Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion beam analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of plasma measurements for the Geotail mission

The CPI plasma measurements from the Geotail spacecraft are currently used by a number of scientists in support of varied research projects. Measurements from the CPI hot plasma analyzer have been processed to compute one-minute averages of plasma densities, temperatures, and velocities for the period 1 Oct. 1992 - 31 July 1993. These parameters are used in a preliminary survey of the magnetotail for distances from earth of 10 to 210 earth radii. The cold plasmas within the magnetotail drift towards the midplane and are thought to be a principal source for the hot plasma sheet. A remarkable result from Geotail is the observation of cold ion beams coexisting as distinct components in the presence of hot plasma-sheet plasmas. The development and evolution of plasmoids is a topic of considerable interest in studies of the magnetotail and magnetospheric substorms. A number of possible plasmoids have been identified in the Geotail data set based upon reversals of the Z component of the magnetic field as observed with the MGF instrumentation. An intensive study of the electron and ion velocity distributions and the plasma parameters for several of these events reveals unexpected features. Collaborative work with several Geotail instrument teams and other researchers is also ongoing.

Frank, Louis A.↗

Thermal Electron Contributions to Current-Driven Instabilities: SCIFER Observations in the 1400-km Cleft Ion Fountain and Their Implications to Thermal Ion Energization

SCIFER TECHS observations of the variations in the thermal electron distribution in the 1400-km altitude cleft are associated with periods of intense ion heating and field-aligned currents. Energization of the thermal ion plasma in the mid-altitude cleft occurs within density cavities accompanied by enhanced thermal electron temperatures, large field-aligned thermal electron plasma flows and broadband low-frequency electric fields. Variations in the thermal electron contribution to field-aligned current densities indicate small scale (approximately 100's m) filamentary structure embedded within the ion energization periods. TECHS observations of the field-aligned drift velocities and temperatures of the thermal electron distribution are presented to evaluate the critical velocity thresholds necessary for the generation of electrostatic ion cyclotron and ion acoustic instabilities. This analysis suggests that, during periods of thermal ion energization, sufficient drift exists in the thermal electron distribution to excite the electrostatic ion cyclotron instability. In addition, brief periods exist within the same interval where the drift of the thermal electron distribution is sufficient to marginally excite the ion acoustic instability. In addition, the presence an enhancement in Langmuir emission at the plasma frequency at the center of the ion energization region, accompanied by the emission's second-harmonic, and collocated with observations of high-frequency electric field solitary structures suggest the presence of electron beam driven decay of Langmuir waves to ion acoustic modes as an additional free energy source for ion energization.

Adrian, Mark L.↗

Global polarization of Λ and $\overline{Λ}$ hyperons in Au + Au collisions at $\sqrt{s_{NN}}$ = 19.6 and 27 GeV

In relativistic heavy-ion collisions, a global spin polarization, 𝑃 H , of Λ and $\overline{Λ}$ hyperons along the direction of the system angular momentum was discovered and measured across a broad range of collision energies and demonstrated a trend of increasing 𝑃 H with decreasing $\sqrt{s_{NN}}$. A splitting between Λ and $\overline{Λ}$ polarization may be possible due to their different magnetic moments in a late-stage magnetic field sustained by the quark-gluon plasma which is formed in the collision. The results presented in this study find no significant splitting at the collision energies of $\sqrt{s_{NN}}$ = 19.6 and 27 GeV in the BNL Relativistic Heavy Ion Collisions Beam Energy Scan Phase II using the STAR detector, with an upper limit of 𝑃 $\overline{Λ}$ – 𝑃 Λ < 0.24% and 𝑃 $\overline{Λ}$ – 𝑃 Λ < 0.35%, respectively, at a 95% confidence level. We derive an upper limit on the naive extraction of the late-stage magnetic field of 𝐵 < 9.4 × 10 12 T and 𝐵 < 1.4 × 10 13 T at $\sqrt{s_{NN}}$ = 19.6 and 27 GeV, respectively, although more thorough derivations are needed. Differential measurements of 𝑃 H were performed with respect to collision centrality, transverse momentum, and rapidity. With our current acceptance of |𝑦| < 1 and uncertainties, we observe no dependence on transverse momentum and rapidity in this analysis. Furthermore, these results challenge multiple existing model calculations following a variety of different assumptions which have each predicted a strong dependence on rapidity in this collision-energy range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-situ observations of cyclic deformation in an extruded Mg-2Nd-1Y-0.1Zr-0.1Ca alloy

In this study, the evolution of deformation mechanisms during cyclic loading in an extruded, solution-treated Mg–2Nd–1Y–0.1Zr–0.1Ca alloy was investigated using a combination of in-situ loading, scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and focused ion beam (FIB) nanofabrication. The initial microstructure exhibited a random crystallographic texture with no preferred grain orientation. Flat, rectangular dog-bone specimens were subjected to load-controlled, fully reversed fatigue for 50 cycles, during which the same region was sequentially mapped to track microstructural changes. After 10 cycles of loading deformation twins were observed. During tensile reloading detwinning or narrowing of those twinned regions occurred. After 20 cycles, detwinning ceased and residual twins remained in the material. SEM imaging revealed numerous surface slip traces after cyclic loading. EBSD-assisted slip trace analysis identified the activation of prismatic and pyramidal < c+a> slip systems during low-cycle fatigue. Site-specific scanning transmission electron microscopy (STEM) further revealed that deformation was also accommodated by basal < a> slip and the dissociation of < c+a> dislocations. Center-of-symmetry (COS) analysis confirmed that the dissociation of < c+a> dislocations resulted in the formation of I₁ intrinsic stacking faults after cyclic loading. These findings provide new insights into the complex interplay of dislocation mechanisms governing fatigue deformation in rare-earth-containing Mg alloys.

Cyclic deformation↗

Linear stability of the H(+) - O(+) two-stream interaction in a magnetized plasma

The Bergman and Lotko (1986) analysis of the linear stability of the H(+) - O(+) two-stream interactions for parallel propagating wave modes is extended to an analysis of the stability of wave modes that propagate at an angle to the terrestrial magnetic field. The analaysis provides an insight into the manner in which the oblique modes linearly couple and become unstable; the conditions under which the particular couplings are important; the qualitative behavior of the frequency, wave vector, and growth rate of the most unstable mode; and the changes to these introduced by finite ion temperatures. Consideration is also given to the relative importance of obliquely propagating and parallel propagating waves for the condition when the velocity difference between two ion beams is below the upper limit.

Bergmann, R.↗

In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer

A miniaturized instrument for performing chemical and isotopic analysis of rocks has been developed. The rock sample is ablated by a laser and the neutral species produced are analyzed using the JPL-invented miniature mass spectrometer. The direct sampling of neutral ablated material and the simultaneous measurement of all the elemental and isotopic species are the novelties of this method. In this laser ablation-miniature mass spectrometer (LA-MMS) method, the ablated neutral atoms are led into the electron impact ionization source of the MMS, where they are ionized by a 70-eV electron beam. This results in a secondary ion pulse typically 10-100 microsecond wide, compared to the original 5-10-nanosecond laser pulse duration. Ions of different masses are then spatially dispersed along the focal plane of the magnetic sector of the miniature mass spectrometer and measured in parallel by a modified CCD (charge-coupled device) array detector capable of detecting ions directly. Compared to conventional scanning techniques, simultaneous measurement of the ion pulse along the focal plane effectively offers a 100% duty cycle over a wide mass range. LAMMS offers a more quantitative assessment of elemental composition than techniques that detect laser-ionized species produced directly in the ablation process because the latter can be strongly influenced by matrix effects that vary with the structure and geometry of the surface, the laser beam, and the ionization energies of the elements. The measurement of high-precision isotopic ratios and elemental composition of different rock minerals by LAMMS method has been demonstrated. The LA-MMS can be applied for the absolute age determination of rocks. There is no such instrument available presently in a miniaturized version that can be used for NASA space missions. Work is in progress in the laboratory for geochronology of rocks using LA-MMS that is based on K-Ar radiogenic dating technique.

Sinha, Mahadeva P.↗

GERMcode: A Stochastic Model for Space Radiation Risk Assessment

A new computer model, the GCR Event-based Risk Model code (GERMcode), was developed to describe biophysical events from high-energy protons and high charge and energy (HZE) particles that have been studied at the NASA Space Radiation Laboratory (NSRL) for the purpose of simulating space radiation biological effects. In the GERMcode, the biophysical description of the passage of HZE particles in tissue and shielding materials is made with a stochastic approach that includes both particle track structure and nuclear interactions. The GERMcode accounts for the major nuclear interaction processes of importance for describing heavy ion beams, including nuclear fragmentation, elastic scattering, and knockout-cascade processes by using the quantum multiple scattering fragmentation (QMSFRG) model. The QMSFRG model has been shown to be in excellent agreement with available experimental data for nuclear fragmentation cross sections. For NSRL applications, the GERMcode evaluates a set of biophysical properties, such as the Poisson distribution of particles or delta-ray hits for a given cellular area and particle dose, the radial dose on tissue, and the frequency distribution of energy deposition in a DNA volume. By utilizing the ProE/Fishbowl ray-tracing analysis, the GERMcode will be used as a bi-directional radiation transport model for future spacecraft shielding analysis in support of Mars mission risk assessments. Recent radiobiological experiments suggest the need for new approaches to risk assessment that include time-dependent biological events due to the signaling times for activation and relaxation of biological processes in cells and tissue. Thus, the tracking of the temporal and spatial distribution of events in tissue is a major goal of the GERMcode in support of the simulation of biological processes important in GCR risk assessments. In order to validate our approach, basic radiobiological responses such as cell survival curves, mutation, chromosomal aberrations, and representative mouse tumor induction curves are implemented into the GERMcode. Extension of these descriptions to other endpoints related to non-targeted effects and biochemical pathway responses will be discussed.

Kim, Myung-Hee Y.↗

A methodology for customizing implantation profiles of light ions using a single thin foil energy degrader

We report a method was developed to quantify the spatial distribution and implantation depth of energy-degraded light ions with a thin foil rotating energy degrader for use during multiple ion beam irradiation. The methodology covers three physical phenomena: ions passing through the thin foil, ions travelling through the vacuum to the target, and ion implantation into the target, and accounts for the distribution of ions both in depth and in plane. The processes of energy straggling and scattering were calculated using SRIM. The effects of raster-scanning, and the geometry of the system were implemented in scripts handling the SRIM output files. Elastic backscattering (EBS) using 2.38 MeV H+ protons was used to measure the helium depth profiles after implantation with and without thin foil energy degradation. Defect analysis with transmission electron microscopy confirmed the implantation profiles measured with EBS and calculated with SRIM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of minority-carrier lifetime and surface recombination velocity with high spacial resolution

Quantitative analysis of the electron beam induced current in conjunction with high-resolution scanning makes it possible to evaluate the minority-carrier lifetime three dimensionally in the bulk and the surface recombination velocity two dimensionally, with a high spacial resolution. The analysis is based on the concept of the effective excitation strength of the carriers which takes into consideration all possible recombination sources. Two-dimensional mapping of the surface recombination velocity of phosphorus-diffused silicon diodes is presented as well as a three-dimensional mapping of the changes in the minority-carrier lifetime in ion-implanted silicon.

Watanabe, M.↗

A guided ion beam investigation of UO 2 + thermodynamics and f orbital participation: Reactions of U + + CO 2 , UO + + O 2 , and UO + + CO

A guided ion beam tandem mass spectrometer was employed to study the reactions of U + + CO 2 , UO + + O 2 , and the reverse of the former, UO + + CO. Reaction cross sections as a function of kinetic energy over about a three order of magnitude range were studied for all systems. The reaction of U + + CO 2 proceeds to form UO + + CO with an efficiency of 118% ± 24% as well as generating UO 2 + + C and UCO + + O. The reaction of UO + + O 2 forms UO 2 + in an exothermic, barrierless process and also results in the collision-induced dissociation of UO + to yield U + . In the UO + + CO reaction, the formation of UO 2 + in an endothermic process is the dominant reaction, but minor products of UCO + + O and U + + (O + CO) are also observed. Analysis of the kinetic energy dependences observed provides the bond energies, D 0 (U + –O) = 7.98 ± 0.22 and 8.05 ± 0.14 eV, D 0 (U + –CO) = 0.73 ± 0.13 eV, and D 0 (OU + –O) = 7.56 ± 0.12 eV. The values obtained for D 0 (U + –O) and D 0 (OU + –O) agree well with the previously reported literature values. To our knowledge, this is the first experimental measurement of D 0 (U + –CO). Furthermore, an analysis of the oxide bond energies shows that participation of 5f orbitals leads to a substantial increase in the thermodynamic stability of UO 2 + relative to ThO 2 + and especially transition metal dioxide cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

591 MHz SRF Cavity Design for the EIC ESR

The Electron-Ion Collider (EIC) is a next generation particle accelerator to be built at Brookhaven National Laboratory, in partnership with Thomas Jefferson National Accelerator Facility. The Electron Storage Ring (ESR) of RIC requires a 10 MW RF storage system to restore beam power lost by a 2.5 A electron beam. The RF system will use 18 single-cell 591 MHz Superconducting RF (SRF) cavities. Effective damping of higher-order-modes (HOMs) is critical to ensure beam stability. This paper presents the design of the single-cell 591 MHz cavity, including cavity geometry optimization, multipacting evaluation, and HOM damping analysis.

43 PARTICLE ACCELERATORS↗

Upper Limit for the 248 Cm( 50 Ti, x n) 298− x Og Reaction Cross Section

After the synthesis of element 113, nihonium (Nh) via the 209 Bi( 70 Zn,n) 278 Nh cold fusion reaction using the RIKEN heavy-ion Linear ACcelerator (RILAC) and the GAs-filled Recoil Ion Separator (GARIS), the search for the heaviest isotopes of oganesson was initiated with GARIS-II by means of the 248 Cm( 50 Ti,xn) 298−x Og fusion evaporation reaction. The optimal bombarding energy for the 50 Ti + 248 Cm reaction was determined from the quasielastic barrier distribution extracted from the excitation function of quasielastic backscattering. Here, this method optimizes the compound nucleus formation. The search for Og was conducted for 39 days on the basis of the experimentally derived 50 Ti beam energy of 227.9(5) MeV at the middle of 248 Cm target. A precise analysis of the dataset based on multiple event search strategies revealed no decay chains with a total dose on 248 Cm target of 4.93 × 10 18 50 Ti projectiles, reaching a sensitivity of 0.27 pb and a 1σ upper cross section limit of 0.50 pb.

Gall, Benoît Jean-Paul [University of Strasbourg (↗

Electric Field Analysis in a Cold-Ion Source Using Stark Spectroscopy of Rydberg Atoms

Here, we analyze electric fields in ion sources generated by quasicontinuous photoionization of cold Rb atoms trapped in the focal spot of a near-concentric, in-vacuum cavity for 1064-nm laser light. Ion streams are extracted with an external electric field, F. Stark effects of Rb 57F and of nearby high-angular-momentum Rydberg levels, which exhibit large, linear Stark shifts, are employed to study the net electric-field probability distribution within the ion-source region over an extraction-field range of 0 < F < 0.35 V/cm. For F = 0, we also investigate ion-field-induced Stark spectra of the 60P 1/2 state, which exhibits a (lesser) quadratic electric-field response that affords a simplified electric-field analysis. Experimental Rydberg spectra are compared with theoretical Stark spectra, which are weighted with net electric-field distributions obtained from classical ion-trajectory simulations that include Coulomb interactions. Experiments and models are in good agreement. At small F and high ion-source rates, the field approximately follows a Holtsmark distribution, and the ion streams are degraded by the Coulomb microfields. With increasing F and at lower ion-source rates, the fields become narrowly distributed around F, resulting in directional ion streams that are less degraded by microfields. Our results are of interest for monitoring cold-ion sources for focused-ion-beam applications, where Coulomb interactions are of concern, and for studies of electric fields in cold plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermal simulation of the EIC HSR interconnect module - RF fingers

The Electron Ion Collider (EIC) Hadron Storage Ring (HSR) will reuse most of the existing superconducting magnets from the RHIC storage ring. However, the existing beam vacuum chamber and stripline BPMs will not be compatible with the planned EIC hadron bunches that will have a 3x higher intensity and be 10x shorter, and some operational scenarios with large radial offsets of the beam in the vacuum chamber. To address these challenges, a copper coated beam screen will be implemented, the existing RHIC stripline BPMs will be shielded and an interconnect module design, including new BPM will be installed adjacent to the existing BPMs. A thermal analysis of the new arc BPM interconnect housing has been conducted to assess the heating caused by beam induced resistive wall heating and electron cloud heating. An analysis of the BPM module has been made and reported separately. This report will focus on the other side of the interconnect module, containing the RF fingers.

43 PARTICLE ACCELERATORS↗

Influence of substrate composition on size and chemical state of ion beam synthesised Co nanoparticles – Towards fabrication of electrodes for energy devices

A one-step approach to synthesize ultrafine transition metal particles (size < 5 nm) in carbon substrates is highly desirable for fabricating electrodes for energy devices. Herein, cobalt ion implantation into amorphous carbon films (a:C) and hydrogenated amorphous carbon films (a:CH) was explored, with the aim of synthesizing ultrafine metallic cobalt nanoparticles at room temperature. Co ions of 30 keV energy were implanted into the carbon films to achieve a Co areal density of 1.0 ± 0.1 × 10 17 atoms cm -2 . Rutherford backscattering measurements revealed that hydrogenated amorphous carbon films gave a broader Co depth distribution compared to the amorphous carbon films. Further, cross-sectional TEM analysis revealed that hydrogenated carbon films suppressed metallic Co nanoparticle aggregation, leading to the creation of ultrafine Co nanoparticles (size < 5 nm). Co L-edge X-ray absorption spectroscopy measurements confirmed the formation of predominantly metallic Co nanoparticles by ion implantation. Results conclusively demonstrate that the presence of hydrogen (~ 28 at%) in the carbon matrix facilitates the synthesis of ultrafine metallic Co nanoparticles during Co ion implantation.

36 MATERIALS SCIENCE↗

Thermal simulation of the HSR arc BPM Module for EIC

The Electron Ion Collider (EIC) Hadron Storage Ring (HSR) will reuse most of the existing superconducting magnets from the RHIC storage ring. However, the existing stripline beam position monitors (BPM) used for RHIC will not be compatible with the planned EIC hadron beam parameters that include higher intensity, shorter bunches, and some operational scenarios with large radial offsets of the beam in the vacuum chamber. To address these challenges, the existing RHIC stripline BPMs will be shielded, and a new BPM design using button pick-ups and integrated in a new vacuum interconnect/bellows assembly that will be installed adjacent to the existing BPMs. A thermal analysis of the new arc BPM housing and button pick-up design has been conducted to assess the effects caused by beam induced resistive wall heating and signal propagation through the button pick-up cables for several operational scenarios. This report will describe the analysis results to quantify the heat transfer and temperature distribution that can be expected on the new HSR cryogenic arc BPM housings, button pick-ups, and cryo-signal cables.

43 PARTICLE ACCELERATORS↗

Instabilities of low frequency, parallel propagating electromagnetic waves in the earth's foreshock region

An instability analysis is presented for parallel and antiparallel propagating electromagnetic waves generated by reflected and diffuse suprathermal ions upstream of the earth's bow shock. Calculations are performed on the basis of upstream particle observations made by the ISEE 1 Quadrispheric Lepedea instrument and low-energy electron measurements made by the ISEE 1 electron spectrometer for a single period. The electromagnetic dispersion relation is computed and the unstable modes and growth times of the fastest growing waves are determined. It is found that the reflected ions destabilize the plasma most strongly at a wave frequency 0.1 that of the ion gyrofrequency by a resonant ion beam instability for waves propagating upstream and by a nonresonant firehose-like instability for waves propagating downstream. The diffuse ions also destabilize the plasma most strongly at the same frequency by means of resonant instabilities of both right- and left-hand polarized waves propagating away from the bow shock.

Sentman, D. D.↗