A Brief User's Guide for PARTISN. Revision 1

This document is intended as a very basic primer on the use of the PARTISN multigroup discrete-ordinates transport code for neutron criticality and time-independent neutron leakage problems. One-dimensional (r only) spherical and two-dimensional (r-z) cylindrical geometries and only the most basic options are discussed. It is assumed that the Nuclear Data Interface (NDI) is the source of nuclear data, that volume sources are isotropic, and that external boundaries are vacuums. The location and meaning of useful information in the PARTISN output is discussed. A sample input deck for a cylindrical problem that stacks a leakage calculation and a k eff calculation is listed. The method for inputting cross sections by hand (e.g., for analytic benchmark comparisons) is presented.

97 MATHEMATICS AND COMPUTING↗

Monitoring Immune System Function and Reactivation of Latent Viruses in the Artificial Gravity Pilot Study

Numerous studies have indicated that dysregulation of the immune system occurs during or after spaceflight. Using 21 day -6 deg. head-down tilt bed rest as a spaceflight analog, this study describes the effects of artificial gravity as a daily countermeasure on immunity, stress and reactivation of clinically important latent herpes viruses. The specific aims were to evaluate psychological and physiological stress, to determine the status of the immune system and to quantify reactivation of latent herpes viruses. Blood, saliva, and urine samples were collected from each participating subject at different times throughout the study. An immune assessment was performed on all treatment and control subjects that consisted of a comprehensive peripheral immunophenotype analysis, intracellular cytokine profiles and a measurement of T cell function. The treatment group displayed no differences throughout the course of the study with regards to peripheral leukocyte distribution, cytokine production or T cell function. Shedding of EBV and CMV was quantified by real time PCR in saliva and urine samples, respectively. There was no significant difference in CMV DNA in the treatment group as compared to the control group. EBV and VZV on the other hand showed a mild reactivation during the study. There were no significant differences in plasma cortisol between the control and treatment groups. In addition, no significant differences between antiviral antibody titers (EBV-VCA, -EA, -EBNA, CMV) or tetramer-positive (EBV, CMV) were found between the two groups. EBV DNA copies in blood were typically undetectable but never exceeded 1,500 copies per 10(exp 6) PBMCs. These data indicate that the artificial gravity countermeasure and the 21 day head-down tilt bed rest regimen had no observable adverse effect on immune function.

Mehta, Satish↗

Monitoring Immune System Function and Reactivation of Latent Viruses in the Artificial Gravity Pilot Study

Numerous studies have indicated that dysregulation of the immune system occurs during or after spaceflight. Using 21 day -6 degrees head-down tilt bed rest as a spaceflight analog, this study describes the effects of artificial gravity (AG) as a daily countermeasure on immunity, stress and reactivation of clinically important latent herpes viruses. The specific aims were to evaluate psychological and physiological stress, to determine the status of the immune system, and to quantify reactivation of latent herpes viruses. Blood, saliva, and urine samples were collected from each participating subject at different times throughout the study. An immune assessment was performed on all treatment and control subjects that consisted of a comprehensive peripheral immunophenotype analysis, intracellular cytokine profiles and a measurement of T cell function. The treatment group displayed no differences throughout the course of the study with regards to peripheral leukocyte distribution, cytokine production or T cell function. Shedding of Epstein barr virus (EBV), Cytomegalovirus (CMV), and Varicella zoster virus (VZV) was quantified by real time PCR in saliva and urine samples, respectively. There was no significant difference in CMV DNA in the treatment group as compared to the control group. EBV and VZV on the other hand showed a mild reactivation during the study. There were no significant differences in cortisol between the control and treatment groups. In addition, no significant differences between antiviral antibody titers (EBV-VCA, -EA, -EBNA, CMV) or tetramer-positive (EBV, CMV) were found between the two groups. EBV DNA copies in blood were typically undetectable but never exceeded 1,500 copies per 106 PBMCs. Overall, these data indicate that the artificial gravity countermeasure and the 21 day head-down tilt bed rest regimen had no observable adverse effect on immune function.

Mehta, Satish K.↗

Long-term reliability of hand-soldering M55365 Ta capacitors

This is a continuation of the report “Effects of Hand Soldering MIL-PRF-55365 Tantalum Capacitors,” which discusses the parametric effects of convection reflow soldering, JPL standard hand soldering, and optimized hand soldering on solid tantalum capacitors. The current focus is determining the long-term reliability effects of the various soldering techniques. Unfortunately, the 100-piece sample size chosen for the highly accelerated life tests was too small to reliably determine the effects of the different soldering techniques on the lifespan of the parts. In hindsight, this likely could have been predicted based on the large alphas and small betas of the Weibull failure distributions discovered during the scouting trials. Now that the effects of inadequate sample size are better understood, an opportunity exists to not only discover whether there are real differences in the reliability associated with the various soldering techniques, but also the potential to discover the voltage acceleration model and the temperature acceleration effect for these capacitors. It is recommended that the testing be repeated with a more appropriate sample size to capture this useful information.

Spence, Penelope↗

Science and Science-Enabling Activities of the SHERLOC and WATSON Imaging Systems in Jezero Crater, Mars

During its first year of operation, the Perseverance rover explored the cratered and fractured floor of Jezero crater on Mars. Here, we report the use of the Scanning Habitability Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) imaging system that includes two high-resolution cameras, the Autofocus and Contextual Imager (ACI) and Wide Angle Topographic Sensor for Operations and eNgineering (WATSON). ACI is a fixed focus gray scale imager with a resolution of 10.1 μm/pixel whereas WATSON is a variable field of view, variable focus imager capable of resolution down to 14 μm/pixel. WATSON is a reflight of the MArs Hand Lens Imager (MAHLI) imager and has similar capabilities. During first-time activities, WATSON was used to support both science and engineering operations related to sample and abrasion patch assessment and sample collection and caching. WATSON also documented the deployment of the Ingenuity helicopter. The Crater Floor Campaign identified two primary rock units, the Máaz formation and the Séítah formation, which have been interpreted as lava flows and an olivine cumulate, respectively. Interpretation of rock textures with WATSON and ACI images was limited to abraded surfaces because unmodified outcrop surfaces (herein termed “natural surfaces”) show high degrees of dust covering, wind abrasion, and coating by secondary mineral products. WATSON and ACI images support the hypothesis that the material of both the Máaz and Séítah formations consists of largely aqueously altered mafic materials with varying igneous origins.

WATSON↗

Genesis Solar Wind Sample Curation Documentation

Introduction: A scientist with experience as a sample science analyst, provider of flight hardware for multiple missions, and senior engineer in an ISO 2000-rated manufacturing plant has described the timeline of key participants in any PI-led sample return mission, the breadth of the organizations involved [1,2], and, of interest to this meeting, choosing the types of data to preserve and issues of future data accessibility. This work broadens that perspective by giving similar lessons from Genesis sample curation point-of-view. Curation participation regarding data gathering was part of the mission review process from the beginning. Genesis’ story illustrates outcome of several choices about types of data to record and preserve. Precision analysis of solar wind atoms captured in pure, ultraclean substrates is the driving science goal; therefore, detailed documentation was captured from all mission and curation phases and from investigator laboratories because these processes affect the final analytical results [3]. Pre-flight: Design and fabrication of the spacecraft. Like many modern small sample return missions, Genesis was a tightly managed team integrated across science, engineering and curation. Communication across the team was excellent, and, for the most part, the hands-on engineering technicians understood the impacts of “small choices” they routinely make, and the eyes-on oversight of manufacturing processes by scientists was mindful of details. The payload was designed by the Jet Propulsion Laboratory and the spacecraft by Lockheed Martin. Solar wind collectors and instruments were fabricated by multiple vendors and laboratories. The main portion of the payload was assembled at JSC. Fabrication procedures and contamination-control data (with witness coupons) were stored primarily at JSC. The original composition, dimensions and configuration of components, results of thermal testing, etc. are still needed for interpretation of analytical data. At times, these must be estimated from secondary information acquired pre-flight. Moreover, some files (e.g., original 3-D models and early Powerpoint) cannot be opened using software. Archived curation data includes 2-D drawings, material usage lists, QA documentation and analyses of consumables used during fabrication. Important chemical information still resides in archived hardware, paints and lubricants, material coupons, cleaning coupons, environmental witness plates and reference materials from manufacturing facilities. Purity and cleanliness of collector substrates. Semi-conductor vendors provided surface cleanliness data and some purity data. Purity for specific elements of interest was verified by science team members in their laboratories [4]. Curation archived procurement and shipping records, analysis reports, and non-proprietary fabrication data. A physical archive of flight collector reference materials is maintained for future use so additional data can be collected as analytical techniques improve. These are of increased value due to the hard landing upon re-entry. Cleaning and cleanliness assessments of flight hardware. Cleaning of the science canister payload was performed at JSC in a dedicated ISO 4 cleanroom using ultrapure water (UPW). The cleanliness of this UPW was monitored throughout processing. The archive for the clean lab also includes airborne particle counts, airborne molecular and inorganic contamination measurements as well as cleanroom construction material coupons and witness coupons. Hardware cleanliness was assessed by particle counts in rinse water batches. This information is recorded in batch cleaning forms and logbooks, and are, perhaps, of decreased value due to the hard landing. Post-flight: Curation-generated data. The curation handling history of each Genesis sample is documented in a typical astromaterials sample database which captures sample location, physical description and characterization data. Samples have a “shelf life”. Crucial to the preservation of samples is ongoing documentation of the sample environment, initially under curatorial control but is now a separate facility function with requires coordination. PI-generated data. Data on sample characterization and cleaning techniques continues to be generated by sample users [5]. These are often captured in LPSC abstracts, but these “engineering” results often are not publishable as stand-alone papers. We are actively looking for ways to make this information more accessible to users. Ion implants into samples have aided science return and can be shared among investigators. These (and similar) materials should be added to the curatorial collection with appropriate process and characterization data generated externally. Summary: Complete data archives for returned astromaterial samples must be broad in types and formats, and inclusive of environmental monitoring.

Genesis↗

Analytical Needs in a Sample Receiving Facility: Input from the MSR Operation Definition Team

The return of scientifically selected samples from Mars would provide a rare opportunity forinvestigation with the full range of the latest technology available, but to take full advantageof this opportunity, it is important to plan ahead to ensure the pristine nature of the samplesupon arrival within the Earth environment until scientific investigations can begin.The NASA/ESA science community-driven MSR Science Planning Group – Phase 2 (MSPG2)delivered recommendations and guidance regarding curation (1) and science (2, 3) activities tobe performed on the samples under containment. High-level requirements for the infrastruc-ture were also developed by MSPG2 (4). In order to prepare infrastructure-targeted input forthe ESA and NASA facility studies planned in the 2022-2023 timeframe, the agency-led MSROperational Scenarios Definition Team (MOSDT) was assembled to conceptualize the sampleoperations that will inform future architecture teams. Emphasis was placed on the respon-sibility of MOSDT to use community-defined requirements and to represent the view of the international scientific community.All necessary and sufficient instruments and analytical needs described in MSPG2 were inte-grated in MOSDT main deliverable, the operational workflow (see Hays et al, this conference).In MSPG2, notional instruments were split between curation analytical needs, and objective-driven (time-sensitive and sterilization-sensitive) science analytical needs. In MOSDT, whilethe first phases of curation, “pre-Basic Characterization” and “Basic Characterization” wererather streamlined and separate from other analytical needs, “Preliminary Examination” and“Science” instruments were not always physically segregated. In addition to the necessary andsufficient instruments described by MSPG2, the MOSDT recommended additional supportequipment for sterilization, cleanliness and contamination monitoring.It was sometimes necessary for the MOSDT to rely on assumptions to integrate instruments inthe activity workflow. In general, the assumptions were very conservative to limit contaminationand cross-contamination risks. It is expected that future work to refine limits of contaminationwill enable optimization of instrumentation.The community was consulted during the course of the MOSDT work. This abstract’s aimis two-fold: on one hand, inform the scientific community and overall MSR stakeholders, tobring their attention on the analytical needs currently considered as necessary and sufficient;on the other hand, to solicit feedback from a larger community audience to optimize and refineanalytical needs during the next phases of MSR ground-segment preparation.Disclaimer: The decision to implement Mars Sample Return will not be finalized until NASA’scompletion of the program’s National Environmental Policy Act (NEPA) process. This docu-ment is being made available for informational purposes only.[1] Tait et al. (2021) Preliminary planning for Mars Sample Return (MSR) curation activities ina Sample Receiving Facility (SRF). Astrobiology in press, doi:10.1089/ast.2021.0105. [2] Toscaet al. (2021) Time-sensitive aspects of Mars Sample Return (MSR) science. Astrobiologyin press, doi:10.1089/ast.2021.0115. [3] Velbel et al. (2021) Planning implications relatedto sterilization-sensitive science investigations associated with Mars Sample Return (MSR).Astrobiology in press, doi:10.1089/ast.2021.0113. [4] Carrier et al. (2021) Science and curationconsiderations for the design of a Mars Sample Return (MSR) Sample Receiving Facility (SRF).Astrobiology in press, doi:10.1089/ast.2021.0110.

Mars Sample Return↗

MO-FG-204-04: How Iterative Reconstruction Algorithms Affect the NPS of CT Images

Purpose: To evaluate how the third generation model based iterative reconstruction (MBIR) compares with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASiR), and the second generation MBIR based on noise power spectrum (NPS) analysis over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP515 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 19mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 0.984 pitch and reconstructed thickness 2.5mm (VEO3.0: Abd/Pelvis with Texture and NR05). At each CTDIvol level, 10 repeated scans were acquired for achieving sufficient data sampling. The images were reconstructed using Standard kernel with FBP; 20%, 40% and 70% ASiR; and two versions of MBIR (VEO2.0 and 3.0). For evaluating the effect of the ROI spatial location to the Result of NPS, 4 ROI groups were categorized based on their distances from the center of the phantom. Results: VEO3.0 performed inferiorly comparing to VEO2.0 over all dose levels. On the other hand, at low dose levels (less than 3 mGy), it clearly outperformed ASiR and FBP, in NPS values. Therefore, the lower the dose level, the relative performance of MBIR improves. However, the shapes of the NPS show substantial differences in horizontal and vertical sampling dimensions. These differences may determine the characteristics of the noise/texture features in images, and hence, play an important role in image interpretation. Conclusion: The third generation MBIR did not improve over the second generation MBIR in term of NPS analysis. The overall performance of both versions of MBIR improved as compared to other reconstruction algorithms when dose was reduced. The shapes of the NPS curves provided additional value for future characterization of the image noise/texture features.

60 APPLIED LIFE SCIENCES↗

A 3D chiral metal-organic framework based on left-handed helices containing 3-amino-1 H-1,2,4-triazole ligand

A chiral metal-organic framework, [Cu(atr)(OH)]·0.5H{sub 2}O·0.5en (1) (Hatr=3-amino-1 H-1,2,4-triazole, en=ethylenediamine), was constructed via diffusion reaction of the achiral Hatr ligand and CuSO{sub 4} as starting materials. Compound 1 crystallizes in the chiral space group P3{sub 2}21 and features a porous metal-organic framework with 44.1% solvent-accessible volume fabricated by left-handed helices with a pitch height of l{sub p}=10.442 Å. Six helices gather around in a cycle forming a large honeycomb channel with a 6.58 Å inner diameter. Cu(II) center and atr{sup ‒} ligand regarded as 3-connected nodes, compound 1 can be simplified to a 3-c uninodal (4.12{sup 2}) (qtz-h) topological network. A gradual decreasing in the magnetic moment depending on temperature decreasing indicates an antiferromagnetic interaction in 1. The powder XRD confirms the bulk sample is a single crystal pure phase, and the thermogravimetric analysis shows the thermal stability of 1 is up to ca. 240 °C. - Highlights: • The present 3D chiral MOF is built from achiral Hatr ligand. • Six left-handed helices gather into a honeycomb channel in chiral sp P3{sub 2}21. • Compound 1 shows a 3-c uninodal (4.12{sup 2}) or qtz-h topological network. • Compound 1 indicates an antiferromagnetic interaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A High-Performance Embedded Hybrid Methodology for Uncertainty Quantification With Applications

Multiphysics processes modeled by a system of unsteady differential equations are naturally suited for partitioned (modular) solution strategies. We consider such a model where probabilistic uncertainties are present in each module of the system and represented as a set of random input parameters. A straightforward approach in quantifying uncertainties in the predicted solution would be to sample all the input parameters into a single set, and treat the full system as a black-box. Although this method is easily parallelizable and requires minimal modifications to deterministic solver, it is blind to the modular structure of the underlying multiphysical model. On the other hand, using spectral representations polynomial chaos expansions (PCE) can provide richer structural information regarding the dynamics of these uncertainties as they propagate from the inputs to the predicted output, but can be prohibitively expensive to implement in the high-dimensional global space of uncertain parameters. Therefore, we investigated hybrid methodologies wherein each module has the flexibility of using sampling or PCE based methods of capturing local uncertainties while maintaining accuracy in the global uncertainty analysis. For the latter case, we use a conditional PCE model which mitigates the curse of dimension associated with intrusive Galerkin or semi-intrusive Pseudospectral methods. After formalizing the theoretical framework, we demonstrate our proposed method using a numerical viscous flow simulation and benchmark the performance against a solely Monte-Carlo method and solely spectral method.

97 MATHEMATICS AND COMPUTING↗

Development of New Lunar Highland Regolith Simulant, NUW-LHT-5M

Introduction: NASA has a need for large quantities of lunar simulants that closely match future manned lunar missions at landing sites near the Lunar South Pole. The current simulant was designed to approximate NU-LHT-2M, and -4M, except using natural minerals and a fully synthetic, non-basaltic, high calcium glass. Washington Mills in Niagara Falls, NY was contracted to produce this new simulant due to their electric arc furnace (EAF) fusion technology and capabilities for crushing and sizing ceramics. The primary objectives of this work were: (1) to create a commercially produced simulant that contains a high fidelity, high calcium (An90+), low Mg/Fe glass without basaltic constituents; (2) to create a simulant that uses existing, terrestrially mined, and readily available minerals blended with a synthetic glass, and (3) accomplish objectives (1) and (2) using conventional processing methods capable of production levels that can meet substantial current and future demands of NASA projects. Another consideration was that highland simulants closest to meeting these requirements, NU-LHT-2M and -4M types, are out of production and largely out of stock. Design: The design chosen for development and production for this work is NU-LHT-2M, de-signed by Doug Stoeser and Douglas Rickman, which uses Stillwater anorthosite and norite rocks and synthetic glass. The composition targeted the average composition, glass content and particle size distribution of Apollo 16 samples [1]. The design utilizes two Stillwater minerals, anorthosite (37.7 wt.%), norite (17.6 wt.%), a commercially sourced olivine (4.7 wt.%), and a synthetic glass (40 wt.%). Processing: Stillwater rocks were hand collected and initially crushed by the USGS. Further crushing and milling was performed at Washing-ton Mills. For the glass, oxides were blended in the ap-propriate ratios, blended in a v-blender, and placed in a graphite lined, water cooled pot. The mixture was fused in Washington Mills’ pilot scale, 500 kW EAF. The molten glass was then poured into water and quenched to inhibit crystallization. Several pour/quench cycles were required to produce the total quantity of glass needed. Anorthosite, norite and olivine were milled together to the target particle size in a ball mill. The glass was ball milled separately. The complete simulant was produced by blending the milled materials. Particle size distribution, phase and chemical analyses of the materials was were per-formed at Washington Mills. Results: The glass composition was found to match the Apollo 16 oxide content average [1] quite well, with the exception of SiO2 and Fe2O3. The deviation of SiO2 and Fe2O3 from batched content was believed to be due to limitations inherent in the use of the arc furnace technique for these types of materials. A particle size distribution of the full simulant formulation closely matching the average for the Apollo 16 samples was also achieved. Fig. 1 shows the morphology of the final simulant particles. The size distribution is compared to the target in Fig. 2. Conclusions: A new lunar highlands type simulant containing a high-quality synthetic glass, closely matching an average composition of the Apollo 16 regolith was produced. Processing utilized easily scalable mineral and glass making methods.

simulant↗

Characterization of Direct-Push Vadose Zone Sediments from the 241-B and 241-BX Tank Farms

Geochemical tests provide evidence for the transit of a plume of caustic waste solution through the sediment column at the Hanford 241-B and -BX Tank Farms. Direct-push samples recovered from boreholes surrounding Tanks 241-B-110 and 241-BX-102 and related waste transfer lines and diversion boxes included sediments typical of those previously recovered from other localities on the Hanford Site. The Hanford formation sediments are dominantly quartzo-feldspathic sands strewn with lithic fragments, displaying a range of particle size distributions and sorting characteristics. Some moderately well-sorted, fine-grained lithologies are interpreted as lenticular bodies irregularly dispersed in coarser-grained, more poorly sorted sediments. Tier I tests conducted on the vadose zone sediments revealed an inverse correlation between moisture content and sediment size fraction (i.e., there is greater moisture content in finer-grained sediments). The Tier I tests also showed that the pore water solutions were likely sodium-rich, moderately saline, and possessed higher pH values than background (untainted) sediments. These data are characteristic of sediments that have encountered sodium-rich, saline, caustic waste solution, as documented in other reports at other suspect contamination sites around Hanford. Analyses of solutions from 1:1 water extracts reveal relatively balanced cation and anion concentrations, indicating that most of the geochemical species have been accounted for. The water extract data for affected sediments also indicate unusually high concentrations of aluminum, iron, and phosphorus. The relatively high concentrations of aluminum and iron may be the result of dissolution of secondary amorphous phases that precipitated after a reactive plume partially dissolved aluminum- and iron-bearing phases as it migrated through the sediment column. On the other hand, the presence of elevated concentrations of phosphorous may be the tell-tale signature of wastes derived from the bismuth phosphate separation process. Elements typically mobile in the geosphere, such as technetium-99, are present at either low concentrations or are below the analytical detection limit. However, we expect that the mobile elements would be present mainly along a narrow plume front, and if this front had passed deeper into the sediment profile than depths sampled, the retention of these elements would be minor. On the other hand for the direct push sediments from around BX Tank Farm, uranium-238 was detected in nearly all sediment specimens (by acid extract experiments) at concentrations above the natural crustal average (0.763 pCi/g), and we also detected the presence of several anthropogenic radioisotopes, such as cobalt-60, cesium-137, europium-154, and europium-155 (by gamma energy analysis). These data are direct confirmation of contamination of the sediments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy

A new, rapid methodology for trace analysis using solid-phase extraction is described. The two-step methodology is based on the concentration of an analyte onto a membrane disk and on the determination by diffuse reflectance spectroscopy of the amount of analyte extracted on the disk surface. This method, which is adaptable to a wide range of analytes, has been used for monitoring ppm levels of iodine and iodide in spacecraft water. Iodine is used as a biocide in spacecraft water. For these determinations, a water sample is passed through a membrane disk by means of a 10-mL syringe that is attached to a disk holder assembly. The disk, which is a polystyrene-divinylbenzene composite, is impregnated with poly(vinylpyrrolidone) (PVP), which exhaustively concentrates iodine as a yellow iodine-PVP complex. The amount of concentrated iodine is then determined in only 2 s by using a hand-held diffuse reflectance spectrometer by comparing the result with a calibration curve based on the Kubelka-Munk function. The same general procedure can be used to determine iodide levels after its facile and exhaustive oxidation to iodine by peroxymonosulfate (i.e., Oxone reagent). For samples containing both analytes, a two-step procedure can be used in which the iodide concentration is calculated from the difference in iodine levels before and after treatment of the sample with peroxymonosulfate. With this methodology, iodine and iodide levels in the 0.1-5.0 ppm range can be determined with a total workup time of approximately 60 s with a RSD of approximately 6%.

Non-NASA Center↗

The Search for Chiral Asymmetry as a Potential Biosignature in Samples from Mars

The search for evidence of extraterrestrial life in our solar system is currently guided by our understanding of terrestrial biology and its associated biosignatures. The observed homochirality in all life on Earth, that is, the predominance of “left-handed” or L-amino acids and “right-handed” or D-sugars, is a unique property of life that is crucial for molecular recognition, enzymatic function, information storage and structure and is thought to be a prerequisite for the origin or early evolution of life. Therefore, the detection of L- or D-enantiomeric excesses of chiral amino acids and sugars could be a powerful indicator of extant or extinct life on Mars or other habitable environments in our solar system. The exploration of habitable environments on Mars, including an assessment of the preservation potential for complex organics of either abiotic or biological origin, remains a key goal of both current and future Mars missions. Now with the unambiguous detection of indigenous organic matter in sedimentary rocks on Mars [1-3], NASA’s Curiosity rover has significantly advanced our understanding of the preservation of potential chemical biosignatures in the martian near surface. Although amino acids have not yet been identified by in situ measurements on Mars, if they were present, it is expected that amino acid hydrolysis and racemization would be very slow and any chiral or isotopic signatures from an extinct martian biota could be preserved for billions of years, given the extremely cold and dry surface conditions [4]. One of ESA’s Rosalind Franklin rover payload instruments called the Mars Organic Molecule Analyzer (MOMA) includes a wet chemistry package capable of measuring the enantiomeric ratios of any chiral amino acids present at part-per-million concentrations or higher [5]. The complexity and limited duration of spaceflight operations and the known analytical challenges associated with in situ extraction and characterization of trace reduced organic compounds in ancient rocks make it challenging to determine the origins of martian organic matter found to date. Coordinated state-of-the-art laboratory measurements of returned samples from Mars that include spatially resolved chemical, mineralogical, and isotopic studies and molecule-specific isotopic and enantiomeric measurements will be required to firmly establish whether the complex organic matter detected on Mars comes from biotic or abiotic sources. Ultimately, sample return may be our best chance of identifying chemical biosignatures from a past or present martian biota, if one ever existed on Mars. NASA’s Perseverance rover will collect dozens of surface sample cores for possible future return to Earth by NASA and ESA. Here we review our current knowledge of the distributions and enantiomeric and isotopic compositions of non-biological amino acids found in meteorites compared to terrestrial biochemistry and propose a set of measurement criteria that should be used to help establish the origin of any chiral asymmetry detected in samples from Mars [6].

Daniel P Glavin↗

Stable Chlorine Isotope Study: Application to Early Solar System Materials

A significantly large mass fractionation between two stable chlorine isotopes is expected during planetary processes In addition, in view of the isotopic heterogeneity of other light elements, the chlorine isotopes can potentially be used as a tracer for the origins and evolutionary processes of early solar system materials. Due to analytical difficulties, however, current chlorine isotope studies on planetary materials are quite controversial among IRMS (gas source mass spectrometry) and/or TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1-3]. Although a cross-calibration of IRMS and TIMS indicates that both techniques are sufficiently consistent with each other [4], some authors have claimed that the Cl-37/Cl-35 ratio of geological samples obtained by TIMS technique are, in general, misleadingly too high and variable compared to those of IRMS [3]. For example, almost no differences of Cl isotope composition were observed among mantle materials and carbonaceous meteorites by [3]. On the other hand, according to more recent IRMS work [2], significant Cl isotope variations are confirmed for mantle materials. Therefore, additional careful investigation of Cl isotope analyses are now required to confirm real chlorine isotope variations for planetary materials including carbonaceous chondrites [5]. A significantly large mass fractionation between two stable chlorine isotopes is expected during planetary processes In addition, in view of the isotopic heterogeneity of other light elements, the chlorine isotopes can potentially be used as a tracer for the origins and evolutionary processes of early solar system materials. Due to analytical difficulties, however, current chlorine isotope studies on planetary materials are quite controversial among IRMS (gas source mass spectrometry) and/or TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1-3]. Although a cross-calibration of IRMS and TIMS indicates that both techniques are sufficiently consistent with each other [4], some authors have claimed that the 37Cl/35Cl ratio of geological samples obtained by TIMS technique are, in general, misleadingly too high and variable compared to those of IRMS [3]. For eample, almost no differences of Cl isotope composition were observed among mantle materials and carbonaceous meteorites by [3]. On the other hand, according to more recent IRMS work [2], significant Cl isotope variations are confirmed for mantle materials. Therefore, additional careful investigation of Cl isotope analyses are now required to confirm real chlorine isotope variations for planetary materials including carbonaceous chondrites [5]. In order to clarify the stable chlorine isotope features of early solar system materials, we have initiated development of the TIMS technique at NASA JSC applicable to analysis of small amounts of meteoritic and planetary materials. We report here the current status of chlorine isotope analysis at NASA JSC.

Mala,ira. M/↗

Crystal Phases Formed in a CaO-Fe 2 O 3 System Under a High Cooling Rate in Air

A CaO-Fe 2 O 3 system is a fundamental binary system for the iron ore sintering process. Although the basic reactions have been investigated since the 1960s, melting and solidification caused by the combustion of coke results in an unstable state owing to extreme temperature variations. In this study, using a hot thermocouple method, samples of 10 pct CaO-90 pct Fe 2 O 3 and 20 pct CaO-80 pct Fe 2 O 3 were melted on a thermocouple and quenched with several techniques. The obtained samples were precisely examined by XRD. It was found that the sample containing 10 pct CaO-90 pct Fe 2 O 3 changed to 10 pct CaO-13 pct FeO-77 pct Fe 2 O 3 under an oxygen partial pressure (P O 2 ) of 0.21 during melting. For the 10 pct CaO sample, the crystal phases found at a low cooling rate (509 K/s) were WF ss , C 4 WF 8 (C: CaO, W: FeO, F: Fe 2 O 3 ), and C 2 W 4 F 9 . When the sample composition was 20 pct CaO, the precipitated crystal phases were C 4 WF 4 , C 4 F 7 , and C 4 WF 8 . On the other hand, the crystal phases for high cooling rates (1590 and 7900 K/s) with 10 pct CaO were WF ss (solid solution of WF and F), F, and C 2 W 4 F 9 . The formation of the equilibrium phases WF ss , F, C 4 WF 4 , and C 4 WF 8 can be understood by examining the isothermal section of the phase diagrams, while the unstable phases C 2 W 4 F 9 and C 4 F 7 are discussed on the basis of the reactions under an equilibrium state.

36 MATERIALS SCIENCE↗

Miscanthus x giganteus yield in a REpeated PLAnting Year (REPLAY) experiment across three sites in Iowa, USA.

Research objectives were to study nitrogen (N) fertilization and age effect on Miscanthus x giganteus (mxg) yield and their interaction. In addition, we studied how establishment conditions affected mxg yield response to N fertilization. This is the first repeated planting year experiment conducted on perennial bioenergy grasses. Data showed that mxg yield response to N fertilization was highly variable. Establishment effects were an important driver of this variability and caused significant changes on the magnitude and direction of one-year-old stands’ response to N fertilization. With repeated planting we compared yield gain from first to second year of growth of different single starts. Yield gain of each single start was different within and between sites. This site-specific response suggests that important biases could be introduced when comparing results across studies if repeated planting is not utilized. Biomass from mxg plots was sampled annually in winter or early spring after multiple days with freezing temperatures (Table 1). At each harvest, two 1-m2 quadrats per plot were collected by hand at 0.10 m above the soil surface and weighed. In 2016 and 2018, we used a composite subsample to estimate dry matter content. In 2017, the dry weight subsamples were made of 15 randomly collected stems from each plot. Subsamples were weighed in the field and dried to constant mass at 60 °C in a forced air drier. The final mass was recorded and dry matter content was calculated for each plot.

Agricultural Science↗