-absorption and catalytic properties. However, the effects of synthesis parameters such as fuel type and Fe:Al molar ratio on the SCS process and properties of the final material are not well understood. The SCS process involves vaporization of water, thermal decomposition of the mixture components, and oxidation – reduction reactions. In the present work, thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) were utilized to study the SCS mechanism, with a focus on understanding decomposition processes. TGA provided insights into the thermal stability and mass loss profiles of the mixtures, while DSC quantified the heat release and identified reaction onset temperatures. Results demonstrated that the choice of fuel significantly influenced the thermal behavior and properties of FeAlxOy nanocomposites. Glycine-based mixtures exhibited superior thermal stability and complete decomposition in a single step with high heat release compared to citric acid-based mixtures, which required higher synthesis temperatures and experienced slower, two-step decomposition processes. These findings emphasize the effectiveness of glycine-fueled SCS in producing thermally stable and catalytically active FeAlxOy nanocomposites.

Martinez Espinoza, Laura Alejandra↗

In-situ and in-operando analysis of voltage losses using sense wires for proton exchange membrane water electrolyzers

Proton exchange membrane water electrolyzer development requires understanding processes at the materials and interface levels to reach the required performance and lifetime targets for increasing market penetration. To achieve the required progress, it is critical to develop advanced in-situ diagnostics that allow observation of the changes that come with the reduction of catalyst loading combined with long-term intermittent operation. This work presents an internal voltage sensing method that enables observing internal voltage drops in an operating electrolyzer cell. It allows the total cell resistance to be separated into anode, CCM, and cathode resistance. The method is demonstrated by operating cells with different anode porous transport layers (PTLs). The changing properties of the PTLs result in significant variations of the resistances. Enhancing the PTL properties with a protective coating reduces the anode resistance significantly. In addition to these observations, the method enables a real-time monitoring of resistance related values that impact performance in water electrolyzers. Long-term experiments with the method allow us to gain insights into processes that occur during operation such as conditioning or degradation. The internal voltage sensing method presented in this study is a novel technique for diagnosing, analyzing, and optimizing water electrolyzers and other energy conversion devices.

42 ENGINEERING↗

Role of microstructure on flux expulsion of superconducting radio frequency cavities

The trapped residual magnetic flux during the cool-down due to the incomplete Meissner state is a significant source of radio frequency losses in superconducting radio frequency cavities. Here, in this study, we clearly correlate the niobium microstructure in elliptical cavity geometry and flux expulsion behavior. In particular, a traditionally fabricated Nb cavity half-cell from an annealed poly-crystalline Nb sheet after an 800 °C heat treatment leads to a bi-modal microstructure that ties in with flux trapping and inefficient flux expulsion. This non-uniform microstructure is related to varying strain profiles along the cavity shape. A novel approach to prevent this non-uniform microstructure is presented by fabricating a 1.3 GHz single cell Nb cavity with a cold-worked sheet and subsequent heat treatment leading to better flux expulsion after 800 °C/3 h. Microstructural evolution by electron backscattered diffraction-orientation imaging microscopy on cavity cutouts, and flux pinning behavior by dc-magnetization on coupon samples confirms a reduction in flux pinning centers with increased heat treatment temperature. The heat treatment temperature-dependent mechanical properties and thermal conductivity are reported. The significant impact of cold work in this study demonstrates clear evidence for the importance of the microstructure required for high-performance superconducting cavities with reduced losses caused by magnetic flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying nitrogen loss hotspots and mitigation potential for individual fields in the US Corn Belt with a metamodeling approach

The high productivity in the US Corn Belt is largely enabled by the consumption of millions of tons of manufactured fertilizer. Excessive application of nitrogen (N) fertilizer has been pervasive in this region, and the unrecovered N eventually escaped from croplands in forms of nitrous oxide (N 2 O) emission and N leaching. Mitigating these negative impacts is hindered by a lack of practical information on where to focus and how much mitigation potential to expect. At a large scale, process-based crop models are the primary tools for predicting variables required by decision making, but their applications are prohibited by expensive computational and data storage costs. To overcome these challenges, we built a series of metamodels to learn the key mechanisms regarding the carbon (C) and N cycle from a well-validated process-based biogeochemical model, ecosys. The trained metamodel captures over 98% of the variability of the ecosys simulated outputs for 99 randomly selected counties in Iowa, Illinois, and Indiana. To identify hotspots with high mitigation potential, we introduce net societal benefit (NSB) as an indicator for synthesizing the loss in yield and social benefits through emissions and pollutants avoided. Our results show that reducing N fertilizer by 10% leads to 9.8% less N 2 O emissions and 9.6% less N leaching at the cost of 4.9% more SOC depletion and 0.6% yield reduction over the study region. The estimated total annual NSB is $\$395$ M (uncertainty ranges from $\$114$ M to $\$1271$ M), including $\$334$ from social benefits (uncertainty ranges from $\$46$ M to $\$1076$ M), $\$100$ M from saving fertilizer (uncertainty ranges from $\$13$ M to $\$455$ M), and –$\$40$ M due to yield changes (uncertainty ranges from –$\$261$ M to $\$69$ M). For the median scenario, we noted that 20% of the study area accounts for nearly 50% of the NSB, and thus represent hotspot locations for targeted mitigation. Although the uncertainty range suggests that developing such a high-resolution framework is not yet settled and the scenario based estimations are not appropriate to inform the management practices for individual farmers, our efforts shed light on the new generation of analytical tools for life cycle assessment.

54 ENVIRONMENTAL SCIENCES↗

Mesoporous Carbon-Based PGM-Free Catalyst Cathodes

Polymer electrolyte membrane fuel cell (PEMFC) is the most promising energy conversion technology which can be used as the power sources for the electric vehicles with the ultimate cleanness, (no carbon emission from the use of hydrogen), much-improved energy conversion efficiency, longer range, and rapid refueling. However, due to the large amount of platinum group metal (PGM) catalyst used in PEMFC electrodes, the high cost is the bottleneck for the broad commercialization of PEMFCs for transportation. Hence, there is a critical need to develop low-cost, high-performance PGM-free cathode catalysts that can dramatically reduce the cost of the catalyst in the PEMFC by one to two orders of magnitude. However, before PGM-free cathodes become viable, several technical challenges associated with PGM-free cathodes must be addressed, including the insufficient activity and stability of the catalysts as well as the large transport losses from the much thicker catalyst layer in the electrodes.

08 HYDROGEN↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A comprehensive material study of CdSeTe films deposited with differing selenium compositions

The addition of selenium into CdTe to create the ternary alloy CdSeTe has been one of the most impactful advancements to CdTe-based photovoltaics in the last decade. CdSeTe/CdTe bilayer device structures have enabled a gain in short-circuit current due to the narrower bandgap of the alloy, with minimal to no loss in voltage. Intensity of photoluminescence and time-resolved photoluminescence measurements suggest this is due to an increase in carrier lifetime and concomitant greater fraction of radiative vs non-radiative recombination events which allows for a reduction in the voltage deficit. Here, in this work, we study the properties of as-deposited and CdCl 2 -treated CdSeTe films deposited by close-space sublimation under varying conditions from CdSeTe source charges with both 20 and 40 mol% CdSe. We find that the selenium content in the deposited films are substantially reduced from that of the source material. Additionally, deposition temperature, particularly that of the substrate, considerably affects the grain size, crystallinity, and photoluminescence of the material, illustrating the importance of source material selection and process optimization. Finally, we present evidence that the source material, and therefore the properties of the deposited films, change over time as the source material is used.

36 MATERIALS SCIENCE↗

Materials and Approaches for Mitigation of SOFC Cathode Degradation in SOFC Power Systems

Perovskites such as doped lanthanum manganite and cobaltite have been used successfully as a cathode material in SOFC power systems operating between 700-1000°C. The electrodes, however, remain prone to degradation in presence of Cr containing gas atmosphere under systems operating conditions. Cathode in SOFCs is considered as one of the largest contributors of electrochemical performance degradations, leading to significant increase in ohmic and non-ohmic losses as well as interfacial compound formation. These degradations are mostly irreversible due to permanent changes to chemical and morphological alterations in the electrodes, resulting in the blockage of triple phase boundary (TPB) sites and decrease in oxygen reduction reactions (ORR). Fundamental mechanistic understanding has been developed to elucidate the reaction pathways of electrode poisoning in electronically conducting electrodes (LSM) as well as mixed ionic and electronically conducting electrodes (LSCF). The overall goal of this program has been identification and development of cost effective solutions to mitigate electrode degradations under “real world” systems operating conditions. The overall technological innovations and impact from this work are: The research provides an understanding of the degradation mechanism and cost-effective approaches for implementation in SOFC systems; Develop mitigation processes utilizing low cost getters using conventional synthesis and fabrication route; Develop tailored high surface area powders and coatings for high Cr capture capacity under systems operating conditions; >Developed computational models to understand mechanistic behavior; Experimentally measure rate of Cr evaporation from chromia and alumina forming alloys under SOFC operating conditions; Developed conditions to minimize Cr evaporation from balance-of-plant alloys; This innovation will support the development of getter platform to capture both intrinsic and extrinsic impurities present in air; and, Applications under wide operating temperature range (500-900°C) as well for wide high-temperature electrochemical systems (SOFC, SOEC, and OTM). The work has been successfully developed, validated experimentally and implemented. Successful technology transfer of this knowledge with industrial partners has been accomplished and the getters have been independently tested and validated under their systems operating conditions. The innovation will also find application in related high temperature electrochemical systems such as OTM and SOEC for the prevention of Cr assisted performance degradation. The proposed approach for Cr capture can also be applied to oxy-combustion and other advanced combustion techniques for the reduction of Cr vapor in the exhaust gas stream. This fundamental knowledge gained also has led to the path forward for developing advanced getters for capturing more than one contaminant in air.

01 COAL, LIGNITE, AND PEAT↗

Data for Monitoring Fracture Saturation with Internal Transportable Seismic Sources and Twin Neural Networks

Seismic coda-wave analysis is a well-developed method for detecting subtle physical changes in complex media by measuring arrival times in the late-arriving energy from multiply-scattered or reflected waves. However, a challenge arises when multiply-scattered waves are not sufficiently separated in time from the direct arrivals to provide a clear coda wave train. Additional complications for monitoring changes in fracture systems arise when the signals originate from unsynchronized internal sources, such as natural induced seismicity, from acoustic emission, or from transportable intra-fracture sources (chattering dust), that generate uncontrolled signals that vary in arrival time, amplitude and frequency content. Here, we use a twin neural network (also known as a Siamese neural network) for dimensionality reduction to analyze signals from chattering dust to classify the fluid saturation state of a synthetic fracture system. The twin neural network with shared weights generates a low-dimensional representation of the data input by minimizing contrastive loss, serving as the input to a multiclass classifier that accurately classifies whether multiple fractures in a fracture system are fully saturated or partially saturated, or whether a change in saturation has occurred in different fractures in the system. These results show that information buried in unresolved codas from uncontrolled sources can be extracted using machine learning to monitor the evolution of fracture systems caused by physical and chemical processes even when the scattered and direct wave fields overlap.

58 GEOSCIENCES↗

Collapse of neutrino wave functions under Penrose gravitational reduction

Models of spontaneous wave function collapse have been postulated to address the measurement problem in quantum mechanics. Their primary function is to convert coherent quantum superpositions into incoherent ones, with the result that macroscopic objects cannot be placed into widely separated superpositions for observably prolonged times. Many of these processes will also lead to loss of coherence in neutrino oscillations, producing observable signatures in the flavor profile of neutrinos at long travel distances. The majority of studies of neutrino oscillation coherence to date have focused on variants of the continuous state localization model, whereby an effective decoherence strength parameter is used to model the rate of coherence loss with an assumed energy dependence. Another class of collapse models that have been proposed posit connections to the configuration of gravitational field accompanying the mass distribution associated with each wave function that is in the superposition. A particularly interesting and prescriptive model is Penrose’s description of gravitational collapse which proposes a decoherence time τ determined through E g τ ∼ ℏ , where E g is a calculable function of the Newtonian gravitational potential. Here we explore application of the Penrose collapse model to neutrino oscillations, reinterpreting previous experimental limits on neutrino decoherence in terms of this model. We identify effects associated with both spatial collapse and momentum diffusion, finding that the latter is ruled out in data from the IceCube South Pole Neutrino Observatory so long as the neutrino wave packet width at production is σ ν , x ≤ 2 × 10 − 12 m . Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Enhanced stability of Fe-modified CuO-ZnO-ZrO 2 -Al 2 O 3 /HZSM-5 bifunctional catalysts for dimethyl ether synthesis from CO 2 hydrogenation

In this report a series of iron (Fe) modified CuO-ZnO-ZrO 2 -Al 2 O 3 (CZZA) catalysts, with various Fe loadings, were prepared using a co-precipitation method. A bifunctional catalyst, consisting of Fe-modified CZZA and HZSM-5, was studied for dimethyl ether (DME) synthesis via CO 2 hydrogenation. The effects of Fe loading, reaction temperature, reaction pressure, space velocity, and concentrations of precursor for the synthesis of the Fe-modified CZZA catalyst on the catalytic activity of DME synthesis were investigated. Long-term stability tests showed that Fe modification of the CZZA catalyst improved the catalyst stability for DME synthesis via CO 2 hydrogenation. The activity loss, in terms of DME yield, was significantly reduced from 4.2% to 1.4% in a 100 h run of reaction, when the Fe loading amount was 0.5 (molar ratio of Fe to Cu). An analysis of hydrogen temperature programmed reduction revealed that the introduction of Fe improved the reducibility of the catalysts, due to assisted adsorption of H 2 on iron oxide. The good stability of Fe-modified CZZA catalysts in the DME formation was most likely attributed to oxygen spillover that was introduced by the addition of iron oxide. This could have inhibited the oxidation of the Cu surface and enhanced the thermal stability of copper during long-term reactions.

42 ENGINEERING↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research, Development and Demonstration of Advanced Vehicle Technologies in Clean Motor Fuels (CRADA Final Report)

NREL/DOE has been funding research, development, and demonstration (RD&D) projects to facilitate the deployment of alternative fuels into the marketplace in order to achieve three objectives: 1) enhance the reduction of mobile source emissions in California and the U.S.; 2) increase U.S. competitiveness and economic prosperity; and 3) preserve the environment through the reduction of emissions and toxins from the motor vehicle population. The Lewis-Presley Air Quality Management Act requires the South Coast Air Quality Management District to establish a program to encourage participation in projects to increase the utilization of clean-burning fuels. The parties seek to collaborate on a joint RD&D project to perform a field test on a small vehicle fleet operating on Fischer-Tropsch synthetic diesel fuel. Recently the 106th U.S. Congress designated "gas-to-liquid" (GTL) transportation fuels that are produced from domestic products as alternative fuels under the Energy Policy Act of 1992 (EPACT). Niche markets could develop quickly for these fuel products, perhaps especially for the use of Fischer-Tropsch synthetic fuels in centrally fueled vehicle fleets in California. NREL and its project partners from the U.S. Department of Energy and West Virginia University have recently conducted what we believe to be the first-ever controlled tests of Fischer-Tropsch synthetic fuels in heavy vehicles. These tests have shown that Fischer-Tropsch fuels can be substituted in unmodified trucks and buses without any detectable loss in drivability and performance. Compared to a California diesel fuel baseline, neat Shell Fischer-Tropsch fuel emitted about 12% lower NOx and 24% lower particulate matter over a five-mile driving route while maintaining the same fuel economy on an energy equivalent basis. Whereas these exhaust emissions reductions from these previous studies have been impressive, far greater exhaust emissions reductions can be achieved if the vehicles are retrofitted with emissions control technologies that are enabled by Fischer-Tropsch fuels. For this program, a test fleet would be selected and retrofitted with continuously regenerating traps (CRT’s) or diesel particulate filters (DPF's). The University of West Virginia, under a separate subcontract to SCAQMD will have the responsibility to test and measure the emissions from the test fleet of vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

A Hybrid Heavy Duty Diesel Power System for Off-Road Applications—Concept Validation

A multiyear power system R&D program was completed with the objective of developing an off-road hybrid heavy duty diesel engine with front end accessory drive-integrated energy storage. This system was validated to deliver 10.5–25.6% reduction in fuel consumption over current Tier 4 Final-based 18L diesel engines, over various off-road machine application cycles. The power system consisted of a downsized heavy-duty diesel 13L engine containing advanced combustion technologies, capable of elevated peak cylinder pressures and thermal efficiencies, thermal barrier coatings, exhaust waste heat recovery via SuperTurbo™ turbocompounding, and hybrid energy assisting and recovery through both mechanical and electrical systems. Following the concept definition, design, and analysis phases of the program, the final phase focused on building and validating the performance and efficiency in laboratory tests. While aspects of the system such as start/stop and reduced off-road cooling package energy losses were only analytically evaluated, the main 13L concept engine with full hybrid system was successfully built and tested in steady-state and in transient certification and real-world application cycles. Extensive simulations in Caterpillar's DYNASTY™ software environment utilized the validation test data to assess performance more fully and confidently over varied cycles and strategies. An average fuel consumption reduction of 17.9% was realized, and the majority (~13%) of the benefit stemmed from the core concept 13L engine. In conclusion, a total cost of ownership analysis provides context to commercial viability and where adoption focus should be placed.

33 ADVANCED PROPULSION SYSTEMS↗

MXene/graphene oxide nanocomposites for friction and wear reduction of rough steel surfaces

Development of solid lubricant materials that render reliable performance in ambient conditions, are amenable to industrial size and design complexities, and work on engineered surfaces is reported. These coatings are composed of Ti 3 C 2 T x -Graphene Oxide blends, spray-coated onto bearing steel surfaces. The tribological assessment was carried out in ambient environmental conditions and high contact pressures in a ball-on-disc experimental set-up. The evaluation yielded that the use of Ti 3 C 2 T x -Graphene-Oxide coatings led to substantial reduction in friction down to 0.065 (at 1 GPa contact pressure and 100 mm/s) in comparison to the uncoated of single-component-coated surfaces, surpassing the state-of-the-art. The coatings also provided excellent protection against wear loss of the substrate and counter-face. The results were explained based on the observations from Raman spectroscopy, scanning electron microscopy, transmission electron microscopy, and nanoindentation measurements. In operando formation of a dense, hard and stiff, dangling-bond-saturated tribolayer was observed to be the reason for the sustained lubricity even at high test loads and sliding speeds. This report presents the holistic exploration and correlation of structure-property-processing pertaining to the advancement of solid lubrication science.

36 MATERIALS SCIENCE↗

Toward Energy-Efficient HPC: Insights from Power Profiling a Cloud-Resolving Earth System Model

Power is a fundamental constraint as supercomputing advances to exascale. Efficient operation within strict power budgets requires application-aware power management based on a detailed understanding of application-level power behavior. This work analyzes the Energy Exascale Earth System Model (E3SM) atmosphere component, SCREAM, on Perlmutter (NERSC) and Frontier (OLCF). We characterize power variation across inputs, concurrency levels, and power caps, evaluate the energy impact of code optimizations, and attribute energy within the code using a newly developed GPU energy model. Results show that SCREAM’s peak power remains stable during its core execution phase and decreases gradually as concurrency increases. Power capping experiments reveal a performance–energy "sweet spot". On Perlmutter, limiting GPU power to 50% of thermal design power (TDP) achieves up to 15% energy savings with a 7% performance penalty. On Frontier, a 40% TDP cap yields up to 10% energy savings with less than 10% performance loss. Code optimizations reduce SCREAM energy by shortening run time without increasing power. Modeling reveals a critical insight: data movement accounts for approximately 70% of SCREAM’s GPU energy. This fundamentally shifts the optimization focus from FLOPS to data transfer reduction for this class of applications, offering the most impactful strategy for improving energy efficiency. This work establishes a foundation for practical, application-aware power management at exascale.

Zhao, Zhengji [Lawrence Berkeley National Laborato↗

Power Generation and Oxygen Transfer Analyses for Micro Hydro-Turbine Installed in Wastewater Treatment Aeration Tank

This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current’s kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15*), 53.4 cm (21*), and 68.6 cm (27*) were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the standard oxygen transfer efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65–80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.

Energy & Fuels↗

Using spatio-temporal graph neural networks to estimate fleet-wide photovoltaic performance degradation patterns

Accurate estimation of photovoltaic (PV) system performance is crucial for determining its feasibility as a power generation technology and financial asset. PV-based energy solutions offer a viable alternative to traditional energy resources due to their superior Levelized Cost of Energy (LCOE). A significant challenge in assessing the LCOE of PV systems lies in understanding the Performance Loss Rate (PLR) for large fleets of PV systems. Estimating the PLR of PV systems becomes increasingly important in the rapidly growing PV industry. Precise PLR estimation benefits PV users by providing real-time monitoring of PV module performance, while explainable PLR estimation assists PV manufacturers in studying and enhancing the performance of their products. However, traditional PLR estimation methods based on statistical models have notable drawbacks. Firstly, they require user knowledge and decision-making. Secondly, they fail to leverage spatial coherence for fleet-level analysis. Additionally, these methods inherently assume the linearity of degradation, which is not representative of real world degradation. To overcome these challenges, we propose a novel graph deep learning-based decomposition method called the Spatio-Temporal Graph Neural Network for fleet-level PLR estimation (PV-stGNN-PLR). PV-stGNN-PLR decomposes the power timeseries data into aging and fluctuation components, utilizing the aging component to estimate PLR. PV-stGNN-PLR exploits spatial and temporal coherence to derive PLR estimation for all systems in a fleet and imposes flatness and smoothness regularization in loss function to ensure the successful disentanglement between aging and fluctuation. We have evaluated PV-stGNN-PLR on three simulated PV datasets consisting of 100 inverters from 5 sites. Experimental results show that PV-stGNN-PLR obtains a reduction of 33.9% and 35.1% on average in Mean Absolute Percent Error (MAPE) and Euclidean Distance (ED) in PLR degradation pattern estimation compared to the state-of-the-art PLR estimation methods.

14 SOLAR ENERGY↗