Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Few-shot leaf segmentation

In this work, we use few-shot learning to segment the body and vein architecture of Populus trichocarpa leaves from high-resolution scans obtained in the UC Davis common garden. Leaf and vein segmentation are formulated as separate tasks, in which convolutional neural networks (CNNs) are used to iteratively expand partial segmentations until reaching stopping criteria. Our leaf and vein segmentation approaches use just 50 and 8 manually traced images for training, respectively, and are applied to a set of 2,634 top and bottom leaf scans. We show that both methods achieve high segmentation accuracy, in some cases exceeding even human-level segmentation. The leaf and vein segmentations are subsequently used to extract 68 morphological traits using traditional open-source image processing tools, which are validated using real-world physical measurements. For a biological perspective, we perform a genome-wide association study using the "vein density" trait to discover novel genetic architectures associated with multiple physiological processes relating to leaf development and function. In addition to sharing all of the few-shot learning code, we are releasing all images, manual segmentations, model predictions, 68 extracted leaf phenotypes, and a new set of SNPs called against the v4 P. trichocarpa genome for 1,419 genotypes.

Lagergren, John [Oak Ridge National Lab. (ORNL), O↗

PanFP: Pangenome-based functional profiles for microbial communities

For decades there has been increasing interest in understanding the relationships between microbial communities and ecosystem functions. Current DNA sequencing technologies allows for the exploration of microbial communities in two principle ways: targeted rRNA gene surveys and shotgun metagenomics. For large study designs, it is often still prohibitively expensive to sequence metagenomes at both the breadth and depth necessary to statistically capture the true functional diversity of a community. Although rRNA gene surveys provide no direct evidence of function, they do provide a reasonable estimation of microbial diversity, while being a very cost effective way to screen samples of interest for later shotgun metagenomic analyses. However, there is a great deal of 16S rRNA gene survey data currently available from diverse environments, and thus a need for tools to infer functional composition of environmental samples based on 16S rRNA gene survey data. As a result, we present a computational method called pangenome based functional profiles (PanFP), which infers functional profiles of microbial communities from 16S rRNA gene survey data for Bacteria and Archaea. PanFP is based on pangenome reconstruction of a 16S rRNA gene operational taxonomic unit (OTU) from known genes and genomes pooled from the OTU s taxonomic lineage. From this lineage, we derive an OTU functional profile by weighting a pangenome s functional profile with the OTUs abundance observed in a given sample. We validated our method by comparing PanFP to the functional profiles obtained from the direct shotgun metagenomic measurement of 65 diverse communities via Spearman correlation coefficients. These correlations improved with increasing sequencing depth, within the range of 0.8 0.9 for the most deeply sequenced Human Microbiome Project mock community samples. PanFP is very similar in performance to another recently released tool, PICRUSt, for almost all of survey data analysed here. But, our method is unique in that any OTU building method can be used, as opposed to being limited to closed reference OTU picking strategies against specific reference sequence databases. In conclusion, we developed an automated computational method, which derives an inferred functional profile based on the 16S rRNA gene surveys of microbial communities. The inferred functional profile provides a cost effective way to study complex ecosystems through predicted comparative functional metagenomes and metadata analysis. All PanFP source code and additional documentation are freely available online at GitHub.

16S rRNA survey↗

Supporting information for Few-Shot Learning Enables Population-Scale Analysis of Leaf Traits in Populus trichocarpa

In this work, we use few-shot learning to segment the body and vein architecture of P. trichocarpa leaves from high-resolution scans obtained in the UC Davis common garden. Leaf and vein segmentation are formulated as separate tasks, in which convolutional neural networks (CNNs) are used to iteratively expand partial segmentations until reaching stopping criteria. Our leaf and vein segmentation approaches use just 50 and 8 manually traced images for training, respectively, and are applied to a set of 2,634 top and bottom leaf scans. We show that both methods achieve high segmentation accuracy, in some cases exceeding even human-level segmentation. The leaf and vein segmentations are subsequently used to extract 68 morphological traits using traditional open-source image processing tools, which are validated using real-world physical measurements. For a biological perspective, we perform a genome-wide association study using the vein density trait to discover novel genetic architectures associated with multiple physiological processes relating to leaf development and function. In addition to sharing all of the few-shot learning code (see https://github.com/jlager/few-shot-leaf-segmentation), we are releasing all images, manual segmentations, model predictions, 68 extracted leaf phenotypes, and a new set of SNPs called against the v4 P. trichocarpa genome for 1,419 genotypes. The data folder includes all images, ground truth segmentations, predicted segmentations, and extracted leaf traits. All images encode the sample ID in the file name by indicating the treatment, block, row, position, and leaf side, respectively. For example, the file, C_1_1_2_bot.jpeg, indicates the control treatment, block 1, row 1, position 2, and the bottom side of the leaf. Tabulated results include position IDs as well as the corresponding genotype IDs. The images folder includes the 2,906 high-resolution leaf scans taken in the field. The leaf_masks folder includes 50 ground truth segmentations used for training the leaf tracing algorithm. The leaf_preds folder includes the 2,906 predicted segmentations from the leaf tracing algorithm. The vein_masks folder includes 8 ground truth segmentations used for training the vein growing algorithm. The vein_preds folder includes the 1,453 predicted segmentations from the vein growing algorithm. The vein_probs folder includes the 1,453 predicted probability maps from the vein growing algorithm before thresholding. The genomes folder includes the set of SNPs called against the v4 P. trichocarpa genome for 1,419 genotypes with a README file detailing the steps taken. The results folder includes: (i) raw values of the 68 predicted leaf traits in digital_traits.tsv, (ii) manually measured values of petiole length and width in manual_traits.tsv, (iii) thin plate spline (TPS) adjusted values of the vein density trait in vein_density_tps_adj.tsv, (iv) best linear unbiased prediction (BLUP) adjusted values of the vein density trait in vein_density_blups.tsv, and (v) GWAS results for the vein density trait, including chromosome positions and corresponding P values, in gwas_results.csv.

09 BIOMASS FUELS↗

The Los Alamos Science Pillars The Science of Signatures

As a national security science laboratory, Los Alamos is often asked to detect and measure the characteristics of complex systems and to use the resulting information to quantify the system's behavior. The Science of Signatures (SoS) pillar is the broad suite of technical expertise and capability that we use to accomplish this task. With it, we discover new signatures, develop new methods for detecting or measuring signatures, and deploy new detection technologies. The breadth of work at Los Alamos National Laboratory (LANL) in SoS is impressive and spans from the initial understanding of nuclear weapon performance during the Manhattan Project, to unraveling the human genome, to deploying laser spectroscopy instrumentation on Mars. Clearly, SoS is a primary science area for the Laboratory and we foresee that as it matures, new regimes of signatures will be discovered and new ways of extracting information from existing data streams will be developed.

Applied Life Science(60)↗

Johnson Noise Thermometry System Requirements

This document is intended to capture the requirements for the architecture of the developmental electronics for the ORNL-lead drift-free Johnson Noise Thermometry (JNT) project conducted under the Instrumentation, Controls, and Human-Machine Interface (ICHMI) research pathway of the U.S. Department of Energy (DOE) Advanced Small Modular Reactor (SMR) Research and Development (R&D) program. The requirements include not only the performance of the system but also the allowable measurement environment of the probe and the allowable physical environment of the associated electronics. A more extensive project background including the project rationale is available in the initial project report [1].

Britton, Jr., Charles L.↗

The Luminosity Measurement for the DZERO Experiment at Fermilab

Primary project objective: The addition of University of Nebraska-Lincoln (UNL) human resources supported by this grant helped ensure that Fermilab’s DZERO experiment had a reliable luminosity measurement through the end of Run II data taking and an easily-accessible repository of luminosity information for all collaborators performing physics analyses through the publication of its final physics results. Secondary project objective: The collaboration between the UNL Instrument Shop and Fermilab’s Scintillation Detector Development Center enhanced the University of Nebraska’s future role as a particle detector R&D and production facility for future high energy physics experiments. Overall project objective: This targeted project enhanced the University of Nebraska’s presence in both frontier high energy physics research in DZERO and particle detector development, and it thereby served the goals of the DOE Office of Science and the Experimental Program to Stimulate Competitive Research (EPSCoR) for the state of Nebraska.

47 OTHER INSTRUMENTATION↗

National Aeronautics and Space Administration FY 02 Revised Final Annual Performance Plan

The Government Performance and Results Act (GPRA) was passed by Congress and signed by the President in 1993. GPRA was enacted to improve the efficiency of all Federal agencies, with the following specific goals: (1) Improve Federal program management, effectiveness, and public accountability; (2) Improve Congressional decision making on where to commit the Nation's financial and human resources; and (3) Improve citizen confidence in government performance. GPRA directs Executive Branch agencies to develop a customer-focused strategic plan that aligns activities with concrete missions and goals. The Act directs agencies to manage and measure results to justify Congressional appropriations and authorizations. The Report Consolidation Act of 2000 directs agencies to provide a report on the degree of success in achieving the goals and performance measures defined in the strategic and performance plans one hundred and fifty days after the completion of the fiscal year.

Source record↗

Estimation Filter for Alignment of the Spitzer Space Telescope

A document presents a summary of an onboard estimation algorithm now being used to calibrate the alignment of the Spitzer Space Telescope (formerly known as the Space Infrared Telescope Facility). The algorithm, denoted the S2P calibration filter, recursively generates estimates of the alignment angles between a telescope reference frame and a star-tracker reference frame. At several discrete times during the day, the filter accepts, as input, attitude estimates from the star tracker and observations taken by the Pointing Control Reference Sensor (a sensor in the field of view of the telescope). The output of the filter is a calibrated quaternion that represents the best current mean-square estimate of the alignment angles between the telescope and the star tracker. The S2P calibration filter incorporates a Kalman filter that tracks six states - two for each of three orthogonal coordinate axes. Although, in principle, one state per axis is sufficient, the use of two states per axis makes it possible to model both short- and long-term behaviors. Specifically, the filter properly models transient learning, characteristic times and bounds of thermomechanical drift, and long-term steady-state statistics, whether calibration measurements are taken frequently or infrequently. These properties ensure that the S2P filter performance is optimal over a broad range of flight conditions, and can be confidently run autonomously over several years of in-flight operation without human intervention.

Bayard, David↗

Environmentally Friendly Rotorcraft Concepts: 2011-2014: US/France MoA Helicopter Aeromechanics - Task 5

Motivation: Greenhouse gas concentrations have increased well beyond their pre-industrial levels due to human activities; Aircraft emissions are becoming regulated in industrialized nations, so future rotorcraft will need to be designed for minimal environmental impact. Objectives: Determine suitable metrics to measure environmental impact of rotorcraft, focusing first on air pollution; Integrate performance metrics with rotorcraft design codes; Generate rotorcraft designs with minimal environmental impact. Outcomes: Obtain an understanding of how targeting reduced emissions affects the rotorcraft design process; Advance the capability of existing rotorcraft design tools to include environmental performance metrics. Tools: Evaluation and predesign - NDARC (NASA Design and Analysis of Rotorcraft) and CREATION (Concepts of Rotorcraft Enhanced Assessment Through Integrated Optimization Network); Flight simulation - CAMRAD II (Comprehensive Analytical Model of Rotorcraft Aerodynamics and Dynamics) and HOST (Helicopter Overall Simulation Tool).

Environmentally Friendly↗

Teal Cycle Ergometer Vibration Isolation and Stabilization System Human-in-the-Loop Ground Evaluation for Long-Duration Spaceflight

Purpose: To counter the deleterious effects of weightlessness on the cardiopulmonary system, astronauts living on the International Space Station exercise on a variety of countermeasure equipment including the Cycle Ergometer Vibration Isolation and Stabilization System (CEVIS). Operational since 2001, the onboard CEVIS will be replaced by a new model, known as Teal CEVIS (TC). As a part of ground evaluation, TC hardware underwent human-in-the-loop (HITL) testing to verify the TC hardware produces workloads that elicit physiologic responses comparable to a laboratory cycle ergometer (LAB). Methods: Seven subjects (5 M/2 F) performed submaximal cycle ergometer testing with indirect calorimetry measures on TC and LAB on separate test days. Testing consisted of graded 30 watt increases in workload until subjects reached 85% of age-predicted max heart rate (HR). Exercise outcomes included rate of oxygen uptake (VO2; liters/min), rate of energy expenditure (REE; kcal/min), and HR (beats/min). Linear mixed models (LMM) were fitted to compare VO2, REE, and HR responses between devices across power outputs with fixed effects for power (P) and device (D) and with random effects for subject. LMM effect coefficients (β), std errors (SE), pseudo-partial R2 of effects (pR2), and model likelihood ratio statistics (χ2, Pr(> chisq); α<.05) are provided. Results: LMM main effects for P and D were observed for VO2 (βp=.0107, SE = .0002, pR2=0.97; βd = -0.075, SE = 0.019, pR2=0.14; χ2(1)= 13.57, p<.001), such that VO2 was higher across stages on TC. Main effects of P and D were observed for REE (βp= .0586, SE = 0.001, pR2= 0.97; βd = -0.33208, SE = 0.099, pR2= 0.056; χ2(1)=10.481, p < .01), such that REE was higher across power outputs on TC. A P x D interaction was observed for HR, along with main effects for P and D (βp x d =-0.048, SE = 0.02, pR2=0.048; βp= 0.42, SE = 0.016, pR2=0.87; χ2(1) = 5.398, p = 0.02), such that higher workloads elicited a greater difference in HR between devices. Conclusions: HITL results show, TC elicits greater physiologic responses across power outputs compared to LAB. However, pR2 for device effects show small differences between devices. Therefore, TC can be expected to provide appropriate physiological stimulus across workloads and be considered a reliable tool to mitigate the effects of weightlessness.

Cycle Ergometer Vibration and Isolation System↗

Clinical Decision Support - Concepts of Operation

We are entering a new era in space exploration to return to the moon and explore Mars. Crew members operating independently during long duration space exploration missions will require a clinical decision support system (CDSS) to increase autonomy by augmenting their knowledge, skills and abilities in different scenarios. Significant changes to in-flight and habitat medical care due to constraints on mass, volume, power, crew time and medical evacuation capabilities are needed to increase crew autonomy and self-reliance in decision making and task performance. The Exploration Medical Capability (ExMC) Element of the Human Research Program (HRP) pushes the boundary of space medical systems to advance the care of astronauts on future exploration missions beyond low Earth orbit by identifying and testing next-generation medical care and crew health maintenance technologies. Clinical decision support (CDS) presents knowledge and data in a context aware manner to augment a crew members’ knowledge, skills and abilities during the process of observation, orientation, decisions and action. A comprehensive crew health and performance CDSS is required to augment crew capability and will be used in different scenarios for several reasons. In general, the CDSS’s role is to assist the crew in prevention, detection, diagnosis and treatment of crew health and performance related conditions that may arise in exploration spaceflight. For example, CDSS would assist a high acuity scenario such as a heart attack by supplying clear instructions, vital signs and treatment reminders. A lower severity scenario such as kidney stone risk could interface to vehicle systems and display more complex predictive data during a diagnosis. A CDSS needs to contribute to successful missions by maintaining a high performing crew who can potentially exhibit countless medical conditions related to derangements from the space environment (sleep, cognition, nutrition and exercise) as well as conditions intrinsic to humans anywhere. While supporting the crew’s ability to make sound clinical decisions is desirable in any mission, it is essential for exploration missions with significant communication delays, no evacuation capability, and extended exposure to the flight environment. Such missions correspond with medical Level of Care V (LOC V), the highest level specified in NASA-STD-3001. The project focuses on CDS implementation research to derive requirements for LOC V, where the need for increased autonomy results in new practices and the inclusion of non-clinical data, such as vehicle environmental measures and physical exercise results, from other human and vehicle domains and advanced analytics. The CDS project describes how the CDSS is intended to be used by defining concepts of operations (ConOps). The process to derive ConOps focuses on increased autonomy that reduces the likelihood and consequences of accepted medical conditions. These crew health and performance inputs are grouped by common datasets and analysis models. Use cases are derived to research new clinical scenarios, architectural development and workflows. Implementation research is conducted with protypes to inform assumptions and derive requirements. The project also establishes how externally developed analysis and approaches can be added to expand a clinical decision support system and thus highlight how a comprehensive system can be globally developed with collaborators. This presentation will cover example scenarios from the CDS ConOps and the method to derive them. One example scenario will be CDSS alerting an increased kidney stone risk during a mission, with diagnosis and treatment options provided during the intervention.

clinical decision support↗

Clinical Decision Support - Concepts of Operation

We are entering a new era in space exploration to return to the moon and explore Mars. Crew members operating independently during long duration space exploration missions will require a clinical decision support system (CDSS) to increase autonomy by augmenting their knowledge, skills and abilities in different scenarios. Significant changes to in-flight and habitat medical care due to constraints on mass, volume, power, crew time and medical evacuation capabilities are needed to increase crew autonomy and self-reliance in decision making and task performance. The Exploration Medical Capability (ExMC) Element of the Human Research Program (HRP) pushes the boundary of space medical systems to advance the care of astronauts on future exploration missions beyond low Earth orbit by identifying and testing next-generation medical care and crew health maintenance technologies. Clinical decision support (CDS) presents knowledge and data in a context aware manner to augment a crew members’ knowledge, skills and abilities during the process of observation, orientation, decisions and action. A comprehensive crew health and performance CDSS is required to augment crew capability and will be used in different scenarios for several reasons. In general, the CDSS’s role is to assist the crew in prevention, detection, diagnosis and treatment of crew health and performance related conditions that may arise in exploration spaceflight. For example, CDSS would assist a high acuity scenario such as a heart attack by supplying clear instructions, vital signs and treatment reminders. A lower severity scenario such as kidney stone risk could interface to vehicle systems and display more complex predictive data during a diagnosis. A CDSS needs to contribute to successful missions by maintaining a high performing crew who can potentially exhibit countless medical conditions related to derangements from the space environment (sleep, cognition, nutrition and exercise) as well as conditions intrinsic to humans anywhere. While supporting the crew’s ability to make sound clinical decisions is desirable in any mission, it is essential for exploration missions with significant communication delays, no evacuation capability, and extended exposure to the flight environment. Such missions correspond with medical Level of Care V (LOC V), the highest level specified in NASA-STD-3001. The project focuses on CDS implementation research to derive requirements for LOC V, where the need for increased autonomy results in new practices and the inclusion of non-clinical data, such as vehicle environmental measures and physical exercise results, from other human and vehicle domains and advanced analytics. The CDS project describes how the CDSS is intended to be used by defining concepts of operations (ConOps). The process to derive ConOps focuses on increased autonomy that reduces the likelihood and consequences of accepted medical conditions. These crew health and performance inputs are grouped by common datasets and analysis models. Use cases are derived to research new clinical scenarios, architectural development and workflows. Implementation research is conducted with protypes to inform assumptions and derive requirements. The project also establishes how externally developed analysis and approaches can be added to expand a clinical decision support system and thus highlight how a comprehensive system can be globally developed with collaborators. This presentation will cover example scenarios from the CDS ConOps and the method to derive them. One example scenario will be CDSS alerting an increased kidney stone risk during a mission, with diagnosis and treatment options provided during the intervention.

clinical decision support↗

Telerobotics - Display, control, and communication problems

An experimental telerobotics simulation is described suitable for studying human operator (HO) performance. Simple manipulator pick-and-place and tracking tasks allowed quantitative comparison of a number of calligraphic display viewing conditions. An enhanced perspective display was effective with a reference line from target to base, with or without a complex three-dimensional grid framing the view. This was true especially if geometrical display parameters such as azimuth and elevation were arranged to be near optimal. Quantitative comparisons were made possible, utilizing control performance measures such as root mean square error. There was a distinct preference for controlling the manipulator in end-effector Cartesian space for the primitive pick-and-place task, rather than controlling joint angles and then, via direct kinematis, the end-effector position. An introduced communication delay was found to produce decrease in performance. In considerable part, this difficulty could be compensated for by preview control information. The fact that neurological control of normal human movement contains a sampled data period of 0.2 s may relate to this robustness of HO control to delay.

Stark, Lawrence↗

Manual Crew Override of Vehicle Landings Following G-Transitions

BACKGROUND Manual control during exploration spaceflight consists of both planned automated supervisory control and unplanned crew override. This crew override capability is critical to enable overall mission success during landing contingencies. However, the introduction of manual override capabilities must be implemented to enable crews to mitigate risks introduced by human error. Adaptive changes in the sensorimotor system can manifest during g-transitions as spatial disorientation. While training and landing aids enable successful landing through disorientation, these adaptive changes may increase cognitive demand that needs to be accounted for in the manual control strategy. It is important to characterize these effects as soon as possible following the G-transition to develop appropriate countermeasures. METHODS In this study, we will examine operational piloting tasks following International Space Station (ISS) missions in a simulated lunar landing using a six-degree-of-freedom (6DOF) motion base. The motion-based simulation will be implemented in our laboratory at the Johnson Space Center (JSC) and will be available within hours following the return from commercial crew landings. The primary goals of this study are (1) to understand the impact of spaceflight on crew ability to perform manual crew override tasks, (2) to examine how adaptive changes in vestibular and cognitive function relate to changes in manual crew override proficiency, and (3) compare performance during late “just-in-time” on-board training with early post-flight crew performance. The impact of spaceflight on piloting capability will be assessed from pre- versus post-flight changes in crewmembers assigned to either short duration (< 30 day) or long duration (~6- month) missions to the International Space Station (ISS). Individual differences in post-flight vestibular and cognitive changes include motion sickness reports, measures of tilt motion perception accuracy and precision, and dual-task tracking. During the 6DOF lunar simulation, the crew will manually takeover attitude and rate-of-descent to the nominal or re-designated landing aim point during the approach phase. The outcome measures for the lunar crew override tasks will be the percent time maintaining actual vehicle states, e.g., attitude and rate-of-descent, within recommended guidance during the landing approach, number and maximum deviation outside limits, and root mean square error (RMSE). Given that “just-in-time” (JIT) training is an operational expectation for the Human Landing System (HLS) program, all participants will perform late inflight JIT training for each manual crew override task in which they will participate. Crew proficiency will be captured inflight during JIT training that will be implemented on a laptop with hand controllers to allow the crewmember to practice the landing task procedures like the approach implemented for JIT training with Shuttle landing and ISS telerobotic tasks. COUNTERMEASURE UPDATES The lunar lander simulation has been implemented onto a two-laptop display system where subjects select from alternative landing points, based upon avoiding hazards that the on-board system identifies during the landing. The subject makes inputs using a rotational hand controller (i.e., joystick) and a translational hand controller, which are processed by simulated vehicle dynamics to update the vehicle attitude and rate of descent. Subjects will utilize a combination of flight, situation, and status displays to monitor the state of the simulated vehicle. The simulation exports tilt and translation movements to a 6DOF motion base synced to visual movements and provides representative vestibular cues to the subject while performing the task inside an enclosed cabin featuring a simulated lunar out-the-window view and a heads-down lander cockpit view. RELEVANCE This project will deliver an operational demonstration of crew override capability following spaceflight and identify potential deficits that may require remediation. Comparison of individual vestibular and cognitive changes with crew override performance will help better characterize the manual control risks associated with sensorimotor alterations. The inclusion of “just-in-time” on-board training will ensure we are characterizing changes in override proficiency with this expected countermeasure in place. ACKNOWLEDGEMENTS: The authors acknowledge contributions from Draper, HLS Joint Test Panel, Crew HLS Interfaces for Piloting Working Group, and Dynamic Skills Trainer (DST) Lab toward the development of the lunar landing simulation. This project is funded by the Human Health Countermeasures Element.

Austin M Bollinger↗

Evaluation of Markerless Motion Capture for Monitoring Sensorimotor Performance

BACKGROUND Astronauts returning from long-duration exposure to microgravity frequently exhibit alterations in sensorimotor function leading to postural imbalance, impaired locomotion, and operational challenges to manual control. Mission duration and individual responses often influence both the severity of performance decrements and the variability in adaptation timelines. Postflight disruptions during functional tasks are often detected through body-worn inertial measurement unit (IMU) devices. While IMU sensors are relatively compact, the long-term wear may lead to discomfort, displacement of the sensors on the body, and restrictions in movement or crew behavior. Although IMU data offers valuable insights from a research standpoint, interpreting changes in pre- and post-flight measures can be difficult for crew support personnel beyond the research domain, which can hinder the application for medical assessments and rehabilitation. Finally, the availability of inertial sensors in-flight is limited. There is a need for unobtrusive monitoring tools to improve our ability to monitor adaptation following gravitational transitions in various postflight evaluations and rehabilitation settings. Markerless motion capture (MMC) is an evolving unobtrusive technology that builds upon decades of research with marker-based motion capture systems to provide 3D human pose estimation from multiple synchronized 2D camera views using deep learning algorithms. Markerless technology can revolutionize how data is captured pre- and post-flight and potentially in-flight during intravehicular activity by enabling pose estimation of multiple crew members from onboard camera hardware. METHODS The following presents the initial evaluation of a state-of-the-art commercial-off-the-shelf MMC system, Theia Markerless, compared to IMU devices during various ground-based functional tasks and environmental conditions. The featured functional tasks include assessments from Human Research Program (HRP) funded studies such as Sensorimotor Standard Measures and Sensorimotor Assessments. Synchronous data collected using both motion capture and IMUs are analyzed for six male and female subjects of varying anthropometry. The analysis includes limited assessments of clothing, capture volume configurations, and the tool's sensitivity to detecting performance changes after a spaceflight analog centrifuge exposure. The development of visualization tools to enhance the application of the pose estimation output is also presented. RESULTS Initial results demonstrate comparable root mean square error (RMSE) to existing literature evaluating markerless and marker-based motion capture systems. Considering the relative functional range of motion of the cervical spine, normalized error values for the markerless system’s accuracy of the head was 0.032 in pitch, 0.025 in roll, and 0.018 in yaw plane of motion across a subset of functional tasks. The raw RMSE values were 3.49, 2.25, and 2.81 degrees respectively. For the torso, results suggest normalized errors of 0.469 in pitch, 0.191 in roll, and 0.307 in yaw planes of motion and raw RMSE values of 3.52, 1.53, and 3.07 degrees respectively. The data suggests the functional demands of a particular task influences the estimation accuracy of the MMC system where more dynamic motion and cases where subjects are not upright may introduce diminished tracking accuracy. DISCUSSION The following work lays the foundation for future implementations leveraging markerless motion capture to assess the time course of recovery and provide insight for rehabilitation protocols to enhance crew readiness for the resumption of daily activities. These tools offer effective methods for anonymizing sensitive crew data, facilitating numerous applications across research, medical, and rehabilitation groups. Collaborations with the Anthropometry and Biomechanics Facility will provide further comparisons of the Markerless system to a marker-based system. ACKNOWLEDGEMENT</ This work is supported by NASA’s Exploration Systems Development Mission Directorate Mars Campaign Office Crew Health Countermeasures.

Hannah M. Weiss↗

Measurement of joint kinematics using a conventional clinical single-perspective flat-panel radiography system

Purpose: The ability to accurately measure joint kinematics is an important tool in studying both normal joint function and pathologies associated with injury and disease. The purpose of this study is to evaluate the efficacy, accuracy, precision, and clinical safety of measuring 3D joint motion using a conventional flat-panel radiography system prior to its application in an in vivo study. Methods: An automated, image-based tracking algorithm was implemented to measure the three-dimensional pose of a sparse object from a two-dimensional radiographic projection. The algorithm was tested to determine its efficiency and failure rate, defined as the number of image frames where automated tracking failed, or required user intervention. The accuracy and precision of measuring three-dimensional motion were assessed using a robotic controlled, tibiofemoral knee phantom programmed to mimic a subject with a total knee replacement performing a stair ascent activity. Accuracy was assessed by comparing the measurements of the single-plane radiographic tracking technique to those of an optical tracking system, and quantified by the measurement discrepancy between the two systems using the Bland-Altman technique. Precision was assessed through a series of repeated measurements of the tibiofemoral kinematics, and was quantified using the across-trial deviations of the repeated kinematic measurements. The safety of the imaging procedure was assessed by measuring the effective dose of ionizing radiation associated with the x-ray exposures, and analyzing its relative risk to a human subject. Results: The automated tracking algorithm displayed a failure rate of 2% and achieved an average computational throughput of 8 image frames/s. Mean differences between the radiographic and optical measurements for translations and rotations were less than 0.08 mm and 0.07 Degree-Sign in-plane, and 0.24 mm and 0.6 Degree-Sign out-of-plane. The repeatability of kinematics measurements performed using the radiographic tracking technique was better than {+-}0.09 mm and 0.12 Degree-Sign in-plane, and {+-}0.70 mm and {+-}0.07 Degree-Sign out-of-plane. The effective dose associated with the imaging protocol used was 15 {mu}Sv for 10 s of radiographic cine acquisition. Conclusions: This study demonstrates the ability to accurately measure knee-joint kinematics using a single-plane radiographic measurement technique. The measurement technique can be easily implemented at most clinical centers equipped with a modern-day radiographic x-ray system. The dose of ionizing radiation associated with the image acquisition represents a minimal risk to any subjects undergoing the examination.

60 APPLIED LIFE SCIENCES↗

MO-E-17A-03: Monte Carlo CT Dose Calculation: A Comparison Between Experiment and Simulation Using ARCHER-CT

Purpose: To compare the CT doses derived from the experiments and GPU-based Monte Carlo (MC) simulations, using a human cadaver and ATOM phantom. Methods: The cadaver of an 88-year old male and the ATOM phantom were scanned by a GE LightSpeed Pro 16 MDCT. For the cadaver study, the Thimble chambers (Model 10×5−0.6CT and 10×6−0.6CT) were used to measure the absorbed dose in different deep and superficial organs. Whole-body scans were first performed to construct a complete image database for MC simulations. Abdomen/pelvis helical scans were then conducted using 120/100 kVps, 300 mAs and a pitch factor of 1.375:1. For the ATOM phantom study, the OSL dosimeters were used and helical scans were performed using 120 kVp and x, y, z tube current modulation (TCM). For the MC simulations, sufficient particles were run in both cases such that the statistical errors of the results by ARCHER-CT were limited to 1%. Results: For the human cadaver scan, the doses to the stomach, liver, colon, left kidney, pancreas and urinary bladder were compared. The difference between experiments and simulations was within 19% for the 120 kVp and 25% for the 100 kVp. For the ATOM phantom scan, the doses to the lung, thyroid, esophagus, heart, stomach, liver, spleen, kidneys and thymus were compared. The difference was 39.2% for the esophagus, and within 16% for all other organs. Conclusion: In this study the experimental and simulated CT doses were compared. Their difference is primarily attributed to the systematic errors of the MC simulations, including the accuracy of the bowtie filter modeling, and the algorithm to generate voxelized phantom from DICOM images. The experimental error is considered small and may arise from the dosimeters. R01 grant (R01EB015478) from National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids

A flexible and wearable microsensor array is described for simultaneous multiplexed monitoring of heavy metals in human body fluids. Zn, Cd, Pb, Cu, and Hg ions are chosen as target analytes for detection via electrochemical square wave anodic stripping voltammetry (SWASV) on Au and Bi microelectrodes. The oxidation peaks of these metals are calibrated and compensated by incorporating a skin temperature sensor. High selectivity, repeatability, and flexibility of the sensor arrays are presented. Human sweat and urine samples are collected for heavy metal analysis, and measured results from the microsensors are validated through inductively coupled plasma mass spectrometry (ICP-MS). Real-time on-body evaluation of heavy metal (e.g., zinc and copper) levels in sweat of human subjects by cycling is performed to examine the change in concentrations with time. Finally, this platform is anticipated to provide insightful information about an individual's health state such as heavy metal exposure and aid the related clinical investigations.

47 OTHER INSTRUMENTATION↗