Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image understanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Demonstration of a time-integrated short line of sight neutron imaging system for inertial confinement fusion

The Neutron Imaging System (NIS) is an important diagnostic for understanding implosions of deuterium-tritium capsules at the National Ignition Facility. While the detectors for the existing system must be positioned 28 m from the source to produce sufficient imaging magnification and resolution, recent testing of a new short line of sight neutron imaging system has shown sufficient resolution to allow reconstruction of the source image with quality similar to that of the existing NIS on a 11.6 m line of sight. The new system used the existing pinhole aperture array and a stack of detectors composed of 2 mm thick high-density polyethylene converter material followed by an image plate. In these detectors, neutrons enter the converter material and interact with protons, which recoil and deposit energy within the thin active layer of the image plate through ionization losses. The described system produces time-integrated images for all neutron energies passing through the pinhole. We present details of the measurement scheme for this novel technique to produce energy-integrated neutron images as well as source reconstruction results from recent experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Receptive fields and visual representations

Efficient representation of images for human use requires an understanding of how the brain processes and represents visual information. Spatial imagery is represented in the brain in the receptive fields of visual neurons. Models of these neurons lead to models of image fidelity, and to digital implementations of these neural codes. This approach will be illustrated by two example codes. The advantages and difficulties of this approach will be discussed.

Watson, Andrew B.↗

Potential Improvements for the One-Dimensional Imager of Neutrons at the Sandia Z Facility

Understanding the neutron source shape is critical for improving Magnetized Liner Inertial Fusion (MagLIF) implosions at the Sandia Z machine. Neutron source-shape measurements for MagLIF are, however, challenging due to the yields, extended axial source regions, x-ray backgrounds and physical shock waves produced by MagLIF sources. Initial tests of a slit neutron imager for 1- dimensional neutron imaging along the axial dimension of MagLIF implosions have shown that a rolled-slit aperture and CR-39 plastic detector can image the neutron production along the axial dimension. In this whitepaper, we suggest straightforward improvements to the neutron imager design that will allow significantly improved signal-to-noise performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

110 Patients with adenosquamous carcinomas of the pancreas (PASC): imaging differentiation of small (≤ 3 cm) versus large (> 3 cm) tumors

Objective: This study examined radiological imaging features of small (≤ 3 cm) and large (> 3 cm) adenosquamous carcinomas of the pancreas (PASC) lesions to better understand the morphology of these lesions. Methods: Images from 110 patients with pathologically proven PASC (80 males and 30 females, mean age: 62.6 years) were retrospectively reviewed. Two radiologists analyzed images and reached a consensus regarding the following features: location, shape, margins, presence of solid and necrotic components, rim enhancement, density/intensity during the portal venous phase, invasion of surrounding organs, vascular invasion, venous tumor thrombus formation, and enlarged lymph nodes. Differences in the imaging features between the two groups were evaluated with the Chi-square test or Fisher’s exact test. Results: There were 41 small PASC lesions (mean age: 60.59 years) and 69 large PASC lesions (63.74 years). Statistical analysis demonstrated significant differences in the location, shape, adjacent organ and vessel invasion, and venous tumor thrombus formation (P < 0.05). Small PASC lesions were more frequently detected in the pancreatic head and had an ovoid shape. There was no significant difference in the presence of solid and necrotic components (P = 0.090), including approximately 3/4 of the lesions with necrosis and 1/4 purely solid lesions, enlarged lymph nodes (P = 0.068) and other features. Conclusion: Regardless of the tumor size, 75% of PASC lesions present with central necrosis while 25% are purely solid. Small PASC lesions can be associated with lymph node metastasis at a relatively early stage. Large PASC lesions are likely to invade adjacent tissues and be associated with venous tumor thrombus formation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental adventures in variable-density mixing

Variable-density mixing occurs in the ocean and atmosphere, inertial confinement fusion capsules, stars, and many industrial processes. Our team studies mixing at the laboratory scale, with the goal of extending our understanding to larger and smaller length scales and into multiphysics regimes that include such physics as chemical and thermonuclear reactions and high energy density plasmas. I will provide examples of studies from Los Alamos in variable-density mixing in multiple regimes, including shock-driven mixing, subsonic mixing, and high energy density (HED) plasma mixing. In all cases, the density differences of the mixing fluids are at least double, making the mixing well outside regimes covered by the Boussinesq approximation. In these flows, we have discovered time-dependent mixing phenomena, asymmetries in mixing and distribution of turbulent kinetic energy, and interscale energy transfer driven by the mean ow that moves energy from small to large scales via eddy stretching. We have improved our physical understanding by implementing diagnostics such as particle image velocimetry and planar laser induced fluorescence in challenging, shock-driven ow regimes. Our experimental studies and physical understanding benefit from collaborations with colleagues studying turbulence modeling and performing validation simulations, and these collaborations push us to further improve our experimental platforms and diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Landform identification in lunar radar images

Lunar radar images have been investigated in order to understand how various radar parameters affect landform identification. The high-resolution (1-2 km cell size) 3.8-cm images of Zisk et al. (1974) were used along with the low and high resolution 70-cm mosaics of Thompson (1974 and 1987). The results indicate that radar cell size is the single most important radar parameter and that lunar features are likely to be correctly identified if they are longer than an 'identification resolution' of five times the radar cell size. The moon is considered here as an analog of Venus, since the two planets have similar mean scattering behavior.

Thompson, T. W.↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modes of Visual Recognition and Perceptually Relevant Sketch-based Coding for Images

A review of visual recognition studies is used to define two levels of information requirements. These two levels are related to two primary subdivisions of the spatial frequency domain of images and reflect two distinct different physical properties of arbitrary scenes. In particular, pathologies in recognition due to cerebral dysfunction point to a more complete split into two major types of processing: high spatial frequency edge based recognition vs. low spatial frequency lightness (and color) based recognition. The former is more central and general while the latter is more specific and is necessary for certain special tasks. The two modes of recognition can also be distinguished on the basis of physical scene properties: the highly localized edges associated with reflectance and sharp topographic transitions vs. smooth topographic undulation. The extreme case of heavily abstracted images is pursued to gain an understanding of the minimal information required to support both modes of recognition. Here the intention is to define the semantic core of transmission. This central core of processing can then be fleshed out with additional image information and coding and rendering techniques.

Jobson, Daniel J.↗

FEASIBILITY OF HELIOSPHERIC IMAGING FROM NEAR EARTH

Imaging solar wind structures via Thomson scattered sunlight has proved important to understanding the inner heliosphere. The principal challenge of heliospheric imaging is background subtraction: typical solar wind features are fainter than the zodiacal light and starfield by 2-3 orders of magnitude. Careful post-processing is required to separate the solar wind signal from the static background. Remnant background, and not photon noise, is the dominant noise source in current STEREO data. We demonstrate that 10× shorter exposure times would not strongly affect the noise level in these data. Further, we demonstrate that current processing techniques are sufficient to separate not only the existing background of the STEREO images but also diffuse variable backgrounds such as are expected to be seen from low Earth orbit. We report on a hare-and-hounds style study, demonstrating blind signal extraction from STEREO/HI-2 data that have been degraded by the addition of large-scale, time-dependent artifacts to simulate viewing through airglow or high-altitude aurora. We demonstrate removal of these effects via image processing, with little degradation compared to the original. Even with as few as three highly degraded source images over 48 hr, it is possible to detect and track large coronal mass ejections more than 40° from the Sun. This implies that neither the high altitude aurora discovered by Coriolis/SMEI, nor airglow effects seen from low Earth orbit, are impediments to a hypothetical next-generation heliospheric imager in low Earth orbit; and also that post-processing is as important to heliospheric image qualitiy as are optical contamination effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconstruction of simulated electrostatic potentials by automatic differentiation-based phase retrieval in electron microscopy imaging

Measuring interfacial electrostatic potentials is vital to understanding many fundamental materials properties. A variety of TEM methods exist for measuring electric potentials from the phase shift produced on an electron wave as it passes through a sample. However, most are either experimentally challenging or poorly suited to resolving nanoscale features. Here, we demonstrate the viability of a simple, automatic differentiation-based exit wave reconstruction from a focal series of images to accurately measure nanoscale electric potentials. Here, the analysis suggests that under optimal measurement conditions, electric potentials can be resolved to less than 0.06 V in magnitude and less than 1 nm in spatial extent.

36 MATERIALS SCIENCE↗

NASA IMAGESEER: NASA IMAGEs for Science, Education, Experimentation and Research

A number of web-accessible databases, including medical, military or other image data, offer universities and other users the ability to teach or research new Image Processing techniques on relevant and well-documented data. However, NASA images have traditionally been difficult for researchers to find, are often only available in hard-to-use formats, and do not always provide sufficient context and background for a non-NASA Scientist user to understand their content. The new IMAGESEER (IMAGEs for Science, Education, Experimentation and Research) database seeks to address these issues. Through a graphically-rich web site for browsing and downloading all of the selected datasets, benchmarks, and tutorials, IMAGESEER provides a widely accessible database of NASA-centric, easy to read, image data for teaching or validating new Image Processing algorithms. As such, IMAGESEER fosters collaboration between NASA and research organizations while simultaneously encouraging development of new and enhanced Image Processing algorithms. The first prototype includes a representative sampling of NASA multispectral and hyperspectral images from several Earth Science instruments, along with a few small tutorials. Image processing techniques are currently represented with cloud detection, image registration, and map cover/classification. For each technique, corresponding data are selected from four different geographic regions, i.e., mountains, urban, water coastal, and agriculture areas. Satellite images have been collected from several instruments - Landsat-5 and -7 Thematic Mappers, Earth Observing-1 (EO-1) Advanced Land Imager (ALI) and Hyperion, and the Moderate Resolution Imaging Spectroradiometer (MODIS). After geo-registration, these images are available in simple common formats such as GeoTIFF and raw formats, along with associated benchmark data.

Le Moigne, Jacqueline↗

TU-EF-207-00: Advances in Breast Imaging

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-02: Spectral Mammography Based on Photon Counting Detectors

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

Atom-by-atom imaging of moiré transformations in 2D transition metal dichalcogenides

Understanding the atomic-scale mechanisms that govern the structure of interfaces is critical across materials systems but particularly so for two-dimensional (2D) moiré materials. Here, we image, atom-by-atom, the thermally induced structural evolution of twisted bilayer transition metal dichalcogenides using in situ transmission electron microscopy. We observe low-temperature, local conversion of moiré superlattice into nanoscale aligned domains. Unexpectedly, this process occurs by nucleating a new grain within one monolayer, whose crystal orientation is templated by the other. The aligned domains grow through collective rotation of moiré supercells and hopping of 5|7 defect pairs at moiré boundaries. This provides mechanistic insight into the atomic-scale interactions controlling moiré structures and illustrates the potential to pattern interfacial structure and properties of 2D materials at the nanoscale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-EF-207-01: Introductory Remarks on Recent Advances in Breast Imaging

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-03: Advances in Stationary Breast Tomosynthesis Using Distributed X-Ray Sources

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-04: Advances in Detector Technology for Breast Tomosynthesis

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-05: Dedicated Cone-beam Breast CT

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗