Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mesoscale fractal whey protein particles derived from microscale linear-shaped protein assemblies (Part 1): Manufacturing method and particle characteristics

Whey protein isolates (WPI) are widely used in processed foods for their versatile functional properties. Modifying the structural properties of proteins by assembling them into mesoscale or microscale particles may improve their functionality and broaden their applications. This study aims to manufacture and characterize mesoscale whey protein particles (WPP) derived from WPI. Two types of WPP, WPP1 (0.05 mL/min) and WPP2 (0.25 mL/min), were prepared through a multistep approach involving liquid antisolvent (LAS) precipitation, heat treatment, and microfluidization. Liquid antisolvent precipitation was performed by injecting a 20% (wt/vol) WPI dispersion (pH 7) into an ethanol-glycerol mixture (75:25, vol/vol) under laminar flow, followed by heat treatment at 80°C for 20 min as a particle hardening step. This process produced stable fiber- and ribbon-shaped whey protein assemblies (WPA), which served as precursors to WPP. Subsequent microfluidization (150 MPa, 6 passages) reduced the size of WPA, yielding mesoscale WPP with irregular morphologies and a more uniform size distribution, as revealed by microscopy and dynamic light scattering. ζ-Potential and fluorescence labeling indicated higher surface charge and surface hydrophobicity of WPP compared with untreated WPI. The WPP showed internal mass fractal and surface fractal structures at larger length scales, analyzed using small-angle X-ray scattering. Fourier transform infrared spectroscopy demonstrated an increased fraction of intermolecular β-sheets in WPP, suggesting that hydrogen bonding contributed to their formation. Gel electrophoresis confirmed that disulfide bonds served as the primary cross-links stabilizing the WPP structure. Furthermore, turbidity measurements showed that WPP exhibited superior colloidal phase stability compared with untreated WPI and maintained high colloidal stability under both acidic and neutral pH conditions.

Antisolvent precipitation↗

SAS4A/SASSYS-1 Modeling Improvements for the Transition to Natural Circulation

SAS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over fifty years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. In recent years, SAS has undergone a number of improvements to enable improved safety analyses that meet end users’ modernized needs while complying with the current regulatory environment. Improvements made in versions 5.6 and 5.7 released within the last year include the development of anisotropic Reynolds number dependent loss coefficients throughout the core and heat transport systems, the ability to distinguish the transition friction factor from the fully developed laminar and turbulent friction factors, and timedependent direct coolant and wall heating for pipe-like elements in the heat transport systems. While it was possible to capture loss coefficients, friction factors, and heat transfer from an element to a heat sink within SAS in previous versions of the code, users were required to end the simulation and restart it to adjust the input to account for any significant changes to the values during the transient. With these improvements, users can better capture flow reversal, pump heating, and the transition from forced to natural circulation without being limited to constant orifice coefficients, constant heat sinks, or the need to restart the simulation and modify input. In order to demonstrate the application of these improvements, a loss of flow transient is simulated for the Advanced Burner Test Reactor (ABTR).

SAS4A/SASSYS-1↗

Optimizing Cornell’s future geothermal district heating performance through systems engineering and simulation

Cornell University’s intention to lower its carbon footprint has motivated this engineering evaluation of using low-temperature geothermal energy to supply heat to the campus district energy system. Optimal selection and operation of heat pumps can significantly improve system performance. To support this analysis, we model the quantitative relationships between heat pump configurations and source flow, supply and distribution temperatures, facility heating design options, output heat generation, and carbon abatement outcomes. A systems approach is used for analysis, troubleshooting, and improvement of the model. The result of this effort is a dynamic tool that appropriately responds to hourly thermal demand and communicates energy response for techno-economic analysis. Simulations indicate that a single well-pair in the local Basement Contact Zone reservoir can satisfy almost 68% of annual thermal demand at nearly 20 MWth average capacity while remaining financially competitive compared to conventional heating with levelized cost of heating (LCOH) as low as $4.55/MMBTU ($15.53/MWh th ). A direct-use scheme with heat pump augmentation provided more carbon abatement and 50 to 150% more annual heat supply than one without augmentation. Exploration of three and four well-pair scenarios prove the capability to achieve 50 MW th baseload heating capacity with competitive LCOH and significant carbon reductions.

15 GEOTHERMAL ENERGY↗

Zero carbon solid-state rechargeable redox fuel for long duration and seasonal storage

Here, this work presents a unique thermochemical process for charging magnesium-manganese-oxide-based solid-state rechargeable redox fuel. High-temperature heating of the processing furnace can be driven by either renewable electricity or concentrated solar power. The simple recyclable fuel charging concept is based on a tubular falling bed reactor with countercurrent oxygen-depleted gas flow for complete heat recuperation. The main focus of this work is achieving solid flowability at high temperatures (1,450°C) and extracting chemically charged solid at ambient temperature with minimal energy loss. The operation strategies described in this work have enabled consistent magnesium-manganese-oxide particle flow up to 1,450°C. The measured extent of the thermal reduction reaction after cooling the particles is more than 90% of the fully reduced state at equilibrium. The thermal-to-chemical efficiency and overall system efficiency are 96% and 35% respectively, which are the highest reported for thermochemical fuels to date.

25 ENERGY STORAGE↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Motor and drive arrangement for refrigeration system

A heat exchanger system includes a heat exchanger coil circulating a first heat transfer fluid therethrough, and a fan at least partially surrounded by the heat exchanger coil to urge a flow of air through the heat exchanger coil to dissipate thermal energy from the first heat transfer fluid. A brushless direct current fan motor is located the fan to urge rotation of the fan and an ancillary electrical component operably connected to the heat exchanger system and electrically isolated from the first heat transfer fluid.

Feng, Yinshan↗

Analytical solution for partial heating on the exterior of the pipe with application to measuring fluid flow rate

An analytical model using Green’s functions for partial external heating of a pipe is developed, which results in an exact mathematical solution for the radial and axial temperature distribution in the pipe wall. Partial heating consists of a constant heat flux function imposed over a small section of the exterior of a pipe and for a limited time duration. The solution comprises steady-state and transient parts, and an algebraic identity is used to decrease the number of summation terms in the slowly-converging steady- state part. Intrinsic verification principles are used to verify the solution. As an example application, this transient solution is applied toward the development of a simple, noninvasive method for in-field measurement of the flow rate in pipes. Furthermore, to simulate this application, a pulse of energy is imposed to the wall of the pipe, and the developed mathematical solution is used to find the flow rate of the fluid inside the pipe. An optimal experiment is designed to find the best measurement location and time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sparse thermal data for cellular automata modeling of grain structure in additive manufacturing

Grain growth in the wake of the melt pool formed during alloy-based additive manufacturing (AM) is complex and multifaceted, depending on parameters governing heat transport, fluid flow, and solidification itself. Cellular automata (CA) models have proven effective in providing computationally efficient and physically sound predictions of grain structure for several AM problems, but their efficiency is tied to the performance of heat transport models. CA models use only a small portion of the problem's temperature data (near the moving melt pool boundary), and much of the CA calculations do not affect the final result due to re-melting of material. Coupling of and communication between heat transport and solidification models, and eliminating operations irrelevant towards final grain structure prediction, will be necessary for using these methods for efficient simulation of large parts. In this work, we introduce a procedure of decoupling the CA from temperature field simulation, using files of relevant temperature data written by the heat transport model. This approach is validated against the standard coupling approach using data obtained through the computational fluid dynamics software OpenFOAM. Negligible differences are seen in grain size, volume, and texture distributions for multilayer simulation of test problems, while the quantity of temperature data for these test problems was reduced by four orders of magnitude (from 100s of GB to 10s of MB) and the code performance sped up by a factor of around 50. Furthermore, variability in microstructure as a function of cell size, substrate, time step, and nucleation parameters is studied, and it is found that cell sizes less than or equal to 1.67 μm and sufficiently small time steps yield Αstatistically equivalent microstructures. Finally, a potential use case for this CA approach—the layer-wise convergence in grain structure starting from extremes in initial grain size—is examined. This approach's ability to simulate expected trends in nucleation and epitaxial grain growth for large regions of microstructure, simulated independently of heat transport models themselves, should prove useful for investigation of various microstructure uncertainties and prediction of part-scale experimental results.

36 MATERIALS SCIENCE↗

Variations in lithium vapor cave performance predictions due to radial transport and recycling assumptions

The lithium vapor cave is a detached divertor design that uses a single private flux region baffle to contain a dense cloud of lithium vapor to dissipate heat flux. Plasma flows are created via fuel gas puffing in order to minimize lithium contamination of the main plasma. Significant modeling using the 2D edge code SOLPS-ITER has already been performed, predicting that sufficient target heat flux reductions (q$^{max}_{Target}$ MW m −2 ) with ( $n$ Li /$n$ e ) LCFS < 0.05 is possible in a case with 90 MW m −2 unmitigated heat flux in NSTX-U. Low heat flux and low upstream concentration was found with a variety of combinations of divertor geometries, target recycling coefficients, upstream plasma parameters, lithium evaporation locations and deuterium fueling locations, with variations in performance found for each design choice. However, the most universal uncertainty of SOLPS-ITER simulations has until now remained unaddressed systematically, namely the cross-field anomalous particle and heat diffusivities. This article aims to bound the uncertainty in lithium concentration prediction as a result of the assumed deuterium cross-field transport and recycling. For the simulations presented here, a factor of 2.1 increase in the upstream lithium density prediction across a factor of four decrease to the assumed deuterium radial particle diffusivity is found. This result is compared across different assumed deuterium recycling coefficients, known to reduce with lithium injection. Upstream lithium density is found to vary by a factor of 2.4 across a feasible range of recycling coefficients at similar $n$$^{OMP,sep}_{e}$.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100°C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

14 SOLAR ENERGY↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

25 ENERGY STORAGE↗

Physics-Infused AI/ML Based Digital-Twin Framework for Flow-Induced-Vibration Damage Prediction in a Nuclear Reactor Heat Exchanger

This report summarizes some of the ongoing work related to the development of an expert-elicitation-digital-twin framework for real time damage state prediction in heat exchanger components of a nuclear reactor. The framework is targeted towards predicting damage associated with coupled low cycle fatigue (associated with regular heat-up, cool-down and power operation transients) and high cycle fatigue (associated with flow induced vibration transients). The overall framework will be based on a NoSQL based database, physics-infused-geometry-dependent virtual-sensor data, different AI/ML techniques-based data-driven-predictive-model applications (Apps) and real-time plant sensor measurements available through few existing sensors. Towards this overall goal, this report updates some of the ongoing work, such as on implementation of a NoSQL Database (such as MongoDB), FE based heat transfer analysis of a heat exchanger (e.g. of a PWR steam generator) for generating geometry-dependent virtual sensor data and evaluation of various AI/ML models such as based on multivariate linear regression, ensembled decision-tree based Random-Forest and Gradient-Boosting regression and high-dimensional-kernel-function-transformation based Support-Vector-Machine regression models. The AI/ML models were evaluated for predicting multi-time-series thermal states at thousands of 3D point-clouds

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational modeling and neutron imaging to understand interface shape and solute segregation during the vertical gradient freeze growth of BaBrCl:Eu

In this work we apply continuum models to analyze phase change, heat transfer, fluid flow, solute transport, and segregation in order to understand prior neutron imaging observations of the vertical gradient freeze growth of Eu-doped BaBrCl. The models provide a rigorous framework in which to understand the mechanisms that are responsible for the complicated evolution of interface shape and dopant distribution in the growth experiment. We explain how a transition in the solid/liquid interface shape from concave to convex is driven by changes in radial heat transfer caused by furnace design. We also provide a mechanistic explanation of how dynamic growth conditions and changes of the flow structure in the melt result in complicated segregation patterns in this system. A growth pause caused by controller lock-up is shown to result in a band of solute depletion in accordance with classical theory. However, changing flow patterns during growth result in a non-monotonic axial distribution of solute that cannot be explained by simple application of classical segregation models. We assert that the approach presented here, namely the use of rigorous models in conjunction advanced diagnostics, such as neutron imaging, provides an exciting path forward for process optimization and control, accelerating the incremental advances that have, in the past, typically relied on empiricism, experience, and intuition.

36 MATERIALS SCIENCE↗

“Hybridizing heat-integrated 3D printed modules with mass manufacturable, low pressure drop fiber sorbents” (Final Report)

The overall objective of this proposal was to research, develop, and evaluate a modular direct air capture (DAC) system that is simple and scalable. This system was based on the adsorption of CO 2 into commercial polyamines supported by porous fiber sorbents, which can be produced at kilometer per hour scales using our pre-pilot spinning line. We have housed these fiber materials in novel 3D printed modular housing systems that provide easy-to-manufacture and localized heat integration and flow control. This hybridization of fiber sorbent technology with modular housing provided several advantages that led to lower air pressure drops, higher sorbent productivity, as well as ease of manufacturing and assembly unrivaled by existing and emerging heat integrated contactor designs. The modular housing was fabricated with the following features, at a minimum: (i) a tapered air intake to reduce pressure drop related to entrance effects, (ii) a structured network of heat transfer channels to enable localized cooling and heating during adsorption and desorption, respectively, and (iii) low pressure drop supports for the fiber sorbents. This hybrid manufacturing approach provides a facile method for taking fiber sorbents from lab scale to pilot scale as it dramatically simplifies the fabrication of heat integrated contactor structures.

42 ENGINEERING↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Metal foam heat exchangers for air and gas cooling and heating applications

Improved heat exchangers according to several embodiments are provided. The heat exchangers provide improved heat transfer for air flow in wet and dry operating conditions, while minimizing pressure drop across the heat exchanger in some applications. According to one embodiment, an improved heat exchanger includes a plurality of metal foam fins between adjacent heat exchange conduits, the heat exchange conduits being arranged parallel to each other to define parallel flow paths between an inlet header and an outlet header. The metal foam fins occupy a cross-flow region between adjacent conduits, the fins having a fixed angular orientation or being rotatable in unison to vary the thermal capacitance of the heat exchanger.

Nawaz, Kashif↗

Shallow Geothermal Resources for Cooling Applications at the University of Hawai‘i

Scientists at Berkeley Lab have teamed up with The University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s (DOE’s) Energy Transitions Initiative Partnership Project (ETIPP) to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology for building cooling, energy efficiency, and emissions reduction applications in Hawai’i. The team is assessing the data necessary to model the feasibility of deploying this technology, the actual models that will be used, and what hurdles need to be overcome to install a demonstration case. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project, and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, making it crucial to select sites with large enough values of these properties. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Both closed-loop and open-loop systems are being investigated. Another option being considered is using cool seawater as the source of chill. Currently work is progressing on two fronts. A hydrogeologic model for a closed-loop system is being developed for the Stan Sheriff Center at the UH Manoa campus, where a subsurface karst system immediately downgradient of the borefield may provide efficient removal of heated groundwater. The team will also develop a technoeconomic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air conditioning system. At the state scale, geographic information system (GIS) layers of various attributes relevant for GHE are being combined to develop an overall favorability map for employing GHE in Hawai‘i.

Doughty, C↗