Geothermal Power Systems Analysis: Outcome of Industry Stakeholders Workshop: Preprint

Geothermal cost and performance evaluation implemented via technoeconomic assessment (TEA) modeling is critical for the Department of Energy (DOE) and other geothermal industry stakeholders in assessing the current state of geothermal technologies and to identify existing hurdles to commercially viable geothermal development. The Geothermal Electricity Technology Evaluation Model (GETEM) is a major TEA tool used in estimating the economic feasibility and levelized cost of energy (LCOE) of conventional hydrothermal systems and enhanced geothermal systems (EGS). Since 2021, GETEM has been transitioning from an intricate spreadsheet model to a user-friendly tool within the System Advisor Model (SAM) developed by the National Renewable Energy Laboratory (NREL). Apart from enabling an expanded visibility of the geothermal model among other renewable resources, having GETEM in SAM has the advantage of simulation automation, better usability, updates tracking, active user inputs/feedback, and extended financial modeling. GETEM is used in developing supply curves for the Annual Technology Baseline (ATB). The ATB data are inputs to the Renewable Energy Potential (reV) and the Regional Energy Deployment System (ReEDS) models. The geothermal module in NREL’s reV model assesses the geothermal energy potential in the conterminous United States by defining the geospatial intersection of geothermal resources with existing grid infrastructure within the constraint of land use characteristics. The ReEDS model is a capacity expansion model used for simulating the long-term build-out and operation of the US generation and transmission system based on current energy costs and policies. To ensure enhanced representation of current industry trends in our model transitions and development, we organized a two-day virtual workshop to elicit geothermal industry stakeholder input and recommendations on our current approaches and assumptions on technoeconomic, resource assessment, and deployment scenarios modeling of geothermal technologies. Participants included developers, operators, investors, regulatory agencies, system modelers, national laboratory researchers, consultants, and other stakeholders. In this workshop, we gained stakeholder insights on current geothermal plant performance (i.e., capacity factors), updated drilling costs and learning curves, and next generation technologies such as closed loop and superhot rock geothermal. Other outcomes from this workshop and its impact on future geothermal development feasibility, resource availability, and capacity expansion studies are compiled and discussed.

Annual Technology Baseline↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydropower Flexibility and Environmental Tradeoffs Analysis

The importance of hydropower increases as the power grid evolves with the higher variable renewable contribution. As conventional thermal power plants are retired, the importance of hydropower contribution increases to balance the variability of solar and wind generation. However, reservoir water resources are constrained by multiple constraints, and variability of water inflow to the reservoirs creates limitations to dam water releases for power grid needs. Coordinating multiple tools, including water resources, ecological, and technical and economic power grid modeling, informs dam water releases. The case study, the Columbia River Basin multipurpose reservoir project, is operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. We integrated a production cost model, a water resource model, and decades of tribal knowledge to analyze the fish-friendly way of operating Columbia hydropower scheduling and grid impacts. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

Columbia River↗

Evaluating the Impact of Tidal Energy in the Cook Inlet on Alaska's Railbelt Electrical Grid

This report presents the findings of a case study that evaluates the impact of integrating significant tidal energy generation in the Cook Inlet in Alaska. The case study is part of a series within the "Quantifying the Grid Value of MRE [Marine Renewable Energy] in Early U.S. Markets" project funded by the U.S. Department of Energy. This study takes a scenario-based approach to evaluate the tidal energy potential in the Cook Inlet, in which 100-500 megawatts (MW) of tidal energy are integrated into the grid under different infrastructure scenarios. These scenarios include increased energy storage and transmission line upgrades, a "Basecase" scenario with no additional upgrades, and a reference case with no tidal energy. We concluded that tidal energy at an installed capacity of 200-300 MW has the potential to reduce fuel costs in Alaska while also reducing carbon emissions and increasing the energy independence of the state. This analysis and the key findings should be viewed as a starting point for additional research and used to inform investment and policy options.

16 TIDAL AND WAVE POWER↗

Leveraging ARM Data to Improve Models for Predictive Understanding of Energy and Security Challenges

Extreme weather and natural hazards can disrupt the energy sector, affecting demand, generation, transmission, distribution, consumption and operational planning at regional and national scales. These disruptions stem from a broad range of atmospheric phenomena, including winter storms, freezing rain, wet snow loading, severe convection, flooding and landslides, wildfires, prolonged heat, and drought. Many of these same phenomena can also affect national security through impacts to transportation and infrastructure. To support the U.S. Department of Energy (DOE) focus on energy resilience and national security, the Atmospheric Radiation Measurement (ARM) User Facility is uniquely positioned to contribute measurement data, analyses, and modeling frameworks that can significantly improve predictive understanding of these hazards to mitigate their effects. To explore this opportunity, ARM convened a two-part virtual workshop in November 2025. The workshop engaged interdisciplinary experts in atmospheric science, energy systems, modeling, and operations. The goal of the meeting was to engage with these interdisciplinary experts to address three questions: • What are examples of atmospheric processes that represent significant risks to energy security or national security and where are those risks greatest? • What measurements or measurement strategies would improve ARM’s capacity to address these issues? • How can ARM and users of the ARM facility better work with the Energy Exascale Earth System Model (E3SM) and multi-sector modeling communities to apply ARM data to improving E3SM simulations of these phenomena? Participants were asked to submit white papers ahead of the meeting to initiate thinking on these themes and to help organize discussions. Workshop sessions were then organized around themes identified in the white papers. First from the white papers and then through subsequent discussions, workshop participants identified many examples that address the three questions listed above. Participants called out energy system vulnerabilities to weather phenomena such as the impact of freezing rain, strong winds, and excessive heat on power grids. They also noted the effects that weather phenomena could have on energy demand or supply (e.g., through effects of extreme temperatures). They called out security vulnerabilities such as impacts to crops from aerosol-borne pathogens and risks to industry due to melting permafrost in the Arctic. In all, over a dozen meteorological phenomena were linked to energy or security vulnerabilities. For many of the identified phenomena, participants pointed out where ARM was well poised to address issues (e.g., through measurements of cloud microphysics to inform studies of freezing rain) but also noted needs for additional measurements or modified measurement strategies. For example, adaptive scanning of severe weather would be valuable for probing winter storms or severe convection. Participants pointed out the value in integrating external observations with ARM measurements and with applying artificial intelligence (AI) to ARM observation analysis and they advocated for using model simulations to help optimize measurement strategies through Observing System Simulation Experiments (OSSEs). It was clear from the workshop that there are many ways that ARM observations can be used to mitigate energy and security concerns, but meeting participants were also asked to identify what they considered to be the greatest opportunities by ranking issues pertaining to the three workshop questions. This was accomplished through a survey administered to participants between the two virtual sessions. The highest-priority phenomena identified were winter storms, severe convection, and arctic processes. Discussion in the second session, therefore, focused primarily on these three areas, which were most fully developed in exploring ARM opportunities. Nevertheless, it was also clear that ARM has opportunities to contribute to all the identified topics. This report describes the workshop, including input from discussion and white papers (Sections 2 and 3) and a list of priority recommendations (section 4). Many other ideas for ARM contributions are discussed in individual white papers (Appendix D).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Geothermal Power Systems Analysis: Outcome of Industry Stakeholders Workshop

Geothermal cost and performance evaluation implemented via techno-economic assessment (TEA) modeling is critical for the U.S. Department of Energy (DOE) and other geothermal industry stakeholders in assessing the current state of geothermal technologies and to identify existing hurdles to commercially viable geothermal development. The Geothermal Electricity Technology Evaluation Model (GETEM) is a major TEA tool used in estimating the economic feasibility and levelized cost of energy (LCOE) of conventional hydrothermal systems and enhanced geothermal systems (EGS). Since 2021, GETEM has been transitioning from an intricate spreadsheet model to a user-friendly tool within the System Advisor Model (SAM) developed by the National Renewable Energy Laboratory (NREL). Apart from enabling an expanded visibility of the geothermal model among other renewable resources, having GETEM in SAM has the advantage of simulation automation, better usability, updates tracking, active user inputs/feedback, and extended financial modeling. GETEM is used in developing supply curves for NREL's Annual Technology Baseline (ATB), which provides inputs to the Renewable Energy Potential (reV) and the Regional Energy Deployment System (ReEDS) models. The geothermal module in NREL's reV model assesses the geothermal energy potential in the conterminous United States by defining the geospatial intersection of geothermal resources with existing grid infrastructure within the constraint of land use characteristics. The ReEDS model is a capacity expansion model used for simulating the long-term build-out and operation of the U.S. generation and transmission system based on current energy costs and policies. To ensure enhanced representation of current industry trends in our model transitions and development, we organized a two-day virtual workshop to elicit geothermal industry stakeholder input and recommendations on our current approaches and assumptions on techno-economic, resource assessment, and deployment scenarios modeling of geothermal technologies. Participants included developers, operators, investors, regulatory agencies, system modelers, national laboratory researchers, consultants, and other stakeholders. In this workshop, we gained stakeholder insights on current geothermal plant performance (i.e., capacity factors), updated drilling costs and learning curves, and next-generation technologies such as closed-loop and superhot rock geothermal. Other outcomes from this workshop and its impact on future geothermal development feasibility, resource availability, and capacity expansion studies are compiled and discussed.

annual technology baseline↗

Small Hydropower Interconnections: State Interconnection Processes

Small hydropower projects with rated power output between 0 to 20 MW have been the predominant source of hydropower growth over the past decade in the United States (DOE 2016; Johnson et al. 2018). However, interconnection to electricity distribution and transmission grids is a persistent barrier. Interconnection of an electricity generating unit is overseen by the distribution or transmission owner, who use interconnection standards and requirements that vary by state. The differences between standards in standards may affect the final cost, timeline, and success of a small hydropower project. Small hydropower project developers across the United States have found interconnection procedures to be fraught with cost surprises and schedule overruns. System operators have struggled to understand impacts to overburdened or rapidly evolving transmission and distribution grids. The results of these shortcomings have been stranded costs and unrealized small hydropower potential. Though regulatory actions and policy recommendations at the state level have increased the situational awareness of interconnection challenges, the remote locations of small hydropower resources and the relatively small revenues associated with energy production through small hydropower facilities continue to make interconnection processes and requirements confusing and costly. Noting these challenges, the U.S. Department of Energy Water Power Technologies Office enlisted Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to investigate the small hydropower interconnection landscape across the United States. The second in a series, this paper investigates the interconnection process in each state in the U.S. to compare their attributes. Subsequent papers in the series will analyze these interconnection processes (“Small Hydropower Interconnections: Analysis of Interconnection Processes”) and present best practices (“Small Hydropower Interconnections: Best Practices”) that will help overcome barriers to future small hydropower development. The first paper in the series examined the state of small hydropower projects in the United States (“Small Hydropower Interconnections: Small Hydropower in the United States”) to understand the industry characteristics.

13 HYDRO ENERGY↗

Incorporation of aerosol into the COSPv2 satellite lidar simulator for climate model evaluation

Abstract. Atmospheric aerosol has substantial impacts on climate, air quality and biogeochemical cycles, and its concentrations are highly variable in space and time. A key variability to evaluate within models that simulate aerosol is the vertical distribution, which influences atmospheric heating profiles and aerosol–cloud interactions, to help constrain aerosol residence time and to better represent the magnitude of simulated impacts. To ensure a consistent comparison between modeled and observed vertical distribution of aerosol, we implemented an aerosol lidar simulator within the Cloud Feedback Model Intercomparison Project (CFMIP) Observation Simulator Package version 2 (COSPv2). We assessed the attenuated total backscattered (ATB) signal and the backscatter ratios (SRs) at 532 nm in the U.S. Department of Energy's Energy Exascale Earth System Model version 1 (E3SMv1). The simulator performs the computations at the same vertical resolution as the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP), making use of aerosol optics from the E3SMv1 model as inputs and assuming that aerosol is uniformly distributed horizontally within each model grid box. The simulator applies a cloud masking and an aerosol detection threshold to obtain the ATB and SR profiles that would be observed above clouds by CALIOP with its aerosol detection capability. Our analysis shows that the aerosol distribution simulated at a seasonal timescale is generally in good agreement with observations. Over the Southern Ocean, however, the model does not produce the SR maximum as observed in the real world. Comparison between clear-sky and all-sky SRs shows little differences, indicating that the cloud screening by potentially incorrect model clouds does not affect the mean aerosol signal averaged over a season. This indicates that the differences between observed and simulated SR values are due not to sampling errors, but to deficiencies in the representation of aerosol in models. Finally, we highlight the need for future applications of lidar observations at multiple wavelengths to provide insights into aerosol properties and distribution and their representation in Earth system models.

54 ENVIRONMENTAL SCIENCES↗

Energy Storage and Decarbonization Analysis for Energy Regulators: Technical Analysis for the Illinois Commerce Commission

Jurisdictions around the world are enacting and enforcing an increasing number of policies to fight climate change, leading to higher penetration of variable renewable energy (VRE) and energy storage systems (ESSs) in the power grid. One of the biggest challenges associated with this process is the evaluation of the appropriate amount of ESS required to mitigate the variability of the VREs and achieve decarbonization goals of a particular jurisdiction. This report presents methodologies developed and results obtained for determining the minimum amount of ESS required to adequately serve load in a system where fossil fueled generators are being replaced by VREs over the next two decades. This technical analysis is performed by Sandia National Laboratories for the DOE Office of Electricity Energy Storage Program in collaboration with the Illinois Commerce Commission (ICC). The Illinois MISO Zone 4 is used as a case study. Several boundary conditions are investigated in this analysis including capacity adequacy and energy adequacy to determine the quantity of ESS required for MISO Zone 4. Multiple scenarios are designed and evaluated to incorporate the impact of varying capacity values of VREs and on the resource adequacy of the system. Several retirement scenarios involving fossil-fueled assets are also considered. Based on the current plans of new additions and retirements of generating assets, the results of the technical analysis indicate that Illinois MISO Zone 4 will require a significant quantity of ESS to satisfy their electricity demand over the next two decades.

25 ENERGY STORAGE↗

Optimal Sizing of an Electric Vehicle Charging Station with Integration of PV and Energy Storage

This paper proposes an optimization model for the optimal configuration of an grid-connected electric vehicle (EV) extreme fast charging station considering integration of photovoltaic (PV) and energy storage. The proposed model minimizes the annualized net cost (i.e., maximizes the annualized net profit) of the extreme fast charging station, including investment and maintenance cost of charging ports, PV and energy storage, net cost of purchasing energy from utility and selling energy to EV customers, degradation cost of energy storage and demand charge. The decision variables are number of charging ports, capacity of invested PV and the power and energy ratings of invested energy storage. The Erlang-loss system is adopted to model the EV mobility. Results of numerical simulations indicate that investment of PV and energy storage could increase the annualized profit of the extreme fast charging station. In addition, the impacts of various parameters on the optimal solution are investigated by sensitivity analysis.

Liu, Guodong↗

Evaluating Emissions Reductions from DERs in REopt Lite

Creating a clear business justification for an energy & water project is essential for developing projects by transforming data and analysis into a compelling story to secure management buy-in. This presentation provides an overview of how distributed energy resources (DERs) can provide cost savings, resilience benefits, and emissions reduction. Many technical and economic factors affect which distributed energy technologies can best meet site goals, and should be considered concurrently. With increasingly integrated and complex systems, back-of-the envelope calculations are no longer sufficient to determine distributed energy project potential. REopt Lite can be used to model emissions and evaluate the impact of DERs on reducing emissions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multi‐variable framework for selecting WRF physics configurations at convection‐permitting scales: An Amazon wet‐season case study

Tropical convection over rainforests modulates atmospheric circulation and the energy and hydrological cycles across multiple scales. However, the scarcity of observations still limits our understanding of these processes. Although numerical models are utilized to investigate atmospheric physical processes, their performance depends on the choice of parameterizations and grid resolution. Here, in this work, we introduce and apply a multi‐variable, multi‐physics framework to evaluate and rank the Advanced Research Weather Research and Forecasting (WRF–ARW) configurations at 1‐km resolution over the central Amazon during the wet season. A 48‐member ensemble combines three land‐surface models (LSMs), four planetary boundary layer (PBL), and four microphysics (MP) schemes. Model performance for seven convection‐related near‐surface and boundary‐layer variables is assessed using Taylor diagrams and the Taylor skill score (TSS), analysis of variance (ANOVA)‐based sensitivity metrics, and non‐parametric rank tests. We then construct a combined, weighted TSS to identify configurations that are comparatively robust across variables. Results showed that most configurations reproduce near‐surface temperature, sensible and latent heat fluxes, and boundary‐layer height reasonably well, whereas humidity and rainfall remain challenging. LSM choice has the strongest impact on the surface fluxes and a secondary influence on near‐surface temperature and humidity, PBL schemes dominate boundary‐layer height, and MP schemes exert the largest control on rainfall. No single configuration is optimal for all variables, but the combination of Noah (LSM), Yonsei University (PBL), and Morrison (MP) emerges as the most robust configuration for this case, with the WRF single‐moment six‐class scheme (WSM6) providing a competitive, computationally cheaper MP alternative. The framework is general and can be applied to other regions, seasons, and convective regimes.

Amazon rainforest↗

Assessing the vulnerability of solar inverters to EMPs: Port testing, PCI modeling, and protection strategies

Renewable energy sources are becoming an ever-larger contributor to the power grid. These renewable energy sources depend upon the power electronic devices, specifically inverters, being essential for connecting Photovoltaic (PV) generation to the grid. However, the Electromagnetic Pulses (EMPs) caused by the high-altitude nuclear explosions can generate fast broad-band pulses with nanosecond rise time, potentially causing damage or destruction to electronic components. To assess the vulnerability of PV inverters to high-altitude EMPs, the port testing and Pulsed Current Injection (PCI) modeling schemes are proposed based on the port impedance analysis. Wide-band frequency measurements are achieved by fusing impedance results from three vector network analyzers. Then, a PCI model is used to simulate the induced response to EMP, with two typical immunity levels of EC5 and EC8 tested. Here, the experiment successfully excites the induced voltage and current under EMP, where the voltage and current can reach 1500V/40A and 8000V/150Aunder EC5 andEC8, respectively. The port vulnerability analysis results demonstrate that only some ports can survive under EC5. To defend against the impact of EMP, three protection strategies are discussed.

42 ENGINEERING↗

Optical galaxy cluster mock catalogs with realistic projection effects: Validations with the SDSS clusters

Galaxy clusters identified in optical imaging surveys suffer from projection effects: Physically unassociated galaxies along a cluster’s line of sight can be counted as its members and boost the observed richness (the number of cluster members). To model the impact of projection on cluster cosmology analyses, we apply a halo occupation distribution model to 𝑁-body simulations to simulate the red galaxies contributing to cluster members, and we use the number of galaxies in a cylinder along the line of sight (counts in cylinders) to model the impact of projection on cluster richness. We compare three projection models: uniform, quadratic, and Gaussian, and we convert between them by matching their effective cylinder volumes. We validate our mock catalogs using SDSS redMaPPer clusters’ data vectors, including counts vs richness, stacked lensing signal, spectroscopic redshift distribution of member galaxies, and richness remeasured on a redshift grid. We find the former two are insensitive to the projection model, while the latter two favor a quadratic projection model with a width of ≈180 ℎ −1 Mpc (equivalent to the volume of a uniform model with a width of 100 ℎ −1 Mpc and a Gaussian model with a width of 110 ℎ −1 Mpc, or a Gaussian redshift error of 0.04). Furthermore, our framework provides an efficient and flexible way to model optical cluster data vectors, paving the way for a simulation-based joint analysis for clusters, galaxies, and shear.

79 ASTRONOMY AND ASTROPHYSICS↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

The impact of development priorities on power system expansion planning in sub-Saharan Africa

Sub-Saharan Africa faces unique barriers to electricity development due to the large proportion of the population that is un-electrified and the prevalence of rural populations. Typically, power system expansion planning models assume all potential consumers can be immediately electrified. This assumption is unrealistic in sub-Saharan Africa, where electrification will likely be a gradual process over a number of years. Furthermore, since a large proportion of the population in sub-Saharan Africa is located in rural regions, the prioritization of these regions may impact how the grid develops. In this research, we develop a multi-period optimization model for power generation and transmission system expansion planning in sub-Saharan Africa. In contrast to existing models, which assume full electrification, we consider a variety of electrification policies and analyze the impact of varying the electrification rate and policy on the cost and resources selected for power system expansion. We test our model on a case study of Rwanda. We find that varying the year in which full electrification is reached has a larger impact on cost and generation capacity than varying the electrification policy does, although, when urban and rural regions are considered equitably, more rooftop solar is built. Varying the electrification policies has a larger impact on transmission expansion than on generation expansion and this impact is amplified when starting from zero initial system capacity rather than the original Rwanda system. Additionally, a sensitivity analysis shows that tightening the bounds on CO 2eq emissions has a large impact on the generation portfolio and cost.

97 MATHEMATICS AND COMPUTING↗