Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interconnected network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Resilient, Rural, and Revolutionary: Salisbury Square's Direct-Current Affordable Microgrid Community: Preprint

The technology to interconnect buildings with a dedicated direct-current (DC) power distribution network is in place today; what is missing is a turnkey approach to designing a DC microgrid - and the business models allowing such systems to be deployed, owned, and operated at scale. To close this gap, the Salisbury Square Development Team, comprising clean-energy experts, has engineered a resilient community DC microgrid for an affordable housing community in Randolph, Vermont. Ten single-family, occupant-owned residences and 12 multifamily rental units will share locally generated and stored solar energy via a DC power distribution bus capable of operating during extended grid outages. With a DC power distribution network in place, each home will be equipped with high-efficiency DC lighting and appliances, operating alongside alternating current (AC) appliances, even during an islanded mode of operation. To obtain a comprehensive understanding of what is possible and achievable, the Team collaborated with the local utility, regulatory agencies, a national laboratory, energy-as-service providers, and vendors. The collaborators evaluated microgrid typologies, business models, and energy modeling, and analyzed electrification and resilience. Further, the Team applied the URBANoptTM (Urban Renewable Building and Neighborhood optimization, NREL 2022) software development kit (SDK) to Salisbury Square's single-family and multifamily buildings to validate workflows and identify needs for advanced capability. This paper addresses the barriers to entry, scalability, and impact on residents and system ownership. It also examines the analysis that informed the design and engineering of the DC microgrid and the opportunities to streamline the process.

DER↗

Enhancing Power Grid Resilience with Causal Loops Diagram and Bayesian Networks

Enhancing power grid resilience through improved analysis and planning of Distributed Energy Resources is a key for power system planner. This paper explores the integration of Causal Loop Diagrams (CLDs) and Bayesian Networks (BNs) for enhancing resilience in power systems, focusing on Distributed Energy Resources (DER) planning. By automating CLD analysis in Python's matplotlib, we present a tool for rapid model validation and structural accuracy, crucial for power system planners. This hybrid approach utilizes BNs for inferential depth and CLDs for dynamic system modeling, offering a comprehensive framework for policy formulation and collaborative strategy development against disruptions. Here, we highlight the tool's capability to identify and analyze interconnected feedback loops, facilitating a deeper understanding of DER integration's impact on network resilience. This work aims to bridge quantitative analysis and qualitative insights, addressing the limitations of each method while providing a robust model for power system resilience assessment.

14 SOLAR ENERGY↗

Risk assessment of safety-critical data communication in digital safety feature control system - 205

As one of the safety-critical systems in Advanced Power Reactor-1400 (APR-1400) nuclear power plant (NPP), the Engineered Safety Feature-Component Control System (ESF-CCS) employs safety data link and network communication for transmitting safety component actuation to effectively facilitate various safety-critical field controllers. However, data communication failure risk in the ESF-CCS has yet to be fully quantified, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In this study, a fault tree model was developed to assess the data link and data network failure-induced unavailability of a safety-critical system function used to generate an automated control signal for actuating design basis accident mitigation equipment. Especially, the risk of data communication failure in a digital safety feature control system was analyzed in consideration of interconnection between safety-critical controllers and the fault-tolerant algorithm implemented in the network configuration. Based on the developed fault tree model, case studies were performed to quantitatively assess the unavailability of ESF-CCS signal generation due to safety data link and network failure and their risk effect on safety signal generation unavailability. This study is expected to provide risk information on the safety-critical data communication in a digitalized NPP instrumentation and control system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using Mobile Agents and Overlay Networks to Secure Electrical Netoworks

ABSTRACT The use of wandering, mobile agents can provide a robust approach for managing, monitoring, and securing electrical distribution networks. However, the topological structure of electrical networks can affect system performance. For example, if the multi-agent system relies on a regular inspection rate (on average, points of interest are inspected with equal frequency), then locations that are not well connected will on average be inspected less frequently. This paper discusses creation and use of overlay networks that create a virtual grid graph can provide faster coverage and a more uniform average agent sampling rate. Using overlays agents wander a virtual neighborhood consisting of only points of interest that are interconnected in a regular fashion (each point has the same number of neighbors). Experimental results will show that an overlay can often provide better network coverage and a more uniform inspection rate, which can improve cyber security by providing a faster detection of threats

Dawes, Neal A.↗

Stochasticity of Pores Interconnectivity in Li–O 2 Batteries and its Impact on the Variations in Electrochemical Performance

While large dispersions in electrochemical performance have been reported for lithium oxygen batteries in the literature, they have not been investigated in any depth. The variability in the results is often assumed to arise from differences in cell design, electrode structure, handling and cell preparation at different times. An accurate theoretical framework turns out to be needed to get a better insight into the mechanisms underneath and to interpreting experimental results. Here, we develop and use a pore network model to simulate the electrochemical performance of three-dimensionally resolved lithium-oxygen cathode mesostructures obtained from TXM nano-computed tomography images. Here, we apply this model to the 3D reconstructed object of a Super P carbon electrode and calculate discharge curves, using identical conditions, for four different zones in the electrode and their reversed configurations. The resulting galvanostatic discharge curves show some dispersion, (both in terms of capacity and overpotential) which we attribute to the way pores are connected with each other. Based on these results, we propose that the stochastic nature of pores interconnectivity and the microscopic arrangement of pores can lead, at least partially, to the variations in electrochemical results observed experimentally.

25 ENERGY STORAGE↗

Frequency Instability Problems in North American Interconnections

Alternating current power transmission and distribution systems in the United States operate at a nominal (target) frequency of 60 Hz. Large deviations from this frequency can cause network instability, and even small deviations can adversely affect sensitive end-use devices. Frequency deviations commonly result from a mismatch between energy supply and demand on a power network. If supply is insufficient to meet demand, the system frequency will decrease; if supply exceeds demand, frequency will increase. Over 100 balancing authorities within four electrical interconnections in North America manage power flows so that frequency will remain stable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biomimetic, Soft-Material Synapse for Neuromorphic Computing: from Device to Network

Neuromorphic computing refers to a variety of brain-inspired computers, devices, and models inspired by the interconnectivity, performance, and energy efficiency of the human brain. Unlike the ubiquitous von Neumann computer architectures with complex processor cores and sequential computation, biological neurons and synapses operate by storing and processing information simultaneously with the capacity of flexible adaptation resulting in massive computational capability with much less power consumption. The search for a synaptic material which can closely imitate bio-synapse has led to an alamethicin-doped, synthetic biomembrane which can emulate key synaptic functions due to generic memristive property enabling learning and computation. This two-terminal, biomolecular memristor, in contrast to its solid-state counterparts, features similar structure, switching mechanism, and ionic transport modality as biological synapses while consuming considerably lower power. In this paper, we outline a methodology for using this biomolecular synapse to build neural networks capable of solving real-world problems. The physical mechanism underlying its volatile memristance is explored followed by the development of a model of this device for circuit simulation. We outline a circuit design technique to integrate this synapse with solid-state neuron circuit for hardware implementation. Based on these results, we develop a high level simulation framework and use a training scheme called Evolutionary Optimization for Neuromorphic System (EONS) to generate networks for solving two problems, namely iris dataset classification and EEG classification task. The small network size and comparable to state-of-the-art accuracy of these preliminary networks show its potential to enhance synaptic functionality in next generation neuromorphic hardware.

Sakib hasan, Md↗

An Overview of Inverter-based Resource Interconnection Standards

For the past century, electric power systems have primarily been bulk power systems consisting of generation, transmission, and distribution networks. Now the rapid expansion of distributed renewable power sources (RESs) and the shift from large, conventional synchronous machine resources to smaller-sized resources with diverse generation characteristics become the most significant change in modern power systems. With the increasing penetration of RESs, which are inverter-based resources (IBRs), it is important to develop interconnection standards that define performance and capability criteria for these IBRs. This is necessary to ensure the stable and reliable operation of power systems. This report summarizes the standards for IBRs interconnection in North America.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and characterization of ultra-stretchable monolithic silicon fabric

Stretchable electronic systems can play instrumental role for reconfigurable macro-electronics such as distributed sensor networks for wearable and bio-integrated electronics. Typically, polymer composite based materials and its deterministic design as interconnects are used to achieve such systems. Nonetheless, non-polymeric inorganic silicon is the predominant material for 90% of electronics. Therefore, we report the design and fabrication of an all silicon based network of hexagonal islands connected through spiral springs to form an ultra-stretchable arrangement for complete compliance to highly asymmetric shapes. Several design parameters are considered and their validation is carried out through finite element analysis. The fabrication process is based on conventional microfabrication techniques and the measured stretchability is more than 1000% for single spirals and area expansions as high as 30 folds in arrays. The reported method can provide ultra-stretchable and adaptable electronic systems for distributed network of high-performance macro-electronics especially useful for wearable electronics and bio-integrated devices.

36 MATERIALS SCIENCE↗

Regulatory Protection and Control Standards Applicable to The Vietnam Grid Under High Inverter-Based Resource (IBR) Penetration: A Review of Standards Applicable for Vietnam Grid

This report provides a review of the current standards and practices followed by regulatory authorities for interconnection of inverter-based resources (IBR). With the increased penetration of IBRs into the transmission and distribution networks, the legacy protection methodologies are getting challenged. Due to the lack of regulations on IBR operations under a fault it is essential to have a thorough understanding of the present-day interconnection standards to ensure proper IBR operations. A focus is placed on the regulation and standards enforced by the North American Reliability Corporation (NERC), Federal Energy Regulatory Commission (FERC), Institute of Electrical and Electronics Engineer (IEEE), Underwriters Laboratories (UL) and other regulations proposed by the responsible commissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New trends in photonic switching and optical networking architectures for data centers and computing systems [Invited]

The rapid increases in data traffic coupled with user preferences are driving the data center and computing system service providers to offer energy-efficient, intelligent, flexible, cost-effective, high-capacity, and low-latency data services without added complexity to the users. Disaggregated heterogeneous reconfigurable computing systems realized by photonic switching and interconnects can enhance throughput and energy efficiency for artificial intelligence/machine learning (AI/ML) workloads, especially when aided by the AI/ML-enhanced control plane. Photonic switching and new optical networking architectures are expected to solve many of these challenging problems. This paper discusses new trends in photonic switching and optical network architectures for future data centers and computing systems summarized as follows: (1) flat reconfigurable disaggregated computing enabled by high-radix photonic switching and interconnects in data centers; (2) chiplet-based computing architectures empowered by embedded photonics toward heterogeneous reconfigurable computing; (3) nanosecond-scale photonic switching in data centers and computing systems; (4) AI/ML in self-driving, application-aware, and situation-aware data centers; (5) the emergence of flexible networking for cloud computing, edge computing, and split computing, as well as flexible networking for 5G/6G RF-optical networks; and (6) the deployment of embedded co-designed silicon photonics being considered for future data centers.

Yoo, S. J. Ben (ORCID:0000000274201871)↗

Extensive site-directed mutagenesis reveals interconnected functional units in the alkaline phosphatase active site

Enzymes enable life by accelerating reaction rates to biological timescales. Conventional studies have focused on identifying the residues that have a direct involvement in an enzymatic reaction, but these so-called ‘catalytic residues’ are embedded in extensive interaction networks. Although fundamental to our understanding of enzyme function, evolution, and engineering, the properties of these networks have yet to be quantitatively and systematically explored. We dissected an interaction network of five residues in the active site of Escherichia coli alkaline phosphatase. Analysis of the complex catalytic interdependence of specific residues identified three energetically independent but structurally interconnected functional units with distinct modes of cooperativity. From an evolutionary perspective, this network is orders of magnitude more probable to arise than a fully cooperative network. From a functional perspective, new catalytic insights emerge. Further, such comprehensive energetic characterization will be necessary to benchmark the algorithms required to rationally engineer highly efficient enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Structural Stability of Carbon Nanotube Films: The Role of Bending Buckling

In films, mats, buckypaper, and other materials composed of carbon nanotubes (CNTs), individual CNTs are bound together by van der Waals forces and form entangled networks of bundles. Mesoscopic dynamic simulations reproduce the spontaneous self-assembly of CNTs into continuous networks of bundles and reveal that the bending buckling and the length of CNTs are the two main factors responsible for the stability of the network structures formed by defect-free CNTs. Bending buckling of CNTs reduces the bending energy of interconnections between bundles and stabilizes the interconnections by creating effective barriers for CNT sliding. The length of the nanotubes is affecting the ability of van der Waals forces of intertube interactions to counterbalance the internal straightening forces acting on curved nanotubes present in the continuous networks. The critical length for the formation of stable network structures is found to be ~120 nm for (10,10) single-walled CNTs. In the simulations where the bending buckling is artificially switched off, the network structures are found to be unstable against disintegration into individual bundles even for micrometer-long CNTs.

Chemistry↗

A generative graph model for electrical infrastructure networks

We propose a generative graph model for electrical infrastructure networks that accounts for heterogeneity in both node and edge type. To inform the design of this model, we analyze the properties of power grid graphs derived from the U.S. Eastern Interconnection, Texas Interconnection, and Poland transmission system power grids. Across these datasets, we find subgraphs induced by nodes of the same voltage level exhibit shared structural properties atypical to small-world networks, including low local clustering, large diameter and large average distance. On the other hand, we find subgraphs induced by transformer edges linking nodes of different voltage types contain a more limited structure, consisting mainly of small, disjoint star graphs. The goal of our proposed model is to match both these inter and intra-network properties by proceeding in two phases: we first generate subgraphs for each voltage level and then generate transformer edges that connect these subgraphs. The first phase of the model adapts the Chung-Lu random graph model, taking desired vertex degrees and desired diameter as inputs, while the second phase of the model is based on a simpler random star graph generation process. We test the performance of our model by comparing its output across many runs to the aforementioned real data. In nearly all categories tested, we find our model is more accurate in reproducing the unusual mixture of properties apparent in the data than the Chung-Lu model. We also include graph visualization comparisons, as well as a brief analysis of edge-deletion resiliency. Ultimately, our model may be used to generate synthetic graph data, test hypotheses and algorithms at different scales, and serve as a baseline model on top of which further electrical network properties, device models, and interdependencies to other networks, may be appended.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Systems Integration Facility (ESIF): World-Class Systems Integration Capabilities and Research

The Energy Systems Integration Facility (ESIF), located at the National Renewable Energy Laboratory (NREL) South Table Mountain campus, is a world-renowned user facility for research and development of modern, advanced, and clean energy technologies. ESIF is distinguished by its continuously evolving, highly integrated systems that span throughout the building, connecting research capabilities across multiple laboratories and test areas. The primary ESIF research systems include: [1] data, cyber, and control networks, [2] research electrical distribution buses (REDB), [3] thermal integration infrastructure, and [4] hydrogen systems. The data, cyber, and control networks provide monitoring, control, communication, automation, visualization, and time series data storage and tagging capabilities for research projects and ESIF systems, including facility safety functions. The REDB system consists of four dedicated AC and DC electrical power networks that can connect devices located across the facility through versatile, automatic circuit configuration to support complex power electronics experiments up to the megawatt-scale. The thermal integration infrastructure consists of three temperature-conditioned water loops that provide heating and cooling interfaces and capabilities for thermal energy research. The hydrogen systems provide megawatt-scale hydrogen production, drying, compression, high-pressure storage, and delivery to laboratory end uses, including hydrogen fuel cell vehicle fueling. The ESIF research systems interconnect and extend throughout the various lab areas of the facility to create elaborate networks composed of diverse technologies for cutting-edge research. The ESIF capabilities are operated and stewarded by the ESIF Research Operations group, who also actively upgrade and advance the systems to ensure they remain ahead of anticipated research - enabling the success of many pioneering energy integration projects. The poster, created by members of the ESIF Research Operations team, highlights and summarizes the four core integrated systems at ESIF. The poster was first presented at the internal NREL Energize Forum on May 13th, 2024, and received the "Best Poster" award.

capabilities↗

Superconducting neural networks with disordered Josephson junction array synaptic networks and leaky integrate-and-fire loop neurons

Fully coupled randomly disordered recurrent superconducting networks with additional open-ended channels for inputs and outputs are considered the basis to introduce a new architecture to neuromorphic computing in this work. Various building blocks of such a network are designed around disordered array synaptic networks using superconducting devices and circuits as an example, while emphasizing that a similar architectural approach may be compatible with several other materials and devices. A multiply coupled (interconnected) disordered array of superconducting loops containing Josephson junctions [equivalent to superconducting quantum interference devices (SQUIDs)] forms the aforementioned collective synaptic network that forms a fully recurrent network together with compatible neuron-like elements and feedback loops, enabling unsupervised learning. This approach aims to take advantage of superior power efficiency, propagation speed, and synchronizability of a small world or a random network over an ordered/regular network. Additionally, it offers a significant factor of increase in scalability. Here, a compatible leaky integrate-and-fire neuron made of superconducting loops with Josephson junctions is presented, along with circuit components for feedback loops as needed to complete the recurrent network. Several of these individual disordered array neural networks can further be coupled together in a similarly disordered way to form a hierarchical architecture of recurrent neural networks that is often suggested as similar to a biological brain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Livermore Big Artificial Neural Network Toolkit

LBANN is a toolkit that is designed to train artificial neural networks efficiently on high performance computing architectures. It is optimized to take advantages of key High Performance Computing features to accelerate neural network training. Specifically it is optimized for low-latency, high bandwidth interconnects, node-local NVRAM, node-local GPU accelerators, and high bandwidth parallel file systems. It is built on top of the open source Elemental distributed-memory dense and spars-direct linear algebra and optimization library that is released under the BSD license. The algorithms contained within LBANN are drawn from the academic literature and implemented to work within a distributed-memory framework.

Essen, BrianVan↗

IceNet for FireBox - A Berkeley Warehouse-Scale Computer

Berkeley’s FireBox is a next-generation warehouse-scale computer (WSC) that utilizes the energy-efficiency and bandwidth density of integrated silicon-photonic interconnects to enable a new high-bandwidth and low-latency network fabric connecting thousands of compute nodes to petabytes of DRAM and Flash storage. The high bandwidth, low latency and high connectivity of FireBox’s WSC network fabric (IceNet) will enable dramatic improvements in the overall system energy efficiency enabling fine-grain power control on system resources (processors, links and memory/storage components). IceNet is a special 3-stage photonic Clos network architected to achieve ultra-low-latency connectivity between processor nodes and memory, drastically cutting down on the energy wasted in resource idling (processors and memory stalled due to pending network requests). This is achieved by integration of the first and last switch stages into processor/memory hub clients and by heavy over-provisioning of the high-radix middle switches (FlareSwitches). A key hardware component developed in this program is an active laser power management photonic integrated circuits called LightSpark. It interacts with the FlareSwitch and provides laser power to a subset of occupied switch ports, increasing the utilization of laser light in the photonic network by an order of magnitude. In addition to guiding the laser power where it is needed, the laser-power management module enables both wavelength and laser redundancy, significantly increasing the robustness of the system. The goal of the IceNet fabric is to enable communication between 1000s of processor nodes and PBs of memory/storage with <100ns latency, <10pJ/b wall-plug energy cost at multiple Pb/s of available connectivity bandwidth. These metrics represent two-orders of magnitude improvement with respect to the status of current data-center technology.

42 ENGINEERING↗