Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Navigation Strategies for Primitive Solar System Body Rendezvous and Proximity Operations

A wealth of scientific knowledge regarding the composition and evolution of the solar system can be gained through reconnaissance missions to primitive solar system bodies. This paper presents analysis of a baseline navigation strategy designed to address the unique challenges of primitive body navigation. Linear covariance and Monte Carlo error analysis was performed on a baseline navigation strategy using simulated data from a· design reference mission (DRM). The objective of the DRM is to approach, rendezvous, and maintain a stable orbit about the near-Earth asteroid 4660 Nereus. The outlined navigation strategy and resulting analyses, however, are not necessarily limited to this specific target asteroid as they may he applicable to a diverse range of mission scenarios. The baseline navigation strategy included simulated data from Deep Space Network (DSN) radiometric tracking and optical image processing (OpNav). Results from the linear covariance and Monte Carlo analyses suggest the DRM navigation strategy is sufficient to approach and perform proximity operations in the vicinity of the target asteroid with meter-level accuracy.

Getzandanner, Kenneth M.↗

The Primordial Inflation Explorer (PIXIE) Mission

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from frequencies 30 GHz to 6 THz (I cm to 50 I-tm wavelength). PIXIE uses a polarizing Michelson interferometer with 2.7 K optics to measure the difference spectrum between two orthogonal linear polarizations from two co-aligned beams. Either input can view either the sky or a temperature-controlled absolute reference blackbody calibrator. The multimoded optics and high etendu provide sensitivity comparable to kilo-pixel focal plane arrays, but with greatly expanded frequency coverage while using only 4 detectors total. PIXIE builds on the highly successful COBEIFIRAS design by adding large-area polarization-sensitive detectors whose fully symmetric optics are maintained in thermal equilibrium with the CMB. The highly symmetric nulled design provides redundant rejection of major sources of systematic uncertainty. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much less than 10(exp -3). PIXIE will also return a rich data set constraining physical processes ranging from Big Bang cosmology, reionization, and large-scale structure to the local interstellar medium. Keywords: cosmic microwave background, polarization, FTS, bolometer

Kogut, Alan J.↗

The optical spectrum of R136a - The central object of the 30 Doradus nebula

R136 (HD 38268) is the brightest member of the compact cluster of stars at the center of the 30 Doradus Nebula, a massive H II region in the Large Magellanic Cloud (LMC). The far-ultraviolet luminosity is equivalent to at least 1000 ordinary O type stars. Optically, R136 is an unresolved patch corresponding to a linear extent of about 0.7 pc. Several components are known to be present, of which R136a is the brightest. A quantitative description of the optical spectrum of R136a has not been available in the literature. The present investigation is concerned with the analysis of spectrograms in the visible region. It is found that the optical spectrum of R136a shows broad but rather weak emission lines of ions which are frequently seen in early WN-type stars. The centroid of H-alpha is displaced by approximately 100 km/s redward of the nebular H-alpha emission. The Balmer series is visible, in absorption, up to H11.

Ebbets, D. C.↗

SCARLET I: Mechanization solutions for deployable concentrator optics integrated with rigid array technology

The SCARLET I (Solar Concentrator Army with Refractive Linear Element Technology) solar array wing was designed and built to demonstrate, in flight, the feasibility of integrating deployable concentrator optics within the design envelope of typical rigid array technology. Innovative mechanism designs were used throughout the array, and a full series of qualification tests were successfully performed in anticipation of a flight on the Multiple Experiment Transporter to Earth Orbit and Return (METEOR) spacecraft. Even though the Conestoga launch vehicle was unable to place the spacecraft in orbit, the program effort was successful in achieving the milestones of analytical and design development functional validation, and flight qualification, thus leading to a future flight evaluation for the SCARLET technology.

Wachholz, James J.↗

A Low Mass Translation Mechanism for Planetary FTIR Spectrometry using an Ultrasonic Piezo Linear Motor

One of the key components of a Fourier Transform Infrared Spectrometer (FTIR) is the linear translation stage used to vary the optical path length between the two arms of the interferometer. This translation mechanism must produce extremely constant velocity motion across its entire range of travel to allow the instrument to attain high signal-to-noise ratio and spectral resolving power. A new spectrometer is being developed at the Jet Propulsion Laboratory under NASA s Planetary Instrument Definition and Development Program (PIDDP). The goal of this project is to build upon existing spaceborne FTIR spectrometer technology to produce a new instrument prototype that has drastically superior spectral resolution and substantially lower mass, making it feasible for planetary exploration. In order to achieve these goals, Alliance Spacesystems, Inc. (ASI) has developed a linear translation mechanism using a novel ultrasonic piezo linear motor in conjunction with a fully kinematic, fault tolerant linear rail system. The piezo motor provides extremely smooth motion, is inherently redundant, and is capable of producing unlimited travel. The kinematic rail uses spherical Vespel(R). rollers and bushings, which eliminates the need for wet lubrication, while providing a fault tolerant platform for smooth linear motion that will not bind under misalignment or structural deformation. This system can produce velocities from 10 - 100 mm/s with less than 1% velocity error over the entire 100-mm length of travel for a total mechanism mass of less than 850 grams. This system has performed over half a million strokes under vacuum without excessive wear or degradation in performance. This paper covers the design, development, and testing of this linear translation mechanism as part of the Planetary Atmosphere Occultation Spectrometer (PAOS) instrument prototype development program.

Heverly, Matthew↗

The eccentric Saturnian ringlets at 1.29 R(s) and 1.45 R(s)

The shapes and kinematics of the Titan and Maxwell ringlets of Saturn's C ring are studied. The ringlets are narrow and eccentric, with mean widths of about 25 km for Titan and abut 64 km for Maxwell, and with eccentricities of order 10 to the -4th. They have sharp edges on a scale of about 1 km, normal optical depths of roughly 0.5-2.0, normal optical depth of the surrounding region, and positive linear width-radius relations. The Titan ringlet is the only feature whose dynamics appears to be completely determined by an external satellite; the kinematics of the Maxwell ringlet are determined solely by Saturn's nonspherical gravity field. The comparatively large measured optical depths and large inferred mass extinction coefficients for the ringlets suggest an environment and particle size distribution different from the remainder of the C ring and presumably caused by the mechanism responsible for ring confinement.

Porco, C.↗

Short GRB Prompt and Afterglow Correlations

The Swift data set on short GRBs has now grown large enough to study correlations of key parameters. The goal is to compare long and short bursts to better understand similarities and differences in the burst origins. In this study we consider the both prompt and afterglow fluxes. It is found that the optical, X-ray and gamma-ray emissions are linearly correlated - stronger bursts tend to have brighter afterglows, and bursts with brighter X-ray afterglow tend to have brighter optical afterglow. Both the prompt and afterglow fluxes are, on average, lower for short bursts than for long. Although there are short GRBs with undetected optical emission, there is no evidence for "dark" short bursts with anomalously low opt/X ratios. The weakest short bursts have a low X-ray/gamma-ray ratio.

Gehrels, Neil↗

Linearized T-Matrix and Mie Scattering Computations

We present a new linearization of T-Matrix and Mie computations for light scattering by non-spherical and spherical particles, respectively. In addition to the usual extinction and scattering cross-sections and the scattering matrix outputs, the linearized models will generate analytical derivatives of these optical properties with respect to the real and imaginary parts of the particle refractive index, and (for non-spherical scatterers) with respect to the ''shape'' parameter (the spheroid aspect ratio, cylinder diameter/height ratio, Chebyshev particle deformation factor). These derivatives are based on the essential linearity of Maxwell's theory. Analytical derivatives are also available for polydisperse particle size distribution parameters such as the mode radius. The T-matrix formulation is based on the NASA Goddard Institute for Space Studies FORTRAN 77 code developed in the 1990s. The linearized scattering codes presented here are in FORTRAN 90 and will be made publicly available.

Analytic linearization↗

Digital Architecture for a Trace Gas Sensor Platform

A digital architecture has been implemented for a trace gas sensor platform, as a companion to standard analog control electronics, which accommodates optical absorption whose fractional absorbance equivalent would result in excess error if assumed to be linear. In cases where the absorption (1-transmission) is not equivalent to the fractional absorbance within a few percent error, it is necessary to accommodate the actual measured absorption while reporting the measured concentration of a target analyte with reasonable accuracy. This requires incorporation of programmable intelligence into the sensor platform so that flexible interpretation of the acquired data may be accomplished. Several different digital component architectures were tested and implemented. Commercial off-the-shelf digital electronics including data acquisition cards (DAQs), complex programmable logic devices (CPLDs), field-programmable gate arrays (FPGAs), and microcontrollers have been used to achieve the desired outcome. The most completely integrated architecture achieved during the project used the CPLD along with a microcontroller. The CPLD provides the initial digital demodulation of the raw sensor signal, and then communicates over a parallel communications interface with a microcontroller. The microcontroller analyzes the digital signal from the CPLD, and applies a non-linear correction obtained through extensive data analysis at the various relevant EVA operating pressures. The microcontroller then presents the quantitatively accurate carbon dioxide partial pressure regardless of optical density. This technique could extend the linear dynamic range of typical absorption spectrometers, particularly those whose low end noise equivalent absorbance is below one-part-in-100,000. In the EVA application, it allows introduction of a path-length-enhancing architecture whose optical interference effects are well understood and quantified without sacrificing the dynamic range that allows quantitative detection at the higher carbon dioxide partial pressures. The digital components are compact and allow reasonably complete integration with separately developed analog control electronics without sacrificing size, mass, or power draw.

Gonzales, Paula↗

Improved optical performance near the butt regions of multichip focal planes

A technique for improving the optical characteristics at the butted edges of linear-multichip focal-plane imaging arrays is presented. It is shown that the air gap between butted imaging chips causes significant crosstalk. By filling the gap with a material that has an index of refraction more closely matched to that of the substrate, it is possible to reduce the optical crosstalk significantly.

Strong, R. T.↗

A Comparison of Potential IM-CW Lidar Modulation Techniques for ASCENDS CO2 Column Measurements From Space

Global atmospheric carbon dioxide (CO2) measurements through the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) Decadal Survey recommended space mission are critical for improving our understanding of CO2 sources and sinks. IM-CW (Intensity Modulated Continuous Wave) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS science requirements. In previous laboratory and flight experiments we have successfully used linear swept frequency modulation to discriminate surface lidar returns from intermediate aerosol and cloud contamination. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate clouds, which is a requirement for the inversion of the CO2 column-mixing ratio from the instrument optical depth measurements, has been demonstrated with the linear swept frequency modulation technique. We are concurrently investigating advanced techniques to help improve the auto-correlation properties of the transmitted waveform implemented through physical hardware to make cloud rejection more robust in special restricted scenarios. Several different carrier based modulation techniques are compared including orthogonal linear swept, orthogonal non-linear swept, and Binary Phase Shift Keying (BPSK). Techniques are investigated that reduce or eliminate sidelobes. These techniques have excellent auto-correlation properties while possessing a finite bandwidth (by way of a new cyclic digital filter), which will reduce bias error in the presence of multiple scatterers. Our analyses show that the studied modulation techniques can increase the accuracy of CO2 column measurements from space. A comparison of various properties such as signal to noise ratio (SNR) and time-bandwidth product are discussed.

Campbell, Joel F.↗

Evaluation of Wing Load Calibration and Sensing Methods Using Conventional Strain Gages and a Fiber Optic Sensing System Installed on a Straight Tapered Wing

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into structural wing loads during flight. An investigation was undertaken to research new wing instrumentation and load sensing techniques for measuring accurate in-flight spanwise load distributions on wing structures. A straight tapered wing was instrumented with both conventional foil strain gages at five spanwise wing stations and fiber optic strain sensors at every half inch along the entire wing span. Thirty-nine unique load cases were applied to the wing lower surface using hydraulic actuators to obtain various shear, bending moment, and torque load distributions on the wing. This paper will highlight three load calibration approaches. Conventional linear regression calibration methods were applied to foil strain gages providing a single wing station vertical shear, bending moment, and torque load. Linear regression methods were applied to a fiber optic sensing system to provide bending moment and torque spanwise load distributions. A load sensing scheme using strain derived wing shape information derived from a single load case provided vertical shear and bending moment spanwise load distribution information. Aspects of the three different approaches will be compared and contrasted to inform the reader of the benefits or disadvantages of each. Instrument installation, sensor characteristics, test execution aspects, and recommended calibration techniques will be discussed.

structural mechanics↗

AGNet: weighing black holes with deep learning

Supermassive black holes (SMBHs) are commonly found at the centres of most massive galaxies. Measuring SMBH mass is crucial for understanding the origin and evolution of SMBHs. Traditional approaches, on the other hand, necessitate the collection of spectroscopic data, which is costly. We present an algorithm that weighs SMBHs using quasar light time series information, including colours, multiband magnitudes, and the variability of the light curves, circumventing the need for expensive spectra. We train, validate, and test neural networks that directly learn from the Sloan Digital Sky Survey (SDSS) Stripe 82 light curves for a sample of 38 939 spectroscopically confirmed quasars to map out the non-linear encoding between SMBH mass and multiband optical light curves. We find a 1σ scatter of 0.37 dex between the predicted SMBH mass and the fiducial virial mass estimate based on SDSS single-epoch spectra, which is comparable to the systematic uncertainty in the virial mass estimate. Our results have direct implications for more efficient applications with future observations from the Vera C. Rubin Observatory. Our code, AGNet, is publicly available at https://github.com/snehjp2/AGNet.

79 ASTRONOMY AND ASTROPHYSICS↗

Remote probing of the optical strength of atmospheric turbulence and of wind velocity

A procedure for determining the optical strength of turbulence of the atmosphere and the wind velocity at various altitudes by measuring the spatial and temporal covariance of scintillation is developed. Emphasis is placed on the development of the formal relationships that have to be inverted to obtain the desired results. For determination of optical strength of turbulence, it is a linear integral equation that is developed. However, for determination of remote wind velocity, a nonlinear integral equation is obtained. A computer approach for solving each of the equations is suggested. The configuration and performance requirements of the measurement apparatus are discussed.

Fried, D. L.↗

Phase matching in second-harmonic generation using artificial periodic structures.

The use of artificial periodic structures, consisting of spatial modulations of the linear and nonlinear susceptibilities of a nonlinear optical medium, to achieve phase matching in second-harmonic generation is analyzed. Dispersion relations and approximate formulas for the second-harmonic fields generated under various conditions are obtained and used to evaluate the experimental situation.

Tang, C. L.↗

Mariner 9 photometric observations of Mars from November 1971 through March 1972

The large quantity of Mariner 9 television pictures taken at phase angles ranging up to twice those accessible from earth has been used to describe integrated photometric properties of Mars. Although frame-to-frame variations emphasize the shortcomings of vidicon cameras when used in a photometric mode, statistical trends have yielded data comparable with earth-based observations. Analysis of atmospheric parameters over a period of changing opacity - November 1971 through March 1972 - has provided time-varying optical depths and light-scattering information. Linear function characterization of the Mars reflectance is clearly discrepant at large incidence or emission angles and at phase angles greater than 40 deg.

Thorpe, T. E.↗

Slow-scan operation of long linear CCD arrays

Linear CCD arrays used singly or in optically butted assemblies permit practical implementation of long line array systems with 6000 or more picture elements per line with readout rates in excess of 5 MHz. Display and tape recording of slow scan imagery with over 1000 picture elements per line also presents unique challenges. This paper discusses performance results and the operation of 1728-element CCD arrays for generation of high resolution slow scan imagery and some approaches for recording and display of the imagery. The implication of dark current and its control are discussed.

Vicars-Harris, M.↗