Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating and cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Estimating outflow masses and velocities in merger simulations: Impact of r -process heating and neutrino cooling

Here, the determination of the mass, composition, and geometry of matter outflows in black hole-neutron star and neutron star-neutron star binaries is crucial to current efforts to model kilonovae and to understand the role of neutron star merger in r-process nucleosynthesis. In this manuscript, we review the simple criteria currently used in merger simulations to determine whether matter is unbound and what the asymptotic velocity of ejected material will be. We then show that properly accounting for both heating and cooling during r-process nucleosynthesis is important to accurately predict the mass and kinetic energy of the outflows. These processes are also likely to be crucial to predict the fall-back timescale of any bound ejecta. We derive a model for the asymptotic velocity of unbound matter and binding energy of bound matter that accounts for both of these effects and that can easily be implemented in merger simulations. We show, however, that the detailed velocity distribution and geometry of the outflows can currently only be captured by full three-dimensional fluid simulations of the outflows, as nonlocal effect ignored by the simple criteria used in merger simulations cannot be safely neglected when modeling these effects. Finally, we propose the introduction of simple source terms in the fluid equations to approximately account for heating/cooling from r-process nucleosynthesis in future seconds-long three-dimensional simulations of merger remnants, without the explicit inclusion of out-of-nuclear statistical equilibrium reactions in the simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

University of South Alabama: Evaluation of Using Heat Pipes to Cool Adsorbent Beds in AC-TSAC Systems

This report details the results of the research and work of undergraduate students at the University of South Alabama across the 2023-24 academic year. These results examine the use of heat pipes for air revitalization in space exploration and habitation units. The current mechanism for removing carbon dioxide in the International Space Station is the Carbon Dioxide Removal Assembly (CDRA), which involves 2 cooperating adsorbent beds that continuously adsorb and desorb carbon dioxide. Recently, NASA has investigated the use of air-cooled temperature swing adsorption compressors (AC-TSAC) to provide both adsorption and compression of CO 2 . To effectively adsorb and desorb CO 2 , the beds must operate across a range of temperatures and require efficient heating and cooling to reach the necessary operating temperatures. Heat pipes, which are fluid-filled rods that use a wicking mechanism to transfer heat, may provide one alternative approach to moving heat into and out of adsorption beds. To test the cooling efficiency of packed beds equipped with heat pipes, a packed bed was constructed to examine the amount of heat transferred with this technology. In addition to a physical apparatus, a model was built using COMSOL Multiphysics® to obtain an initial assessment of the effectiveness of using heat pipes for temperature control in porous adsorption beds.

T. Grant Glover↗

Liquid spray cooling of a heated surface

The lowest surface temperature possible for the existance of spray evaporative cooling is determined experimentally to be a linear function of the impinging spray mass flux. A conduction-controlled analytical model of droplet evaporation gives fairly good agreement with experimental measurements at atmospheric pressure. At reduced pressures droplet evaporation rates are decreased significantly such that an optimum operating pressure exists for each desired surface heat flux. The initiation of the 'Leidenfrost state' provides the upper surface temperature bound for spray evaporative cooling.

Grissom, W. M.↗

System and method for cooling using a heat exchanger having a membrane

A heat exchanger that includes a membrane of graphene oxide is disclosed, as is a heat exchange system employing such a heat exchanger. The heat exchanger permits the use of water from non-traditional sources, such as waste water, brackish and sea water, in a cooling loop. Clean water and sensible heat permeate through the membrane, simultaneously cooling and purifying water in the cooling loop.

42 ENGINEERING↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat transfer and film cooling following injection through inclined circular tubes

Film cooling effectiveness and heat transfer are measured downstream of injection through discrete holes into a turbulent mainstream boundary layer. Air is injected through both a single hole and a row of holes spaced at three-diameter intervals and inclined at an angle of 35 deg to the main flow. There is little difference between the heat transfer coefficient with blowing and without blowing at low blowing rates (mass flux ratios). In fact, at low blowing rates, injection is found to decrease somewhat the heat transfer coefficient from that measured without blowing. As the mass flux ratio increases past unity, the heat transfer coefficient increases, especially with injection through a row of holes. The peak heat transfer is usually found at the edge of the spreading jets (i.e., between two holes). At a blowing rate near two, the lateral average of the heat transfer is as much as 27 percent higher than the heat transfer with no blowing. The increase in heat transfer is attributed to the interaction between the jets and the free stream, causing high levels of turbulence.

Eriksen, V. L.↗

Thermal design for areas of interference heating on actively cooled hypersonic aircraft

Numerous actively cooled panel design alternatives for application in regions on high speed aircraft that are subject to interference heating effects were studied. Candidate design concepts were evaluated using mass, producibility, reliability and inspectability/maintainability as figures of merit. Three design approaches were identified as superior within certain regimes of the matrix of design heating conditions considered. Only minor modifications to basic actively cooled panel design are required to withstand minor interference heating effects. Designs incorporating internally finned coolant tubes to augment heat transfer are recommended for moderate design heating conditions. At severe heating conditions, an insulated panel concept is required.

Herring, R. L.↗

Design of Refractory Metal Heat Pipe Life Test Environment Chamber, Cooling System, and Radio Frequency Heating System

A series of 16 Mo-44.5%Re alloy/sodium heat pipes will be experimentally tested to examine heat pipe aging. To support this evaluation, an environmental test chamber and a number of auxiliary subsystems are required. These subsystems include radio frequency (RF) power supplies/inductive coils, recirculation water coolant loops, and chamber gas conditioning. The heat pipes will be grouped, based on like power and gas mixture requirements, into three clusters of five units each, configured in a pentagonal arrangement. The highest powered heat pipe will be tested separately. Test chamber atmospheric purity is targeted at <0.3 ppb oxygen at an approximate operating pressure of 76 torr (.1.5 psia), maintained by active purification (oxygen level is comparable to a 10(exp -6) torr environment). Treated water will be used in two independent cooling circuits to remove .85 kW. One circuit will service the RF hardware while the other will maintain the heat pipe calorimetry. Initial procedures for the startup and operation of support systems have been identified. Each of these subsystems is outfitted with a variety of instrumentation, integrated with distributed real-time controllers and computers. A local area network provides communication between all devices. This data and control network continuously monitors the health of the test hardware, providing warning indicators followed by automatic shutdown should potentially damaging conditions develop. During hardware construction, a number of checkout tests.many making use of stainless steel prototype heat pipes that are already fabricated.will be required to verify operation.

Martin, J. J.↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

Greenleaf, J. E.↗

Shock Heating and Subsequent Cooling of Basaltic Shergottites: The Cases for QUE94201 and Dhofar 378

Shock metamorphism is one of the most fundamental processes in the history of Martian meteorites. Especially, shergottites experienced strong shock effects (>30 GPa) most likely when they were ejected from Mars. "Maskelynitization" of plagioclase and formation of shock melts are major effects due to this severe shock. QUE94201 (QUE) and Dhofar 378 (DHO) are basaltic shergottites that are mainly composed of pyroxene and plagioclase glass. These two shergottites suffered severe shock, which generated abundant impact melt and vesiculated flow textures. In spite of similar degrees of shock between two meteorites, they are distinct in several mineralogical aspects. In this abstract, we discuss their differences to understand differences in their shock heating and subsequent cooling histories.

Mikouchi, T.↗

An advanced membrane-based HMX model and its application in utilizing sensible and latent heat removed in space cooling

This paper presents a comprehensive simulation model for advanced membrane-based heat and mass exchanger (HMX) components which account for three separate fluid streams with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl and ionic liquid (IL)). Preliminary model validation is presented using data from a laboratory prototype absorber. The paper also presents implementation of the model into a sorption system modeling platform and analyzes potential benefit analysis of the HMX component in utilizing the sensible and latent heat removed in space cooling to heat water. The developed model and codes are expected to enable detailed optimization studies and identify novel configurations for the three-fluid HMX maximum performance and cost effectiveness.

Gao, Zhiming↗

Ruggedness Evaluation of ASTM International Standard Test Methods for Shape Memory Materials: E3098 Standard Test Method for Mechanical Uniaxial Pre-strain and Thermal Free Recovery of Shape Memory Alloys

This paper evaluates the ruggedness testing of the recently released ASTM International E3098 Standard Test Method for Mechanical Uniaxial Pre-strain and Thermal Free Recovery of Shape Memory Alloys. The ruggedness experiment was designed with eight runs in two replicates, consisting of seven factors: strain rate (ė), heating and cooling rates (Ṫ heat and Ṫ cool , respectively), upper and lower cycle temperatures (UCT and LCT, respectively), hold time (t hold ), and minimum load (F min ) imparted on the samples. The results indicate that the strain rate factor had no effect on any result variable, whereas the minimum load factor had a large effect on several result variables including the austenite start and martensite finish temperatures as well as most of the strain measurements from the thermal cycle. The lower cycle temperature factor had a large effect on the stress at maximum strain during pre-straining (e i ), denoted by S i , at ~7.2 MPa, as well as the A f , at 5.47 °C. Closely following the LCT effect, Ṫ heat was found to have a large effect on the austenite start temperature (A s ), at a value of ~2.72 °C. The testing methodology, analysis techniques, and resulting conclusions on the ruggedness of the test method are presented.

Shape memory alloys↗

The Effect of Cooling Passage Aspect Ratio on Curvature Heat Transfer Enhancement

A series of electrically heated tube experiments was performed to investigate the effect of high aspect ratio on curvature heat transfer enhancement in uniformly heated rectangular cooling passages. Three hardware geometries were tested: a baseline straight aspect ratio 10 tube, an aspect ratio 1 (square) tube with a 45 deg. curve, and an aspect ratio 10 tube with a 45 deg. curve. Gaseous nitrogen with the following properties was used as the coolant: ambient inlet temperature, pressures to 8.3 MPa, wall-to-bulk temperature ratios less than two, and Reynolds numbers based on hydraulic diameter ranging from 250,000 to 1,600,000. The measured curvature enhancement factors were compared to values predicted by three previously published models which had been developed for low aspect ratio tubes. The models were shown to be valid for the high aspect ratio tube as well the low aspect ratio tube, indicating that aspect ratio had little impact on the curvature heat transfer enhancement in these tests.

Meyer, Michael L.↗

Electric motor cooling with oscillating heat pipes

A stator and a motor including a stator. The stator includes a stator hub, a plurality of stator teeth extending from the stator hub that define a stator slot having a stator slot base, at least one winding disposed in the stator slot, and one or more oscillating heat pipes disposed at least partially in the at least one winding. The at least one winding is held apart from the stator slot base so that a cooling channel is defined between an inner winding portion of the at least one winding and a portion of the one or more oscillating heat pipes is disposed in the channel so cooling fluid can be passed between the stator slot base and the inner winding portion to cool the inner winding portion via at least operation of the one or more oscillating heat pipes.

Alahyari, Abbas A.↗

Ruggedness Evaluation of ASTM International Standard Test Methods for Shape Memory Materials: E3097 Standard Test Method for Mechanical Uniaxial Constant Force Thermal Cycling of Shape Memory Alloys

This paper evaluates the ruggedness testing of the newly released ASTM International E3097 Standard Test Method for Mechanical Uniaxial Constant Force Thermal Cycling of Shape Memory Alloys. The ruggedness experiment was designed with eight runs in two replicates, consisting of seven factors of strain rate (ė), heating and cooling rates (Ṫ(heat) and Ṫ(cool), respectively), upper and lower cycle temperatures (UCT and LCT, respectively), hold time (thold), and minimum load (Fmin) imparted on the samples. The results indicate that the hold time factor had no effect on any result variable. The minimum load factor, alternatively, had the greatest effect on several result variables, with the greatest influence on the strains at martensite start and finish (strain variation ~0.1 percent), and the strains at the upper and lower cycle temperatures (strain variation of 0.14 percent). The UCT was found to have a large effect on the austenite and martensite finish tangent line and data intersect, denoted by Af* and Mf*, by ~17 and 4 °C, respectively. The testing methodology, analysis techniques, and resulting conclusions on the ruggedness of the test methods are presented.

shape memory alloy↗

Integrated cooling (i-Cool) textile of heat conduction and sweat transportation for personal perspiration management

Perspiration evaporation plays an indispensable role in human body heat dissipation. However, conventional textiles tend to focus on sweat removal and pay little attention to the basic thermoregulation function of sweat, showing limited evaporation ability and cooling efficiency in moderate/profuse perspiration scenarios. Here, we propose an integrated cooling (i-Cool) textile with unique functional structure design for personal perspiration management. By integrating heat conductive pathways and water transport channels decently, i-Cool exhibits enhanced evaporation ability and high sweat evaporative cooling efficiency, not merely liquid sweat wicking function. In the steady-state evaporation test, compared to cotton, up to over 100% reduction in water mass gain ratio, and 3 times higher skin power density increment for every unit of sweat evaporation are demonstrated. Besides, i-Cool shows about 3 °C cooling effect with greatly reduced sweat consumption than cotton in the artificial sweating skin test. The practical application feasibility of i-Cool design principles is well validated based on commercial fabrics. Owing to its exceptional personal perspiration management performance, we expect the i-Cool concept can provide promising design guidelines for next-generation perspiration management textiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗