Single Primary Heat Extraction and Removal Emulator (SPHERE) Long Duration Testing

For heat-pipe cooled microreactor development, it is essential to understand the characteristics of heat pipes and how they function under a wide range of operating conditions. An important process for heat-pipe cooled microreactor development is the passive heat removal and how the performance may change over long periods of time. Increased experimental data provides additional information to assess the operational lifetime of alkali metal heat pipes. Idaho National Laboratory has completed testing over a long duration of a high-performance sodium filled heat pipe while monitoring axial temperature profile, power supplied by the heaters, and heat removed by a gas-gap calorimeter. The results from this testing can aid in heat pipe validation efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Exchanger Intensification Through Powder Processing and Enhanced Design (HIPPED)

High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.

30 DIRECT ENERGY CONVERSION↗

Surface heat flux and its association with the MJO in the tropical western Pacific using ARM observations

The Madden-Julian oscillation (MJO) is a major atmospheric phenomenon in the tropics that moves eastward every 20 to 100 days. It brings heavy rain and strong winds, influencing extreme weather events far beyond the tropics – including flooding, hurricanes, tornadoes and heavy snow in the United States. Therefore, an improved understanding of the MJO is critical for enhancing weather forecasts and supporting better decision-making for communities, emergency managers, and the private sector. Past studies, based on short-term observations or long-term model data, have emphasized the dominant role of atmospheric humidity in driving the MJO. Our research, using long-term observations (2000-2014) from three U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) sites in the tropical western Pacific (Manus, Nauru, and Darwin) confirms those past findings. However, we also show that atmospheric temperature, especially in the mid and upper troposphere, also plays a key role in the MJO’s evolution from its quiet (suppressed) to convective (active) phase. These findings provide valuable insights into how the MJO evolves and may help evaluate and improve weather and climate models. Our study also examined how the exchange of heat between the Earth's surface and the atmosphere, called surface heat flux, interacts with the MJO. This flux includes components such as latent heat (related to evaporation), sensible heat (related to temperature difference between surface and atmosphere), and radiation. We found that modulation in MJO convection is well connected to surface heat flux over the tropical western Pacific. One surface heat flux component often overlooked is the sensible heat flux due to precipitation (Q P ). Since falling raindrops are typically cooler than the land or ocean surface, they can cool the surface and affect local weather. To test the impact of Q P on convection during MJO, we incorporated it into a weather model, and ran simulations for two periods: April 2009 (when the MJO was active) and June 2006 (when it was not). Including Q P reduced errors in simulating the daily peak of rainfall—by 83% during the strong MJO and 23% during the inactive phase. It also improved the timing of peak daily rainfall and reduced the overall precipitation error by about 10%. These improvements were especially noticeable during periods of heavy rainfall. Our results suggest that even small heat exchanges from rainfall can play a significant role in shaping local weather. Accounting for these effects, particularly in regions like the tropical islands, can lead to more accurate simulations of the MJO-associated precipitation.

54 ENVIRONMENTAL SCIENCES↗

Estimation of Corn Latent Heat Flux from High Resolution Thermal Imagery

Crop evapotranspiration (ET), which is directly related to latent heat flux, is also a key indicator in determining the water status of crops. In order to estimate the latent heat flux, two-source energy balance (TSEB) models have been developed for thermal imagery from satellite platforms. However, because of the coarse resolution of thermal sensors on the satellite, distinguishing soil and vegetation is difficult which complicates the calculation process and introduces errors in latent heat estimates. In this research, high-resolution thermal datasets (0.05 m) and corresponding RGB datasets (0.03 m) were used for calculating crop latent heat flux using an adapted TSEB model. The RGB datasets were used for supervised classification of soil and vegetation, and the classification results were then used to filter the thermal mosaics to separate vegetation and soil temperatures. The vegetation temperature is used for calculating latent heat flux and the results are validated against the ground reference measurements of latent heat using a handheld porometer. The objective of this research is to introduce a workflow including an adapted TSEB model which is customized for high resolution thermal images from unmanned aircraft systems (UAS) to estimate the latent heat flux of row crops in agricultural fields. Nine dates of data collection in 2018 and 2020 have been evaluated and the root mean square error (RMSE) varies between 16 to 106 W/m2 depending on the days after planting (DAP) and the time of measurement for each day. The results indicate that the workflow introduced here is able to provide estimates of instantaneous latent heat flux (evapotranspiration) measurements for row crops in agricultural fields which will enable people to make reliable decisions related to irrigation scheduling.

54 ENVIRONMENTAL SCIENCES↗

Hybrid Solar Heat Generation Modelling and Cases: Preprint

Renewable thermal energy systems (RTES) harness renewable energy sources to provide services for space heating and cooling, district heating, domestic hot water, and industrial process heat (IPH). The use of low-pressure steam generated by the combustion of fossil fuels is common today to provide process heat for industrial facilities. Solar IPH (SIPH) technologies could economically replace the steam or heat needs at many industrial sites by providing high-temperature pressurized hot water, a heat transfer fluid (HTF) such as synthetic-oil, or direct steam (Kurup and Turchi, 2015). RTES could be hybridized with technology options or combined with the existing heat supply (e.g. fuels), to give options for targeted IPH application and the reduction of fuel consumption. This work has tested hybrid system modelling approaches. Initial results show when a natural gas (NG) burner that feeds an IPH application of 300°C, has both air and NG streams pre-heated with a solar field/RTES exit temperature of 180°C (via an HTF), a 13% NG offset is possible. NG offsets reach up to 26%, when the RTES exit temperatures are at 300°C for a given annual capacity factor of 24%. This can be even higher with addition of thermal energy storage (TES).

43 PARTICLE ACCELERATORS↗

Energy Model of an Air Source Heat Pump to Explore Performance Improvements under Cold Conditions: A Python Framework: Preprint

Replacing combustion appliances with heat pumps can be part of a strategy to electrify buildings. When their electricity is supplied by renewables, the adoption of heat pumps for space heating may help curb the carbon dioxide emissions inherent to traditional heating systems that burn natural gas or coal. When operating in very cold climates, however, heat pump performance deteriorates, sometimes requiring backup heating supplied by electric resistances or other sources to continue to function. To avoid the use of electric resistances, complementary technologies, like thermal energy storage, solar collectors, or alternative refrigerants, have been explored in recent years. In this study, we present an open-source Python-based numerical model developed to evaluate the annual hourly performance of an air source heat pump (ASHP) operating in the USA. Simulation results include coefficient of performance and heating capacity. The model, validated with experimental results, will be employed in the future to investigate the feasibility of integrating thermal energy storage and other technologies into ASHPs operating in cold climates.

cold climate↗

Heating effects on pyrogenic organic matter mass loss and temperature in a sand matrix in a lab setting from 2022

This dataset contains data associated with the preprint “A laboratory method for simulating the effects of subsequent fires on pyrogenic organic matter at different exposure depths in a sand matrix” (https://doi.org/10.1101/2024.07.30.605814), which has been accepted for publication in the International Journal of Wildland Fire. The dataset was generated to investigate the effects of subsequent fires on preexisting pyrogenic organic matter (PyOM) at different soil depths. Specifically, we designed a laboratory method to simulate soil heating from above, applying realistic heat flux profiles (High, Low, Control) derived from jack pine (Pinus banksiana Lamb.) log burns. Using a cone calorimeter, these profiles were applied to buried jack pine PyOM (produced at 350°C) in a sand matrix pyrocosm to examine PyOM mass loss at different depths (surface, 1 cm, 5 cm). Each treatment (e.g., High heat flux at 1 cm depth) was applied once to five replicates in a pyrocosm.The dataset includes mass loss fraction of PyOM and time-series temperature profiles (measured with type K thermocouples). Additionally, calibration datasets for high and low heat flux profiles are provided, including programmed heat flux profile data and three sets of calibration results. All datasets are in .csv format and were analyzed in R using code found at https://github.com/MengmengLuo/Reburning-pyrogenic-organic-matter-A-laboratory-method-for-dosing-dynamic-heat-fluxes-from-above. This dataset supports research on PyOM transformations during subsequent fires, and methodological advancements in simulating soil heating. It can be used to explore fire-induced PyOM alterations across different fire intensities and soil depths.

54 ENVIRONMENTAL SCIENCES↗

Dielectric Barrier Discharge Electrothermal Heating and Additive Manufacturing of Thermoset Parts

Additive manufacturing of thermosets requires a mechanism for solidifying deposited layers in order to prevent part collapse. To accomplish this, non‐equilibrium plasma is proposed for its ability to target, heat, and cure printed thermosetting resin. Non‐equilibrium plasmas have not been used for the curing of liquid thermoset composites, and so their impact on an uncured resin is unknown. Here this work investigates the mechanism through which dielectric barrier discharge (DBD) heats an epoxy/carbon nanotube (CNT) composite under atmospheric conditions. Plasma applied to resin surfaces is found to cause rapid heating, with heating rate controlled by adjusting the applied power. Heating is localized to within the top 0.5 mm of the sample surface and maximum temperature is found to depend on sample conductivity, indicating the heating reaction occurs through a combination of electron conduction and ion bombardment. Characterization of composites cured using plasma shows oxidation and roughening of the surface. Based on the heating and surface studies, several demonstrative prints are performed using in situ plasma curing. This work shows the potential of DBD plasma to rapidly heat liquid substrates and demonstrates how plasma curing expands the capability of existing direct ink write (DIW) printer technologies.

3D printing↗

Design, fabrication, simulation, and testing of additively manufactured lattice-based copper heat sinks

Here, this study investigates the potential advantages of lattice structure-based bound metal material extrusion (MEX) 3D printing for fabricating high-performance copper heat sinks. Copper powder-filled polymer filaments, with a copper content of > 90 wt.%, were developed specifically for the bound metal MEX 3D printing process. Three types of structures—planar, strut, and surface lattices—were 3D printed to facilitate efficient heat transfer pathways within the heat sinks. Subsequent post-processing steps, including polymer removal and sintering, were performed to achieve dense copper parts. Hot isostatic pressing was further employed to enhance the sintered density from 93 to 98%. Finite element analysis (FEA) simulations were conducted to assess the heat transfer efficiency of the designs, and heat transfer experiments were performed using a custom setup to validate the simulation results. Additionally, this research explores the use of extended hold times during pre-sintering and a reduced atmosphere to enhance the %IACS values (electrical conductivity) and thermal performance of the bound metal MEX 3D printed copper heat sinks. The investigation combines experimental analysis, including simulations and heat transfer experiments, to gain insights into the structure-material property relationships and optimize the thermal performance of the printed heat sinks.

Ajjarapu, Kameswara Pavan Kumar [Oak Ridge Nationa↗

Climate science to inform adaptation policy: Heat waves over India in the 1.5°C and 2°C warmer worlds

Developing a better scientific understanding of anthropogenic climate change and climate variability, especially the prediction/projection of climate futures with useful temporal and geographical resolution and quantified uncertainties, and using that knowledge to inform adaptation planning and action will become crucially important in the coming years. Generating such policy-relevant knowledge may be particularly important for developing countries such as India. It is with this backdrop that, in this paper, we analyze future heat waves in India by using observations and a large number of model simulations of historical, + 1.5 °C, and + 2.0 °C warmer worlds. In both the future scenarios, there is an increased probability of heat waves during June and July when the Indian monsoon is in full swing and humidity is high, which makes the heat events even more of a health risk. While the highest temperatures in heat waves may not increase much in future climates, the duration and areal extent of the heat waves will most likely increase, leading to the emergence of new heat wave-prone zones in India. The results indicate that the joint frequencies of the longest duration and large area events could be nearly threefold greater in the + 1.5 °C and fivefold greater in the + 2.0 °C future scenarios compared to historical simulations. Thus, overall, the study indicates a substantial increase in the risk of heat events that typically elicit warnings from forecasters. The likely widespread and persistent nature of heat wave events in the future, as revealed by this study, will require planning and adaptation measures beyond the short-term disaster planning frameworks currently in place. Exploring what these measures might look like is beyond the scope of this study, but it underlines the importance of developing climate knowledge with high temporal and geographical resolution capable of informing adaptation policy and planning.

+1.5 °C and +2.0 °C↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Comparison of microwave and conventional heating for CO 2 desorption from zeolite 13X

In this study, we investigate microwave irradiation as an alternative to conventional heating for temperature swing adsorption processes. The performance of microwave and conventional heating during sorbent regeneration was evaluated by measuring CO 2 desorption from zeolite 13X at different temperatures. Experimentally, a fixed bed of zeolite 13X was saturated by a 150 sccm flow of 15 % CO 2 at room temperature followed by sorbent regeneration under nitrogen at 55, 100, or 150 °C by applying either microwave irradiation or conventional heating. Microwaves reduced sorbent regeneration times by at least half compared to regeneration by conventional heating. Under conventional regeneration, desorption curves were resolved into two peaks representing physisorbed CO 2 (mass diffusion limited) at low temperature and bicoordinated CO 2 (thermally limited) with increasing temperature. Under microwave regeneration, only one desorption peak was observed suggesting that CO 2 desorption was limited by mass diffusion through the porous zeolite 13X structure, rather than by temperature. Depending on microwave power, apparent activation energy of the microwave-assisted regeneration was 15.8–18.1 kJ/mol, compared to 41.5 kJ/mol for conventional regeneration. The reduction in apparent activation energy is mainly attributed to selective microwave heating of CO 2 adsorption sites (Na + sites) resulting in greater steady state temperatures of Na + relative to framework atoms, suggesting greater heating efficiency due to microwaves compared to conventional heat transfer. Due to rapid cycling and efficient heat transfer to CO 2 sites on zeolite 13X, microwave regeneration is found to increase adsorption/desorption cycling productivity and potentially reduce the energy penalty of temperature swing capture.

54 ENVIRONMENTAL SCIENCES↗

Effect of homogenization heat treatment on the evolution of carbonitrides in powder bed fusion processed INCONEL 718

Inconel 718 fabricated using laser powder-bed fusion, contains precipitates in the as-built condition that can be coarsened by high-temperature heat treatments. In this study, two homogenization heat treatment regimens were applied to discern the impact of heat treatment conditions on the growth of complex M(C, N) carbonitrides. In the first heat treatment, the samples underwent heat treatment between 1050 °C and 1200 °C for 0.5 h. In the second heat treatment, the samples were held at a constant temperature of 1150 °C, with varied holding times from 0.5 h to 8 h. Heat treatments dissolved the unstable Laves phase, but the carbonitrides persisted in the structure regardless of temperature and duration. Changes in the compositions, lattice parameters, and sizes of M(C, N) carbonitrides were measured using transmission electron microscopy and high-energy synchrotron X-ray diffraction. The results show an Nb enrichment at carbonitrides while Nb loss at the matrix with increased homogenization temperature. The findings suggest the optimum heat treatment conditions to achieve a homogeneous structure and controlled carbonitride size are between 1000 and 1050 °C for up to 2 h.

IN178↗

Review of heat transfer enhancement techniques in two-phase flows for highly efficient and sustainable cooling

We show that two-phase internal flow is ubiquitous to many systems due to its ability to transfer large amounts of heat effectively. Recent advances motivated by sustainability have pushed towards augmenting the heat transfer between the tube and the two-phase working fluid. Augmenting heat transfer in two-phase flows enables process intensification, and compactness leading to reduced cost and material consumption. This review investigates the effect of heat transfer enhancement techniques on different fluids including R134a, R407C, R22, etc … The techniques are categorized into passive and active and focus on durable enhancement methods which do not include surface structuring or coating. Passive techniques utilize geometrical and surface modifications to induce better mixing. Several passive techniques are analyzed including fins, inserts, and more. In analyzing these techniques, the effect of changing geometric parameters is studied, and the limitations are highlighted. Further, active techniques that enable heat transfer enhancement through applying power are also investigated. Electrohydrodynamic approaches are analyzed and compared to passive techniques. Additionally, the implications of heat exchange enhancement in the context of global energy are discussed. An energy analysis discretized by the use sector is conducted, with an emphasis on predicting the future potential for renewable and sustainable development. Moreover, although active approaches provide the highest heat transfer enhancement, due to implementation difficulties, passive techniques are more frequently adopted. The review ends with discussion of next-generation heat exchangers which will rely more on additive manufacturing due to its flexibility and reduced cost per part as the technology matures.

Nusselt number↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observational Constraints on the Spatial Effect of Greenness and Canopy Cover on Urban Heat in a Major Midlatitude City

Abstract Urban heat stress is a critical issue, particularly in cities where dense infrastructure and limited green space exacerbate temperature extremes. This study investigates the impact of greenery (EVI2), canopy cover (CC), impervious cover (IC), and water bodies on heat index in Chicago using high‐resolution data from the Heat Watch campaign. We find that EVI2, CC and proximity to water body significantly reduce heat while IC increases heat, particularly in the afternoon when solar radiation is intense. Additionally, the effective radius that land cover impacts heat is smaller in the afternoon. The combined effect analysis indicates that enhancing total greenness, not just canopy cover, is the most effective strategy to reduce heat. This study underscores the importance of strategic vegetation management, highlighting the critical role of integrated approaches in reducing urban heat.

Lee, Jangho↗