Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lasers sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Continuum laser absorption spectroscopy of C 2 (a 3 Π u ) in a sublimating cloud of carbon black

A direct optical absorption diagnostic has been developed for rotationally resolved measurements of diatomic carbon (a 3 Π u →d 3 Π g (0,0) and (1,1)) at a repetition rate of 525 kHz and resolution of 7.3 pm over the range of 511.1–514.1 nm. The diagnostic utilizes a high-power pulsed continuum laser light source dispersed in a spectrograph and imaged by a high-speed camera. Measurements have been performed that capture the temporal evolution of C 2 number density and temperature of a cloud of carbon black sublimating in shock heated gas at high temperature and pressure (T = 5500 K, P = 3.7 atm). A simultaneous light absorption measurement of the condensed phase enables comparisons of the gaseous C 2 number density to the condensed phase mass. The continuum laser absorption diagnostic is applied to C 2 in this work but shows promise in being a simple “drop-in” system for absorption spectroscopy in the visible range at rapid repetition rates and high dispersion, filling an important gap for laser diagnostic systems.

Willhardt, Colton Dean [Univ. of Illinois at Urban↗

Traveling wakefield tube: THz source powered by nonrelativistic electron beam

High peak power, tunable, narrowband terahertz emitters are becoming sought after given their portability, efficiency, and ability to be deployed in the field for industrial, medical, and military applications. The use of accelerator systems producing THz frequencies via Cherenkov radiation, generated by passing an electron beam through a slow-wave wakefield structure, is a promising method to meet future THz requirements. To date, efforts have been dedicated to analysis and design of sources utilizing laser seeded bunched electron beam drivers with relativistic energies beyond 5 MeV. Presented here is a wakefield THz generation scheme based on passing a long quasi-dc nonrelativistic beam (200 keV) through a dielectric loaded travelling wave structure. Reduced energy allows for compactness and portability of the accelerator as the size and weight of the dielectric slow wave structure is vanishingly small compared to the accelerator unit. The presented scheme can serve as a tunable high peak power THz source operated between 0.4-1.6 THz and produces power gain by a factor of five with an average efficiency of 6.8%

43 PARTICLE ACCELERATORS↗

Tunable Laser-Plasma Amplifier (Final Report)

Exploration at the laser intensity frontier has always offered new avenues for physics and reaching beyond this frontier is a grand challenge. Present-day petawatt-class lasers provide focused intensities on target of 10 22 W/cm 2 , corresponding to electric fields of 200 TV/m, while laser-plasma amplification opens a route for focused intensities well above 10 23 W/cm 2 . Intensities in this range provide the ability to test quantum electrodynamics in the unexplored low-energy, strong-field regime where signatures for new physics may arise. The behavior of matter under such extraordinary conditions is a rich and fascinating subject, not only in its own right in fundamental plasma physics, but for the many potential applications that promise to enrich the natural sciences in the future, including compact electron-beam, ion-beam particle accelerators, and ultra-bright X-ray sources. Although laser systems are now under construction internationally to access intensities of 10 23 W/cm 2 , the current technologies used appear to be fundamentally limited to these intensities. The realization of intensities beyond 10 23 W/cm 2 using parametric amplification in plasmas promises a breakthrough in high-energy density physics. Parametric amplification using Raman scattering in a plasma could provide the enabling technology for the generation of ultra-high-power laser pulses, but a more complete understanding of the nonlinear optics of plasmas is required. There is a significant gap in well-diagnosed laser-plasma instability studies of nonlinear plasma-wave phenomena, which are critical to understand for future laser-plasma devices. To achieve an efficient laser-plasma amplifier, plasma waves must be driven to large amplitude where significant energy can be rapidly transferred from the pump to the seed over the pulse duration of the seed. Simulations suggest that this nonlinear pump depletion regime can be achieved in the “pi-pulse” amplification regime. While simulations show this optimal regime with efficient amplification, it has remained elusive in experiments and there is a growing consensus within the community that thermal effects and pump beam limitations prevent laser-plasma amplifiers from progressing through the linear regime into the nonlinear pump depletion regime. Previous experiments have been significantly limited by the laser power available at the necessary wavelengths for the seed laser; therefore, the amplification is required to start in the linear regime where it is sensitive to many deleterious effects. The enabling technology (currently unique to plasma-wave amplification in the world) at the University of Rochester is the ability to provide a seed pulse with sufficient power (4 mJ/100 fs seed) to immediately drive nonlinear plasma waves into the pi-pulse regime and to tune its wavelength to optimize the efficiency of energy transfer. This in combination with the state-of-the-art OMEGA heater beams providing multiple kilojoules in a nanosecond to sufficiently heat the plasma make this system distinct from previous studies. These heater beams will provide, for the first time in Raman amplification studies, a homogeneous electron temperature high enough to prevent pump beam propagation issues that have plagued previous experiments. These systems will provide a platform for driving electron-plasma waves into the nonlinear regime where pump depletion and pulse shortening are predicted to lead to high amplification efficiencies (>30%). The Team has made significant progress through prior support from DOE Fusion Energy Sciences [DOE Office of Science Award Number DE-SC0016253 (2016-2022)]. This includes twenty-two peer-reviewed manuscripts, one patent, ten contributed talks presented at international conferences, and research that was highlighted as invited talks at fifteen international conferences. The broader impacts of this research are evident in the support of early career scientists, two Ph.D. theses, four current graduate students, a Masters Project, two undergraduate researchers, and an underrepresented minority student hired through the California Alliance for Minority Participation who now works as a Research Engineer in the group. This research met all of the funded research objectives and the highlights from primary Raman amplification thrust of this work are discussed below and form the foundation for the proposed research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven collisionless shock acceleration of ions from near-critical plasmas

Here, this paper overviews experimental and numerical results on acceleration of narrow energy spread ion beams by an electrostatic collisionless shockwave driven by 1 μm (Omega EP) and 10 μm (UCLA Neptune Laboratory) lasers in near critical density CH and He plasmas, respectively. Shock waves in CH targets produced high-energy ~50 MeV protons (ΔE/E of ≤30%) and 314 MeV C 6+ ions (ΔE/E of ≤10%). Observation of acceleration of both protons and carbon ions to similar velocities is consistent with reflection of particles off the moving potential of a shock front. For shocks driven by CO 2 laser in a gas jet, ~30 MeV peak in He ion spectrum was detected. Particle-in-cell simulations indicate that regardless of the target further control over its density profile is needed for optimization of accelerated ion beams in part of energy spread, yield and maximum kinetic energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Opto-Electronic Correlator for Robotic Vision Automated Pattern Recognition

A compact laser opto-electronic correlator for pattern recognition has been designed, fabricated, and tested. Specifically it is a translation sensitivity adjustable compact optical correlator (TSACOC) utilizing convergent laser beams for the holographic filter. Its properties and performance, including the location of the correlation peak and the effects of lateral and longitudinal displacements for both filters and input images, are systematically analyzed based on the nonparaxial approximation for the reference beam. The theoretical analyses have been verified in experiments. In applying the TSACOC to important practical problems including fingerprint identification, we have found that the tolerance of the system to the input lateral displacement can be conveniently increased by changing a geometric factor of the system. The system can be compactly packaged using the miniature laser diode sources and can be used in space by the National Aeronautics and Space Administration (NASA) and ground commercial applications which include robotic vision, and industrial inspection of automated quality control operations. The personnel of Standard International will work closely with the Jet Propulsion Laboratory (JPL) to transfer the technology to the commercial market. Prototype systems will be fabricated to test the market and perfect the product. Large production will follow after successful results are achieved.

Laser Opto-Electronic↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

A Tunable Resolution Grating Monochromator and the Quest for Transform Limited Pulses

A variable resolution, transform limited monochromator is designed for the Free Electron Laser (FEL) source of LCLS. It provides monochromatic beam in the 250–1500 eV range, delivering the beam on the second floor of the LCLS experimental Hall. One major requirement for this monochromator is to provide, as close as possible, monochromatic transform limited pulses for time-resolved experiments. The theory and the limit of using classical diffraction scheme to monochromatize Soft X-ray beam, while preserving the pulse length, will be presented, together with the optical scheme of this versatile monochromator design.

47 OTHER INSTRUMENTATION↗

Down-to-earth studies of carbon clusters

Recent advances in supersonic beam experiments with laser-vaporization sources of clusters have provided some interesting new insights into the nature of the small clusters of carbon, and the processes through which carbon condenses. One cluster in particular, C(sub 60), appears to play a central role. It is argued that this cluster takes the shape of a soccerball: a hollow sphere composed of a shell of 60 carbon atoms connected by a lattice of hexagonal and pentagonal rings, in a pattern of overall icosahedral symmetry. Although C(sub 60) appears to be uniquely stable due to its perfect symmetry, all other even-numbered carbon clusters in the 32 to 100+ atom size range seem to favor similar closed spheroidal forms. These species are interpreted as relatively unreactive side products in condensation reactions of carbon vapor involving spiraling graphitic sheets. The prevalence of C(sub 60) in laser-vaporized carbon vapors and sooting flames suggests that it may be formed readily whenever carbon condenses. Such ready formation and extraordinary stability may have substantial astrophysical implications.

Smalley, R. E.↗

Operation modes of the KATRIN experiment Tritium Loop System using 83m Kr

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable 83m Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of 83m Kr allow a direct access to the starting conditions of β-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of 83m Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable 83m Kr-rates, gas densities, and gas compositions inside the WGTS.

47 OTHER INSTRUMENTATION↗

Ambient formaldehyde detection with a laser spectrometer based on difference-frequency generation in PPLN

A laser spectrometer based on difference-frequency generation in periodically poled LiNbO3 (PPLN) has been used to quantify atmospheric formaldehyde with a detection limit of 0.32 parts per billion in a given volume (ppbV) using specifically developed data-processing techniques. With state-of-the-art fiber-coupled diode-laser pump sources at 1083 nm and 1561 nm, difference-frequency radiation has been generated in the 3.53-micrometers (2832-cm-1) spectral region. Formaldehyde in ambient air in the 1- to 10-ppb V range has been detected continuously for nine and five days at two separate field sites in the Greater Houston area operated by the Texas Natural Resource Conservation Commission (TNRCC) and the Houston Regional Monitoring Corporation (HRM). The acquired spectroscopic data are compared with results obtained by a well-established wet-chemical o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) technique.

NASA Discipline Life Sciences Technologies↗

Single-shot X-ray absorption spectroscopy at X-ray free electron lasers

X-ray Absorption Spectroscopy (XAS) is a widely used X-ray diagnostic method for studying electronic and structural properties of matter. At first glance, the relatively narrow bandwidth and the highly fluctuating spectral structure of X-ray Free Electron Lasers (XFEL) sources seem to require accumulation over many shots to achieve high data quality. To date the best approach to implementing XAS at XFEL facilities has been using monochromators to scan the photon energy across the desired spectral range. While this is possible for easily reproducible samples such as liquids, it is incompatible with many important systems. Here, we demonstrate collection of single-shot XAS spectra over 10s of eV using an XFEL source, with error bars of only a few percent. We additionally show how to extend this technique over wider spectral ranges towards Extended X-ray Absorption Fine Structure measurements, by concatenating a few tens of single-shot measurements. Our results pave the way for future XAS studies at XFELs, in particular those in the femtosecond regime. This advance is envisioned to be especially important for many transient processes that can only be initiated at lower repetition rates, for difficult to reproduce excitation conditions, or for rare samples, such as those encountered in high-energy density physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temporal pre-pulse shaping in dual pulse laser produced plasma for the optimization of the EUV source in tin microdroplet system

Dual-laser beams interacting with small droplets of liquid tin are currently the most efficient systems for producing the 13.5 nm EUV photon radiation source required for the next generation microchips. Usually, EUV light is produced during the second main-pulse stage, while the pre-pulse (PP) is used for target preparation, i.e., droplet preheating, vaporization, and target deformation. However, the PP laser energy can be utilized more efficiently if the EUV producing plasma is being developed during the PP stage as well. In this work, we study the ways of optimization of the PP laser temporal shape to achieve conditions for maximum EUV output during the pre-pulse. The size of the deformed droplet is kept optimized for the following main laser pulse. Our simulations showed a significant increase in the EUV output at the pre-pulse stage when a ramping profile is used for the laser temporal shape. Using the ramped square pre-pulse produces 24% gain in the EUV output in comparison with the standard Gaussian temporal profile (i.e., regular Nd:YAG shape) for the same energy of the laser pulse.

36 MATERIALS SCIENCE↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗

High-brightness self-seeded X-ray free-electron laser covering the 3.5 keV to 14.6 keV range

A self-seeded X-ray free-electron laser (XFEL) is a promising approach to realize bright, fully coherent free-electron laser (FEL) sources in the hard X-ray domain that have been a long-standing issue with longitudinal coherence remaining challenging. Additionally, at the Pohang Accelerator Laboratory XFEL, we have demonstrated a hard X-ray self-seeded XFEL with a peak brightness of 3.2 × 10 35 photons s –1 mm –2 mrad –2 0.1% bandwidth (BW) –1 at 9.7 keV. The bandwidth (0.19 eV) is about 1/70 times as wide (close to the Fourier transform limit) and the peak spectral brightness is 40 times higher than in self-amplified spontaneous emission (SASE), with substantial improvements in the stability of self-seeding and noticeably suppressed pedestal effects. We could reach an excellent self-seeding performance at a photon energy of 3.5 keV (lowest) and 14.6 keV (highest) with the same stability as the 9.7 keV self-seeding. The bandwidth of the 14.6 keV seeded FEL was 0.32 eV, and the peak brightness was 1.3 × 10 35 photons s –1 mm –2 mrad –2 0.1%BW –1 . We show that the use of seeded FEL pulses with higher reproducibility and a cleaner spectrum results in serial femtosecond crystallography data of superior quality compared with data collected using SASE mode.

47 OTHER INSTRUMENTATION↗

Applications of excimer lasers for atmospheric species measurements

Excimer lasers are proven sources of high pulse energy and high average power coherent radiation at several wavelength regions throughout the ultraviolet spectrum. If designed properly, excimer lasers can be operated with both low divergence and narrow spectral bandwidth, and using an oscillator - injection-locked amplifier configuration they can be tuned over a 10 to 20 A bandwidth without appreciable loss in energy. Additional wavelength coverage from excimer lasers can be obtained by stimulated Raman scattering. With the development of magnetic switching for the high voltage, high power switches, the electric discharge excimer laser can also be operated reliably for extended periods of time at high pulse rates. All these features make excimer lasers ideal sources of ultraviolet radiation for a variety of remote and in-situ atmospheric species measurements.

Laudenslager, J. B.↗